{"title":"Evaluation of Battery System for Frequency Control in Interconnected Power System with a Large Penetration of Wind Power Generation","authors":"M. Arita, A. Yokoyama, Y. Tada","doi":"10.1109/ICPST.2006.321682","DOIUrl":null,"url":null,"abstract":"Recently, a lot of distributed generations such as wind power generation are going to be installed into power systems. However, the fluctuation of these generator outputs affects the system frequency. Therefore, introduction of battery system to the power system has been considered in order to suppress the fluctuation of the total power output of the distributed generation. For frequency analysis, we use the interconnected 2-area power system model. It is assumed that a small control area with a large penetration of wind power plants is interconnected into a large control area. In this system, the tie line power fluctuation is very large as well as the system frequency fluctuation. It is shown that the installed battery can suppress these fluctuations and that the effect of battery on suppression of fluctuations depends on the battery capacity. Then, the required battery capacity for suppressing the tie line power deviation within a given level is calculated.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2006.321682","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34
Abstract
Recently, a lot of distributed generations such as wind power generation are going to be installed into power systems. However, the fluctuation of these generator outputs affects the system frequency. Therefore, introduction of battery system to the power system has been considered in order to suppress the fluctuation of the total power output of the distributed generation. For frequency analysis, we use the interconnected 2-area power system model. It is assumed that a small control area with a large penetration of wind power plants is interconnected into a large control area. In this system, the tie line power fluctuation is very large as well as the system frequency fluctuation. It is shown that the installed battery can suppress these fluctuations and that the effect of battery on suppression of fluctuations depends on the battery capacity. Then, the required battery capacity for suppressing the tie line power deviation within a given level is calculated.