Journal for the measurement of physical behaviour最新文献

筛选
英文 中文
Simulation-Based Evaluation of Methods for Handling Nonwear Time in Accelerometer Studies of Physical Activity. 基于模拟的方法评估体育活动加速度计研究中的非磨损时间处理方法。
Journal for the measurement of physical behaviour Pub Date : 2022-09-01 Epub Date: 2022-07-12 DOI: 10.1123/jmpb.2021-0030
Kristopher I Kapphahn, Jorge A Banda, K Farish Haydel, Thomas N Robinson, Manisha Desai
{"title":"Simulation-Based Evaluation of Methods for Handling Nonwear Time in Accelerometer Studies of Physical Activity.","authors":"Kristopher I Kapphahn, Jorge A Banda, K Farish Haydel, Thomas N Robinson, Manisha Desai","doi":"10.1123/jmpb.2021-0030","DOIUrl":"10.1123/jmpb.2021-0030","url":null,"abstract":"<p><p>Accelerometer data are widely used in research to provide objective measurements of physical activity. Frequently, participants may remove accelerometers during their observation period resulting in missing data referred to as nonwear periods. Common approaches for handling nonwear periods include discarding data (days with insufficient hours or individuals with insufficient valid days) from analyses and single imputation (SI) methods.</p><p><strong>Purpose: </strong>This study evaluates the performance of various discard-, SI-, and multiple imputation (MI)-based approaches on the ability to accurately and precisely characterize the relationship between a summarized measure of accelerometer counts (mean counts per minute) and an outcome (body mass index).</p><p><strong>Methods: </strong>Realistic accelerometer data were simulated under various scenarios that induced nonwear. Data were analyzed using common and MI methods for handling nonwear. Bias, relative standard error, relative mean squared error, and coverage probabilities were compared across methods.</p><p><strong>Results: </strong>MI approaches were superior to commonly applied methods, with bias that ranged from -0.001 to -0.028 that was considerably lower than that of discard-based methods (ranging from -0.050 to -0.057) and SI methods (ranging from -0.061 to -0.081). We also reported substantial variation among MI strategies, with coverage probabilities ranging from .04 to .96.</p><p><strong>Conclusion: </strong>Our findings demonstrate the benefit of applying MI methods over more commonly applied discard- and SI-based approaches. Additionally, we show that how you apply MI matters, where including data from previously observed acceleration measurements in the imputation model when using MI improves model performance.</p>","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11501082/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89770631","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Validation of Body-Worn Sensors for Gait Analysis During a 2-min Walk Test in Children. 儿童2分钟步行试验中用于步态分析的穿戴式传感器的验证。
Journal for the measurement of physical behaviour Pub Date : 2022-06-01 DOI: 10.1123/jmpb.2021-0035
Vincent Shieh, Cris Zampieri, Ashwini Sansare, John Collins, Thomas C Bulea, Minal Jain
{"title":"Validation of Body-Worn Sensors for Gait Analysis During a 2-min Walk Test in Children.","authors":"Vincent Shieh,&nbsp;Cris Zampieri,&nbsp;Ashwini Sansare,&nbsp;John Collins,&nbsp;Thomas C Bulea,&nbsp;Minal Jain","doi":"10.1123/jmpb.2021-0035","DOIUrl":"https://doi.org/10.1123/jmpb.2021-0035","url":null,"abstract":"<p><strong>Introduction: </strong>Instrumented gait mat systems have been regarded as one of the gold standard methods for measuring spatiotemporal gait parameters. However, their portable walkways confine walking to a restricted area and limit the number of gait cycles collected. Wearable inertial sensors are a potential alternative that allow more natural walking behavior and have fewer space restrictions. The objective of this pilot study was to establish the concurrent validity of body-worn sensors against the portable walkway system in older children.</p><p><strong>Methods: </strong>Twenty-one participants (10 males) 7-17 years old performed 2-min walk tests at a self-selected and fast pace in a 25-m-long hallway, while wearing three inertial sensors. Data collection were synchronized between devices and the portions of the walk when subjects passed on the walkway were used to compare gait speed, stride length, gait cycle duration, cadence, and double support time. Regression models and Bland-Altman analysis were completed to determine agreement between systems for the selected gait parameters.</p><p><strong>Results: </strong>Gait speed, cadence, gait cycle duration, and stride length as measured by inertial sensors demonstrated strong agreement overall. Double support time was found to have lower validity due to a combined bias of age, height, weight, and walking pace.</p><p><strong>Conclusion: </strong>These results support the validity of wearable inertial sensors in measuring gait speed, cadence, gait cycle duration, and stride length in children 7 years old and above during a 2-min walking test. Future studies are warranted with a broader age range to thoroughly represent the pediatric population.</p>","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398795/pdf/nihms-1915200.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9936854","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Concurrent Agreement Between ActiGraph and activPAL for Measuring Physical Activity in Pregnant Women and Office Workers. ActiGraph和activPAL在孕妇和上班族体力活动测量中的同时一致性。
Journal for the measurement of physical behaviour Pub Date : 2022-06-01 Epub Date: 2022-04-23 DOI: 10.1123/jmpb.2021-0050
Melissa A Jones, Sara J Diesel, Bethany Barone Gibbs, Kara M Whitaker
{"title":"Concurrent Agreement Between ActiGraph and activPAL for Measuring Physical Activity in Pregnant Women and Office Workers.","authors":"Melissa A Jones,&nbsp;Sara J Diesel,&nbsp;Bethany Barone Gibbs,&nbsp;Kara M Whitaker","doi":"10.1123/jmpb.2021-0050","DOIUrl":"https://doi.org/10.1123/jmpb.2021-0050","url":null,"abstract":"<p><strong>Introduction: </strong>Current best practice for objective measurement of sedentary behavior and moderate-to-vigorous intensity physical activity (MVPA) requires two separate devices. This study assessed concurrent agreement between the ActiGraph GT3X and the activPAL3 micro for measuring MVPA to determine if activPAL can accurately measure MVPA in addition to its known capacity to measure sedentary behavior.</p><p><strong>Methods: </strong>Forty participants from two studies, including pregnant women (<i>n</i> = 20) and desk workers (<i>n</i> = 20), provided objective measurement of MVPA from waist-worn ActiGraph GT3X and thigh-worn activPAL micro3. MVPA from the GT3X was compared with MVPA from the activPAL using metabolic equivalents of task (MET)- and step-based data across three epochs. Intraclass correlation coefficient and Bland-Altman analyses, overall and by study sample, compared MVPA minutes per day across methods.</p><p><strong>Results: </strong>Mean estimates of activPAL MVPA ranged from 22.7 to 35.2 (MET based) and 19.7 to 25.8 (step based) minutes per day, compared with 31.4 min/day (GT3X). MET-based MVPA had high agreement with GT3X, intraclass correlation coefficient ranging from .831 to .875. Bland-Altman analyses revealed minimal bias between 15- and 30-s MET-based MVPA and GT3X MVPA (-3.77 to 8.63 min/day, <i>p</i> > .10) but with wide limits of agreement (greater than ±27 min). Step-based MVPA had moderate to high agreement (intraclass correlation coefficient: .681-.810), but consistently underestimated GT3X MVPA (bias: 5.62-11.74 min/day, <i>p</i> < .02). For all methods, activPAL appears to better estimate GT3X at lower quantities of MVPA. Results were similar when repeated separately by pregnant women and desk workers.</p><p><strong>Conclusion: </strong>activPAL can measure MVPA in addition to sedentary behavior, providing an option for concurrent, single device monitoring. MET-based MVPA using 30-s activPAL epochs provided the best estimate of GT3X MVPA in pregnant women and desk workers.</p>","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9635580/pdf/nihms-1819674.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40451186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
COVID-19 Highlights the Potential for a More Dynamic Approach to Physical Activity Surveillance 2019冠状病毒病凸显了采取更动态的身体活动监测方法的潜力
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2022-0004
A. Rowlands, P. Saint-Maurice, P. Dall
{"title":"COVID-19 Highlights the Potential for a More Dynamic Approach to Physical Activity Surveillance","authors":"A. Rowlands, P. Saint-Maurice, P. Dall","doi":"10.1123/jmpb.2022-0004","DOIUrl":"https://doi.org/10.1123/jmpb.2022-0004","url":null,"abstract":"The emergence of severe acute respiratory syndrome corona-virus 2, has urged the scienti fi c community and industry to obtain population snapshots of lifestyle behaviors to characterize changes in behaviors during relatively short windows of time (e","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74007858","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Processing of Accelerometry Data with GGIR in Motor Activity Research Consortium for Health 运动活动研究联合会中使用GGIR处理加速度测量数据
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2022-0018
Wei Guo, A. Leroux, H. Shou, L. Cui, Sun J. Kang, M. Strippoli, M. Preisig, V. Zipunnikov, K. Merikangas
{"title":"Processing of Accelerometry Data with GGIR in Motor Activity Research Consortium for Health","authors":"Wei Guo, A. Leroux, H. Shou, L. Cui, Sun J. Kang, M. Strippoli, M. Preisig, V. Zipunnikov, K. Merikangas","doi":"10.1123/jmpb.2022-0018","DOIUrl":"https://doi.org/10.1123/jmpb.2022-0018","url":null,"abstract":"The Mobile Motor Activity Research Consortium for Health (mMARCH) is a collaborative network of clinical and community studies that employ common digital mobile protocols and collect common clinical and biological measures across participating studies. At a high level, a key scientific goal which spans mMARCH studies is to develop a better understanding of the interrelationships between physical activity (PA), sleep (SL), and circadian rhythmicity (CR) and mental and physical health in children, adolescents, and adults. mMARCH studies employ wrist-worn accelerometry to obtain objective measures of PA/SL/CR. However, there is currently no consensus on a standard data processing pipeline for raw accelerometry data and few open-source tools which facilitate their development. The R package GGIR is the most prominent open-source software package for processing raw accelerometry data, offering great functionality and substantial user flexibility. However, even with GGIR, processing done in a harmonized and reproducible fashion across multiple analytical centers requires a nontrivial amount of expertise combined with a careful implementation. In addition, there are many statistical methods useful for analyzing PA/SL/CR patterns using accelerometry data which are implemented in non-GGIR R packages, including methods from multivariate statistics, functional data analysis, distributional data analysis, and time series analyses. To address the issues of multisite harmonization and additional feature creation, mMARCH developed a streamlined harmonized and reproducible pipeline for loading and cleaning raw accelerometry data via GGIR, merging GGIR, and non-GGIR features of PA/SL/CR together, implementing several additional data and feature quality checks, and performing multiple analyses including Joint and Individual Variation Explained, an unsupervised machine learning dimension reduction technique that identifies latent factors capturing joint across and individual to each of three domains of PA/SL/CR. The pipeline is easily modified to calculate additional features of interest, and allows for studies not affiliated with mMARCH to apply a pipeline which facilitates direct comparisons of scientific results in published work by mMARCH studies. This manuscript describes the pipeline and illustrates the use of combined GGIR and non-GGIR features by applying Joint and Individual Variation Explained to the accelerometry component of CoLaus|PsyCoLaus, one of mMARCH sites. The pipeline is publicly available via open-source R package mMARCH.AC.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77526500","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Investigating the Effects of Applying Different Actigraphy Processing Approaches to Examine the Sleep Data of Patients With Neuropathic Pain 探讨应用不同的活动描记处理方法检查神经性疼痛患者睡眠数据的效果
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2022-0017
Hannah J. Coyle-Asbil, A. Bhatia, Andrew S. P. Lim, Mandeep Singh
{"title":"Investigating the Effects of Applying Different Actigraphy Processing Approaches to Examine the Sleep Data of Patients With Neuropathic Pain","authors":"Hannah J. Coyle-Asbil, A. Bhatia, Andrew S. P. Lim, Mandeep Singh","doi":"10.1123/jmpb.2022-0017","DOIUrl":"https://doi.org/10.1123/jmpb.2022-0017","url":null,"abstract":"Individuals suffering from neuropathic pain commonly report issues associated with sleep. To measure sleep in this population, researchers have used actigraphy. Historically, actigraphy data have been analyzed in the form of counts; however, due to the proprietary nature, many opt to quantify data in its raw form. Various processing techniques exist to accomplish this; however, it remains unclear how they compare to one another. This study sought to compare sleep measures derived using the GGIR R package versus the GENEActiv (GA) R Markdown tool in a neuropathic pain population. It was hypothesized that the processing techniques would yield significantly different sleep outcomes. One hundred and twelve individuals (mean age = 52.72 ± 13.01 years; 60 M) with neuropathic pain in their back and/or lower limbs were included. While simultaneously undergoing spinal cord stimulation, actigraphy devices were worn on the wrist for a minimum of 7 days (GA; 50 Hz). Upon completing the protocol, sleep outcome measures were calculated using (a) the GGIR R package and (b) the GA R Markdown tool. To compare these algorithms, paired-samples t tests and Bland–Altman plots were used to compare the total sleep time, sleep efficiency, wake after sleep onset, sleep onset time, and rise times. According to the paired-samples t test, the GA R Markdown yielded lower total sleep time and sleep efficiency and a greater wake after sleep onset, compared with the GGIR package. Furthermore, later sleep onset times and earlier rise times were reported by the GGIR package compared with the GA R Markdown.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87127070","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CRIB: A Novel Method for Device-Based Physical Behavior Analysis CRIB:一种基于设备的物理行为分析新方法
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2021-0059
P. Hibbing, S. Creasy, J. Carlson
{"title":"CRIB: A Novel Method for Device-Based Physical Behavior Analysis","authors":"P. Hibbing, S. Creasy, J. Carlson","doi":"10.1123/jmpb.2021-0059","DOIUrl":"https://doi.org/10.1123/jmpb.2021-0059","url":null,"abstract":"Physical behaviors (e.g., sleep, sedentary behavior, and physical activity) often occur in sustained bouts that are punctuated with brief interruptions. To detect and classify these interrupted bouts, researchers commonly use wearable devices and specialized algorithms. Most algorithms examine the data in chronological order, initiating and terminating bouts whenever specific criteria are met. Consequently, the bouts may encapsulate or overlap with later periods that also meet the activation and termination criteria (i.e., alternative bout solutions). In some cases, it is desirable to compare these alternative bout solutions before making a final classification. Thus, comparison-focused algorithms are needed, which can be used in isolation or in concert with their chronology-focused counterparts. In this technical note, we present a comparison-focused algorithm called CRIB (Clustered Recognition of Interrupted Bouts). It uses agglomerative hierarchical clustering to facilitate the comparison of different bout solutions, with the final classification being made in favor of the smallest number of bouts that comply with user-specified criteria (i.e., limits on the number, individual duration, and cumulative duration of interruptions). For demonstration, we use CRIB to assess bouts of moderate to vigorous physical activity in accelerometer data from the National Health and Nutrition Examination Survey, and we include a comparison against results from two established chronology-focused algorithms. Our discussion explores strengths and limitations of CRIB, as well as potential considerations and applications for using it in future studies. An online vignette (https://github.com/paulhibbing/PBpatterns/blob/main/vignettes/CRIB.pdf) is available to assist users with implementing CRIB in R.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86297302","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Use of Accelerometers in Young Children: A Methodological Scoping Review 加速计在幼儿中的使用:一项方法学范围审查
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2021-0049
Becky Breau, Hannah J. Coyle-Asbil, L. Vallis
{"title":"The Use of Accelerometers in Young Children: A Methodological Scoping Review","authors":"Becky Breau, Hannah J. Coyle-Asbil, L. Vallis","doi":"10.1123/jmpb.2021-0049","DOIUrl":"https://doi.org/10.1123/jmpb.2021-0049","url":null,"abstract":"The purpose of this scoping review was to examine publications using accelerometers in children aged 6 months to <6 years and report on current methodologies used for data collection and analyses. We examined device make and model, device placement, sampling frequency, data collection protocol, definition of nonwear time, inclusion criteria, epoch duration, and cut points. Five online databases and three gray literature databases were searched. Studies were included if they were published in English between January 2009 and March 2021. A total of 627 articles were included for descriptive analyses. Of the reviewed articles, 75% used ActiGraph devices. The most common device placement was hip or waist. More than 80% of articles did not report a sampling frequency, and 7-day protocols during only waking hours were the most frequently reported. Fifteen-second epoch durations and the cut points developed by Pate et al. in 2006 were the most common. A total of 203 articles did not report which definition of nonwear time was used; when reported, “20 minutes of consecutive zeros” was the most frequently used. Finally, the most common inclusion criteria were “greater or equal to 10 hr/day for at least 3 days” for studies conducted in free-living environments and “greater than 50% of the school day” for studies conducted in preschool or childcare environments. Results demonstrated a major lack of reporting of methods used to analyze accelerometer data from young children. A list of recommended reporting practices was developed to encourage increased reporting of key methodological details for research in this area.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91004756","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Erratum. The 7th International Conference on Ambulatory Monitoring of Physical Activity and Movement 勘误表。第七届身体活动和运动动态监测国际会议
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2022-0040
{"title":"Erratum. The 7th International Conference on Ambulatory Monitoring of Physical Activity and Movement","authors":"","doi":"10.1123/jmpb.2022-0040","DOIUrl":"https://doi.org/10.1123/jmpb.2022-0040","url":null,"abstract":"In the article title and the first paragraph of the conference abstracts, the conference was incorrectly referred to as the 8th International Conference on AmbulatoryMonitoring of Physical Activity. This has been to corrected to the 7th International Conference on Ambulatory Monitoring of Physical Activity and Movement. The article was corrected October 20, 2022. The authors apologize for the error.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81013054","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of activPAL and Actiwatch for Estimations of Time in Bed in Free-Living Adults activPAL和Actiwatch在自由生活成人床上时间估计中的比较
Journal for the measurement of physical behaviour Pub Date : 2022-01-01 DOI: 10.1123/jmpb.2021-0047
Mary C. Hidde, K. Lyden, J. Broussard, Kim Henry, Julia Sharp, Elizabeth A Thomas, C. Rynders, H. Leach
{"title":"Comparison of activPAL and Actiwatch for Estimations of Time in Bed in Free-Living Adults","authors":"Mary C. Hidde, K. Lyden, J. Broussard, Kim Henry, Julia Sharp, Elizabeth A Thomas, C. Rynders, H. Leach","doi":"10.1123/jmpb.2021-0047","DOIUrl":"https://doi.org/10.1123/jmpb.2021-0047","url":null,"abstract":"Introduction: Patterns of physical activity (PA) and time in bed (TIB) across the 24-hr cycle have important implications for many health outcomes; therefore, wearable accelerometers are often implemented in behavioral research to measure free-living PA and TIB. Two accelerometers, the activPAL and Actiwatch, are common accelerometers for measuring PA (activPAL) and TIB (Actiwatch), respectively. Both accelerometers have the capacity to measure TIB, but the degree to which these accelerometers agree is not clear. Therefore, this study compared estimates of TIB between activPAL and the Actiwatch accelerometers. Methods: Participants (mean ± SDage = 39.8 ± 7.6 years) with overweight or obesity (N = 83) wore an activPAL and Actiwatch continuously for 7 days, 24 hr per day. TIB was assessed using manufacturer-specific algorithms. Repeated-measures mixed-effect models and Bland–Altman plots were used to compare the activPAL and Actiwatch TIB estimates. Results: Statistical differences between TIB assessed by activPAL versus Actiwatch (p < .001) were observed. There was not a significant interaction between accelerometer and day of wear (p = .87). The difference in TIB between accelerometers ranged from −72.9 ± 15.7 min (Day 7) to −98.6 ± 14.5 min (Day 3), with the Actiwatch consistently estimating longer TIB compared with the activPAL. Conclusion: Data generated by the activPAL and Actiwatch accelerometers resulted in divergent estimates of TIB. Future studies should continue to explore the validity of activity monitoring accelerometers for estimating TIB.","PeriodicalId":73572,"journal":{"name":"Journal for the measurement of physical behaviour","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77647077","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信