2019 IEEE International Ultrasonics Symposium (IUS)最新文献

筛选
英文 中文
Carotid artery non invasive elastography (NIVE) to detect early changes of cardiovascular diseases in overweight and obese children 颈动脉无创弹性成像(NIVE)检测超重和肥胖儿童心血管疾病的早期变化
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8925819
R. Jalbout, G. Cloutier, Marie-Hélène Roy-Cardinal, M. Henderson, E. Levy, C. Lapierre, G. Soulez, J. Dubois
{"title":"Carotid artery non invasive elastography (NIVE) to detect early changes of cardiovascular diseases in overweight and obese children","authors":"R. Jalbout, G. Cloutier, Marie-Hélène Roy-Cardinal, M. Henderson, E. Levy, C. Lapierre, G. Soulez, J. Dubois","doi":"10.1109/ULTSYM.2019.8925819","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8925819","url":null,"abstract":"Increased arterial stiffness is one of the first signs of atherosclerosis. The objective of this study was to use non-invasive elastography (NIVE) to detect early changes in vascular biomechanics associated with obesity in children. The NIVE algorithm also measured the intimamedia thickness (IMT) for comparison.NIVE was applied in 120 children, 60 with elevated body mass index (BMI) (≥ 85th percentile for age and sex) and 60 non-overweight (BMI < 85th percentile). Participants were randomly selected from a longitudinal cohort, evaluating consequences of obesity in healthy children with one obese parent. The carotid wall was automatically segmented and elastograms were computed to measure the cumulated axial strain (CAS), cumulated axial translation (CAT), and maximal shear strain (Max |SSE|); IMT was also computed from segmented contours. Elastogram features were compared between groups with multivariate analyses to control for age, sex, Tanner stage, blood pressure, and lowdensity lipoprotein cholesterol (LDL).After Bonferroni correction, CAT was significantly higher in the elevated BMI group (0.68 ± 0.24 mm vs. 0.52 ± 0.18 mm), p < 0.001. CAS/CAT was significantly lower in the elevated BMI group (9.54 ± 4.8 %/mm vs. 13.34 ± 6.46 %/mm), p = 0.001; the lower CAS/CAT ratio suggests stiffer arteries with less deformation for a similar translation.Before Bonferroni correction, IMT was significantly higher in the elevated BMI group (0.36 ± 0.05 mm vs. 0.32 ± 0.05 mm), p = 0.013. IMT statistical difference was no longer significant after Bonferroni correction.After Bonferroni correction, NIVE detected differences in CAT and CAS/CAT biomarkers in elevated BMI children, whereas IMT failed to show a difference. NIVE is a promising technique to monitor radiological biomarkers of subclinical atherosclerosis in the pediatric population.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"23 1","pages":"2214-2216"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85368652","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
4D Cardiac Activation Wave Mapping in In Vivo Swine Model using Acoustoelectric Imaging 利用声电成像技术在猪体内模型中绘制四维心脏激活波
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8926147
Alexander Alvarez, Cameron Wilhite, Chet Preston, Teodoro Trujillo, Alice McArthur, D. Mustacich, R. Witte
{"title":"4D Cardiac Activation Wave Mapping in In Vivo Swine Model using Acoustoelectric Imaging","authors":"Alexander Alvarez, Cameron Wilhite, Chet Preston, Teodoro Trujillo, Alice McArthur, D. Mustacich, R. Witte","doi":"10.1109/ULTSYM.2019.8926147","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8926147","url":null,"abstract":"Though atrial fibrillation (AF) is a growing public health problem, electrical characterization of the disease with electrocardiography (ECG) is inadequate due to poor spatial resolution. The goal of this study was to investigate propagation of the cardiac activation wave in a healthy swine model using acoustoelectric cardiac imaging (ACI), a noninvasive mapping technology that combines ultrasound with electrical recording to overcome limitations with standard ECG. Real-time 4D ACI with a custom 2D 0.6 MHz matrix US array demonstrated conduction velocities of 2.21 m/s, validated with standard epicardial recording. ACI FWHM at a single timepoint, a measure related to the resolution of ACI in imaging the volume of activation at peak ECG signal, was 7.31 mm, 7.63 mm, and 6.23 mm in the depth, lateral, and elevational directions, respectively. SNR of ACI was 21dB at peak activation. ACI signals tracked through a 4D volume demonstrated appropriate propagation of the signal from base to apex and from endocardium to epicardium. This study demonstrated the potential for this technology to noninvasively map arrhythmias, such as AF, at high resolution.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"93 6 1","pages":"1414-1417"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83692424","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Acousto-Optic Modulation of Water in a Microfluidic Channel Using Planar Fresnel Type GHz Ultrasonic Transducer 平面菲涅耳型GHz超声换能器对微流控通道中水的声光调制
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8925614
Adarsh Ravi, M. Abdelmejeed, J. Kuo, A. Lal
{"title":"Acousto-Optic Modulation of Water in a Microfluidic Channel Using Planar Fresnel Type GHz Ultrasonic Transducer","authors":"Adarsh Ravi, M. Abdelmejeed, J. Kuo, A. Lal","doi":"10.1109/ULTSYM.2019.8925614","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8925614","url":null,"abstract":"Acousto-optic modulation at GHz frequencies is demonstrated in water in a microfluidic channel. The photoelastic effect in water is induced by a silicon based GHz bulk acoustic wave aluminum nitride transducer placed in a Fresnel lens configuration. The planar GHz ultrasonic transducer is fabricated with a CMOS compatible process with no thin-film release step enabling easier integration with CMOS and microfluidics. A UHF vibrometer which is sensitive to changes in the refractive index along the laser path is used to measure the peak surface displacement. The peak refractive index change was determined to be O(10-6), when 1.08GHz RF drive voltages between 1Vp and 5Vp were applied to the focusing transducer. Peak phase modulation of 6mrad was determined from the experimental results for 5Vp RF drive signal. The total modulator area of such a system is 0.086 mm2. This result provides a framework to implement CMOS integrated acousto-optic modulator arrays.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"44 1","pages":"1025-1028"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90759715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Novel Mathematical Model for Transit-time Ultrasonic Flow Measurement 一种新的跨时超声流量测量数学模型
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8925693
L. Kang, A. Feeney, W. Somerset, Ri-liang Su, D. Lines, S. Ramadas, S. Dixon
{"title":"A Novel Mathematical Model for Transit-time Ultrasonic Flow Measurement","authors":"L. Kang, A. Feeney, W. Somerset, Ri-liang Su, D. Lines, S. Ramadas, S. Dixon","doi":"10.1109/ULTSYM.2019.8925693","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8925693","url":null,"abstract":"The calculation of the averaged flow velocity along an ultrasonic path is the core step in ultrasonic transit-time flow measurement. The conventional model for calculating the path-averaged velocity does not consider the influence of the flow velocity on the propagation direction of the ultrasonic wave and can introduce error when the sound speed is not much greater than the flow velocity. To solve this problem, a new mathematical model covering the influence of the flow velocity is proposed. It has been found that the same mathematical expressions of the path-averaged flow velocity, as a function of the absolute time-of-flight (ToFs) of ultrasonic waves travelling upstream and downstream, can be derived based on either of the models. However, the expressions as a function of the time difference (the relative ToF) between the ultrasonic waves travelling upstream and downstream derived by the two models are completely different. Flow tests are conducted in a calibrated flow rig utilising air as flowing medium. Experimental results demonstrate that the path-averaged flow velocities, calculated using either the relative or the absolute ToFs based on the new model, are much more consistent and stable, whereas those calculated based on the conventional model have shown evident and increasing discrepancy when the flow velocity exceeds 15 m/s. When the flow velocity is around 39.45 m/s, the discrepancy is as high as 0.38 m/s. As the relative ToF can be more accurately, reliably and conveniently measured in real applications, the proposed mathematical model has a great potential for the increase of the accuracy of the ultrasonic transit-time flowmeters, especially for the applications such as the measurement of fluids with high flow velocities.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"78 1","pages":"1590-1593"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91070679","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
3D+t Vector Flow Imaging with Transverse Oscillations and Doppler Estimator 三维+t矢量流成像与横向振荡和多普勒估计
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8926165
F. Varray, Sébastien Salles, L. Petrusca, H. Liebgott
{"title":"3D+t Vector Flow Imaging with Transverse Oscillations and Doppler Estimator","authors":"F. Varray, Sébastien Salles, L. Petrusca, H. Liebgott","doi":"10.1109/ULTSYM.2019.8926165","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8926165","url":null,"abstract":"Blood flow evaluation with ultrasound is an extremely usefull tool in the clinics in many different situations. The evaluation of the real 2D or 3D flow direction and amplitude remains an unsolved issue and a challenge to access to the full and correct flow characteristic. In this paper, an advanced 3D ultrasound system is used to estimate the 3D blood flow in an home made phantom with a laminar flow. After the acquisitions, the 3D processing of the beamformed volumes allow the creation of transverse oscillations and motion estimation in several direction to create a complex vector flow map in 3D. The obtained streamlines are coherent through the cycle and the qualitative evaluation of the flow is possible, even in direction perpendicular to the US beam axis. The proposed setup and method must be evaluated more deeply in more complex geometries, but this work demonstrates the feasibility to use such advanced system in 3D+t flow evaluation.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"34 1","pages":"344-347"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91108433","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Non-linear-wave-based excitation of waves on a membrane 膜上波的非线性波基激发
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8925954
Jesse Heikkilä, E. Lampsijärvi, Antti Kontiola, A. Salmi, E. Hæggström
{"title":"Non-linear-wave-based excitation of waves on a membrane","authors":"Jesse Heikkilä, E. Lampsijärvi, Antti Kontiola, A. Salmi, E. Hæggström","doi":"10.1109/ULTSYM.2019.8925954","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8925954","url":null,"abstract":"Non-linear acoustic waves were used to excite propagating waves on a curved biological membrane. A non-contact method was used to measure the displacement of the membrane at the pickup point. The frequency content, time-of-flight, and amplitude of the wave travelling across the membrane at the measurement location were studied as a function of incidence angle of the shockwave for different pressures inside a vessel bounded by the membrane. Detecting the peak frequency of the pickup signal provided the most accurate estimate of the pressure inside the vessel.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"107 6 1","pages":"166-169"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89706493","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Ultrasound Transmission through a Flexible Printed Circuit Board Bonded to the Front Side of a Capacitive Micromachined Ultrasonic Transducer Array: Feasibility Study 电容式微机械超声换能器阵列前端粘接柔性印刷电路板的超声传输:可行性研究
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8926143
C. Seok, Ziad Ali, F. Y. Yamaner, Ömer Oralkan
{"title":"Ultrasound Transmission through a Flexible Printed Circuit Board Bonded to the Front Side of a Capacitive Micromachined Ultrasonic Transducer Array: Feasibility Study","authors":"C. Seok, Ziad Ali, F. Y. Yamaner, Ömer Oralkan","doi":"10.1109/ULTSYM.2019.8926143","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8926143","url":null,"abstract":"Interconnecting the inner elements of a densely populated ultrasonic transducer array with electronics poses a great challenge when pads are located in the inner area such that they are not easily accessible or wire bonding is not a viable solution. To tackle that challenge, we propose the technique of front-side flip-chip bonding capacitive micromachined ultrasonic transducer (CMUT) arrays to flexible printed circuit boards (FPCBs). As the propagation through the flex material can cause signal attenuation, we measured the pressure reduction for a reference transducer and an experimental CMUT and observed that the reference underwent a 19% pressure reduction while the experimental CMUT experienced a 33% pressure reduction after transmission through the flex. We argue that the difference can be partly attributed to inappropriate underfill in the interface between the CMUT and the FPCB. The proposed packaging approach can potentially provide a versatile interconnecting scheme for densely populated small transducers required in applications such as ultrasound neuromodulation.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"34 1","pages":"853-856"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89760850","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effects of Acoustic Nonlinearities on the Estimation of Attenuation from Ultrasonic Backscatter 声学非线性对超声后向散射衰减估计的影响
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8925571
Andres Coila, M. Oelze
{"title":"Effects of Acoustic Nonlinearities on the Estimation of Attenuation from Ultrasonic Backscatter","authors":"Andres Coila, M. Oelze","doi":"10.1109/ULTSYM.2019.8925571","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8925571","url":null,"abstract":"The attenuation coefficient (AC) has demonstrated the ability to classify tissue state. Linear acoustic propagation is assumed when estimating the AC using spectral-based methods from the ultrasonic backscatter. However, the effects of acoustic nonlinearities can distort the backscattered power spectra versus depth. The distortion of the power spectra could result in a bias in the estimation of the AC. The goal of the study was to quantify the effects of nonlinear distortion on the estimation of AC from ultrasonic backscatter using spectral methods. We computed the AC from backscattered signals using the spectral log difference method and a reference phantom to account for diffraction effects. Computational simulations and experiments in phantoms were performed. In the experiments, three tissue-mimicking phantoms, named A, B and C having estimated AC values of 0.60, 0.90, and 0.20 dB/cm/MHz, respectively, and B/A ≈ 6.6 for each phantom were scanned using a single-element focused transducer (f/2) having a 0.5\" diameter and 5-MHz center frequency. The phantoms were scanned using six excitation levels from a high-power (HP) pulsing apparatus (RAM-5000, Ritec, USA). The AC was estimated from phantom A using either phantom B (high attenuation) or phantom C (low attenuation) as the reference. The AC was estimated at each excitation level over the analysis bandwidth (− 6-dB criterion) to determine the effects of acoustic nonlinearity on estimation of AC. The presence of nonlinear distortion can be quantified through the Gol’dberg number, which is inversely proportional to the product of the nonlinearity coefficient and attenuation. We hypothesized that because the B/A values were approximately the same for each phantom, the effects of nonlinear distortion would be more pronounced when using phantom C, which had much lower attenuation. Specifically, increased excess attenuation due to transfer of energy from the fundamental to the harmonics would be observed more in phantom C. The AC estimate increased from 0.57 to 0.67 dB/cm/MHz as the excitation levels increased from level one to six when using phantom B as a reference. In contrast, when using phantom C as reference, the estimated AC slope of phantom A decreased from 0.57 to 0.43 dB/cm/MHz as the excitation levels increased from level one to six. Therefore, use of a reference with different attenuation resulted in increased bias of AC estimates due to nonlinear distortion being this deviation larger when using low attenuating media.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"15 1","pages":"2416-2419"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90527012","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Ultrasonic Wave Mixing for Nonlinear Ultrasonics in a Microfluidic Capillary 微流控毛细管中非线性超声的混合
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8926164
A. Demčenko, C. Witte, J. Reboud, J. Cooper
{"title":"Ultrasonic Wave Mixing for Nonlinear Ultrasonics in a Microfluidic Capillary","authors":"A. Demčenko, C. Witte, J. Reboud, J. Cooper","doi":"10.1109/ULTSYM.2019.8926164","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8926164","url":null,"abstract":"In this study we show that nonlinear ultrasonics, based on nonlinear wave mixing, can enable the measurement of the interactions between acoustic waves and a microliter liquid sample in a glass capillary microchannel. This has the potential to deliver new techniques with a high sensitivity to acoustic material properties.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"21 1","pages":"284-286"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73548007","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Correlation between Red Blood Cell Aggregation and Blood Glucose Level 红细胞聚集与血糖水平的相关性
2019 IEEE International Ultrasonics Symposium (IUS) Pub Date : 2019-10-01 DOI: 10.1109/ULTSYM.2019.8926267
Akiyo Fukase, Kanta Nagasawa, Shohei Mori, M. Arakawa, S. Yashiro, Yasushi Ishigaki, H. Kanai
{"title":"Correlation between Red Blood Cell Aggregation and Blood Glucose Level","authors":"Akiyo Fukase, Kanta Nagasawa, Shohei Mori, M. Arakawa, S. Yashiro, Yasushi Ishigaki, H. Kanai","doi":"10.1109/ULTSYM.2019.8926267","DOIUrl":"https://doi.org/10.1109/ULTSYM.2019.8926267","url":null,"abstract":"High blood glucose level (BGL) is related to the high viscosity of blood. Red blood cells (RBCs) tend to gather each other in the condition of high viscosity. Backscattered echoes become high as RBCs aggregate. Therefore, the intensity of backscattered echo is anticipated to be high as the BGL increases. In the present study, we investigated the relationship between RBC aggregations by ultrasound and the BGL for the development of non-invasive BGL measurement methods. Ultrasonic backscattering echoes for dorsal hand vein and BGLs were repeatedly measured from fasting to 190 min after injecting 40-g glucose for a healthy subject. The brightness of the B-mode image increased as the BGL increased. The brightnesses of B-mode image and the BGLs after 160-190 min were less than those at fasting. The relationship between the brightness of the B-mode image and BGL was almost linear, although the hysteresis characteristic was observed. This is because multiple factors other than BGL are closely related to the RBC aggregations.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"192 1","pages":"45-47"},"PeriodicalIF":0.0,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"75072637","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信