Eye & Contact Lens最新文献

筛选
英文 中文
Thin-Flap Laser In Situ Keratomileusis-Associated Dry Eye: A Comparative Study Between Femtosecond Laser and Mechanical Microkeratome-Assisted Laser In Situ Keratomileusis. 薄瓣激光原位角膜磨磨术治疗干眼症:飞秒激光与机械微角膜辅助激光原位角膜磨磨术的比较研究。
IF 2.3
Eye & Contact Lens Pub Date : 2022-01-01 DOI: 10.1097/ICL.0000000000000850
Mahmoud Abdel-Radi, Hazem Abdelmotaal, Mohamed Anwar
{"title":"Thin-Flap Laser In Situ Keratomileusis-Associated Dry Eye: A Comparative Study Between Femtosecond Laser and Mechanical Microkeratome-Assisted Laser In Situ Keratomileusis.","authors":"Mahmoud Abdel-Radi,&nbsp;Hazem Abdelmotaal,&nbsp;Mohamed Anwar","doi":"10.1097/ICL.0000000000000850","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000850","url":null,"abstract":"<p><strong>Objective: </strong>To assess and compare postlaser in situ keratomileusis (LASIK) dry eye after LASIK with planned thin flaps created by a femtosecond laser (FS) and mechanical microkeratome (MK).</p><p><strong>Methods: </strong>Patients were stratified according to the flap creation technique into FS and MK groups with planned 100 μm flap thickness in all eyes. Dry eye parameters including tear film break-up time (TBUT), Schirmer I test, ocular surface disease index (OSDI), and lower tear meniscus height and area (tear meniscus height [TMH] and tear meniscus area [TMA]) were assessed before surgery and at 3 and 6 months after surgery.</p><p><strong>Results: </strong>The study included 102 eyes of 55 patients (52 eyes underwent FS-LASIK/50 eyes underwent MK-LASIK). The preoperative characteristics including age, gender, and spherical equivalents were similar in both groups (P>0.05). The difference in postoperative flap thickness was statistically significant (P<0.05). In each group, dry eye parameters showed a statistically significant worsening (P value<0.001) at 3 months with later significant improvement at 6 months but did not return to baseline. The mean TBUT, Schirmer I, and lower TMH and TMA were statistically higher, and the mean OSDI was statistically lower in FS-LASIK than the MK-LASIK group at both 3 and 6 months (P value<0.001). The depth of ablation had a statistically significant correlation with Schirmer I at 6 months and OSDI at both 3 and 6 months post-LASIK (P<0.05).</p><p><strong>Conclusion: </strong>The use of femtosecond laser technology in performing thin-Flap LASIK eye surgeries has improved the outcome of post-LASIK dry eye when compared with the mechanical microkeratome.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"20-26"},"PeriodicalIF":2.3,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39538883","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Crosslinking in Microbial Keratitis: Where Are We Today? 微生物性角膜炎的交联研究进展如何?
IF 2.3
Eye & Contact Lens Pub Date : 2022-01-01 DOI: 10.1097/ICL.0000000000000864
Ömür Uçakhan
{"title":"Crosslinking in Microbial Keratitis: Where Are We Today?","authors":"Ömür Uçakhan","doi":"10.1097/ICL.0000000000000864","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000864","url":null,"abstract":"","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"1-2"},"PeriodicalIF":2.3,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39778203","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes. 动态超高速Scheimpflug成像在正常和圆锥角膜中角膜变形响应参数的可重复性。
IF 2.3
Eye & Contact Lens Pub Date : 2022-01-01 DOI: 10.1097/ICL.0000000000000845
Maria A Henriquez, Isabel Gomez, Maythe Camino-Quezada, Luis Izquierdo, José Chauca, Perry S Binder
{"title":"Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes.","authors":"Maria A Henriquez,&nbsp;Isabel Gomez,&nbsp;Maythe Camino-Quezada,&nbsp;Luis Izquierdo,&nbsp;José Chauca,&nbsp;Perry S Binder","doi":"10.1097/ICL.0000000000000845","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000845","url":null,"abstract":"<p><strong>Purpose: </strong>To assess the repeatability of corneal dynamic response (CDR) parameters in normal and keratoconus (KC) eyes using ultra high-speed Scheimpflug imaging.</p><p><strong>Methods: </strong>Prospective, comparative, observational study, including eyes of 112 patients that underwent high-speed Scheimpflug imaging analysis (Corvis ST, OCULUS). Twenty-one CDR parameters were evaluated to asses repeatability using: coefficient of repeatability (CR), coefficient of variation, intraclass correlation coefficient (ICC) and within-subject SD. Three consecutive measurements by the same operator were performed for each eye.</p><p><strong>Results: </strong>There were no significant differences between the three consecutive measurements for all parameters in both normal and KC eyes. 71.42% (15 of the 21 parameters evaluated) and 85.71% (18 of the 21 parameters) were highly repeatable in the normal and KC group, respectively. The tomographic biomechanical index (TBI), corneal biomechanical index (CBI), and stiffness parameter (SPA1) showed an ICC of 0.978, 0.954, and 0.958 in normal and 0.982, 0.892, and 0.978 in KC eyes, respectively. The CR in normal eyes for TBI, CBI, and SPA1 were 0.169, 0.242, and 14.12, respectively, and for KC eyes 0.06, 0.23, and 13.64, respectively.</p><p><strong>Conclusions: </strong>Most of the corneal dynamic response parameters were highly repeatable in normal and KC eyes.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"14-19"},"PeriodicalIF":2.3,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39826547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study. 高度近视眼植入2种晶状体后房型人工晶状体视力评价的比较研究。
IF 2.3
Eye & Contact Lens Pub Date : 2022-01-01 DOI: 10.1097/ICL.0000000000000854
Ayushi Sinha, Rajesh Sinha, Vinay Gupta, Rinky Agarwal, Prafulla K Maharana, Tushar Agarwal, Namrata Sharma, Jeewan Singh Titiyal
{"title":"Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study.","authors":"Ayushi Sinha,&nbsp;Rajesh Sinha,&nbsp;Vinay Gupta,&nbsp;Rinky Agarwal,&nbsp;Prafulla K Maharana,&nbsp;Tushar Agarwal,&nbsp;Namrata Sharma,&nbsp;Jeewan Singh Titiyal","doi":"10.1097/ICL.0000000000000854","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000854","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia.</p><p><strong>Methods: </strong>A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault.</p><p><strong>Results: </strong>The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073).</p><p><strong>Conclusion: </strong>Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"38-44"},"PeriodicalIF":2.3,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39622186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Lens in Primary Congenital Glaucoma Eyes Treated by Combined Angle and Filtering Surgery. 角滤联合手术治疗先天性青光眼晶状体。
IF 2.3
Eye & Contact Lens Pub Date : 2021-11-01 DOI: 10.1097/ICL.0000000000000789
Nader Bayoumi, Nihal El Shakankiry, Mohamed Fouad, Eman Nabil Elsayed
{"title":"Lens in Primary Congenital Glaucoma Eyes Treated by Combined Angle and Filtering Surgery.","authors":"Nader Bayoumi,&nbsp;Nihal El Shakankiry,&nbsp;Mohamed Fouad,&nbsp;Eman Nabil Elsayed","doi":"10.1097/ICL.0000000000000789","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000789","url":null,"abstract":"<p><strong>Purpose: </strong>To report on the changes in the natural crystalline lens in primary congenital glaucoma (PCG) eyes that had undergone previous combined angle-filtering surgery with antimetabolites.</p><p><strong>Settings: </strong>The pediatric ophthalmology unit of the ophthalmology department of Alexandria Main University Hospital.</p><p><strong>Design: </strong>A retrospective chart review.</p><p><strong>Methods: </strong>A retrospective chart review of patients presenting with and operated (by combined angle-filtering surgery with antimetabolites) for PCG in the period from 2005 to 2018. Any lens pathology was noted as well as the management and the outcome.</p><p><strong>Results: </strong>The records of 422 children (613 eyes) were reviewed. Lens pathology was noted in 54 (8.8%) eyes. Abnormalities in lens clarity (cataract) were detected in 31 (56%) eyes, and abnormalities in lens position (subluxation) were detected in 24 (44%) eyes. Management options included observation (in 28 eyes), lensectomy for aphakia (in 14 eyes), lensectomy with in the bag intraocular lens (IOL) implantation (in 11 eyes), and lensectomy with iris-fixated IOL (in 1 eye). Elevation of intraocular pressure (IOP) occurred in only 4 eyes (of 26 operated eyes, 15.3%) after lens extraction.</p><p><strong>Conclusions: </strong>Changes in the natural crystalline lens clarity and/or position occurred in 8.8% (54 of 613) of PCG eyes operated by combined angle-filtering surgery with antimetabolites. Lens extraction was a relatively safe procedure with only 15% (4 of 26) of eyes suffering an elevation of IOP after lens extraction.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"611-616"},"PeriodicalIF":2.3,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"38807814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Incidence and Risk Factors of Ocular Hypertension and Glaucoma in Patients With Acanthamoeba Keratitis. 棘阿米巴角膜炎患者高眼压和青光眼的发病率及危险因素。
IF 2.3
Eye & Contact Lens Pub Date : 2021-11-01 DOI: 10.1097/ICL.0000000000000824
Adi Mohammed Al Owaifeer, Sarah Al-Omair, Shaimaa Alrefaie, Saad H Alenezi, Sami Al-Shahwan
{"title":"Incidence and Risk Factors of Ocular Hypertension and Glaucoma in Patients With Acanthamoeba Keratitis.","authors":"Adi Mohammed Al Owaifeer,&nbsp;Sarah Al-Omair,&nbsp;Shaimaa Alrefaie,&nbsp;Saad H Alenezi,&nbsp;Sami Al-Shahwan","doi":"10.1097/ICL.0000000000000824","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000824","url":null,"abstract":"<p><strong>Objectives: </strong>To determine the incidence of ocular hypertension (OHT) and glaucoma in patients with acanthamoeba keratitis (AK) and to outline the risk factors for the development of glaucoma.</p><p><strong>Methods: </strong>A retrospective review of patients diagnosed with AK at our institute during the period from 2000 to 2018. The main outcome measures were the incidence of OHT and glaucoma, and risk factors for the development of glaucoma.</p><p><strong>Results: </strong>Fifty-two eyes diagnosed with AK were included. The incidence of OHT and glaucoma was 51.9% and 32.7%, respectively. The mean duration from disease onset to the first attack of elevated intraocular pressure was 8.4±16.6 months. The use of corticosteroids in the treatment regimen was significantly associated with the development of glaucoma (odds ratio, 3.93; 95% confidence interval, 0.96-16.15; P=0.049). At the last follow-up visit, both patients with glaucoma and nonglaucoma patients had improved visual acuity without a difference in the mean amount of logarithm of the minimum angle of resolution acuity improvement among them (0.56±0.91 vs. 0.67±0.87, P=0.686).</p><p><strong>Conclusion: </strong>Our findings confirm that OHT and glaucoma are frequent complications in AK. Patients treated with a regimen containing corticosteroids are at a higher risk; thus, they should receive close intraocular pressure monitoring.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"588-591"},"PeriodicalIF":2.3,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39264331","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Negative Corneal Fluorescein Staining as an Exceptionally Early Sign of Acanthamoeba Keratitis: A Case Report. 角膜荧光素染色阴性是棘阿米巴角膜炎的异常早期征象:1例报告。
IF 2.3
Eye & Contact Lens Pub Date : 2021-11-01 DOI: 10.1097/ICL.0000000000000825
Ilayda Korkmaz, Ozlem Barut Selver, Cem Simsek, Melis Palamar
{"title":"Negative Corneal Fluorescein Staining as an Exceptionally Early Sign of Acanthamoeba Keratitis: A Case Report.","authors":"Ilayda Korkmaz,&nbsp;Ozlem Barut Selver,&nbsp;Cem Simsek,&nbsp;Melis Palamar","doi":"10.1097/ICL.0000000000000825","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000825","url":null,"abstract":"<p><strong>Objectives: </strong>To report the negative fluorescein staining as an early sign of Acanthamoeba keratitis (AK).</p><p><strong>Methods: </strong>Case report and brief review of related literature.</p><p><strong>Report of case: </strong>A 30-year-old, contact lens wearer, woman presented with mild irritation and pain in the right eye. The best-corrected visual acuity (BCVA) was 20/20 in both eyes. Slit-lamp examination revealed a peripheral corneal infiltration. Empirical antimicrobial therapy was initiated. Within the third day, peripheral corneal opacity regressed but a Y-shaped linear epitheliopathy with a negative fluorescein staining, because of a ridge-like epithelial irregularity, was observed in the central cornea. Clinical findings progressed rapidly. Confocal microscopy revealed hyper-reflective cysts with the typical double-ring sign consistent with AK. Therefore, topical chlorhexidine and propamidine were initiated. Clinical findings regressed subsequently. The final BCVA was 20/20 in both eyes.</p><p><strong>Conclusion: </strong>Acanthamoeba keratitis usually manifest as superficial epitheliopathy and progresses to the stroma. Findings may be obscure or atypical; comprehensive and careful examination may reveal mild findings in the early stages.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"622-624"},"PeriodicalIF":2.3,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39275416","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Quadrant-Specific Changes in Corneal and Tear Fluid Reservoir Thickness for After 2 Hours of Wear. 磨损2小时后角膜和泪液储层厚度的象限特异性变化。
IF 2.3
Eye & Contact Lens Pub Date : 2021-11-01 DOI: 10.1097/ICL.0000000000000808
Cherie B Nau, Samantha Dodda, David O Hodge, Muriel M Schornack
{"title":"Quadrant-Specific Changes in Corneal and Tear Fluid Reservoir Thickness for After 2 Hours of Wear.","authors":"Cherie B Nau,&nbsp;Samantha Dodda,&nbsp;David O Hodge,&nbsp;Muriel M Schornack","doi":"10.1097/ICL.0000000000000808","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000808","url":null,"abstract":"<p><strong>Objective: </strong>To measure corneal swelling and thickness of the tear fluid reservoir (TFR) after wearing scleral lenses (SLs).</p><p><strong>Methods: </strong>Thirty-five participants had 1 eye fitted with each of three SLs (15.0-mm Jupiter, 18.2-mm Jupiter, and 18.0-mm Digiform). Scheimpflug images were obtained before wear, after application, after 2 hr of wear, and after removal. Initial and final TFR thickness and corneal thickness were measured in the central cornea and 3 mm from the center in the superior, inferior, temporal, and nasal quadrants.</p><p><strong>Results: </strong>Corneal thickness increased with wear, but no between-lens differences were observed in the superior (P=0.09), inferior (P=0.38), or temporal (P=0.53) quadrants. The greatest change in central and nasal cornea thickness was with the 15.0-mm SL (P<0.001). All areas showed settling, with no between-lens differences. Greater final TFR thickness was noted for the superior and nasal quadrants with the 18.0-mm SL (P<0.001), and less final TFR thickness was noted in the inferior (P<0.001) and temporal (P<0.001) quadrants with the 15.0-mm SL. Corneal thickness was not associated with the final TFR thickness.</p><p><strong>Conclusions: </strong>The greatest corneal swelling was observed in the inferior quadrant with the 15.0-mm SL, although this lens had the least TFR thickness inferiorly. TFR thickness alone did not account for observed corneal swelling.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"582-587"},"PeriodicalIF":2.3,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39536915","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Changes in Limbal Optical Coherence Tomography Angiography Outcomes in Patients With Overnight Contact Lens Wear. 夜间佩戴隐形眼镜患者角膜缘光学相干断层血管造影结果的变化。
IF 2.3
Eye & Contact Lens Pub Date : 2021-10-01 DOI: 10.1097/ICL.0000000000000819
Basak Bostanci Ceran, Serdar Ozates, Hasan Basri Arifoglu, Emrullah Tasindi
{"title":"Changes in Limbal Optical Coherence Tomography Angiography Outcomes in Patients With Overnight Contact Lens Wear.","authors":"Basak Bostanci Ceran,&nbsp;Serdar Ozates,&nbsp;Hasan Basri Arifoglu,&nbsp;Emrullah Tasindi","doi":"10.1097/ICL.0000000000000819","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000819","url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the perilimbal vasculature of patients who wear contact lenses (CLs) overnight with optical coherence tomography angiography (OCTA) and compare the results with healthy population.</p><p><strong>Methods: </strong>Forty-two patients were included in this observational study. The OCTA imaging was performed in the temporal quadrant of the perilimbal region using a swept-source optical coherence tomography system (Triton DRI-OCT; Topcon Corporation, Tokyo, Japan). The assessments were made in two depths: starting from the conjunctival epithelium to 200 μm scleral depth and the scleral depth between 200 and 1,000 μm. The vessel density, vessel length density, vessel diameter index, and fractal dimension were the main outcomes and compared between overnight CL users and healthy population.</p><p><strong>Results: </strong>Twenty-two patients who have been using CLs overnight for at least 3 months and 20 healthy individuals were included in the study. The vessel density at the superficial layer was significantly higher in the CL group compared with the control group (P<0.001). Vessel diameter index, vessel length density, and fractal dimension at the superficial layer did not differ between the groups (P>0.05 for all). There was no difference in the vessel density, vessel diameter index, vessel length density, and fractal dimension in the deep layer between the groups (P>0.05 for all).</p><p><strong>Conclusions: </strong>Patients who use CL overnight exhibit increased vessel density in the superficial layers of the perilimbal region, which may suggest new vessel formation in the conjunctiva. Anterior segment OCTA may be useful to evaluate the initial changes in limbal vasculature in CL users.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"552-554"},"PeriodicalIF":2.3,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39432021","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Polymicrobial Keratitis: Risk Factors, Clinical Characteristics, Bacterial Profile, and Antimicrobial Resistance. 多微生物性角膜炎:危险因素、临床特征、细菌特征和抗菌素耐药性。
IF 2.3
Eye & Contact Lens Pub Date : 2021-10-01 DOI: 10.1097/ICL.0000000000000851
{"title":"Polymicrobial Keratitis: Risk Factors, Clinical Characteristics, Bacterial Profile, and Antimicrobial Resistance.","authors":"","doi":"10.1097/ICL.0000000000000851","DOIUrl":"https://doi.org/10.1097/ICL.0000000000000851","url":null,"abstract":"","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"580"},"PeriodicalIF":2.3,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"39432023","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书