{"title":"Controlling the Reactive Power of the Enterprise’s Power Supply System with the Task Correction According to the Current Calculation Meter Readings","authors":"V. I. Kotenev, Aleksandr D. Stulov","doi":"10.1109/UralCon52005.2021.9559543","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559543","url":null,"abstract":"The industrial enterprise’s power supply system (PSS) reactive power (RP) automated control system (ACS) has been considered, comprising workshop transformer substations with capacitor units and the main step-down substation, from which synchronous motors are powered. The use of this control system allows meeting the regulatory requirements for ensuring the limiting RP factor values and thereby reducing loss when transmitting power and increasing the grid throughput. A mathematical model of a power transformer has been obtained, based on which a structural diagram of a PSS controlled by the RP factor built. Typical ACSs have been considered to control reactive power on the low voltage side of the transformer, from which RP sources are powered: control systems with standard power factor regulators and ACSs with algorithms formed as a function of active and reactive power of power consumers. A system to control the RP factor of the PSS of the entire enterprise has been proposed with the task correction as a function of the current calculation meter readings. The performance of the control systems proposed has been confirmed on an experimental unit with asynchronous and synchronous machines. The control system considered can be used at many industrial enterprises with capacitor units and asynchronous and synchronous motors.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133831279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Combined Equivalent Circuit of a Single-Circuit Power Transmission Line with a Ground Wire","authors":"E. Panova","doi":"10.1109/UralCon52005.2021.9559485","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559485","url":null,"abstract":"The paper presents a combined equivalent circuit for a single-circuit power transmission line with a ground wire. This mathematical model combines the advantages of the methods of phase coordinates and symmetric components. It makes it possible to take into account the asymmetrical arrangement of phase wires and a lightning protection cable on the tower, which is important for the correct determination of the mutual induction impedances and power transmission line capacitance. In this case, there is no need to simulate the entire electrical circuit in phase coordinates, which greatly simplifies the calculations. The results of calculating the parameters of the equivalent circuit of power transmission lines using the proposed equations showed their proximity to the reference data.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134180520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. M. Safonov, N. N. Fedortsov, N. Dulnev, D. A. Blagodarov
{"title":"The Predictive Diagnosis Method of Electric Drive State Via an Artificial Neural Network","authors":"Y. M. Safonov, N. N. Fedortsov, N. Dulnev, D. A. Blagodarov","doi":"10.1109/UralCon52005.2021.9559510","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559510","url":null,"abstract":"This paper proposes a method of diagnosing the state of electric drive and/or its elements via an artificial neural network in real-time. The proposed method used pre-installed sensors by manufacturers. Additional sensors or devices are not needed to implement this method. The paper considers the relevance of this topic, describes the advantages of the method, explains the algorithm of work. The necessity of using the artificial neural network (ANN) is justified. The obtained ANN trained on data taken from real objects. The data of the training sample are trends values get from sensors during commissioning. Theoretical calculations are confirmed by experimental data. Special attention is paid to the scope proposed method.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"86 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132852721","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Thyristors Balancing Voltage Regulator with Boost Voltage","authors":"Viktor V. Kokh, M. I. Petrov, Dmitry V. Mostovoy","doi":"10.1109/UralCon52005.2021.9559603","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559603","url":null,"abstract":"This paper examines the problems of improving the power supply quality in four-wire distribution networks of 0.4 kV. The reasons leading to the quality deterioration of the electricity supplied to the consumer are considered. −The operation of known voltage regulators providing stabilization and balancing load voltage is analyzed, their advantages and disadvantages are shown. A new approach to the development of regulator for balancing power supply currents and voltages of the loads based on boost voltage is proposed. The mathematical analysis of electromagnetic processes of proposed devices illustrating efficiency of their work is shown. As an example, the effectiveness of the device installed in a network with an asymmetrical three-phase load is demonstrated.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133169634","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Merging Roles in the Production of Massive Online Electric Drive Courses","authors":"A. Kazak, N. Oleinikov, D. Samokhvalov","doi":"10.1109/UralCon52005.2021.9559418","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559418","url":null,"abstract":"The concept of merging the roles of producers of online courses is considered. It is relevant if it is necessary to quickly develop online training courses on electric drive or when converting a full-time training course into a hybrid format. The economic and technological aspects of the proposed approach are considered. Authors' capture of all the roles required to produce online courses can reduce costs and, in some cases, even improve product quality. To capture all the functions necessary for production, authors must master the technologies of capturing video from a computer screen, editing video, recording sound, editing audio tracks. To study modern electromechanical systems and electric drive control systems, knowledge of electrical machines, power electronics and control theory is required. When preparing online courses on electric drive, it is imperative to include practical exercises that are implemented using the Simulink or SimInTech visual modeling environments.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114989792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Neuro Algorithm Accuracy Evaluation for The Anomalies Detecting in Overcurrent Protection Operation","authors":"S. Ivanov, Maxim V. Nikandrov, A. Lariukhin","doi":"10.1109/UralCon52005.2021.9559614","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559614","url":null,"abstract":"To control information exchange in the digital substation, it is possible to use machine learning methods, the artificial neural networks (ANN), in particular. The ANN training, as a multifactor optimization problem, and its testing make it possible to detect anomalies in information flows and operating modes of the secondary equipment in electric power industries. Using examples for neuro-modeling of overcurrent protection operation mode in a three-phase network, the paper shows the features of a neural network functioning based on an elementary perceptron and estimates the accuracy of the corresponding models. The structure of the simplest neural network is optimized and accuracy evaluation of the neural network algorithm is presented depending on the training sample volume (from 1000 to 50000 records) and the number of training epochs. It was found that neuromodelling makes it possible to evaluate with a high accuracy the value for overcurrent protection adequate trip setting. The deviation range of current values in each phase, when the neural network makes errors in data recognition, does not exceed one percent of the threshold value., The neural network in this range is very \"sensitive\" to changes in input signals. It is shown that if emergency modes with adequate actuation of relay protection are considered as standard secondary equipment operation modes, then neuromodeling and corresponding signal processing make it possible to detect anomalies in the standard secondary equipment operation modes in the electric power system.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117078982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Day-Ahead Solar Irradiance Forecasting Model","authors":"A. F. Narynbaev, A. Vaskov","doi":"10.1109/UralCon52005.2021.9559464","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559464","url":null,"abstract":"The article describes the development of a day-ahead solar irradiance forecasting model in an hourly resolution. A statistical model based on the method of artificial neural networks with a multilayer perceptron architecture was chosen as a forecasting technique. The ground measurements of solar radiation and the weather archive, consisting of the main meteorological quantities, were used for training the model. The selecting of optimal input data combination and hyperparameter tuning were carried out according to the criterion of the minimum error. The developed model on the basis of the multilayer perceptron consists of 5 inputs, 64 neurons in a hidden layer with 1 neuron in the output layer. In the process of predicting the hourly average solar irradiance on a tilted surface, numerical weather forecast data (total cloudiness, air temperature, relative humidity, atmospheric pressure) provided by two different weather services and the cosine of the solar incidence angle as a geometric/temporal parameter were used as the input variables.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"112 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122509049","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Estimation of Deep Bar Induction Motor Equivalent Circuit Parameters from Starting and Load Conditions","authors":"V. Syvokobylenko, S. Tkachenko","doi":"10.1109/UralCon52005.2021.9559583","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559583","url":null,"abstract":"The method for experimental determination of the deep-bar induction motors equivalent circuit parameters from normal operating conditions, such as no-load, starting and operation with various loads has been proposed. In these modes, instantaneous discrete values of currents, stator voltages and slip are measured and stator input resistances are determined, which are used to identify the equivalent circuit parameters of the IM with trapezoidal rotor rods. For the latter, the influence of the skin effect is taken into account using the provided analytical expressions for the skin effect coefficients for resistance and inductive reactance. The advantages of the equivalent circuit with trapezoidal rods in comparison with the generally accepted rectangular ones are shown. The efficiency of the proposed method has been tested for a number of motors via mathematical modeling, as well as according to the experimental data for a 4AZM-5000/6000 type squirrel-cage rotor induction motor with 5000 kW rated power and 6 kV stator voltage. The values of input resistances obtained experimentally and according to the designed equivalent circuit differ by no more than 5%, which makes it possible to recommend the developed method to be used in practice.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128220814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Experience of Using Bluetooth Low Energy to Develop a Sensor Data Exchange System Based on the NRF52832 Microcontroller","authors":"R. Salikhov, V. Abdrakhmanov, T. T. Yumalin","doi":"10.1109/UralCon52005.2021.9559492","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559492","url":null,"abstract":"A brief overview of Bluetooth Low Energy technology is presented: API and built-in data exchange toolkit are considered. The main capabilities of the Bluetooth 5.2 version and the validity of its use in industrial wireless data transmission systems are shown. The idea of creating wireless monitoring systems based on the NRF52832 microcontroller is presented. The technology makes it possible to conveniently implement a data exchange system and includes the necessary tools for its implementation - packet integrity check (CRC), packet delivery check (response), data encryption, automatic retrieval of up-todate data. The experience of development in the Segger Embedded Studio and Xcode environments is shown. The server and client parts of the project have been implemented. Data exchange between devices has been carried out. Considered a development tools for server and client devices. Also in this article, a comparison is made with competing technologies such as ZigBee. In addition, possible industrial applications of the technology were considered.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114137291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Increasing the Reliability of the Centralized Protection of the Digital Substation","authors":"A. Kolesnikov, A. Kulikov, I. Lukicheva","doi":"10.1109/UralCon52005.2021.9559494","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559494","url":null,"abstract":"Double entry is a system of recording business accounting transactions, used for errors detection. The usage of this approach in differential relay protection (DRP) allows to increase the reliability of the protection system. Current signals measured on the ends of protected units are formed in special matrices. The surplus current signal processing ensures reliable DRP functioning and eliminates needless protection actions in cases of current transformer or communication lines faults. The calculated relations of Markov chains are used for reliability indexes estimation. The obtained results allow us to conclude that the implementation of DRP with the usage of the doubly-entry method is promising for the digital substation.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126307842","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}