{"title":"The Induction Motor Model for Control Starting in Small-Scale Power Systems","authors":"A. Fishov, I. Dulov, Roman Khatylenko","doi":"10.1109/UralCon52005.2021.9559568","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559568","url":null,"abstract":"With the development of small-scale generation the issue of conducting reliable starting and preventing stalling of large induction motors in electric power systems with comparable powers becomes especially significant. The conditions of the motor stalling and successful starting in large-scale power systems are well researched. However, those conditions are not acceptable in power systems where generation capacity and induction motors capacity are comparable. Designing automatic devices for successful starting control and preventing stalling of the motor requires the proper models of the critical conditions. Such conditions should consider the predicted variation and current values of voltage, frequency, mechanical torque of the load during motor starting and loading. Application of the critical conditions at the automatic devices allows to prevent initiation of emergency modes in local electric power systems with comparable powers. The successful starting conditions of induction motor and maximum-permissible stability modes for the local electric power systems with the results of the research are presented in the article.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115239322","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Model of the Internal Resistance of the Starter Battery","authors":"Andrey Puzakov","doi":"10.1109/UralCon52005.2021.9559426","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559426","url":null,"abstract":"On-board real-time monitoring of the technical condition of the starter battery is possible if a quantitative change in its parameters is measured during operation. The most informative parameter considering the change in both the terminal voltage and the discharge current is the battery’s internal resistance. To determine the battery’s internal resistance, the locked-gear starter motor loading mode was used. The impact of the electrolyte temperature, operating time, and the states of charge and health on the battery’s internal resistance has been experimentally determined. A mathematical model of the battery’s internal resistance is proposed, considering the change in the operating factors. Practical use of this model will allow onboard determining the technical condition of the battery.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129739243","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Digital Protection and Automation Devices RTDS Model Tests Conducting with Digital Data Transmission Protocols Using","authors":"D. Zolin, E. Ryzhkova","doi":"10.1109/UralCon52005.2021.9559528","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559528","url":null,"abstract":"Methods for modeling power systems modes and testing relay protection devices using real-time modeling complexes and using computer software systems that allow modeling in a conventional time scale are considered. Informational input signals of protection during simulation in the conditional model time mode are obtained in the computational experiment course, and protection devices tests are carried out using hardware-software test complexes using calculated input signals. The power system stability study when changing the generating and consuming electrical equipment modes, the relay protection devices state requires testing using digital simulators in a closed loop mode. At the same time, feedbacks between the power system model operating in real time and external devices or their models should be determined (modeled). Real-time simulation was carried out and an using digital power system simulators for real-time simulation (RTDS simulator) world experience analysis was carried out. RTDS complexes use examples by foreign power companies for testing relay protection and control systems, testing the various equipment and automatic control devices interaction, analyzing cybersecurity and assessing the power systems under emergency situations various scenarios functioning are given. To check the relay protection devices performance without taking into account the power system response, tests can be carried out in an open loop mode using hardware and software test complexes. Methods for testing relay protections and their models in open-loop mode are proposed.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"224 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127190375","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of the System \"Network Analytics\" for Analyzing Data Received from Power System Protection","authors":"I. Kovalev, Maxim Solodkov, Maxim Nenarokomov","doi":"10.1109/UralCon52005.2021.9559590","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559590","url":null,"abstract":"The article discusses the development of the \"Network Analytics\" system for analyzing oscillograms with power system protection, which will automatically collect and aggregate data on a remote server and display possible causes of accidents on power lines based on intelligent analysis. The article provides the structure of the system, the general algorithm of work and describes the main modules. The work algorithms of the module for analyzing emergency data from high voltage stations are shown. A test version of the system based on a user web interface is presented, which displays data in real time from a laboratory stand, as well as displays alarm oscillograms and indicates possible causes of failures.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130480860","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Proposed Plan of a Syrian 400 Kv Grid Connection Model with the DESERTEC Project in the Syrian Arab Republic","authors":"Ibrahim Alwazah, S. N. Tyumentsev, R. Nasyrov","doi":"10.1109/UralCon52005.2021.9559597","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559597","url":null,"abstract":"The continuous increase in the demand for energy in the world has prompted the thinking of using renewable energy sources as an alternative to conventional energy sources (fuel, coal, gas ... etc.) due to the low operating costs and the low impact on the environment. In conjunction with these ideas, several projects appeared in the world that use renewable energies, and one of the most prominent of these projects was the DESERTEC project, which aims to optimize the exploitation of these energies by linking the sources of power generation in the countries of the Middle East, North Africa and Europe with each other through the high voltage direct current. In this paper, a proposal will be presented to plan the connection of the power grid in the Syrian Arab Republic 400 kV that operates on alternating current with the DC network DESERTEC. And studying the effect of this connection on the quality of electrical energy in the Syrian Arab Republic.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125510124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research of the Characteristics of Induction Motor with a Single-Phase Frequency Converter in the Matlab Simulink Environment","authors":"S.Y. Eremochkin, D. Dorokhov","doi":"10.1109/UralCon52005.2021.9559506","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559506","url":null,"abstract":"Three-phase squirrel cage induction motors are widely used in agriculture. This type of motor is used in electric drives of various electrified machines: grinders, pumps, electric saws, etc. In some cases farms are located in remote areas where single-phase power is the most common. In such case the necessity to start and operate a three-phase induction motor from a single-phase power may arise. Thus, an original device that enables to start and operate a three-phase induction motor from a single-phase power has been developed. This article presents the results of a study of the operation of a three-phase induction motor with a single-phase-to-three-phase transistor frequency converter. A simulation model of the developed electric drive was created in the Matlab Simulink environment. For the study, the parameters of a squirrel cage induction motors of the AIS56V4U3 brand were used. A comparison of the characteristics obtained during the operation of an electric drive with a transistor converter and capacitor start.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126053888","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Weighted THD Factors Evaluation of Multilevel Voltage Source Inverter with Space Vector Control under Common-Mode Voltage Elimination","authors":"N. Lopatkin","doi":"10.1109/UralCon52005.2021.9559505","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559505","url":null,"abstract":"The harmonic distortion’s characteristics of the nearest-vector-selecting space vector control with common-mode voltage eliminating technique (CMVE-SVC) for three-phase multilevel voltage source inverter (MLVSI) are explored. The considered CMVE-SVC algorithm applies the particular MLVSI voltage space vectors, which produce the zero value of the common-mode voltage, i.e. the voltage across the load common point and the MLVSI common point. More specifically, the THD of the output phase voltage along with three its weighted THD of low orders are calculated in a virtual instrument of LabVIEW. The simulated dependences on the index of the amplitude modulation of the phase voltage are compared with the dependences of a recently proposed common-mode-voltage-eliminating space vector pulse width modulation technique. The importance of the considered weighted THDs for the load current THD assessment is noted.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116686901","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Mathematical Simulation of a PI Speed Controller for a Separately Excited DC Motor","authors":"A. Semenov, M. Semenova, Y. Bebikhov","doi":"10.1109/UralCon52005.2021.9559518","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559518","url":null,"abstract":"The study is devoted to the mathematical simulation of a PI controller-based DC motor speed control system. DC motors are widely used in the industry to drive cyclic mechanisms requiring high response speed and starting torque, and linear control. The main methods to control the required separately excited DC motor speed characteristics comprise controlling the parameters of the armature and excitation windings powered from different sources. PI controllers are widely used in programmable logic controllers due to the simplicity and clarity of the mathematical tools. The PI controller mathematical model proposed is based on choosing optimal parameters to maintain the actual speed close to the set value. The optimal KP and KI coefficients of the PI controller have been determined, giving the best result for constant speed. The results of computer simulation in MatLab have been compared with that of the laboratory simulation. The data obtained based on the steady-state error and transient time using a PI controller look preferable to the voltage control simulation model. The developed mathematical model has shown the following key results: acceleration time <0.3 s; transient time <0.5 s; overshoot and steady-state error do not exceed 0.5 and 0.1 %, respectively.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116686919","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On Improvement of the Electric Power Quality Control Mechanism in the Energy System of Russia","authors":"V. Chikin, A. Kuznetsov","doi":"10.1109/UralCon52005.2021.9559585","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559585","url":null,"abstract":"In world practice, the power quality in energy systems is regulated administratively and economically. In Russia, the power quality is currently controlled using only administrative methods, which have not yet proven their efficiency. The provisions of the Civil Code of the Russian Federation set out those responsible for the power quality indicators distortion and the parties, affected by such. Thereat, it is not considered that not all indicators characterize power quality as a generating company product supplied to consumers by a power grid company. These include only indicators, that characterize the frequency and voltage deviations from the rates. In such cases the Civil Code of the Russian Federation legal provisions is fully applicable. The energy supplier may not be responsible for the rest of the indicators. The distortion of such indicators, as a rule, is usually caused by the power consumers themselves. The scope of administrative methods regulating the relations between consumers and energy suppliers should be limited to indicators characterizing the frequency and voltage deviations, which can be achieved by amending Article 542 of the Civil Code of the Russian Federation. In case of the interferences caused by the consumption, transmission, and distribution technology specifics, economic methods introducing penalties and bonuses should be applied.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132837673","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Assessment of the Technical and Economic Effect of Automatic Voltage Regulation Devices for 10/0.4 kV Transformers in Power Distribution Networks","authors":"V. Korolev, A. Vanin, A. Chernysheva","doi":"10.1109/UralCon52005.2021.9559501","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559501","url":null,"abstract":"The paper describes the voltage control problem in distribution electrical networks. The negative factors that contribute to the voltage deviation were analyzed. The existing principles of voltage control in electrical distribution networks were considered: centralized automatic regulation and manual seasonal regulation. It was shown that voltage control on the primary substation is not sufficient in case of high network loading, long length of lines and the broad range of load changing. The technical efficiency and economic feasibility of automatic voltage control devices use on 10/0,4 kV transformers for local voltage control were analyzed. The scope of automatic voltage regulators application in the form of semiconductor devices for the transformer output voltage regulation for distribution substations is shown.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134225517","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}