... International Symposium on Medical Robotics. International Symposium on Medical Robotics最新文献

筛选
英文 中文
Active Motion Cancellation for Robotic Optical Coherence Tomography of Moving Eyes: A Nystagmus Phantom Study. 运动眼的机器人光学相干断层扫描主动运动抵消:眼球震颤幻影研究。
... International Symposium on Medical Robotics. International Symposium on Medical Robotics Pub Date : 2024-06-01 Epub Date: 2024-07-12 DOI: 10.1109/ismr63436.2024.10585590
Haochi Pan, Chae Woo Lim, Katelyn King, Renxiang Guan, Mark Draelos
{"title":"Active Motion Cancellation for Robotic Optical Coherence Tomography of Moving Eyes: A Nystagmus Phantom Study.","authors":"Haochi Pan, Chae Woo Lim, Katelyn King, Renxiang Guan, Mark Draelos","doi":"10.1109/ismr63436.2024.10585590","DOIUrl":"10.1109/ismr63436.2024.10585590","url":null,"abstract":"<p><p>Optical coherence tomography (OCT) is a preferred imaging technology in ophthalmology for diagnosis and management of eye disease. Standard-of-care clinical OCT systems require patients to sit upright, brace their head against the instrument, and fix their gaze into its sensing aperture. These limitations exclude those with involuntary head and eye movements, such as those present in Parkinson's disease and nystagmus, respectively, from undergoing OCT imaging. To overcome these restrictions, we combine our robotic OCT paradigm, which allows flexible patient positioning during imaging, with active cancellation of periodic motion to reduce image artifact during acquisition. We accomplish this by measuring eye motion with on-board pupil cameras, fitting the movement profile in real-time, and augmenting OCT scan waveforms using the predicted eye position. We evaluate this predictive imaging scheme with eye phantoms to precisely simulate motions typical of head and eye movement disorders and compare it to real-time scan aiming. Using registration shift in captured OCT images to quantify residual motion artifact, we demonstrate motion reduction by up to 98.5 % for typical nystagmus frequencies and an average 3.4 × reduction in residual motion compared to scan aiming alone. This approach may provide access to accurate OCT imaging for those with involuntary eye and head movement.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"2024 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12040409/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"144035604","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Artificial intelligence (AI) for minimally invasive robotics 用于微创机器人的人工智能(AI)
B. Maris
{"title":"Artificial intelligence (AI) for minimally invasive robotics","authors":"B. Maris","doi":"10.54844/mr.2022.0386","DOIUrl":"https://doi.org/10.54844/mr.2022.0386","url":null,"abstract":"","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"212 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"76604479","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Brain-Mimicking Phantom for Photoablation and Visualization. 用于光消融和可视化的脑模拟幻影。
Ravi Prakash, Kent K Yamamoto, Siobhan R Oca, Weston Ross, Patrick J Codd
{"title":"Brain-Mimicking Phantom for Photoablation and Visualization.","authors":"Ravi Prakash,&nbsp;Kent K Yamamoto,&nbsp;Siobhan R Oca,&nbsp;Weston Ross,&nbsp;Patrick J Codd","doi":"10.1109/ismr57123.2023.10130243","DOIUrl":"https://doi.org/10.1109/ismr57123.2023.10130243","url":null,"abstract":"<p><p>While the use of tissue-mimicking (TM) phantoms has been ubiquitous in surgical robotics, the translation of technology from laboratory experiments to equivalent intraoperative tissue conditions has been a challenge. The increasing use of lasers for surgical tumor resection has introduced the need to develop a modular, low-cost, functionally relevant TM phantom to model the complex laser-tissue interaction. In this paper, a TM phantom with mechanically and thermally similar properties as human brain tissue suited for photoablation studies and subsequent visualization is developed. The proposed study demonstrates the tuned phantom response to laser ablation for fixed laser power, time, and angle. Additionally, the ablated crater profile is visualized using optical coherence tomography (OCT), enabling high-resolution surface profile generation.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"2023 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10237535/pdf/nihms-1896990.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9955595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optical Fiber -Based Needle Shape Sensing: Three-channel Single Core vs. Multicore Approaches. 基于光纤的针形传感:三通道单核与多核方法。
Alexandra Cheng, Dimitri A Lezcano, Jin Seob Kim, Iulian I Iordachita
{"title":"Optical Fiber -Based Needle Shape Sensing: Three-channel Single Core vs. Multicore Approaches.","authors":"Alexandra Cheng,&nbsp;Dimitri A Lezcano,&nbsp;Jin Seob Kim,&nbsp;Iulian I Iordachita","doi":"10.1109/ismr57123.2023.10130249","DOIUrl":"https://doi.org/10.1109/ismr57123.2023.10130249","url":null,"abstract":"<p><p>Bevel-tip needles are commonly utilized in percutaneous medical interventions where a curved insertion trajectory is required. To avoid deviation from the intended trajectory, needle shape sensing and tip localization is crucial in providing the operator with feedback. There is an abundance of previous work that investigate the medical application of fiber Bragg grating (FBG) sensors, but most works select only one specific type of fiber among the many available sensor options to integrate into their hardware designs. In this work, we compare two different types of FBG sensors under identical conditions and application, namely, acting as the sensor for needle insertion shape reconstruction. We built a three-channel single core needle and a seven-channel multicore fiber (MCF) needle and discuss the pros and cons of both constructions for shape sensing experiments into constant curvature jigs. The overall needle tip error is 1.23 mm for the single core needle and 2.08 mm for the multicore needle.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"2023 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10249955/pdf/nihms-1899085.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9672569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Delta Robot Kinematic Calibration for Precise Robot-Assisted Retinal Surgery. 精确机器人辅助视网膜手术的Delta机器人运动学标定。
... International Symposium on Medical Robotics. International Symposium on Medical Robotics Pub Date : 2022-04-01 Epub Date: 2022-06-28 DOI: 10.1109/ismr48347.2022.9807517
Boyang Xiao, Alireza Alamdar, Kefan Song, Ali Ebrahimi, Peter Gehlbach, Russell H Taylor, Iulian Iordachita
{"title":"Delta Robot Kinematic Calibration for Precise Robot-Assisted Retinal Surgery.","authors":"Boyang Xiao,&nbsp;Alireza Alamdar,&nbsp;Kefan Song,&nbsp;Ali Ebrahimi,&nbsp;Peter Gehlbach,&nbsp;Russell H Taylor,&nbsp;Iulian Iordachita","doi":"10.1109/ismr48347.2022.9807517","DOIUrl":"https://doi.org/10.1109/ismr48347.2022.9807517","url":null,"abstract":"<p><p>High precision is required for ophthalmic robotic systems. This paper presents the kinematic calibration for the delta robot which is part of the next generation of Steady-Hand Eye Robot (SHER). A linear error model is derived based on geometric error parameters. Two experiments with different ranges of workspace are conducted with laser sensors measuring displacement. The error parameters are identified and applied in the kinematics to compensate for modeling error. To achieve better accuracy, Bernstein polynomials are adopted to fit the error residuals after compensation. After the kinematic calibration process, the error residuals of the delta robot are reduced to satisfy the clinical requirements.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9484559/pdf/nihms-1836536.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40374866","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Optimization-based Concurrent Control of a High Dexterity Robot for Vitreoretinal Surgery. 基于优化的高灵巧玻璃体视网膜手术机器人并行控制。
... International Symposium on Medical Robotics. International Symposium on Medical Robotics Pub Date : 2022-04-01 Epub Date: 2022-06-28 DOI: 10.1109/ismr48347.2022.9807485
Kaiyu Shi, Yishun Zhou, Ali Ebrahimi, Gang Li, Iulian Iordachita
{"title":"Optimization-based Concurrent Control of a High Dexterity Robot for Vitreoretinal Surgery.","authors":"Kaiyu Shi,&nbsp;Yishun Zhou,&nbsp;Ali Ebrahimi,&nbsp;Gang Li,&nbsp;Iulian Iordachita","doi":"10.1109/ismr48347.2022.9807485","DOIUrl":"https://doi.org/10.1109/ismr48347.2022.9807485","url":null,"abstract":"<p><p>Vitreoretinal surgery requires dexterity and force sensitivity from the clinician. A system to cooperatively control an integrated surgical robot for high dexterity manipulation within the eye's vitreous space was developed and validated in simulation. The system is composed of a 2 degrees of freedom (DoF) snake-like continuum manipulator that is attached to the end-effector of a 5-DoF rigid robot arm. It is capable of receiving position and orientation commands from a 5-DoF input device in real-time, as well as following pre-planned trajectories. The manipulator is moved to each target pose in real-time, using an optimization method to calculate the inverse kinematics solution. Constraints on the position and orientation ensure the target pose does not harm the patient within the vitreous space, enabling the robot to safely assist the clinician with vitreoretinal surgery when operating in real-time. The simulation demonstrates the system's feasibility and benefits over the existing non-dexterous system.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9540340/pdf/nihms-1836538.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"33497182","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Modeling and Operator Control of a Robotic Tool for Bidirectional Manipulation in Targeted Prostate Biopsy. 用于前列腺活检双向操作的机器人工具的建模和操作员控制。
Blayton Padasdao, Zolboo Batsaikhan, Samuel Lafreniere, Mahsa Rabiei, Bardia Konh
{"title":"Modeling and Operator Control of a Robotic Tool for Bidirectional Manipulation in Targeted Prostate Biopsy.","authors":"Blayton Padasdao,&nbsp;Zolboo Batsaikhan,&nbsp;Samuel Lafreniere,&nbsp;Mahsa Rabiei,&nbsp;Bardia Konh","doi":"10.1109/ismr48347.2022.9807514","DOIUrl":"https://doi.org/10.1109/ismr48347.2022.9807514","url":null,"abstract":"<p><p>This work introduces design, manipulation, and operator control of a bidirectional robotic tool for minimally invasive targeted prostate biopsy. The robotic tool is purposed to be used as a compliant flexure section of active biopsy needles. The design of the robotic tool comprises of a flexure section fabricated on a nitinol tube that enables bidirectional bending via actuation of two internal tendons. The statics of the flexure section is presented and validated with experimental data. Finally, the capability of the robotic tool to reach targeted positions inside prostate gland is evaluated.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"2022 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9836363/pdf/nihms-1862603.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10538890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Steering a Tendon-Driven Needle in High-Dose-Rate Prostate Brachytherapy for Patients with Pubic Arch Interference. 在耻骨弓干扰患者的高剂量前列腺近距离治疗中使用肌腱驱动针。
Bardia Konh, Blayton Padasdao, Zolboo Batsaikhan, John Lederer
{"title":"Steering a Tendon-Driven Needle in High-Dose-Rate Prostate Brachytherapy for Patients with Pubic Arch Interference.","authors":"Bardia Konh,&nbsp;Blayton Padasdao,&nbsp;Zolboo Batsaikhan,&nbsp;John Lederer","doi":"10.1109/ismr48346.2021.9661565","DOIUrl":"https://doi.org/10.1109/ismr48346.2021.9661565","url":null,"abstract":"<p><p>High-dose-rate brachytherapy (HDR BT) is a radiation therapy that places radioactive sources at cancerous tissue using needles. HDR BT offers better dose conformality and sparing of clinical structures, lower operator dependency, and fewer acute irritative symptoms compared to the other form of BT (low-dose-rate (LDR)). However, use of HDR BT is limited for patients with pubic arch interference, where the transperineal path to the prostate is blocked. This study aims to introduce a tendon-driven needle that can bend inside tissue to reach desired positions inside prostate. Initial experiments in a phantom tissue showed the feasibility of the needle to get around the pubic arch for placement at hard-to-reach target positions.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":"2021 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9838807/pdf/nihms-1862604.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10532459","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
NeuroPlan: A Surgical Planning Toolkit for an MRI-Compatible Stereotactic Neurosurgery Robot. NeuroPlan: mri兼容立体定向神经外科机器人的手术计划工具包。
... International Symposium on Medical Robotics. International Symposium on Medical Robotics Pub Date : 2021-11-01 Epub Date: 2022-01-03 DOI: 10.1109/ismr48346.2021.9661581
Farid Tavakkolmoghaddam, Dhruv Kool Rajamani, Benjamin Szewczyk, Zhanyue Zhao, Katie Gandomi, Shreyas Chandra Sekhar, Julie Pilitsis, Christopher Nycz, Gregory Fischer
{"title":"NeuroPlan: A Surgical Planning Toolkit for an MRI-Compatible Stereotactic Neurosurgery Robot.","authors":"Farid Tavakkolmoghaddam,&nbsp;Dhruv Kool Rajamani,&nbsp;Benjamin Szewczyk,&nbsp;Zhanyue Zhao,&nbsp;Katie Gandomi,&nbsp;Shreyas Chandra Sekhar,&nbsp;Julie Pilitsis,&nbsp;Christopher Nycz,&nbsp;Gregory Fischer","doi":"10.1109/ismr48346.2021.9661581","DOIUrl":"https://doi.org/10.1109/ismr48346.2021.9661581","url":null,"abstract":"<p><p>The adoption of robotic image-guided surgeries has enabled physicians to perform therapeutic and diagnostic procedures with less invasiveness and higher accuracy. One example is the MRI-guided stereotactic robotic-assisted surgery for conformal brain tumor ablation, where the robot is used to position and orient a thin probe to target a desired region within the brain. Requirements such as the remote center of motion and precise manipulation, impose the use of complex kinematic structures, which result in non-trivial workspaces in these robots. The lack of workspace visualization poses a challenge in selecting valid entry and target points during the surgical planning and navigation stage. In this paper, we present a surgical planning toolkit called the \"NeuroPlan\" for our MRI-compatible stereotactic neurosurgery robot developed as a module for 3D Slicer software. This toolkit streamlines the current surgical workflow by rendering and overlaying the robot's reachable workspace on the MRI image. It also assists with identifying the optimal entry point by segmenting the cranial burr hole volume and locating its center. We demonstrate the accuracy of the workspace rendering and burr hole parameter detection through both phantom and MR-images acquired from previously conducted animal studies.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9248070/pdf/nihms-1819242.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"40471907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Towards a Clinically Optimized Tilt Mechanism for Bilateral Micromanipulation with Steady-Hand Eye Robot. 一种临床优化的手眼机器人双侧显微操作倾斜机制。
Robert Roth, Jiahao Wu, Alireza Alamdar, Russell H Taylor, Peter Gehlbach, Iulian Iordachita
{"title":"Towards a Clinically Optimized Tilt Mechanism for Bilateral Micromanipulation with Steady-Hand Eye Robot.","authors":"Robert Roth,&nbsp;Jiahao Wu,&nbsp;Alireza Alamdar,&nbsp;Russell H Taylor,&nbsp;Peter Gehlbach,&nbsp;Iulian Iordachita","doi":"10.1109/ismr48346.2021.9661579","DOIUrl":"https://doi.org/10.1109/ismr48346.2021.9661579","url":null,"abstract":"<p><p>Cooperative robotic systems for vitreoretinal surgery can enable novel surgical approaches by allowing the surgeon to perform procedures with enhanced stabilization and high accuracy tool movements. This paper presents the optimization and design of a four-bar linkage type tilt mechanism for a novel Steady-Hand Eye Robot (SHER) which can be used equivalently on both, the left and right patient side, during a bilateral approach with two robots. In this optimization, it is desirable to limit the workspace needed for compensation motions that ensure a virtual remote center of motion (V-RCM). The safety space around the patient, the space for the surgeon's hand and maintaining positional accuracy are also included in the optimization. The applicability of the resulting optimized mechanism was confirmed with a design prototype in a representative mock-up of the surgical setting allowing multiple directions of robot approach towards a medical phantom.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8822603/pdf/nihms-1775532.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39905592","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书