2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems最新文献

筛选
英文 中文
Micro Chemical Vapor Deposition System: Design and Verification 微化学气相沉积系统:设计与验证
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805322
Q. Zhou, L. Lin
{"title":"Micro Chemical Vapor Deposition System: Design and Verification","authors":"Q. Zhou, L. Lin","doi":"10.1109/MEMSYS.2009.4805322","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805322","url":null,"abstract":"The conventional chemical vapor deposition system has been miniaturized to the micro scale, leading to several potential advantages for the synthesis of nanostructures. First, minute heat capacity leads to fast temperature stabilization. Second, tiny chamber volume helps for rapid gas species exchanges. Third, small Reynolds number ensures laminar flow for better control of deposition sources. Forth, small diffusion length near the chemical reaction surface enhances efficient gas mass transfer. As a demonstration of principle, high-quality single-walled carbon nanotubes (SWNTs) are synthesized while similar experimental parameters in a large scale system fail to construct good quality SWNTs.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116200057","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Optical Micromirror Actuation using Thermocapillary Effect in Microdroplets 利用微滴热毛细效应驱动光学微镜
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805553
R. K. Dhull, I. Puchades, L. Fuller, Y. W. Lu
{"title":"Optical Micromirror Actuation using Thermocapillary Effect in Microdroplets","authors":"R. K. Dhull, I. Puchades, L. Fuller, Y. W. Lu","doi":"10.1109/MEMSYS.2009.4805553","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805553","url":null,"abstract":"This paper presents a simple means that utilizes surface tension gradient to cause droplet deformation, and to tilt micro-objects. Thermocapillary or Marangoni effect, and contact angle hysteresis are employed to control the droplet shape and position. The device consists of a microplate placed onto a microdroplet, and can produce a 6.5° tilting angle when actuated at 30 V. It shows the potential applications in scanning micromirror and display technology.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"159 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114423895","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Powerful Actuation of Magnetized Microtool by Focused Magnetic Field on a Disposable Microfluidic Chip 一次性微流控芯片聚焦磁场对磁化微工具的强力驱动
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805316
F. Arai, S. Sakuma, Yoko Yamanishi, K. Onda
{"title":"Powerful Actuation of Magnetized Microtool by Focused Magnetic Field on a Disposable Microfluidic Chip","authors":"F. Arai, S. Sakuma, Yoko Yamanishi, K. Onda","doi":"10.1109/MEMSYS.2009.4805316","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805316","url":null,"abstract":"We succeeded in powerful noncontact actuation of magnetically driven microtool (MMT) by magnetizing it and focusing magnetic field in a microfluidic chip. Novelty of this paper is summarized as follows. (1) We employed neodium powder as the main component of MMT. The density of magnetic flux was improved about 100 times larger after magnetization. (2) We fabricated a pair of magnetic sharp needles in the chip by electroplating. MMT was placed between the needles and the density of magnetic flux was improved about 3 times larger. As a result, we succeeded in powerful actuation of MMT in the chip. Drive frequency was improved about 10 times faster (up to 180Hz).","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127288678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Low-Resonant-Frequency Micro Electret Generator for Energy Harvesting Application 用于能量收集的低谐振频率微型驻极体发生器
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805569
M. Edamoto, Y. Suzuki, N. Kasagi, K. Kashiwagi, Y. Morizawa, T. Yokoyama, T. Seki, M. Oba
{"title":"Low-Resonant-Frequency Micro Electret Generator for Energy Harvesting Application","authors":"M. Edamoto, Y. Suzuki, N. Kasagi, K. Kashiwagi, Y. Morizawa, T. Yokoyama, T. Seki, M. Oba","doi":"10.1109/MEMSYS.2009.4805569","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805569","url":null,"abstract":"A vibration-driven electret generator has been developed for energy harvesting applications. By using parylene as the spring material, a low-resonant-frequency MEMS generator is realized. Electrostatic levitation is adopted for the gap control. Large in-plane amplitude of 0.5 mm at the resonant frequency as low as 21 Hz has been achieved. We also demonstrate electret-powered operation of LED using a low-power-consumption impedance conversion circuit.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"72 5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123526361","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 61
Mass-Analysis Scanning Force Microscopy with Electrostatic Switching Mechanism 带静电开关机构的质量分析扫描力显微镜
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805562
C. Shao, Y. Kawai, T. Ono, M. Esashi
{"title":"Mass-Analysis Scanning Force Microscopy with Electrostatic Switching Mechanism","authors":"C. Shao, Y. Kawai, T. Ono, M. Esashi","doi":"10.1109/MEMSYS.2009.4805562","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805562","url":null,"abstract":"A time-of-flight scanning force microscope (SFM) probe with an ability to switch the measurement mode using the electrostatically switching mechanism is designed, fabricated and demonstrated the performance of it. In order to achieve surface observation and chemical analysis simultaneously for imaging the chemical property of a material surface, this probe can switch the positions of the cantilever between SFM mode and time-of-flight mass analysis (TOF-MA) mode by integrating a couple of electrostatic actuator with curved electrode. This mechanism will be applied to pick up an atom or molecule under SFM mode, then emits them to TOF mass analyzer using field evaporation for analyzing its mass in TOF-MA mode. To switch the cantilever position at TOF-MA mode, the fabricated probe generated the 255¿m of maximum displacement at the end of cantilever at an actuation voltage of 180V. The cantilever is attracted with the electrode according to the curved shape using electrostatically pull-in effect. The front edge of the cantilever was aligned in front of integrated extraction electrode for emitting chemical species. In SFM mode, the cantilever was also attracted to another electrode. The fundamental resonant frequency of the cantilever is increased from 1.8kHz to 6.8kHz before and after actuation. A calculated spring constant is changed from 0.05N/m to 0.34N/m.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123539301","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrostatic Rotary Stepper Micromotor for Skew Angle Compensation in Hard Disk Drive 用于硬盘倾斜角补偿的静电旋转步进微电机
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805574
E. Sarajlic, C. Yamahata, M. Cordero, H. Fujita
{"title":"Electrostatic Rotary Stepper Micromotor for Skew Angle Compensation in Hard Disk Drive","authors":"E. Sarajlic, C. Yamahata, M. Cordero, H. Fujita","doi":"10.1109/MEMSYS.2009.4805574","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805574","url":null,"abstract":"Circular data tracks in present-day hard disk drives (HDD) are accessed by a read/write head mounted on a support arm, which is swung by a voice coil drive. The orientation of the head relative to a data track varies with the radial position of the track, causing an increase in data track misregistration and limiting the performance of HDD. We present a rotary micromotor which can be used as a secondary stage actuator to maintain a constant orientation between the head and the tracks during disk operation. This electrostatic stepper micromotor, bulk micromachined in a standard monocrystalline silicon wafer, uses flexure pivots to avoid any frictional contact of the rotor, providing precise, repeatable and reliable bidirectional stepping motion without feedback control. The experimental characterization of a prototype having a diameter of 1.4 mm has demonstrated a rotational range of 26° (+/- 13°) at 75 V, a resolution of 1/6° in a coarse stepping mode and a maximum speed of 1.67°/ms.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121618524","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
CMOS-Compatible Surface-Micromachined Test Structure for Determination of Thermal Conductivity of Thin Film Materials based on Seebeck Effect 基于塞贝克效应的薄膜材料热导率测定的cmos兼容表面微加工测试结构
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805459
Z. Wang, P. Fiorini, C. van Hoof
{"title":"CMOS-Compatible Surface-Micromachined Test Structure for Determination of Thermal Conductivity of Thin Film Materials based on Seebeck Effect","authors":"Z. Wang, P. Fiorini, C. van Hoof","doi":"10.1109/MEMSYS.2009.4805459","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805459","url":null,"abstract":"This paper reports the design, modeling, fabrication and measurement of a CMOS-compatible surface-micromachined test structure for the determination of the thermal conductivity of thin films based on the Seebeck effect. The Seebeck effect-based temperature sensing is more advantageous for thin film materials with a relatively large Seebeck coefficient, such as lightly doped poly-Si and poly-SiGe. In this paper, the conceptual design is first analyzed and then verified with finite element modeling. The test structure is fabricated with poly-Si70% Ge30%. Its functionality is demonstrated from experimental results. The sources of the measurement error are discussed and the solutions to minimize the measurement error are proposed.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121923929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Bead-Based Microfluidic Platform Integrated with Optical Detection Devices for Rapid Detection of Genetic Deletion from Saliva 基于微流控平台集成光学检测装置的唾液基因缺失快速检测
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805388
K. Lien, Chien-Ju Liu, P. Kuo, Gwo-Bin Lee
{"title":"Bead-Based Microfluidic Platform Integrated with Optical Detection Devices for Rapid Detection of Genetic Deletion from Saliva","authors":"K. Lien, Chien-Ju Liu, P. Kuo, Gwo-Bin Lee","doi":"10.1109/MEMSYS.2009.4805388","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805388","url":null,"abstract":"This study presents a new magnetic bead-based microfluidic platform for genomic DNA (gDNA) extraction and rapid detection of genetic deletion from saliva samples by using micro-electro-mechanical-systems (MEMS)-based technologies. With the incorporation of several microfluidic devices, a charge-switchable, magnetic bead was used to extract gDNA released from the buccal cells in the saliva samples and collected by a built-in microcoils array. A new normally-closed micropump for liquid delivery and a new self-compensated micro temperature control module for on-chip PCR were all integrated into a single chip. Successful demonstration for detection of the patients with genetic deletion has been achieved by using the proposed microfluidic platform. Consequently, the integrated miniature saliva-based microfluidic system can provide a promising platform for rapid DNA extraction and fast detection of genetic diseases in a shorter period of time automatically.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"247 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123390198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Surface-Temperature Control of Silicon Nanowires in Dry and Liquid Conditions 干燥和液体条件下硅纳米线的表面温度控制
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805445
Shoichi Akiyama, Y. T. Cheng, J. Fattaccioli, N. Takama, Peter Löw, C. Bergaud, Beomjoon Kim
{"title":"Surface-Temperature Control of Silicon Nanowires in Dry and Liquid Conditions","authors":"Shoichi Akiyama, Y. T. Cheng, J. Fattaccioli, N. Takama, Peter Löw, C. Bergaud, Beomjoon Kim","doi":"10.1109/MEMSYS.2009.4805445","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805445","url":null,"abstract":"In this paper we present the results of surface temperature control of silicon nanowires by using fluorescent thermometry at the nanometer scale. Rhodamine B is one of the stable fluorescent molecules, which rely on the characteristic of temperature-dependent change in fluorescent intensity, and it was used for nano-scale surface temperature sensing interface. The resistive heating on Si nanowires was carried out with applying voltage potential of 6 ~ 12 V. Surface-temperature measurement was performed by converting the changes in fluorescent intensity with calibration curve of Rhodamine B. The temperature at the central line along nanowires increasing from 30 degrees to 35~70 degrees was observed.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123560802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Piezoresistive Cantilever-based Force-Clamp System for the Study of Mechanotransduction in C. Elegans 基于压阻悬臂力夹紧系统的秀丽隐杆线虫力学转导研究
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems Pub Date : 2009-03-27 DOI: 10.1109/MEMSYS.2009.4805350
S.-J. Park, B. Petzold, M. Goodman, B. Pruitt
{"title":"Piezoresistive Cantilever-based Force-Clamp System for the Study of Mechanotransduction in C. Elegans","authors":"S.-J. Park, B. Petzold, M. Goodman, B. Pruitt","doi":"10.1109/MEMSYS.2009.4805350","DOIUrl":"https://doi.org/10.1109/MEMSYS.2009.4805350","url":null,"abstract":"Understanding how the mechanoreceptor neurons of Caenorhabditis elegans mediate mechanotransduction can unravel how touch works, but new tools are required to quantitatively analyze the relationship between mechanical loading and the physiological response. Here we present a piezoresistive cantilever-based force clamp system that can apply user-defined force profiles to C. elegans. We present a novel MEMS force-clamp system and demonstrate a piezoresistive cantilever with low 1/f noise, low noise floor and high force resolution suitable for these measurements. Initial studies enabled by the system are also discussed.","PeriodicalId":187850,"journal":{"name":"2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128297672","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信