Jesse Heikkilä, E. Lampsijärvi, Antti Kontiola, A. Salmi, E. Hæggström
{"title":"膜上波的非线性波基激发","authors":"Jesse Heikkilä, E. Lampsijärvi, Antti Kontiola, A. Salmi, E. Hæggström","doi":"10.1109/ULTSYM.2019.8925954","DOIUrl":null,"url":null,"abstract":"Non-linear acoustic waves were used to excite propagating waves on a curved biological membrane. A non-contact method was used to measure the displacement of the membrane at the pickup point. The frequency content, time-of-flight, and amplitude of the wave travelling across the membrane at the measurement location were studied as a function of incidence angle of the shockwave for different pressures inside a vessel bounded by the membrane. Detecting the peak frequency of the pickup signal provided the most accurate estimate of the pressure inside the vessel.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"107 6 1","pages":"166-169"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Non-linear-wave-based excitation of waves on a membrane\",\"authors\":\"Jesse Heikkilä, E. Lampsijärvi, Antti Kontiola, A. Salmi, E. Hæggström\",\"doi\":\"10.1109/ULTSYM.2019.8925954\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Non-linear acoustic waves were used to excite propagating waves on a curved biological membrane. A non-contact method was used to measure the displacement of the membrane at the pickup point. The frequency content, time-of-flight, and amplitude of the wave travelling across the membrane at the measurement location were studied as a function of incidence angle of the shockwave for different pressures inside a vessel bounded by the membrane. Detecting the peak frequency of the pickup signal provided the most accurate estimate of the pressure inside the vessel.\",\"PeriodicalId\":6759,\"journal\":{\"name\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"volume\":\"107 6 1\",\"pages\":\"166-169\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2019.8925954\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Ultrasonics Symposium (IUS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2019.8925954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Non-linear-wave-based excitation of waves on a membrane
Non-linear acoustic waves were used to excite propagating waves on a curved biological membrane. A non-contact method was used to measure the displacement of the membrane at the pickup point. The frequency content, time-of-flight, and amplitude of the wave travelling across the membrane at the measurement location were studied as a function of incidence angle of the shockwave for different pressures inside a vessel bounded by the membrane. Detecting the peak frequency of the pickup signal provided the most accurate estimate of the pressure inside the vessel.