Science and Technology for the Built Environment最新文献

筛选
英文 中文
The Clinical and Environmental Effects of an Advanced Air Purification Technology in Multiple Healthcare Settings 先进空气净化技术在多个医疗机构的临床和环境影响
4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-10-18 DOI: 10.1080/23744731.2023.2266349
Alicia R. Urrutia, Stanislaw P. Stawicki, Charles N. Kimble, Kathryn C. Worrilow
{"title":"The Clinical and Environmental Effects of an Advanced Air Purification Technology in Multiple Healthcare Settings","authors":"Alicia R. Urrutia, Stanislaw P. Stawicki, Charles N. Kimble, Kathryn C. Worrilow","doi":"10.1080/23744731.2023.2266349","DOIUrl":"https://doi.org/10.1080/23744731.2023.2266349","url":null,"abstract":"Many facility acquired infection (FAI) causing pathogens are airborne and controlling them is critical to preventing illness. An advanced air purification technology (AAPT) was designed to inactivate the genetic material of pathogens and remediate volatile organic compounds (VOCs). This study explores the effect of the AAPT on critical metrics in multiple healthcare settings. The AAPT was installed in the heating, ventilation, and air conditioning (HVAC) ductwork of a hospital’s medical surgical floor (ACH-MSF), a second hospital’s post-anesthesia care unit (PACU), intensive care unit (ICU) and medical surgical (MS) unit, and in a senior living facility’s (SLF) memory support unit. In all installations, the control area(s) were protected only by high efficiency particulate air (HEPA) filtration. The measured airborne fungal levels, airborne and surface bacterial levels, and VOC levels decreased with installation of AAPT. The AAPT removed infectious airborne pathogens and reduced surface pathogens and VOCs. The ACH-MSF and SLF protected by the AAPT documented improved clinical and economic metrics including a 39.5% decrease in patient length of stay, 23% in cost savings improvement, and a 39.6% decrease in FAIs. The current findings support the hypothesis that indoor environmental quality impacts wellness and has potential applications to diverse indoor environments.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135823705","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Detailed evaluation of electric demand load shifting potential of heat pump water heaters in a hot humid climate 湿热气候条件下热泵热水器电力需求负荷转移潜力的详细评价
4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-10-18 DOI: 10.1080/23744731.2023.2261808
Karen Fenaughty, Danny S. Parker, Joshua Butzbaugh, Carlos Colon
{"title":"Detailed evaluation of electric demand load shifting potential of heat pump water heaters in a hot humid climate","authors":"Karen Fenaughty, Danny S. Parker, Joshua Butzbaugh, Carlos Colon","doi":"10.1080/23744731.2023.2261808","DOIUrl":"https://doi.org/10.1080/23744731.2023.2261808","url":null,"abstract":"AbstractHeat pump water heaters (HPWH) are a proven method of reducing water heating energy use over prevailing electric resistance systems (ERWH). Both technologies lend themselves to enhanced control for peak load reduction. Laboratory tests were conducted in Central Florida using the CTA-2045 standard to evaluate load shifting strategies with connected water heaters. Four HPWHs from three manufacturers, including two different tank volumes were tested alongside an ERWH in a garage-like environment. Tests aimed to shift energy use away from utility peak load periods to off-peak times when excess renewable energy resources are available. Two load-shifting strategies were shown effective, Shed and Critical Peak, with variation by manufacturer. Beyond draw volume, other factors influenced HPWH load shifting:Florida winter conditions, which increase the energy used per draw, provided the greatest challenges to complete load shift. Inlet water temperature had a large impact on the success of load reduction. Ground temperatures in which water pipes were buried largely determined inlet water temperatures.HPWH efficiency setting: Heat pump water heaters often default to a “hybrid” mode that may use some electric resistance heat to minimize risk of running out of hot water. Operational mode can impact load shifting potential. BackgroundHeat pump water heaters (HPWH) are a well demonstrated technology to significantly reduce electricity consumption for meeting household hot water needs. A variety of monitored projects around the U.S. have shown savings of 50-70%, reflected by operational coefficient of performance (COP), relative to conventional electric resistance storage water heaters (Colon et al. 2016; Shapiro and Puttagunta 2016; Willem, Lin, and Lekov 2017). Within the last decade, systems have shown even higher operational COPs from improved compressors and other design enhancements. (Willem, Lin, and Lekov 2017).Beyond the ability to save water heating electricity, HPWHs can also cut peak demand. Many large utility providers in the southeast already have demand response and load management programs (Butzbaugh and Winiarski 2020) and may find value in promoting grid-connected HPWHs capable of load shifting if demonstrated to provide superior load control. This can be thought of as the ability to not only control utility-coincident peak loads, but also to alter the water heating electrical demand profile in a significant manner (e.g., alter electric load profile shape to consume a greater amount of daytime utility scale renewable energy). Current HPWHs and some ERWHs available for purchase are compatible with CTA-2045-A protocol (ANSI/CTA 2018). This protocol has demonstrated electric demand flexibility in the Northwest to provide a utility the ability to control when an appliance draws power from the grid (Metzger et al. 2018). And Carew et al (2018) have detailed simulation studies of load shifting with HPWHs. Other related work evaluating HPWHs ","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135824018","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance Assessment of a Real Water Source Heat Pump within a Hardware-in-the-Loop (HIL) Testing Environment 真实水源热泵在半实物(HIL)测试环境下的性能评估
4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-10-02 DOI: 10.1080/23744731.2023.2261810
Caleb Calfa, Zhiyao Yang, Yicheng Li, Zhelun Chen, Zheng O’Neill, Jin Wen
{"title":"Performance Assessment of a Real Water Source Heat Pump within a Hardware-in-the-Loop (HIL) Testing Environment","authors":"Caleb Calfa, Zhiyao Yang, Yicheng Li, Zhelun Chen, Zheng O’Neill, Jin Wen","doi":"10.1080/23744731.2023.2261810","DOIUrl":"https://doi.org/10.1080/23744731.2023.2261810","url":null,"abstract":"Abstract:Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environement, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4 % and ± 3.6 % in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4 % in cooling mode, and ± 3.7% in heating mode. A preliminary 24-hour experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. . The results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.Keywords: Water-Source Heat PumpHardware-in-the-LoopExperimentalDisclaimerAs a service to authors and researchers we are providing this version of an accepted manuscript (AM). Copye","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135896000","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Empirical Analysis of the Prevalence of HVAC Faults in Commercial Buildings 商业建筑暖通空调故障发生率的实证分析
4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-09-29 DOI: 10.1080/23744731.2023.2263324
Eliot Crowe, Yimin Chen, Hayden Reeve, David Yuill, Amir Ebrahimifakhar, Yuxuan Chen, Lucas Troup, Amanda Smith, Jessica Granderson
{"title":"Empirical Analysis of the Prevalence of HVAC Faults in Commercial Buildings","authors":"Eliot Crowe, Yimin Chen, Hayden Reeve, David Yuill, Amir Ebrahimifakhar, Yuxuan Chen, Lucas Troup, Amanda Smith, Jessica Granderson","doi":"10.1080/23744731.2023.2263324","DOIUrl":"https://doi.org/10.1080/23744731.2023.2263324","url":null,"abstract":"Commercial building HVAC systems experience many sensing, mechanical, and control-related faults that increase energy consumption and impact occupant comfort. Fault detection & diagnostics (FDD) software has been demonstrated to identify and help diagnose these types of faults. Several studies have demonstrated FDD energy savings potential, but there is limited empirical data characterizing the quantity and type of faults reported by FDD tools. This paper presents results of an FDD fault reporting study, employing multi-year monitoring data for over 60,000 pieces of HVAC equipment, covering over 90 fault types, and using new metrics that we developed to characterize fault prevalence. Study results offer an unprecedented accounting of the quantity of faults reported, the most commonly occurring faults, and fault persistence. We find that 21 air handling unit (AHU) faults were reported on 20% or more AHUs in our dataset, and 18 AHU faults persisted for more than 20% of the time period covered by the data. On any given day, 40% of AHUs and 30% of air terminal units saw a reported fault of some kind. Based on in-depth analysis of these results we provide recommendations for building operators, FDD software developers, and researchers to enable more efficient commercial building operation.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135246733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
On the Use of Vision-based Drone Application to Building Digitalization, Diagnostics and Energy Efficiency Assessment * 基于视觉的无人机在建筑数字化、诊断和能效评估中的应用研究*
4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-09-27 DOI: 10.1080/23744731.2023.2261807
Kevin Autelitano, Michele Bolognini, Enrico de Angelis, Lorenzo Fagiano, Marco Scaioni
{"title":"On the Use of Vision-based Drone Application to Building Digitalization, Diagnostics and Energy Efficiency Assessment <sup>*</sup>","authors":"Kevin Autelitano, Michele Bolognini, Enrico de Angelis, Lorenzo Fagiano, Marco Scaioni","doi":"10.1080/23744731.2023.2261807","DOIUrl":"https://doi.org/10.1080/23744731.2023.2261807","url":null,"abstract":"AbstractThe adoption of Unmanned Aerial Vehicles for energy efficiency assessment is a promising technique. Although there are some interesting ideas to automate the process, most of the operations are still done manually. An integrated methodology is presented to identify maintenance needs from both RGB and IR images collected with a commercial drone. The real building selected as case study is reconstructed in a 3D environment through Structure from Motion, while the infrared information is integrated and properly scaled on it to obtain a 3D point cloud model that provides, for each point: (i) information about its position in the space (ii) external surface temperature measured during data gathering phase. The point cloud is then segmented into the different sides of the envelope to identify each part of the façade and compared with a model that reconstructs the expected conditions of the building. This procedure enables the development of an automated pipeline to identify defects and failures in a building envelope and to suggest corrective actionsDisclaimerAs a service to authors and researchers we are providing this version of an accepted manuscript (AM). Copyediting, typesetting, and review of the resulting proofs will be undertaken on this manuscript before final publication of the Version of Record (VoR). During production and pre-press, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal relate to these versions also.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"135535478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical Simulation on Flow Boiling Heat Transfer of R1234ze(E)/R152a in a Horizontal Smooth Tube R1234ze(E)/R152a在水平光滑管内流动沸腾传热的数值模拟
IF 1.9 4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-09-01 DOI: 10.1080/23744731.2023.2253084
Yuande Dai, Ziyu Wang, Jiahuan Wu, Chao Xu
{"title":"Numerical Simulation on Flow Boiling Heat Transfer of R1234ze(E)/R152a in a Horizontal Smooth Tube","authors":"Yuande Dai, Ziyu Wang, Jiahuan Wu, Chao Xu","doi":"10.1080/23744731.2023.2253084","DOIUrl":"https://doi.org/10.1080/23744731.2023.2253084","url":null,"abstract":"The understanding of two-phase flow and heat transfer characteristics of refrigerants in tubes is important for guiding the design and optimization of heat exchangers. Based on the volume of fluid (VOF) multiphase model, this paper established a numerical model of R1234ze(E)/R152a (mass ratio of 0.4/0.6) flow boiling heat transfer in a horizontal smooth copper tube with an inner diameter of 6 mm and a length of 900 mm. The distribution of vapor volume fraction is obtained, and the influence of mass flux, heat flux, saturation temperature, and vapor quality on heat transfer coefficient (HTC) are studied. Bubble flow, plug flow, stratified flow, and wavy flow can be observed during the whole process and the fluid temperature increases along the tube. Local and time-averaged heat transfer coefficients and temperature distribution along the axial direction were studied. And the results indicate that the HTC decreases first and then increases with the augmentation of mass flux while increasing with the rise of heat flux. In addition, the HTC rises along with saturation temperature and decreases along with vapor quality. The largest related standard deviation between the simulation value and the testing data is 6.31%. Thus, the numerical simulation has a high level of accuracy.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":" ","pages":""},"PeriodicalIF":1.9,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49315173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reducing Microgrid Availability to Reduce Costs for Coastal Puerto Rican Communities 减少微电网可用性以降低波多黎各沿海社区的成本
IF 1.9 4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-08-31 DOI: 10.1080/23744731.2023.2253087
D. Villa, J. Quiroz
{"title":"Reducing Microgrid Availability to Reduce Costs for Coastal Puerto Rican Communities","authors":"D. Villa, J. Quiroz","doi":"10.1080/23744731.2023.2253087","DOIUrl":"https://doi.org/10.1080/23744731.2023.2253087","url":null,"abstract":"Renewable microgrids are sustainable, resilient solutions to mitigate and adapt to climate change. Making electric loads nearly 100% available (i.e., power remains on) during outages increases cost. Near 100% availability is required when human life or high-cost assets are involved, but availability can be reduced for less consequential loads leading to lower costs. This study analyses costs for photo-voltaic and lithium-ion battery microgrids with availability ranging from 0–99%. We develop a methodology to analyse three Puerto Rican coastal communities. We consider power outage effects for hurricanes, earthquakes, and everyday outages. The results show cost versus availability from 0–99%. There is 27–31% cost reduction at 80% availability in comparison to 99% availability. A regression model of microgrid availability versus three ratios: 1) the annual generation to demand ratio, 2) storage to interruption energy ratio, and 3) peak storage to load ratio produced a coefficient of determination of 0.99949 with 70% of the data used for training and 30% for testing. The results can therefore be extended to other coastal Puerto Rican communities of varying sizes that have ratios within the ranges analysed in this study. This can empower decision makers to rapidly analyse designs that have availabilities well below 100%.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":" ","pages":""},"PeriodicalIF":1.9,"publicationDate":"2023-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43926115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Model-Free MIMO Control Tuning of a Chiller Process Using Reinforcement Learning 基于强化学习的无模型多输入多输出控制
IF 1.9 4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-08-30 DOI: 10.1080/23744731.2023.2247938
Christian Rosdahl, B. Bernhardsson, Bryan A. Eisenhower
{"title":"Model-Free MIMO Control Tuning of a Chiller Process Using Reinforcement Learning","authors":"Christian Rosdahl, B. Bernhardsson, Bryan A. Eisenhower","doi":"10.1080/23744731.2023.2247938","DOIUrl":"https://doi.org/10.1080/23744731.2023.2247938","url":null,"abstract":"The performance of HVAC equipment, including chillers, is continuing to be pushed to theoretical limits, which impacts the necessity for advanced control logic to operate them efficiently and robustly. At the same time, their architectures are becoming more complex; many systems have multiple compressors, expansion devices, evaporators, circuits, or other elements that challenge control design and resulting performance. In order to maintain respectful controlled speed of response, stability, and robustness, controllers are becoming more complex, including the move from thermostatic control, to proportional integrator (PI), and to multiple-input multiple-output (MIMO) controllers. Model-based control design works well for their synthesis, while having accurate models for numerous product variants is unrealistic, often leading to very conservative designs. To address this, we propose and demonstrate a learning-based control tuner that supports the design of MIMO decoupling PI controllers using online information to adapt controller coefficients from an initial guess during commissioning or operation. The approach is tested on a physics-based model of a water-cooled screw chiller. The method is able to find a controller that performs better than a nominal controller (two single PI controllers) in terms of decreasing deviations from the operating point during disturbances while still following reference changes.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":" ","pages":""},"PeriodicalIF":1.9,"publicationDate":"2023-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45019010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Chemical Stability Investigation of Haloolefin Refrigerants and Their Blends with Lubricants 卤代烃制冷剂及其与润滑油共混物的化学稳定性研究
IF 1.9 4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-08-29 DOI: 10.1080/23744731.2023.2253085
S. Kujak, Morgan Leehey
{"title":"Chemical Stability Investigation of Haloolefin Refrigerants and Their Blends with Lubricants","authors":"S. Kujak, Morgan Leehey","doi":"10.1080/23744731.2023.2253085","DOIUrl":"https://doi.org/10.1080/23744731.2023.2253085","url":null,"abstract":"This paper examines the findings of highly accelerated life tests (HALT), conducted according to ASHRAE Standard 97 sealed glass tube methodology for R-123 like, R-134a like and R-410A/R-404A like lower global warming potential (GWP) alternatives. Additionally, possible chemical breakdown pathways are reviewed for the new haloolefin refrigerants. Note, compositions for the following blends are shown as percent by weight. For R-123 like refrigerants, R-1336mzz(Z), R-1336mzz(E), R-514A (74.7% R-1336mzz(Z)/25.3% R-1130(E)), R-1233zd(E), and R-1224yd(Z) were examined with and without lubricants. R-1233zd(E) and R-1224yd(Z) were evaluated with mineral oil and the rest were evaluated with polyalkylene glycol (PAG), polyolester (POE) and polyvinyl ether (PVE) lubricants. For R-134a like refrigerants, R-1234ze(E), R-450A (42% R-134a/58% R-1234ze(E)), R-515B (91.1% R-1234ze(E)/8.9% R-227ea), R-1234yf, R-513A (56% R-1234yf/44% R-134a), and R-516A (77.5% R-1234yf/8.5% R-134a/14.0% R-152a) were examined with and without PAG, POE, and PVE lubricants. For R-410A/R-404A like, R-454B (68.9% R-32/31.1% R-1234yf), R-454C (21.5% R-32/78.5% R-1234yf), R-455A (3.0% R-744/21.5% R-32/75.5% R-1234yf), and R-468A (3.5% R-1132a/21.5% R-32/75.0% R-1234yf) were also examined with PAG, POE and PVE lubricants. R-466A (49% R-32/11.5% R-125/39.5% CF3I) was part of this study but will not be covered since it does not contain a haloolefin component.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":" ","pages":""},"PeriodicalIF":1.9,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43631629","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Phase change materials embedded in expanded clay aggregates to develop energy storage concrete: a review 相变材料嵌入膨胀粘土骨料中开发储能混凝土:综述
IF 1.9 4区 工程技术
Science and Technology for the Built Environment Pub Date : 2023-08-29 DOI: 10.1080/23744731.2023.2253089
Mahsa Salimi, L. De Nardo, V. Carvelli
{"title":"Phase change materials embedded in expanded clay aggregates to develop energy storage concrete: a review","authors":"Mahsa Salimi, L. De Nardo, V. Carvelli","doi":"10.1080/23744731.2023.2253089","DOIUrl":"https://doi.org/10.1080/23744731.2023.2253089","url":null,"abstract":"Thermal energy storage (TES) based on phase change materials (PCM) is an effective strategy to reduce energy consumption in buildings. The efficient implementation of TES in building through PCMs, requires modification of their thermal performance, appropriate design and evaluation of their thermal and economic efficiency. One major challenge in the application of PCMs is the selection of high-performance and environmental-friendly supporting materials to overcome the most critical drawback of PCMs (solid-to-liquid transition and resulting leakage). This review focuses on expanded clay (EC) lightweight aggregate (LWA), as one of the promising supporting materials for development of form-stabilized PCM (FSPCM) in the lightweight concrete (LWC) industry. The large specific surface area and porous structure of expanded clay can maintain considerable amount of PCM. In addition, mechanical properties and compatibility with various PCMs make EC a suitable carrier. A detailed review of available researches is presented to elucidate the properties of PCMs embedded in EC for thermally efficient cement-based concrete. Various combinations of EC with the most used PCMs, thermal and mechanical properties of matrices containing PCM-EC, strategies to improve the efficiency of PCM performance, and finally the impact of PCM-EC based concretes on the thermal comfort of buildings are critically summarized.","PeriodicalId":21556,"journal":{"name":"Science and Technology for the Built Environment","volume":" ","pages":""},"PeriodicalIF":1.9,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46133587","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信