Ilya Petryashin, T. Kartuzova, Alexander Petryashin
{"title":"Simulated Model Relay Protection Training","authors":"Ilya Petryashin, T. Kartuzova, Alexander Petryashin","doi":"10.1109/UralCon52005.2021.9559515","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559515","url":null,"abstract":"The article discusses the task of training relay protection, namely, the task of building the boundaries of the areas of monitored and alternative modes. A method of solving it is proposed, which allows using an object simulation model (IMO) to iteratively identify boundary points of mode regions. The operation of the method is demonstrated by the example of constructing the resistance relay area. Limits of applicability of proposed method are considered, and convergence of iterative process underlying it is also shown. The optimal parameters of the method have been identified, allowing to use it most efficiently.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129875175","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Modified SHMPWM Algorithm based on the 3L-NPC Converter Connected with the 10kV Grid","authors":"Tao Jing, A. Maklakov, A. Radionov, V. Gasiyarov","doi":"10.1109/UralCon52005.2021.9559452","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559452","url":null,"abstract":"Multilevel inverters have recently received increased attention in high-power applications since they can generate high-quality output signals at low switching frequencies. The three-level neutral-point clamped (3L-NPC) inverter is one of multilevel topologies which is formed from the series connection of IGBTs. In order to seek to improve reliability and efficiency of high-power applications, switching losses and total harmonic distortion (THD) should be reduced in power inverters. Pre-programmed pulse width modulation (PWM) methods, such as selective harmonic mitigation (SHMPWM) and selective harmonic elimination (SHEPWM) techniques, can enable the harmonic profile of the output waveform to be preprogrammed over a range of modulation indices. In this paper, a modified SHMPWM control strategy for NPC-based inverter applications is presented to obtain the switching patterns, which is capable of satisfying grid codes under equal dc link voltages. This method is based on the use of feasible solutions near the regions of infeasible solutions to obtain feasible solutions in these regions. Additionally, the adjustment of the safety factors in the mathematical functions of SHMPWM technique is also applied to try to obtain feasible solutions as much as possible. Finally, several simulation results are provided to verify the effectiveness of the proposed SHMPWM algorithm.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130577190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wattmeter Cards Analysis of Oil-Producing Pumps Electric Drives","authors":"A. Yashin, M. Khakimyanov","doi":"10.1109/UralCon52005.2021.9559572","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559572","url":null,"abstract":"A significant part of oil production wells is operated by sucker rod pump units. Low-speed asynchronous electric motors with increased starting torque are used as drives for well sucker rod pumps. Balancing sucker rod pumping units allows for smoother loading and reduced power consumption. The authors investigated the balance of well pumping units. The impact of balancing on electricity consumption has been assessed. The following research methods were used: statistical analysis of wattmeter cards; mathematical methods for analyzing wattmeter cards with determining the average value of power consumption, the coefficient of imbalance, and the potential for energy saving. As a result, it was found that 2% of well pumping units are balanced. At the same time, 35% of well pumping units have an unbalance coefficient worse than 0.5. The negative effect of insufficient balancing of sucker rod pump units on electricity consumption is shown. As a result of balancing, the energy consumption of well pump drives can be reduced by 5-20% while maintaining production volumes.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114999109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of a Fault Location Method on an Overhead Power Line with a Branch","authors":"G. Filatova, A. Petrov","doi":"10.1109/UralCon52005.2021.9559608","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559608","url":null,"abstract":"Overhead Transmission power lines (OTL) are the most extended and least reliable elements of the electric power system (EPS). Improving the accuracy of fault location (FL) methods on power lines is an urgent task. One of the means of increasing the accuracy of FL methods is the use of digital instrument transformers.The article is devoted to the development of FL methods for power lines with two-way power supply having a branch. The work is a continuation of the development and research in the field of FL based on digital instrument transformers, carried out at the Ivanovo State Power Engineering University (ISPEU). The results of evaluating the accuracy of the method on a network model in Matlab + Simulink are presented.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115093896","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New Implementation of Common-Mode-Voltage-Eliminating Nearest-Vector-Selecting Space Vector Control for Three-Phase Multilevel Inverter","authors":"N. Lopatkin","doi":"10.1109/UralCon52005.2021.9559495","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559495","url":null,"abstract":"A simpler implementation of the space vector control technique, which is selecting the vectors nearest to the reference, and whereby providing elimination of the common-mode voltage of three-phase multilevel voltage source inverters (MLVSI) is proposed. The considered algorithm applies the particular MLVSI voltage space vectors, which produce the zero value of the common-mode voltage, i.e. the voltage across the load common point and the MLVSI common point. Two normalized inverter phase voltages values (star load voltages) have been projected to the new oblique-angled 60-degree axes. These values are treated not only as the oblique-angled coordinates, but also as barycentric coordinates on triangles of three nearest zero-common-mode-voltage vectors. The offered approach helps to get rid of the drawback of the conventional implementation of the space vector control with elimination of the common-mode voltage. In particular, no multiple applying per sampling period the square function and the square root function, related to distances calculations, are needed.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"126 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124441402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"On the Occurrence of Subsynchronous Torsional Oscillations of Gas Turbine Units in an Isolated Energy Area with an Industrial Load","authors":"P. Ilyushin, A. Kulikov","doi":"10.1109/UralCon52005.2021.9559591","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559591","url":null,"abstract":"The causes of the occurrence and development of random non-cyclic vibroactivity of gas turbine units (GTUs) in an isolated energy area with an industrial load have been analyzed. It has been found that torsional vibrations of the rotating GTU parts first occur, causing radial oscillation at frequencies close to the first natural frequency of rotating masses (11.8 Hz). This further leads to the manifestation of resonance phenomena in certain modes, a sharp increase in the GTU gear oscillation level, and the shutdown of all operating GTUs with the complete blackout of the energy area. The main cause of the occurrence of subsynchronous torsional oscillations of the GTUs is the load shedding by large asynchronous motors connected through thyristor variable frequency drives (VFDs). Load shedding leads to the VFD input current amplitude fluctuations, which, in turn, cause oscillations of the GTU load current and shaft torque. Field tests have shown that the modulation of the amplitude of the fundamental harmonic of the non-sinusoidal waveform during load shedding may reach 40 % of the rated value. The lists of top-priority and long-term organizational and technical measures are given, the implementation of which will prevent the occurrence of subsynchronous torsional oscillations of the GTUs and contribute to the reliable power supply to the energy area consumers.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125372604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Automated System for Physical Fields Measurements Based on a Quasi-distributed Resistive Sensor","authors":"I. Shafigullin, E. Denisov, Y. Evdokimov","doi":"10.1109/UralCon52005.2021.9559462","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559462","url":null,"abstract":"This paper presents a design of the automated system for measuring physical fields based on a quasi-distributed resistive sensor with a tree-like structure. Software for control of an automated measuring system in manual and automatic modes is developed. The sensor is built using the original tree-like structure, which separates the paths of the probing and measuring currents. The prototype of the system based on microcontroller STM32F411, 14-bit current DAC, and 16-bit ADC is developed and tested. The experimental study shows possibility to achieve measurement errors lower than 0.3%. The higher accuracy can be reached with equipment that is more precise. The proposed measuring system can be adapted to measure various physical fields by means of the appropriate resistive sensors.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130024181","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Magnetizing Power at One-Sided Saturation of Power Transformers with Armored Magnetic System","authors":"A. Bychkov, Oleg Fedyai, R. Pudovinnikov","doi":"10.1109/UralCon52005.2021.9559599","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559599","url":null,"abstract":"It is shown that under space weather disturbances, quasi-direct currents in grounded high voltage windings affect the magnetization characteristics of a power transformer with an armored magnetic system. The intensity of the effect of quasi-direct currents on a power transformer depends on the state of its magnetic system, which is proposed to be distinguished by the value of the phase saturation angle as \"weak saturation\", \"moderate saturation\", \"strong saturation\". With an increase in quasi-direct currents, there is a multiple decrease in the equivalent inductive resistance of the magnetization branch and a multiple increase in the total magnetization power. The total magnetizing power is formed from two components. The first is the reactive magnetizing power, it is due to the fundamental harmonic of the magnetizing current, and the second is the distortion power, it is due to the higher harmonics of the magnetizing current. It is shown that the distortion power reaches its maximum value at the phase angle 90 deg. The obtained calculated expressions make it possible to determine the components of the total magnetization power in the entire range of changes in the magnetization reversal mode of a power transformer under the influence of quasi-direct currents up to a complete transition to the region of technical saturation.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127972910","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Multi-Agent Approach to SOFC-Based Generation System Control","authors":"E. Sosnina, A. Shalukho, L. Veselov","doi":"10.1109/UralCon52005.2021.9559521","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559521","url":null,"abstract":"The problem of the optimal control for a SOFT-based generation system is being solved with a multi-agent approach which allows to take into account the environmental friendliness and low maneuverability of solid oxide fuel cells (SOFCs). For the SOFT-based generation system, a SOFC-agent and a load-agent have been created. Algorithms for the agent operation have been developed. To study the multi-agent control system effectiveness, the JADE platform and the RastrWin software package have been used. In the JADE simulation environment, an interaction model of the SOFT-based generation system agents with other agents within distributed energy system (DES) has been developed and investigated. Using the RastrWin platform, a simulation model of the DES electrical network has been implemented and the indicators of steady-state operating modes of the SOFT-based generation system have been investigated. The research results have shown the positive effects achieved when using a multi-agent control system (complete use of the SOFC generated electricity, ensuring the required voltage level on the buses of consumers with a SOFC power plant).","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126424071","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Fedorov, V. S. Petrov, V. Naumov, Dmitriy Arkadiev
{"title":"Traveling Wave Fault Location Reliability Improving","authors":"A. Fedorov, V. S. Petrov, V. Naumov, Dmitriy Arkadiev","doi":"10.1109/UralCon52005.2021.9559617","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559617","url":null,"abstract":"For single-end or double-end traveling wave (TW) fault location it is required to identify the TW front that arrived the first to the installation place of the locator from a short circuit (SC) along the protected power line (used TW front). If the protected power line has a parallel short power line, the TWs fronts along them from the SC reach the measurement place earlier than the used TW front. This dramatically complicates the identification of the used TW front and can lead to significant error in fault location. Traditional methods of identifying the used TW front have low reliability due to the impossibility of accurately measuring the voltage TWs fronts using capacitive and inductive voltage transformers. In this article methods of identifying the used TW front are proposed. Proposed methods only use current TWs measured with high accuracy from electromagnetic current transformers. The proposed methods are developed to improving the reliability of the TW fault location.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128525409","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}