{"title":"Research on the AGV Based Robot System Used in Substation Inspection","authors":"Shengfang Li, Xingzhe Hou","doi":"10.1109/ICPST.2006.321495","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321495","url":null,"abstract":"At the present time, substation equipments are inspected one by one by electric power workers in our country. It not only costs much manpower and material resources, but is also inefficient and insecure. The laser guided AGV based robot system used in substation inspection is a much better choice to solve the above problems. AGV, namely automatic guided vehicle, is a kind of simple mobile robot, which integrates sound, light, electricity and computer. And it is applied in the fields of industry manufacture and logistics widely and maturely. Improving the laser guided AGV in configuration, location, run and control software and so on combined with the requirement of substation operating standard, and then the improved AGV can be used in automatic inspection of substation equipments. The paper introduces the theory and application of laser guided AGV briefly, analyses the feasibility of improving AGV to meet the requirements of field environment and operation standard of substation, and then the design scheme of AGV based robot system used in substation equipment inspection is brought forward. The robot system can replace workers to inspect equipments in substation automatically or remote-controlled, and the operation automation of substation is improved to a new level. Accordingly, the application in substation inspection of the robot system based on laser guided AGV has notable economical benefits and social significance.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115410063","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research of Out-of-Step Protection System Based on Wide Area Measure System","authors":"Xiying Chen, Weixing Li, He Chen, Zhizhong Guo","doi":"10.1109/ICPST.2006.321823","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321823","url":null,"abstract":"Out-of-step protection is the worst situation to prevent a power system from collapse in the large-size connection electrified wire netting. If no methods adopted to deal with it, the power grid will blackout. So we must choose the right criteria to detect the synchronization loss, do well with the coordination methods and select the situation and the time to trip the generators. This paper outlines several criteria for detecting the synchronization loss and gives the advantages, disadvantages. It points out that it is worth to adopt ameliorated UCOS Phi criteria based on WAMS. The separate situation is at the connected with lines that the oscillation center located in, not but at the power balance spot. We should do our best to leave the load of related substation in the delivery end. The best separate time is at the soon an oscillation cycle ends because here the electric current of the break implement opening and break off is the least and its concussion is the least. We choose the best separate time at 2~3 oscillation cycle for lower voltage electrified wire netting. For 500 kV electrified wire netting we must separate it as soon as 1~2 oscillation cycle. Now WAMS can commute states and dates every 1.666 ms used light communications, it helps for studied on out-of-step and corresponded in total power grid on hardware. The result indicates that wide area measure system based realtime measure and faced entirely course for power grid is the best direction.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"1031 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123127260","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Process-oriented State Estimation using Innovation Network Graph Based PMUs","authors":"H. Bai, Zhizhong Guo, Lin Zhao, Yu Gao, He Chen","doi":"10.1109/ICPST.2006.321729","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321729","url":null,"abstract":"The advent of PMU-based WAMS provides a chance to improve the traditional state estimation, AC load flow model innovation (network) graph state estimation based PMUs is a new but effective estimation algorithm. By using it, this paper carries out process-oriented state estimation using all the measurements within a period of time, which can provide characteristic states within a process of time. In order to develop the new method, the operating process is divided into several processes and sub-processes according to the topology change. In each process or sub-process, a characteristic state is derived which can represent the average status of this process or sub- process. In order to compute the expected states, an expected innovation network graph is derived. The IEEE-5 bus system is used to illustrate the effectiveness of the new method.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124258997","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An Improved Power Transformer Diagnosis System for Incipient Fault Based on Fuzzy Rough Set Theory","authors":"Xiong Hao, Lin Weiguo, Chang Guanghui, Gu Huimin","doi":"10.1109/ICPST.2006.321559","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321559","url":null,"abstract":"Based on fuzzy rough set theory (FRS), the paper is meant to present a new diagnosis system with gas ratios method for transformer incipient fault diagnosis, which not only has the capability of coping with incomplete information inputting and rules reduction just as in conventional rough set theory (RS), but also has the capability of fuzzification of thresholds of continuous values of attributes. Since strict thresholds setting is said to undergo the diagnosis effectiveness, A method of fuzzy subsets extraction from database based on KDD technology is employed to the setting attributes, which improve the power of prevailing IEC/IEEE criteria in fields of strict thresholds setting. Finally, results of testing the proposed diagnosis system on actual dissolved gas records are addressed, which confirmed that rules represented by fuzzy terms and extracted based on FRS allow diagnosis results to be satisfied, and diagnosis system proposed can provide a satisfactory accuracy.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"138 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125214934","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ma Wen-chuan, Mu Xianmin, Wang Jian-ze, J. Yanchao
{"title":"Design of a Novel Voltage Supply Applied for Measure System of High Voltage Side in Power System","authors":"Ma Wen-chuan, Mu Xianmin, Wang Jian-ze, J. Yanchao","doi":"10.1109/ICPST.2006.321867","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321867","url":null,"abstract":"A current/voltage supply is presented based on the technology of PWM. It adopts GTR as the shunt. It can convert the current supply that is generated by 220 v alternating voltage to a voltage supply with low heat rate and stable output voltage. This power supply is especially adapted to be used as the power supply for measure system of a high voltage side in power system. The operating principle of the circuit and the pivotal technology are analyzed, and the simulating and experimental results are also given in this paper.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116692100","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Studies on Substation Voltage and Reactive Power Automatic Regulating Criteria","authors":"Jiwen Li, Xuelian Liu, Yubin Wang, Hongmei Li","doi":"10.1109/ICPST.2006.321562","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321562","url":null,"abstract":"This paper suggests a new criterion for substation voltage regulation and reactive power automatic regulation, which introduces voltage status into reactive power regulation criterion, making the reactive power regulation boundary a fuzzy one variable with voltage status. Being agreeable to human judgement, this criterion can improve compensation effects and effective in keeping a stable voltage and reducing the number of on-load tapping switch adjustments.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116762874","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Security Coordinated Economic Dispatch for Joint Energy and Reserve Markets","authors":"J. Xin, E. Bompard, R. Napoli","doi":"10.1109/ICPST.2006.321848","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321848","url":null,"abstract":"In power markets, SO can maintain system security by preventively restraining the energy transactions or, if having procured sufficient reserves, by dispatching the reserves correctively after any contingency happens. The traditional security constrained unit commitment (SCUC) or economic dispatch (SCED), being with all the contingency constraints, probably leads to lower market efficiency. In this paper, a security coordinated economic dispatch (SCoED) model is presented for day-ahead energy and reserve joint market, which is formulated as a Stackelberg leader-follower problem, the upper level determining the energy and reserve procurement schedules subjecting to only the normal constraints while in the lower level, economic dispatch of the procured reserves is executed for every possible N-l contingency to maintain system security. A numerical example is carried out on a 6-bus system to compare the energy market efficiency and reserve procurement cost under the traditional SCED and the SCoED.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121045735","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of Battery System for Frequency Control in Interconnected Power System with a Large Penetration of Wind Power Generation","authors":"M. Arita, A. Yokoyama, Y. Tada","doi":"10.1109/ICPST.2006.321682","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321682","url":null,"abstract":"Recently, a lot of distributed generations such as wind power generation are going to be installed into power systems. However, the fluctuation of these generator outputs affects the system frequency. Therefore, introduction of battery system to the power system has been considered in order to suppress the fluctuation of the total power output of the distributed generation. For frequency analysis, we use the interconnected 2-area power system model. It is assumed that a small control area with a large penetration of wind power plants is interconnected into a large control area. In this system, the tie line power fluctuation is very large as well as the system frequency fluctuation. It is shown that the installed battery can suppress these fluctuations and that the effect of battery on suppression of fluctuations depends on the battery capacity. Then, the required battery capacity for suppressing the tie line power deviation within a given level is calculated.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127118817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Q. F. Liao, D.C. Liu, L. Ying, X. Cui, Y. Li, W.T. He
{"title":"Parameter Identification of Excitation Systems Based on Hopfield Neural Network","authors":"Q. F. Liao, D.C. Liu, L. Ying, X. Cui, Y. Li, W.T. He","doi":"10.1109/ICPST.2006.321809","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321809","url":null,"abstract":"The parameter identification based on Hopfield neural network (HNN) was applied to a static excitation system. The applicable algorithm of the identification method was given in detail. Nine-parameter excitation system was studied. The HNN of twenty neurons were designed in order to identify these parameters. Finally model validation was performed. Numerical simulation results testify that this method has high precision and quick convergence. The method can be implemented with electronic circuit, so it will benefit the on-line parameter identification of the excitation system and will have significance to any system that can be described by state space model.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127293971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measured Impedance by Distance Relay Considering Double Model of the Line Capacitance","authors":"S. Jamali, H. Shateri","doi":"10.1109/ICPST.2006.321903","DOIUrl":"https://doi.org/10.1109/ICPST.2006.321903","url":null,"abstract":"This paper investigate the measured impedance by distance relay considering the transmission line capacitance by utilizing a double pi model for the line. The distance relay ideal tripping characteristic is therefore presented. The measured impedance and the tripping characteristic are compared with those in the case of not considering the line capacitance. In the case of zero fault resistance, the deviation of the measured impedance from its exact value caused by the line capacitance is also investigated.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127433574","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}