{"title":"New Concept in Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA)","authors":"A. E. Dabiri, Matthew D. Martin, G. Kassab","doi":"10.32604/mcb.2019.07310","DOIUrl":"https://doi.org/10.32604/mcb.2019.07310","url":null,"abstract":": The world-wide impact of traumatic injury and associated hemorrhage on human health and well-being is significant. Methods to manage bleeding from sites within the torso, referred to as non-compressible torso hemorrhage (NCTH), remain largely limited to the use of conventional operative techniques. The overall mortality rate of patients with NCTH is approximately 50%. Studies from the wars in Afghanistan and Iraq have suggested that up to 80% of potentially survivable patients die as a result of uncontrolled exsanguinating hemorrhage. The commercially available resuscitative endovascular balloon occlusion of the aorta (REBOA) is a percutaneous device for the rapid control of torso hemorrhage in trauma. A compliant balloon is inserted via the femoral artery and inflated in the thoracic or abdominal aorta, providing inflow control of the abdomen, pelvis, or groin/lower extremities. Recent studies indicate that REBOA carries an inherent risk of aortic injury due to over-inflation and possible risk of aortic or iliac artery rupture. A new approach is to resolve the issue of balloon sizing and over-inflation. We propose a novel concept to be used in trauma facility for arterial occlusion to eliminate arterial injury and the risk of vascular rupture through real time balloon diameter profile measurements to ensure proper inflation. The proposed concept, called Smart Resuscitative Endovascular Balloon Occlusion (SREBO) will be novel in the following aspects: 1) It will have electrical conductance-based navigation technology to target the desired site of balloon deployment in the aorta, 2) The balloon can determine the time of proper inflation using electrical conductance catheter technology. This technology would eliminate the risk of arterial rupture and simplify the procedure in the trauma facility or medical clinics without significant training. The results can be displayed on a handheld device. This novel device has the potential to save civilians in trauma or soldiers injured on the battlefield.","PeriodicalId":48719,"journal":{"name":"Molecular & Cellular Biomechanics","volume":"8 3 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86652076","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Kinematics and Surface Electromyography Characteristics of Round Kick of Martial Arts Athletes","authors":"Xin Wang","doi":"10.32604/mcb.2020.011236","DOIUrl":"https://doi.org/10.32604/mcb.2020.011236","url":null,"abstract":"In order to improve the level of athletes, modern scientific and technological means can be used to understand the characteristics and rules of movement. This study mainly analyzed the whip leg technique of Sanda athletes. Taking ten athletes as an example, the kinematics and surface electromyography (sEMG) data of them were measured, calculated and sorted out when they were doing the action of round kick. The results showed that the movement completion time of the first-level athletes was shorter, 0.34 ± 0.33 s. In the stage of turning hip and hitting, the angle of hip joint increased significantly. In the stage of turning hip, there was a significant difference in the angle of hip joint between different levels of athletes (p < 0.05), and there was no significant difference in other kinematics characteristics. In the aspect of sEMG, the duration of muscle discharge of the first-level athletes was shorter, but there was no significant difference in integrated electromyogram (IEMG) and root mean square (RMS). The experimental results reveal the importance of hip joint in the course of round kick and provide some theoretical bases for improving the level of athletes and carrying out targeted training.","PeriodicalId":48719,"journal":{"name":"Molecular & Cellular Biomechanics","volume":"35 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73670971","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Thi, Q. Le, V. Stoldt, N. Tran, Anh T. K. Le, Khon Huynh
{"title":"Morphologies of Fibronectin Fibrils Formed under Shear Conditions and Their\u0000Cellular Adhesiveness Properties","authors":"P. Thi, Q. Le, V. Stoldt, N. Tran, Anh T. K. Le, Khon Huynh","doi":"10.32604/mcb.2020.09643","DOIUrl":"https://doi.org/10.32604/mcb.2020.09643","url":null,"abstract":": Fibrillar fi bronectin (FFN) is a biological active form of FN which form linear and branched meshwork around cells and support cellular activities. Previous studies have demonstrated that shear stress can induce cell-free FN fi brillogenesis. In this study, we further examined the effect of shear stress conditions on morphology of formed FFN and preliminarily looked for relationship between FFN ’ s morphology and cell adhesion. Plasma FN at 50 µg/ml was perfused through channel slides at shear rates of 500 s -1 or 4000 s -1 . Our results showed that there were four FFN structures formed: (1) FN nodules, (2) fi bril in different sizes (3) with or without nodule attachment, and (4) fi brillar matrix. At 4000 s -1 , FFN fi brils was formed within the fi rst 10 min and reached the highest surface coverage only after 20 min. In contrast, FFN formation was signi fi cant more slowly at 500 s -1 at which only FN nodules and small fi brils were formed. Platelets bound on thin layer of FN and rarely found on large FN fi brils. In contrast, fi broblast stretched their shape on platform of FFN matrix and bound actively to all types of FFNs. Taken together, our data suggests a morphological dependent biological activity of FFN. adhesion assays were performed on FFN with diverse morphologies. Our microscopic analysis","PeriodicalId":48719,"journal":{"name":"Molecular & Cellular Biomechanics","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85129584","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}