红细胞聚集与血糖水平的相关性

Akiyo Fukase, Kanta Nagasawa, Shohei Mori, M. Arakawa, S. Yashiro, Yasushi Ishigaki, H. Kanai
{"title":"红细胞聚集与血糖水平的相关性","authors":"Akiyo Fukase, Kanta Nagasawa, Shohei Mori, M. Arakawa, S. Yashiro, Yasushi Ishigaki, H. Kanai","doi":"10.1109/ULTSYM.2019.8926267","DOIUrl":null,"url":null,"abstract":"High blood glucose level (BGL) is related to the high viscosity of blood. Red blood cells (RBCs) tend to gather each other in the condition of high viscosity. Backscattered echoes become high as RBCs aggregate. Therefore, the intensity of backscattered echo is anticipated to be high as the BGL increases. In the present study, we investigated the relationship between RBC aggregations by ultrasound and the BGL for the development of non-invasive BGL measurement methods. Ultrasonic backscattering echoes for dorsal hand vein and BGLs were repeatedly measured from fasting to 190 min after injecting 40-g glucose for a healthy subject. The brightness of the B-mode image increased as the BGL increased. The brightnesses of B-mode image and the BGLs after 160-190 min were less than those at fasting. The relationship between the brightness of the B-mode image and BGL was almost linear, although the hysteresis characteristic was observed. This is because multiple factors other than BGL are closely related to the RBC aggregations.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"192 1","pages":"45-47"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Correlation between Red Blood Cell Aggregation and Blood Glucose Level\",\"authors\":\"Akiyo Fukase, Kanta Nagasawa, Shohei Mori, M. Arakawa, S. Yashiro, Yasushi Ishigaki, H. Kanai\",\"doi\":\"10.1109/ULTSYM.2019.8926267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High blood glucose level (BGL) is related to the high viscosity of blood. Red blood cells (RBCs) tend to gather each other in the condition of high viscosity. Backscattered echoes become high as RBCs aggregate. Therefore, the intensity of backscattered echo is anticipated to be high as the BGL increases. In the present study, we investigated the relationship between RBC aggregations by ultrasound and the BGL for the development of non-invasive BGL measurement methods. Ultrasonic backscattering echoes for dorsal hand vein and BGLs were repeatedly measured from fasting to 190 min after injecting 40-g glucose for a healthy subject. The brightness of the B-mode image increased as the BGL increased. The brightnesses of B-mode image and the BGLs after 160-190 min were less than those at fasting. The relationship between the brightness of the B-mode image and BGL was almost linear, although the hysteresis characteristic was observed. This is because multiple factors other than BGL are closely related to the RBC aggregations.\",\"PeriodicalId\":6759,\"journal\":{\"name\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"volume\":\"192 1\",\"pages\":\"45-47\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2019.8926267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Ultrasonics Symposium (IUS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2019.8926267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

高血糖水平(BGL)与血液的高粘度有关。在高黏度的条件下,红细胞容易相互聚集。当红细胞聚集时,后向散射回波变高。因此,预计后向散射回波强度会随着BGL的增大而增大。在本研究中,我们研究了超声RBC聚集与BGL之间的关系,以开发无创BGL测量方法。健康受试者注射40 g葡萄糖后,从禁食至190 min,反复测量手背静脉和bgl的超声后向散射回波。b模式图像的亮度随BGL的增大而增大。160 ~ 190 min后b模式图像和bgl亮度均低于禁食时。b模图像的亮度与BGL之间的关系几乎是线性的,尽管存在滞后特性。这是因为除BGL外,还有多种因素与RBC聚集密切相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation between Red Blood Cell Aggregation and Blood Glucose Level
High blood glucose level (BGL) is related to the high viscosity of blood. Red blood cells (RBCs) tend to gather each other in the condition of high viscosity. Backscattered echoes become high as RBCs aggregate. Therefore, the intensity of backscattered echo is anticipated to be high as the BGL increases. In the present study, we investigated the relationship between RBC aggregations by ultrasound and the BGL for the development of non-invasive BGL measurement methods. Ultrasonic backscattering echoes for dorsal hand vein and BGLs were repeatedly measured from fasting to 190 min after injecting 40-g glucose for a healthy subject. The brightness of the B-mode image increased as the BGL increased. The brightnesses of B-mode image and the BGLs after 160-190 min were less than those at fasting. The relationship between the brightness of the B-mode image and BGL was almost linear, although the hysteresis characteristic was observed. This is because multiple factors other than BGL are closely related to the RBC aggregations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信