S. Jayachandran, J. Redondo, M. Mehdi, M. A. Monclús, D. Pérez, J. Ruiz-Hervías, J. M. Molina-Aldareguia, J. LLorca
{"title":"In-Situ Measurement of the Effect of Elastic Strains on the Catalytic Activity for the Hydrogen Evolution Reaction of Au and Ag3In Thin Films","authors":"S. Jayachandran, J. Redondo, M. Mehdi, M. A. Monclús, D. Pérez, J. Ruiz-Hervías, J. M. Molina-Aldareguia, J. LLorca","doi":"10.1007/s11340-026-01271-9","DOIUrl":"10.1007/s11340-026-01271-9","url":null,"abstract":"<div><h3>Background</h3><p>the application of elastic strains is known to change the electrocatalytic activity of materials.</p><h3>Objective</h3><p>this investigation is aimed at developing a experimental strategy to determine how elastic strain affects the hydrogen evolution reaction (HER) in Au and Ag₃In thin films when used as electrocatalysts.</p><h3>Methods</h3><p>A custom-built electrochemical cell was designed and coupled to a uniaxial testing machine so that tensile strains can be applied to the flexible working electrode, enabling us to investigate in situ the effect of elastic strains on the HER activity of Au and Ag₃In thin films when used as electrocatalysts. The actual surface strains were determined by means of the shifts in the main (222) X-ray diffraction peak indicated that the externally applied strains were successfully transferred to both Au and Ag₃In thin films.</p><h3>Results</h3><p>The experimental results show that the in-plane lattice strains reached maximum values of 0.25% in Au and 1.10% in Ag₃In for a maximum applied strain of 1.70%. When the electrodes were subjected to elastic tensile strains, the HER electrocatalytic activity increased.</p><p>Conculsions: This study showcases how elastic strains can be used to modulate the HER activity of Au and Ag₃In thin films.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 7","pages":"1147 - 1159"},"PeriodicalIF":2.9,"publicationDate":"2026-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"148927678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Wang, M. Boåsen, G. Hultgren, M. Öberg, J. Faleskog
{"title":"An Inverse Finite Interval Method for Evaluating the True Stress–Strain Response from Uniaxial Tension Tests","authors":"S. Wang, M. Boåsen, G. Hultgren, M. Öberg, J. Faleskog","doi":"10.1007/s11340-026-01266-6","DOIUrl":"10.1007/s11340-026-01266-6","url":null,"abstract":"<div><h3>Background</h3><p>Analysis of finite elastic–plastic deformation requires a good constitutive description of the inelastic response. A key element is the hardening function, typically evaluated from nominal data obtained from a uniaxial tension test using the Bridgman correction method in the post-necking regime. However, the true stress–strain data obtained in this way depend crucially on the quality of the optical measurements. Based on modern and sophisticated technology, several new and demanding methods have emerged over the last decade to improve the accuracy of the Bridgman correction method.</p><h3>Objective</h3><p>To develop and validate an accurate method, combining standard experimental and numerical methods for the evaluation of the true stress–strain response of an elastic–plastic material.</p><h3>Method</h3><p>Experimental force-displacement data for a gauge section of a round bar specimen are used as input to an inverse finite interval (IFI) method to construct the true stress-strain response at discrete points by minimising the relative error between finite element simulations and experimental results.</p><h3>Results</h3><p>The inverse finite interval method is validated both numerically and experimentally. Synthetic force–displacement data are generated numerically for a set of power-law hardening materials, and the proposed method is then applied to reconstruct the true stress–strain curve. The method is proven to be robust, and reconstructed true stress–strain curves converge to the exact power-law function. Three markedly different steel grades are used for experimental validation by comparing the deformed geometry in the necking region between experimental and numerical results, showing good agreement.</p><h3>Conclusion</h3><p>The proposed inverse finite interval (IFI) method is an expedient and accurate method for evaluation of the true stress–strain curve from nominal data extracted from a uniaxial tension test.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 3","pages":"551 - 565"},"PeriodicalIF":2.4,"publicationDate":"2026-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11340-026-01266-6.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147559108","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Nanoscale Ultrasonic Vibration and High-Speed Displacement Measurement with Heterodyne Interferometry and Cost-Effective Software-Defined Radio Phase Meter","authors":"T. D. Nguyen, N. Van Muoi, H. H. Hai","doi":"10.1007/s11340-026-01279-1","DOIUrl":"10.1007/s11340-026-01279-1","url":null,"abstract":"<div><h3>Background</h3><p>High-resolution ultrasonic displacement and vibration measurements are crucial in precision machining, advanced manufacturing, and materials characterization. However, achieving both high sensitivity and high acquisition speed typically requires expensive hardware, such as high-speed analog-to-digital converters (ADCs), field-programmable gate array (FPGA) platforms, or commercial lock-in amplifiers, which constrain flexibility and cost-effectiveness.</p><h3>Objective</h3><p>This study aims to develop and validate a low-cost, high-performance phase meter for heterodyne interferometric ultrasonic-vibration measurements, using low-cost software-defined radio (SDR) hardware and open-source software.</p><h3>Methods</h3><p>A < $50 RTL-SDR-based phase meter was designed using flexible beat-frequency up and down conversion to acquire heterodyne signals spanning from kilohertz to hundreds of megahertz. Digital quadrature demodulation, multi-stage filtering, and a computationally efficient quadri-correlator algorithm were implemented in GNU Radio to achieve unwrap-free and real-time phase extraction. System performance was evaluated through simulations and ultrasonic-vibration experiments using a double-path heterodyne interferometer and was directly benchmarked against a commercial lock-in amplifier.</p><h3>Results</h3><p>Simulations showed a phase resolution of ± 0.01° and stability of ± 0.06° at 20 kHz. This corresponds to sensitivity levels in the nanometer and sub-nanometer range. Experiments confirmed that the SDR-based system can reliably measure 20 kHz ultrasonic vibrations with peak-to-peak amplitudes of less than 500 nm. Furthermore, despite the limitations of an 8-bit ADC, the SDR achieved a signal-to-noise ratio (SNR) of 130 dB for MHz-level phase-alternating signals through effective digital processing gain. This performance exceeded that of previous SDR models and showed good agreement with the commercial lock-in amplifier.</p><h3>Conclusion</h3><p>The proposed SDR-based phase meter offers a unique combination of low cost, wide heterodyne compatibility, high SNR, and nanometer-scale resolution. These characteristics demonstrate that low-cost SDR hardware, when combined with advanced digital demodulation techniques, provides a practical and high-performance alternative to conventional lock-in and FPGA-based interferometric systems for real-time ultrasonic metrology.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"691 - 712"},"PeriodicalIF":2.4,"publicationDate":"2026-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147737440","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
X. Shi, W. Li, J. Min, A. Condon, W. Li, P. M. Attia, J. Zhu
{"title":"Core Collapse Instability of Spirally Wound Jelly-Roll Lithium-Ion Batteries","authors":"X. Shi, W. Li, J. Min, A. Condon, W. Li, P. M. Attia, J. Zhu","doi":"10.1007/s11340-026-01287-1","DOIUrl":"10.1007/s11340-026-01287-1","url":null,"abstract":"<div><h3>Background</h3><p>Cylindrical lithium-ion batteries are tend to have an inward deformation during charge and discharge, which is called “core collapse”. This structural instability remains poorly quantified, and a deeper understanding of the underlying mechanics is essential for improving the structural integrity and safety of rechargeable cells.</p><h3>Objective</h3><p>This study aims to investigate the deformation and buckling mechanisms of cylindrical lithium–ion battery jelly rolls under electrochemical cycling, with a focus on the interplay between geometry, interfacial constraint, and internal stress evolution.</p><h3>Methods</h3><p>X-ray computed tomography (CT) imaging was employed to characterize the three-dimensional deformation of commercial cells, while a detailed finite element (FE) model explicitly incorporating current collectors, coating layers, and separators was developed to simulate chemo-induced stresses. The lithiation and delithiation processes were represented through an equivalent thermal-expansion surrogate to evaluate pre-buckling stress states.</p><h3>Results</h3><p>CT analysis revealed negligible volumetric and hoop strains, confirming strong geometric constraint from the spiral architecture. Simulations showed that interface compatibility between current collectors and electrodes governs hoop-dominated stress fields, and that separator wrinkling can precede electrode buckling due to low bending stiffness and expansion mismatch.</p><h3>Conclusions</h3><p>The results elucidate how hoop compression, interface constraint, and structural asymmetry collectively trigger jelly-roll instability. The findings establish a mechanistic foundation for analyzing confined expansion and guiding future multi-physics modeling of battery structural reliability.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 7","pages":"1133 - 1146"},"PeriodicalIF":2.9,"publicationDate":"2026-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11340-026-01287-1.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"148926270","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Zhao, J. Chen, X. Wang, Y. Wu, H. Yan, P. Yip, B. Li, J. Zhou, Y. Lu
{"title":"Biaxial Micro-Mechanical Device (MMD) with Meta-Structure for In-Situ Mechanical Testing","authors":"T. Zhao, J. Chen, X. Wang, Y. Wu, H. Yan, P. Yip, B. Li, J. Zhou, Y. Lu","doi":"10.1007/s11340-026-01277-3","DOIUrl":"10.1007/s11340-026-01277-3","url":null,"abstract":"<div><h3>Background</h3><p>Low-dimensional materials are crucial for next-generation electronic systems but their size-dependent mechanical properties demand precise in situ mechanical characterization. Conventional platforms such as push-to-pull (PTP) micromechanical devices are limited by high fabrication costs, poor load–displacement linearity, and restriction to uniaxial stretching.</p><h3>Objective</h3><p>This study aims to develop a novel and stable micro-mechanical device (MMD) device with excellent load–displacement linearity, utilizing cost-effective fabrication method, and to investigate the biaxial tensile behavior of low-dimensional materials.</p><h3>Methods</h3><p>We designed a MMD with a meta-structure of chiral patterns, fabricated using standard silicon wafers and wet etching, which reduces production costs and enables batch manufacturing, and did the uniaxial and biaxial tensile test.</p><h3>Results</h3><p>This design reduces stretching stress, enhancing stability, load–displacement linearity, and experimental repeatability. Uniaxial Scanning electron microscope (SEM) tensile tests confirmed no bulk rotation after 2000 nm displacement, while the gap of 3 μm was shown to be compatible with in situ tensile testing, and cyclic loading experiments validated repeatability. As a proof of concept, in situ tensile testing of ZnO nanowire revealed a strain of approximately 5%. Furthermore, a biaxial tensile MMD based on the meta-structure was demonstrated, with transverse and longitudinal displacements remaining nearly identical within 3 μm.</p><h3>Conclusion</h3><p>This MMD provides a cost-effective solution and tailorable platform for<i> in situ</i> mechanical characterization of low-dimensional materials, with the capability of biaxial stretching.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"681 - 690"},"PeriodicalIF":2.4,"publicationDate":"2026-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11340-026-01277-3.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147737437","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Ogawa, T. Hidaki, H. Tatebayashi, M. Hayashi, K. Kadoi, D. Shiozawa, T. Sakagami, E. Yukutake
{"title":"Fatigue Limit Estimation Based on Dissipated Energy for Al/Al and Al/Steel Friction Stir Welding Joints","authors":"Y. Ogawa, T. Hidaki, H. Tatebayashi, M. Hayashi, K. Kadoi, D. Shiozawa, T. Sakagami, E. Yukutake","doi":"10.1007/s11340-026-01283-5","DOIUrl":"10.1007/s11340-026-01283-5","url":null,"abstract":"<div><h3>Background</h3><p>Friction stir welding was developed as a joining technique for lightweight alloys, such as aluminum, and has been increasingly recognized for its capability to join dissimilar materials in multi-material structures. The practical application of friction stir welding requires high levels of safety and reliability.</p><h3>Objective</h3><p>This study introduces a rapid method for estimating the fatigue limit of friction stir welding using infrared thermography. It specifically focuses on energy dissipation due to localized plastic deformation and evaluates the fatigue properties of friction stir welding joints based on this dissipated energy.</p><h3>Methods</h3><p>Temperature variations by dissipated energy and their phase difference were recorded during a staircase stress level test, where stress amplitude increments occurred in short cycle steps on the specimen. In the estimation of the fatigue limit of joint, the temperature variation by dissipated energy is categorized into two groups by the domain decomposition method using the least-squares approximation.</p><h3>Results</h3><p>The joints were observed to fracture at locations where temperature variations due to dissipated energy were locally elevated. The estimated fatigue limits calculated from these temperature variations were found to closely align with the actual fatigue limits. Thus, this study demonstrates that the fatigue limit of friction stir welding joints can be effectively estimated by monitoring the increases in temperature variation caused by dissipated energy.</p><h3>Conclusions</h3><p>The fatigue limits of aluminum alloy-to-aluminum alloy and aluminum alloy-to-steel friction stir welding joints can be estimated by observing the increase in temperature variation by dissipated energy.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"665 - 679"},"PeriodicalIF":2.4,"publicationDate":"2026-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s11340-026-01283-5.pdf","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147738607","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Full-Field Out-of-Plane Displacement Measurement of Plate Structures by Monocular Parametric Homography and Finite-Element-Based Digital Image Correlation","authors":"P. Xie, Z.-R. Lu, J. Liu, L. Wang","doi":"10.1007/s11340-026-01282-6","DOIUrl":"10.1007/s11340-026-01282-6","url":null,"abstract":"<div><h3>Background</h3><p>Vision-based measurement methods are nowadays widely used in structural tests due to their non-contact nature and full-field measurement capability. Typically, out-of-plane motion measurements require two or more cameras to compensate the depth information, with the additional cameras and synchronization systems increasing the overall cost.</p><h3>Objective</h3><p>To propose an efficient monocular vision method for measuring the full-field out-of-plane displacement of plate structures.</p><h3>Methods</h3><p>The image area of interest is first discretized into finite elements, and a full-field warp function is built by interpolating the out-of-plane nodal displacements using finite element shape functions. Subsequently, the parametric homography is combined with the finite element-based warp function to relate image motion to out-of-plane displacement. The nodal displacements are then determined by matching the deformed and un-deformed image regions within the digital image correlation (DIC) framework.</p><h3>Results</h3><p>Numerical simulations confirm that the measurement error remains at a low level under appropriate element size and camera configurations. Experimental validation on the out-of-plane vibration of a steel plate further demonstrates a close agreement with the laser vibrometer results in both displacement and mode frequency/shape measurements.</p><h3>Conclusions</h3><p>The proposed monocular method enables cost-effective measurement of full-field out-of-plane displacement, demonstrating its potential as a practical tool for out-of-plane vibration analysis and modal identification of plate structures.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"647 - 664"},"PeriodicalIF":2.4,"publicationDate":"2026-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147738688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Trace G LaRue, Collin E Haese, Alison M Pouch, Jan N Fuhg, Tomasz A Timek, Manuel K Rausch
{"title":"The In-Situ Mechanics of the Tricuspid Valve: Strain Heterogeneity and Anisotropy via 3D Digital Image Correlation.","authors":"Trace G LaRue, Collin E Haese, Alison M Pouch, Jan N Fuhg, Tomasz A Timek, Manuel K Rausch","doi":"10.1007/s11340-026-01273-7","DOIUrl":"10.1007/s11340-026-01273-7","url":null,"abstract":"<p><strong>Background: </strong>The mechanics of the tricuspid valve are a critical determinant of its function and dysfunction. With millions suffering from tricuspid regurgitation, there is a pressing need to fill persistent knowledge gaps. A better understanding of the valve's mechanics is essential for improving repair strategies and biomaterial-based replacements.</p><p><strong>Objective: </strong>This study aimed to quantify the differences in strains within leaflets and between leaflets under both physiological and pathological loads.</p><p><strong>Methods: </strong>We mounted six whole porcine heart preparations in vitro and measured full-field leaflet strains using three-dimensional digital image correlation.We varied peak transvalvular pressures between 20, 50, and 80 mmHg and applied three levels of annular dilation (0%, 30%, and 60%). Strain data were transformed into leaflet-specific radial and circumferential components, and compared statistically using linear mixed-effects models.</p><p><strong>Results: </strong>Leaflet strains exhibited significant within- and between-leaflet heterogeneity. Strain magnitude increased with pressure but not with annular dilation. Additionally, strains were directionally dependent. Furthermore, we found that anterior and posterior leaflet strains near the annulus, in the belly, and near the free edge did not differ significantly. In contrast, strains in the septal leaflet increased from the annulus to the free edge.</p><p><strong>Conclusions: </strong>These data provide spatially and directionally resolved strain maps of all three tricuspid valve leaflets in whole-heart preparations. By filling a critical knowledge gap, these findings may guide the design of biomaterials for valve repair and replacement.</p>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":" ","pages":""},"PeriodicalIF":2.9,"publicationDate":"2026-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13175140/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147961791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Speckle Image Restoration for DIC Measurement Under Non-Uniform Illumination Based on Deep Learning Model","authors":"C. Zhang, X. Shao, D. Zhang","doi":"10.1007/s11340-026-01280-8","DOIUrl":"10.1007/s11340-026-01280-8","url":null,"abstract":"<div><h3>Background</h3><p>Shadows caused by non-uniform illumination can introduce significant errors in digital image correlation (DIC) measurements. The deep learning methods offer a good solution for image restoration. However, a dedicated deep learning approach for speckle images restoration in DIC measurement still requires further investigation.</p><h3>Objective</h3><p>For this purpose, based on the quality assessment criterion of speckle images, this study aims to develop an improved Generative Adversarial Network (GAN)-based model for restoration of speckle images to eliminate the interference of non-uniform illumination on DIC measurement.</p><h3>Methods</h3><p>Technically, the model consists of a generator with skip connections and multi-resolution discriminators to balance both global structures and fine details. In context of speckle images restoration, a speckle quality assessment module derived from the Gray-Level Co-occurrence Matrix (GLCM) is incorporated into the training, thereby guiding the generator to synthesize speckle patterns that more faithfully approximate real images in terms of brightness, contrast, and detail fidelity. In addition, a dataset is constructed with speckle images degraded by various non-uniform illumination and corresponding clear references.</p><h3>Results</h3><p>The Speckle-GAN model is evaluated with conventional image restoration methods. Both qualitative and quantitative evaluations demonstrate its superior capability in restoring clarity of speckle images degraded by non-uniform illumination shadows. Furthermore, DIC experiments under artificial non-uniform lighting are conducted, where the measurement errors are significantly reduced by applying the proposed method.</p><h3>Conclusions</h3><p>The proposed method effectively mitigates illumination-induced degradation in speckle images, thereby improving accuracy and robustness of DIC under challenging lighting conditions.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"627 - 645"},"PeriodicalIF":2.4,"publicationDate":"2026-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147737989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. de J Villalobos Luna, P. Lopez Cruz, D. F. Ledezma Ramírez, J. G. Puente Córdova
{"title":"Experimental Analysis of Energy Dissipation in Structural Adhesive Joints: Relationship Between Hysteresis and Modal Damping","authors":"J. de J Villalobos Luna, P. Lopez Cruz, D. F. Ledezma Ramírez, J. G. Puente Córdova","doi":"10.1007/s11340-026-01278-2","DOIUrl":"10.1007/s11340-026-01278-2","url":null,"abstract":"<div><h3>Background</h3><p>Researchers have studied shift damping in structures because it is more sensitive than shift frequencies and can indicate structural damage. Changes in hysteresis damping also suggest modifications within structures during cyclic tests. However, the relationship between these two approaches has not been documented, presenting a potential opportunity for research into damage indicators in structural health monitoring.</p><h3>Objective</h3><p>This study examines energy dissipation during the evolution of cycling tests in structural adhesive joints to validate the equivalence between modal and hysteresis damping.</p><h3>Methods</h3><p>Experimental analysis was conducted on test coupons of single-lap adhesive joints mounted on aluminum substrates. A universal cyclic testing machine and vibration data acquisition systems were employed. Hysteresis loops were measured to estimate dissipation energy across the entire cycling process until failure. Concurrently, the frequency response function was measured using an impact hammer, and modal damping was estimated via the half-power method during postprocessing.</p><h3>Results</h3><p>The damping progression followed a bathtub-like behavior, which could predict the residual life of the joints. Changes in measured damping indicate that hysteresis-estimated damping and the sum of modal damping across different resonant frequencies exhibit similar patterns during the cycling process.</p><h3>Conclusions</h3><p>An experimental relationship between hysteresis damping and modal damping during cyclic testing has been established. These findings support the utility of modal and hysteresis damping estimations in enhancing structural health monitoring techniques.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"66 4","pages":"615 - 626"},"PeriodicalIF":2.4,"publicationDate":"2026-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147738058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}