Mass spectrometry最新文献

筛选
英文 中文
Evaluation for Ion Heating of H2A-H2B Dimer in Ion Mobility Spectrometry-Mass Spectrometry. 离子迁移率质谱法中H2A-H2B二聚体离子加热的评价。
Mass spectrometry Pub Date : 2023-01-01 Epub Date: 2023-10-17 DOI: 10.5702/massspectrometry.A0131
Kazumi Saikusa, Daiki Asakawa, Sotaro Fuchigami, Satoko Akashi
{"title":"Evaluation for Ion Heating of H2A-H2B Dimer in Ion Mobility Spectrometry-Mass Spectrometry.","authors":"Kazumi Saikusa,&nbsp;Daiki Asakawa,&nbsp;Sotaro Fuchigami,&nbsp;Satoko Akashi","doi":"10.5702/massspectrometry.A0131","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0131","url":null,"abstract":"<p><p>Ion mobility spectrometry-mass spectrometry (IMS-MS) provides <i>m/z</i> values and collision cross sections (CCSs) of gas-phase ions. In our previous study, an intrinsically disordered protein, the H2A-H2B dimer, was analyzed using IMS-MS, resulting in two conformational populations of CCS. Based on experimental and theoretical approaches, this resulted from a structural diversity of intrinsically disordered regions. We predicted that this phenomenon is related to ion heating in the IMS-MS instrument. In this study, to reveal the effect of ion heating from parameters in the IMS-MS instrument on the conformational population of the H2A-H2B dimer, we investigated the arrival time distributions of the H2A-H2B dimer by changing values of three instrumental parameters, namely, cone voltage located in the first vacuum chamber, trap collision energy (trap CE) for tandem mass spectrometry, and trap bias voltage for the entrance of IMS. These results revealed that the two populations observed for the H2A-H2B dimer were due to the trap bias voltage. Furthermore, to evaluate the internal energies of the analyte ions with respect to each parameter, benzylpyridinium derivatives were used as temperature-sensitive probes. The results showed that the trap CE voltage imparts greater internal energy to the ions than the trap bias voltage. In addition, this slight change in the internal energy caused by the trap bias voltage resulted in the structural diversity of the H2A-H2B dimer. Therefore, the trap bias voltage should be set with attention to the properties of the analytes, even if the effect of the trap bias voltage on the internal energy is negligible.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"12 1","pages":"A0131"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c2/26/massspectrometry-12-1-A0131.PMC10582283.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49679298","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Carotenoids: Distribution, Function in Nature, and Analysis Using LC-Photodiode Array Detector (DAD)-MS and MS/MS System. 类胡萝卜素:分布、在自然界中的作用和使用LC光电二极管阵列检测器(DAD)-MS和MS/MS系统的分析。
Mass spectrometry Pub Date : 2023-01-01 Epub Date: 2023-11-01 DOI: 10.5702/massspectrometry.A0133
Takashi Maoka
{"title":"Carotenoids: Distribution, Function in Nature, and Analysis Using LC-Photodiode Array Detector (DAD)-MS and MS/MS System.","authors":"Takashi Maoka","doi":"10.5702/massspectrometry.A0133","DOIUrl":"10.5702/massspectrometry.A0133","url":null,"abstract":"<p><p>Carotenoids are tetraterpene pigments that are present in photosynthetic bacteria, some species of archaea and fungi, algae, plants, and animals. Carotenoids are essential pigments in photosynthetic organs along with chlorophylls. Carotenoids also act as photo-protectors, antioxidants, color attractants, and precursors of plant hormones in plants. Carotenoids in animals play important roles, such as precursors of vitamin A, photo-protectors, antioxidants, enhancers of immunity, and contributors to reproduction. More than 850 kinds of carotenoids are present in nature. The structures are similar and all of them are labile. Analysis of natural carotenoids requires the establishment of reliable methods for analyzing them. Liquid chromatography-mass spectrometry (LC-MS) and mass spectrometry/mass spectrometry (MS/MS) coupled with photodiode array detector (DAD) is an important tool for analysis of natural carotenoids. Electrospray ionization and atmospheric pressure chemical ionization are commonly used for ionization of LC-MS of carotenoids. MS and MS/MS provide not only molecular weight information but also some structural information on carotenoids. Ultraviolet-visible spectra from DAD provide information on chromophore systems, which cannot be provided by MS spectral data. In the present review, I report the structural diversity and function of natural carotenoids, and also describe the techniques for analysis of natural carotenoids using the LC-DAD-MS and MS/MS system.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"12 1","pages":"A0133"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10626154/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71483287","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comments on "Identification of Negative Ion at m/z 20 Produced by Atmospheric Pressure Corona Discharge Ionization under Ambient Air". 关于 "常压电晕放电电离在环境空气中产生的 m/z 20 负离子的鉴定 "的评论
Mass spectrometry Pub Date : 2023-01-01 Epub Date: 2023-12-28 DOI: 10.5702/massspectrometry.A0140
Daiki Asakawa, Kenzo Hiraoka
{"title":"Comments on \"Identification of Negative Ion at <i>m/z</i> 20 Produced by Atmospheric Pressure Corona Discharge Ionization under Ambient Air\".","authors":"Daiki Asakawa, Kenzo Hiraoka","doi":"10.5702/massspectrometry.A0140","DOIUrl":"10.5702/massspectrometry.A0140","url":null,"abstract":"","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"12 1","pages":"A0140"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10774506/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139403559","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Recent Advances and Applications of Ambient Mass Spectrometry Imaging in Cancer Research: An Overview. 环境质谱成像在癌症研究中的最新进展和应用综述。
Mass spectrometry Pub Date : 2023-01-01 Epub Date: 2023-09-28 DOI: 10.5702/massspectrometry.A0129
Bharath S Kumar
{"title":"Recent Advances and Applications of Ambient Mass Spectrometry Imaging in Cancer Research: An Overview.","authors":"Bharath S Kumar","doi":"10.5702/massspectrometry.A0129","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0129","url":null,"abstract":"<p><p>Cancer metabolic variability has a significant impact on both diagnosis and treatment outcomes. The discovery of novel biological indicators and metabolic dysregulation, can significantly rely on comprehension of the modified metabolism in cancer, is a research focus. Tissue histology is a critical feature in the diagnostic testing of many ailments, such as cancer. To assess the surgical margin of the tumour on patients, frozen section histology is a tedious, laborious, and typically arbitrary method. Concurrent monitoring of ion images in tissues facilitated by the latest advancements in mass spectrometry imaging (MSI) is far more efficient than optical tissue image analysis utilized in conventional histopathology examination. This article focuses on the \"desorption electrospray ionization (DESI)-MSI\" technique's most recent advancements and uses in cancer research. DESI-MSI can provide wealthy information based on the variances in metabolites and lipids in normal and cancerous tissues by acquiring ion images of the lipid and metabolite variances on biopsy samples. As opposed to a systematic review, this article offers a synopsis of the most widely employed cutting-edge DESI-MSI techniques in cancer research.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"12 1","pages":"A0129"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/75/d3/massspectrometry-12-1-A0129.PMC10542858.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41139614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Estimation of the Spatial Extent of the Transient Gain Drop in a Microchannel Plate. 微通道板瞬态增益下降空间范围的估计。
Mass spectrometry Pub Date : 2023-01-01 Epub Date: 2023-11-07 DOI: 10.5702/massspectrometry.A0134
Hiroshi Kobayashi, Toshinobu Hondo, Yasuo Kanematsu, Motohiro Suyama, Michisato Toyoda
{"title":"Estimation of the Spatial Extent of the Transient Gain Drop in a Microchannel Plate.","authors":"Hiroshi Kobayashi, Toshinobu Hondo, Yasuo Kanematsu, Motohiro Suyama, Michisato Toyoda","doi":"10.5702/massspectrometry.A0134","DOIUrl":"10.5702/massspectrometry.A0134","url":null,"abstract":"<p><p>The gain of the microchannel plate temporally drops after an ion initiates an electron avalanche. Electron multiplication was expected to deplete the charge from the microchannel wall and produce the depleted charge (wall charge). Moreover, it was reported that the gain drop occurred not only in the activated channels, where the electrons are multiplied, but also in the surrounding channels. One mechanism of the gain-drop spatial extension has been considered as that the wall charges in the activated channels change the electric field in the surrounding channels. Anacker <i>et al</i>. assumed that the wall charge is a uniform line charge; the gain-drop spatial extent should be proportional to the amount of the wall charges. We considered that the wall charges exponentially increased in the channel toward the exit. In this study, the electric field produced by the wall charges was calculated, considering the distribution of the wall charges. The transverse electric field generated by the wall charges was expected to disturb the electron trajectory near the channel exit and decrease the number of secondary electrons emitted per collision (gain per collision), resulting in a gain drop. The gain per collision was calculated to decrease by 22% for the position where the gain decreased significantly in the presence of the transverse electric field of 3×10<sup>5</sup> V/m. In our model, the gain-drop spatial extent extended proportionally to the square root of the wall charges when the distance from the activated channel exceeded 50 μm.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"12 1","pages":"A0134"},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10632093/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89718843","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fragmentation and Ionization Efficiency of Positional and Functional Isomers of Paeoniflorin Derivatives in Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry 基质辅助激光解吸/电离飞行时间质谱分析芍药苷衍生物位置和功能异构体的碎片化和电离效率
Mass spectrometry Pub Date : 2022-02-28 DOI: 10.5702/massspectrometry.A0101
T. Yamagaki, Kohtaro Sugahara, K. Fujikawa, Kazuto Washida
{"title":"Fragmentation and Ionization Efficiency of Positional and Functional Isomers of Paeoniflorin Derivatives in Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry","authors":"T. Yamagaki, Kohtaro Sugahara, K. Fujikawa, Kazuto Washida","doi":"10.5702/massspectrometry.A0101","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0101","url":null,"abstract":"Paeoniflorin and albiflorin, which are functional isomers, are the major constituents of an herbal medicine derived from Paeonia lactiflora. Those functional isomers and their galloylated derivatives, which are positional isomers, were studied by matrix-assisted laser desorption/ionization–tandem mass spectrometry (MALDI-MS/MS). The resulting mass spectra are discussed based on the fragmentation patterns of the sodium adducts. The product ion spectra of 4-O-galloylalbiflorin and 4′-O-galloylpaeoniflorin differed, even though they were positional isomers. The fragmentations of the ester parts were influenced by the neighboring hydroxyl groups. The ionization efficiency of the sodium adduct of albiflorin was higher than that for paeoniflorin. These results indicate that the carboxylic ester group has a higher affinity for sodium ions than the acetal group, which can be attributed to the carbonyl oxygen being negatively polarized, allowing it to function as a Lewis base.","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89646098","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Mass Spectrometry Imaging 质谱成像
Mass spectrometry Pub Date : 2022-02-25 DOI: 10.5702/massspectrometry.A0102
S. Shimma
{"title":"Mass Spectrometry Imaging","authors":"S. Shimma","doi":"10.5702/massspectrometry.A0102","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0102","url":null,"abstract":"Mass spectrometry imaging (MSI) is a technique for obtaining information on the distribution of various molecules by performing mass spectrometry directly on the sample surface. The applications range from small molecules such as lipids to large molecules such as proteins. It is also possible to detect pharmaceuticals and elemental isotopes in interstellar matter. This review will introduce various applications of MSI with examples.","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"273 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77551152","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Electrospray Ionization Mass Spectrometry of Apolipoprotein CIII to Evaluate O-glycan Site Occupancy and Sialylation in Congenital Disorders of Glycosylation. 利用载脂蛋白 CIII 的电喷雾离子化质谱法评估先天性糖基化紊乱的 O-聚糖位点占用率和 Sialylation。
Mass spectrometry Pub Date : 2022-01-01 Epub Date: 2022-08-10 DOI: 10.5702/massspectrometry.A0104
Yoshinao Wada, Nobuhiko Okamoto
{"title":"Electrospray Ionization Mass Spectrometry of Apolipoprotein CIII to Evaluate <i>O</i>-glycan Site Occupancy and Sialylation in Congenital Disorders of Glycosylation.","authors":"Yoshinao Wada, Nobuhiko Okamoto","doi":"10.5702/massspectrometry.A0104","DOIUrl":"10.5702/massspectrometry.A0104","url":null,"abstract":"<p><p>Congenital disorders of glycosylation (CDG) are inherited metabolic diseases that affect the synthesis of glycoconjugates. Defects in mucin-type <i>O</i>-glycosylation occur independently or in combination with <i>N</i>-glycosylation disorders, and the profiling of the <i>O</i>-glycans of apolipoprotein CIII (apoCIII) by mass spectrometry (MS) can be used to support a diagnosis. The biomarkers are site occupancy and sialylation levels, which are indicated by the content of non-glycosylated apoCIII0a isoform and by the ratio of monosialylated apoCIII1 to disialylated apoCIII2 isoforms, respectively. In this report, electrospray ionization (ESI) quadrupole MS of apoCIII was used to identify these biomarkers. Among the instrumental parameters, the declustering potential (DP) induced the fragmentation of the <i>O</i>-glycan moiety including the Thr-GalNAc linkage, resulting in an increase in apoCIII0a ions. This incurs the risk of creating a false positive for reduced site occupancy. The apoCIII1/apoCIII2 ratio was substantially unchanged despite some dissociation of sialic acids. Therefore, appropriate DP settings are especially important when transferrin, which requires a higher DP, for <i>N</i>-glycosylation disorders is analyzed simultaneously with apoCIII in a single ESI MS measurement. Finally, a reference range of diagnostic biomarkers and mass spectra of apoCIII obtained from patients with SLC35A1-, TRAPPC11-, and ATP6V0A2-CDG are presented.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":" ","pages":"A0104"},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9396207/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40346745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrospray Ionization Mass Spectrometry of Transferrin: Use of Quadrupole Mass Analyzers for Congenital Disorders of Glycosylation. 转铁蛋白的电喷雾电离质谱分析:四极杆质谱分析仪用于先天性糖基化疾病。
Mass spectrometry Pub Date : 2022-01-01 Epub Date: 2022-04-15 DOI: 10.5702/massspectrometry.A0103
Yoshinao Wada, Nobuhiko Okamoto
{"title":"Electrospray Ionization Mass Spectrometry of Transferrin: Use of Quadrupole Mass Analyzers for Congenital Disorders of Glycosylation.","authors":"Yoshinao Wada,&nbsp;Nobuhiko Okamoto","doi":"10.5702/massspectrometry.A0103","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0103","url":null,"abstract":"<p><p>Electrospray ionization (ESI) mass spectrometry of transferrin can be used to diagnose congenital disorders of glycosylation (CDG) by detecting abnormal <i>N</i>-glycosylation due to reduced site occupancy or processing failure. Time-of-flight mass spectrometers are widely used to separate 25-45 charged ions in the <i>m</i>/<i>z</i> 1,700-3,000 range, and a summed zero-charge mass distribution is generated despite the risk of improper deconvolution. In this study, the low <i>m</i>/<i>z</i> region of the multiply-charged ion mass spectrum enabled a robust analysis of CDG. A triple quadrupole mass spectrometer, the standard instrument for newborn screening for inborn errors of metabolism, permitted the identification of the key ions characteristic of different types of CDG affecting <i>PMM2</i>, <i>ALG14</i>, <i>SLC35A1</i>, <i>SLC35A2</i>, <i>MAN1B1</i> and <i>PGM1</i> in the <i>m</i>/<i>z</i> 1,970-2,000 region. Charge deconvolution was used as a complementary tool for validating the findings. It was necessary to set a cutoff level for the evaluation, since small peaks indicating glycosylation failure or reduced sialylation were observed, even in control subjects. This method and workflow facilitates the implementation of MS-based analyses and the screening of CDG in clinical laboratories.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":" ","pages":"A0103"},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9395324/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40346746","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Improvement in Ionization Efficiency Using Metal Oxide Nanoparticles in Laser Desorption/Ionization Mass Spectrometry of a Cancer Drug. 金属氧化物纳米粒子在抗癌药物激光解吸/电离质谱分析中提高电离效率。
Mass spectrometry Pub Date : 2021-01-01 Epub Date: 2021-12-23 DOI: 10.5702/massspectrometry.A0099
Hiroki Kannen, Yuto Miyoshi, Hisanao Hazama, Kunio Awazu
{"title":"Improvement in Ionization Efficiency Using Metal Oxide Nanoparticles in Laser Desorption/Ionization Mass Spectrometry of a Cancer Drug.","authors":"Hiroki Kannen,&nbsp;Yuto Miyoshi,&nbsp;Hisanao Hazama,&nbsp;Kunio Awazu","doi":"10.5702/massspectrometry.A0099","DOIUrl":"https://doi.org/10.5702/massspectrometry.A0099","url":null,"abstract":"<p><p>Mass spectrometry imaging (MSI) without labeling has the potential for faster screening in drug development. Matrix-assisted laser desorption/ionization (MALDI) is typically used, but it has a large matrix size and uneven drug distribution. Surface-assisted laser desorption/ionization (SALDI) using nanoparticles (NPs) may overcome these issues. Here, the influence of NPs, solvent ratio, and order of dropping of NPs on SALDI-MSI of protoporphyrin IX (PpIX), a cancer drug, are reported. A solution of PpIX in a 50% aqueous solution of 50% acetonitrile at a concentration of 10 μM was used. The NPs include ZnO, Fe<sub>3</sub>O<sub>4</sub>, and four types of TiO<sub>2</sub>. The NPs were fabricated by dissolving them on an aqueous 90% acetonitrile solution. Mass spectra were obtained with a time-of-flight mass spectrometer using a Nd:YAG laser at a 355-nm wavelength. The signal intensity using TiO<sub>2</sub> at a 0.5 mg/mL concentration in 50% acetonitrile was increased by 1.6-fold compared to that without TiO<sub>2</sub>. Changing the solvent to 90% acetonitrile gave a uniform TiO<sub>2</sub> distribution and a 9-fold increase in the signal intensity for PpIX. Among the four types of TiO<sub>2</sub> with different particle sizes and crystal structures, TiO<sub>2</sub> with a smaller particle size and a rutile crystal structure produced the highest signal intensity. Forming a layer on top of the PpIX also resulted in an increased signal intensity. Hence, SALDI using TiO<sub>2</sub> provides effective ionization of the drug. In the future, we plan to investigate a spray method for the ionization of PpIX using TiO<sub>2</sub> for the MSI of various drugs.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"10 1","pages":"A0099"},"PeriodicalIF":0.0,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697360/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39792149","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信