Journal of the International Society for Respiratory Protection最新文献

筛选
英文 中文
Next-Generation Custom-Fit Reusable Respiratory Protective Device with Continuous Fit Monitoring - Part II: Continuous Fit Monitoring. 下一代可持续密合度监测定制型可重复使用呼吸防护设备--第二部分:持续密合度监测。
Sungmee Park, Yuanqing Tian, Michael Bergman, Jonisha Pollard, Ziqing Zhuang, Sundaresan Jayaraman
{"title":"Next-Generation Custom-Fit Reusable Respiratory Protective Device with Continuous Fit Monitoring - Part II: Continuous Fit Monitoring.","authors":"Sungmee Park, Yuanqing Tian, Michael Bergman, Jonisha Pollard, Ziqing Zhuang, Sundaresan Jayaraman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Filtering facepiece respirators (FFRs) are manufactured in discrete sizes, with some models being limited in accommodating the fit of some sex and race combinations. This study presents the development of a custom-fit respiratory protective device (RPD) which conforms to a user's facial features and flexes and moves with facial movements during use. Our design also integrates a pressure-sensing network, which continuously monitors fit and will alert the user when the fit is compromised. In this Part II of the three-part series, we design and incorporate a continuous fit monitoring system in the RPD designed in Part I to enhance its role in protecting users from inhalation hazards in an effective manner during its use. The fit monitoring system comprises a fabric-based sensor network integrated into the RPD and an Android-based App designed to alert the user when the pressure at the faceseal falls below a given threshold established during the initial configuration of the RPD for the user. We also develop algorithms for the incorporation of the sensor slots and data buses into the custom-fit RPD using the Taxonomy of Landmarks defined in Part I. We enhance the structure developed in Part I to secure the sensor network during the use of the RPD. We develop algorithms for customizing a fastening hub to suit the head profiles of individuals to enable them to don the RPD quickly, easily, effectively, and in a repeatable manner. We demonstrate the successful application of the total design methodology by creating digital prototypes for three individuals with different facial profiles and make further advances to our goal of ensuring equitable respiratory protection for all including children, for whom RPDs are currently limited.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11358863/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142115726","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Review of the Effect of Continuous Use and Limited Reuse of N95 Respirators on Respirator Fit. N95口罩持续使用和有限重复使用对口罩适配性的影响
Daniel Berger, Catherine Caldwell, Monica Zukowski, James Basting, Lauren Mazur, Ravindra Gopaul
{"title":"Review of the Effect of Continuous Use and Limited Reuse of N95 Respirators on Respirator Fit.","authors":"Daniel Berger,&nbsp;Catherine Caldwell,&nbsp;Monica Zukowski,&nbsp;James Basting,&nbsp;Lauren Mazur,&nbsp;Ravindra Gopaul","doi":"","DOIUrl":"","url":null,"abstract":"<p><strong>Background: </strong>Coronavirus disease 2019 (COVID-19) has led to severe shortages of filtering facepiece respirators (FFRs). As a result, extended use, limited reuse, and FFR decontamination have been utilized to extend the life of single-use FFRs. Although some studies have raised concerns that reuse could affect the FFR's ability to form a seal, no comprehensive literature review of the effect of extended use or limited reuse on FFR seal exists.</p><p><strong>Objective: </strong>The goal of this review was to assess the effect of extended use and reuse on respirator fit, with and without decontamination.</p><p><strong>Methods: </strong>Searches of PubMed and Medrxiv yielded 24 papers that included assessment of fit after extended use or limited reuse on a human. One additional handpicked paper was added.</p><p><strong>Results: </strong>Studies report a wide variation in the number of donnings and doffings before fit failure between different models of respirators. Additionally, while seal checks lack sufficient sensitivity to reliably detect fit failures, individuals who failed fit testing were often able to pass subsequent tests by re-positioning the respirator. Even with failure, respirators often maintained a substantially higher level of fit than a surgical mask, so they may still provide a level of protection in crisis settings.</p><p><strong>Conclusion: </strong>Based on currently available data, this literature review was unable to establish a consensus regarding the amount of time a respirator can be worn or the number of uses before fit failure will occur. Furthermore, variations in reuses before fit failure between different models of N95 respirators limit the ability to offer a comprehensive recommendation of greater than one reuse or a specific amount of wear time.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191141/pdf/nihms-1832807.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9501748","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Elastomeric Half Mask Respirators: An Alternative to Disposable Respirators and a Solution to Shortages during Public Health Emergencies. 弹性半面罩呼吸器:一次性呼吸器的替代品和解决公共卫生紧急情况下呼吸器短缺问题的办法。
Lee A Greenawald, Emily J Haas, Maryann M D'Alessandro
{"title":"Elastomeric Half Mask Respirators: An Alternative to Disposable Respirators and a Solution to Shortages during Public Health Emergencies.","authors":"Lee A Greenawald, Emily J Haas, Maryann M D'Alessandro","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>During public health emergencies such as an influenza pandemic, disposable filtering facepiece respirator (FFR) shortages have a significant impact on the national response, affecting many types of workplaces that rely on respiratory protection. During the COVID-19 pandemic, severe FFR shortages led the CDC to publish strategies for optimizing the supply of N95 FFRs. These strategies included the extended use and limited reuse of FFRs, wearing decontaminated FFRs, wearing respirators that meet an international respirator standard, or wearing FFRs that were past their manufacturer-designated shelf life. An additional strategy to mitigate supply shortages that was highlighted during the COVID-19 pandemic was to wear reusable respirators, such as elastomeric half mask respirators (EHMRs), or powered air-purifying respirators, which can be cleaned, disinfected, and reused. A decade of nationwide initiatives to increase the utility of EHMRs in healthcare settings were realized during the COVID-19 pandemic as EHMRs became more well-known and were used in healthcare settings for respiratory protection. This expanded use of EHMRs led to an increase in federal procurement, research, guidance, and private sector research and development of innovative EHMR designs by manufacturers to respond to workers' needs for both respiratory protection and source control. This paper describes the role of reusable EHMRs before and during the COVID-19 pandemic, and reviews past and current research, to inform successful EHMR implementation in healthcare and first responder settings.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9924972/pdf/nihms-1774946.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9303281","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Using Public Feedback about the use of Elastomeric Half Mask Respirators to Inform a National Deployment Study within Health Settings. 利用公众对弹性半面罩呼吸器使用的反馈,为卫生机构内的国家部署研究提供信息。
Emily J Haas, Lee A Greenawald, Alexa Furek, Maryann M D'Alessandro
{"title":"Using Public Feedback about the use of Elastomeric Half Mask Respirators to Inform a National Deployment Study within Health Settings.","authors":"Emily J Haas,&nbsp;Lee A Greenawald,&nbsp;Alexa Furek,&nbsp;Maryann M D'Alessandro","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Reusable elastomeric half mask respirators (EHMRs) have been encouraged for use during conventional, contingency, and crisis capacity in healthcare delivery settings as an alternative to disposable N95 filtering facepiece respirators (FFRs). However, standard, operationalized guidelines for implementing EHMRs in healthcare and first responder settings are needed to facilitate such integration. Specifically, research is needed to identify and address specialized concerns in healthcare delivery settings beyond hospitals to understand the widespread barriers to EHMR use and how organizational culture can support or hinder EHMR adoption. The Strategic National Stockpile (SNS) requested support from the National Institute for Occupational Safety and Health (NIOSH) to develop its strategy to purchase and distribute EHMRs to interested health organizations. To support this SNS effort, NIOSH published a Federal Register Notice (FRN) to request formative input from the public on the nationwide distribution of EHMRs and provided the technical analysis of the responses. Twenty-two representatives from first responder organizations, healthcare and dental associations, manufacturers, higher education, medical/nursing societies, and a union provided comments for consideration. This feedback was qualitatively analyzed to identify themes among the comments. This paper discusses patterns that emerged in the feedback provided within the primary topics of perceived advantages and disadvantages of EHMRs and key considerations for a successful national deployment of EHMRs. This paper also discusses how the formative feedback received was critical to informing the SNS's strategy to purchase and deploy EHMRs for longitudinal demonstration projects with the goal to produce updated EHMR implementation guidelines and best practices.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10191103/pdf/nihms-1781342.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9506999","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
History of U.S. Respirator Approval (Continued) - Gas masks, Supplied-air respirators, and Chemical cartridge respirators. 美国呼吸器批准的历史(续)-防毒面具,供应空气呼吸器和化学药筒呼吸器。
David Spelce, Timothy R Rehak, Richard W Metzler, James S Johnson
{"title":"History of U.S. Respirator Approval (Continued) - Gas masks, Supplied-air respirators, and Chemical cartridge respirators.","authors":"David Spelce,&nbsp;Timothy R Rehak,&nbsp;Richard W Metzler,&nbsp;James S Johnson","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>This article is the third in a series of four articles on respirator history. This article continues to follow the history of respirator approval, use, and improvements in the US as discussed in our article entitled, <i>History of U.S. Respirator Approval</i>, published in the ISRP Journal, Vol. 35, No. 1, 2018 (Spelce. et. al.2018). In addition, a 1957 respirator decision logic diagram illustrates the U.S. Bureau of Mines (USBM) rules to follow for respirator selection (USBM 1957).</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9490806/pdf/nihms-1589588.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33488717","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Developing home-disinfection and filtration efficiency improvement methods for N95 respirators and surgical facial masks: stretching supplies and better protection during the ongoing COVID-19 Pandemic. 开发 N95 呼吸器和外科口罩的家庭消毒和过滤效率改进方法:在 COVID-19 大流行期间延长供应和提供更好的保护。
Journal of the International Society for Respiratory Protection Pub Date : 2020-01-01 Epub Date: 2020-04-20
Roland Yan, Steve Chillrud, Debra L Magadini, Beizhan Yan
{"title":"Developing home-disinfection and filtration efficiency improvement methods for N95 respirators and surgical facial masks: stretching supplies and better protection during the ongoing COVID-19 Pandemic.","authors":"Roland Yan, Steve Chillrud, Debra L Magadini, Beizhan Yan","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The U.S. CDC announced on 04/03/2020 that all citizens should wear face coverings when in public, potentially increasing demand for medical face masks from the public and exacerbating mask shortages for Covid-19 response staff. One solution is reuse after disinfection for the general public. Prior studies have shown that heating for 30 mins at 70°C or above effectively kills SARS, including SARS-CoV-2, and Influenza viruses on masks. Black carbon (BC) particles generated from a kerosene-lamp were used as a proxy for Coronavirus aerosols to test mask performance after disinfection given overlapping size distributions. We determined filtration efficiency (FE) measurements by comparing BC values on both sides of the respirators or masks (Moldex N95 and 3M N95 respirators, HSI surgical masks) placed under vacuum on mannequins. To obtain the maximum FE, each mask type was first measured while taped or modified to tightly fit a mannequin's face when new and after each heating cycle. No reduction in average FE was observed even after 10 disinfection cycles, with FE statistically greater than 95% for N95 respirators and 70% for surgical masks. In sharp contrast, the FE of all medical masks with no additional sealing decreased to ~ 40%, confirming the effectiveness of facial masks relies upon a tight fit. For solving this issue, we designed a method for making individualized custom nose clips to hold a mask tightly to face; FE of 3M N95 respirators and surgical masks remained above 95% and 80%, respectively. Surprisingly, the FE of three homemade thick cloth coverings (in normal use) were 55%. Though more work is still needed, this result supports the public announcements that the public could wear cloth coverings instead of N95 respirators or surgical masks in low-risk environments. When worn with a customized nose clip, N95 respirators and surgical masks have higher FE than the CDC design for cloth coverings.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9258976/pdf/nihms-1640056.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40593742","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Review of Decontamination Methods for Filtering Facepiece Respirators. 过滤式口罩去污方法综述。
Journal of the International Society for Respiratory Protection Pub Date : 2020-01-01 Epub Date: 2020-10-09
Mike Bergman, Edward M Fisher, Brian K Heimbuch
{"title":"A Review of Decontamination Methods for Filtering Facepiece Respirators.","authors":"Mike Bergman,&nbsp;Edward M Fisher,&nbsp;Brian K Heimbuch","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>During the current COVID-19 infectious disease pandemic, the demand for NIOSH-approved filtering facepiece respirators (FFR) has exceeded supplies and decontamination and reuse of FFRs has been implemented by various user groups. FFR decontamination and reuse is only intended to be implemented as a crisis capacity strategy. This paper provides a review of decontamination procedures in the published literature and calls attention to their benefits and limitations. In most cases, the data are limited to a few FFR models and a limited number of decontamination cycles. Institutions planning to implement a decontamination method must understand its limitations in terms of the degree of inactivation of the intended microorganisms and the treatment's effects on the fit and filtration of the device.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7707143/pdf/nihms-1640891.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38668493","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Planning for Epidemics and Pandemics: Assessing the Potential Impact of Extended Use and Reuse Strategies on Respirator Usage Rates to Support Supply-and-Demand Planning Efforts. 流行病和大流行规划:评估延长使用和重复使用策略对呼吸器使用率的潜在影响,以支持供需规划工作。
Patrick L Yorio, Edward M Fisher, F Selcen Kilinc-Balci, Dana Rottach, Joshua Harney, Melissa Seaton, Matthew M Dahm, Todd Niemeier
{"title":"Planning for Epidemics and Pandemics: Assessing the Potential Impact of Extended Use and Reuse Strategies on Respirator Usage Rates to Support Supply-and-Demand Planning Efforts.","authors":"Patrick L Yorio,&nbsp;Edward M Fisher,&nbsp;F Selcen Kilinc-Balci,&nbsp;Dana Rottach,&nbsp;Joshua Harney,&nbsp;Melissa Seaton,&nbsp;Matthew M Dahm,&nbsp;Todd Niemeier","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>During epidemics and pandemics healthcare personnel (HCP) are on the front line of disease containment and mitigation. Personal protective equipment (PPE), such as NIOSH-approved N95 filtering facepiece respirators (FFRs), serve an important role in minimizing HCP risks and are in high demand during public health emergencies. Because PPE demand can exceed supply, various public health strategies have been developed to reduce the rate of PPE consumption as supply dwindles. Extended use and limited reuse of N95 FFRs are strategies advocated by many governmental agencies used to increase the number of times a device can be used. Increased use of respirators designed for reuse-such as powered air-purifying respirators (PAPRs) and elastomeric half-mask and full facepiece air-purifying respirators- is another option designed to reduce the continuous need for new devices as the daily need for respirator use increases. Together, these strategies are designed to reduce the number of PPE units that must be discarded daily and, therefore, extend the longevity of available supply. The purpose of this paper is to theoretically estimate the impact of extended use and limited reuse strategies for N95 FFRs and the increased use of reusable respirator options on PPE consumed. The results suggest that a considerable reduction in PPE consumption would result from extended use and limited reuse of N95 FFRs and the increased use of respirators designed for reuse; however, the practical benefits must be balanced with the risks and economic costs. In addition, extended use and reuse strategies must be accompanied by proper procedures to reduce risk. The study is designed to support epidemic and pandemic PPE supply and demand planning efforts.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7274506/pdf/nihms-1593216.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38018280","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A General Framework to Test and Evaluate Filtering Facepiece Respirators Considered for Crisis Capacity Use as a Strategy to Optimize Supply. 测试和评估过滤式面罩呼吸器的总体框架,考虑将其用于危机处理能力,作为优化供应的一项战略。
Katherine N Yoon, Lee A Greenawald, Dana R Rottach, Jonisha P Pollard, Patrick L Yorio
{"title":"A General Framework to Test and Evaluate Filtering Facepiece Respirators Considered for Crisis Capacity Use as a Strategy to Optimize Supply.","authors":"Katherine N Yoon, Lee A Greenawald, Dana R Rottach, Jonisha P Pollard, Patrick L Yorio","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>During a public health emergency, respirator shortages can have a profound impact on the national response, such as for the current coronavirus disease 2019 (COVID-19) pandemic. Due to a severe shortage of respirators (particularly filtering facepiece respirators [FFRs]), there may be contexts in which understanding the performance of FFRs that are approved for use as part of a crisis capacity strategy is desired. This includes FFRs that are not covered under the National Institute for Occupational Safety and Health (NIOSH) Respirator Approval Program because they have been stored past their designated shelf life, have been decontaminated, or are approved by international certification bodies other than NIOSH. The purpose of this document is to provide a general framework to assess the performance of FFRs that are only being used as a crisis capacity strategy. The intended audience are those who are responsible for managing large amounts of FFRs. This framework includes a four-step process consisting of: 1) defining the population of FFRs to be sampled; 2) providing sampling strategy options; 3) inspecting and testing the sampled units; and 4) evaluating the results. In addition to the four-step process, we provide an example of how NIOSH recently evaluated the quality of FFRs sampled from ten U.S. stockpiles.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7274519/pdf/nihms-1592999.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38018279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Numerical Simulations of Exhaled Particles from Wearers of Powered Air Purifying Respirators. 动力空气净化呼吸器佩戴者呼出颗粒物的数值模拟。
Susan S Xu, Zhipeng Lei, Ziqing Zhuang, Michael Bergman
{"title":"Numerical Simulations of Exhaled Particles from Wearers of Powered Air Purifying Respirators.","authors":"Susan S Xu, Zhipeng Lei, Ziqing Zhuang, Michael Bergman","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>In surgical settings, infectious particulate wound contamination is a recognized cause of post-operative infections. Powered air purifying respirators (PAPRs) are worn by healthcare workers for personal protection against contaminated aerosols. Healthcare infection preventionists have expressed concern about the possibility that infectious particles expelled from PAPR exhalation channels could lead to healthcare-associated disease, especially in operative settings where sterile procedural technique is essential. This study used computational fluid dynamics (CFD) modeling to simulate and visualize the distribution of particles exhaled by PAPR wearers. Using CFD simulations, the PAPR inside to outside ratio of particle concentrations was estimated. Also, the effects of particle sizes, supplied-air flow rates, and breathing work rates on outward leakage were evaluated. This simulation study reconstructed a geometrical model of a static median headform wearing a loose-fitting PAPR by capturing a 3D image. We defined a mathematical model for the headform and PAPR system and ran simulations with four particle sizes, three breathing workloads and two supplied-air flow rates (a total 24 configurations; 4×3×2=24) applied on the digital model of the headform and PAPR system. This model accounts for exhaled particles, but not ambient particles. Computed distributions of particles inside and outside the PAPR are displayed. The outward concentration leakage was low at surgical setting, e.g., it was about 9% for a particle size of 0.1 and 1 μm at light breathing and a 205 L/min supplied-air flow rate. The supplied-air flow rates, particle sizes, and breathing workloads had effects on the outward concentration leakage, as the outward concentration leakage increased as particle size decreased, breathing workload increased, and the supplied-air flow rate decreased. The CFD simulations can help to optimize the supplied-air flow rates. When the loose-fitting PAPR is used, exhaled particles with small size (below 1μm), or heavy breathing workloads, may generate a great risk to the sterile field and should be avoided.</p>","PeriodicalId":73984,"journal":{"name":"Journal of the International Society for Respiratory Protection","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193200/pdf/nihms-1878287.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9574091","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信