Buildings最新文献

筛选
英文 中文
Numerical Simulation of Mechanical Characteristics and Safety Performance for Pre-Cracked Tunnel Lining with the Extended Finite Element Method 用扩展有限元法对预开裂隧道衬砌的机械特性和安全性能进行数值模拟
IF 3.8 3区 工程技术
Buildings Pub Date : 2024-01-02 DOI: 10.3390/buildings14010123
Xin Lu, Yong Liu, Xiaolong Hou, Cai Chen, Ruidan Gao
{"title":"Numerical Simulation of Mechanical Characteristics and Safety Performance for Pre-Cracked Tunnel Lining with the Extended Finite Element Method","authors":"Xin Lu, Yong Liu, Xiaolong Hou, Cai Chen, Ruidan Gao","doi":"10.3390/buildings14010123","DOIUrl":"https://doi.org/10.3390/buildings14010123","url":null,"abstract":"The service performance of tunnel lining is affected by crack properties and development states. In this paper, numerical simulation models were established to investigate the mechanics characteristics and safety performance for lining structures under different cracks based on the extended finite element method (XFEM). Analyze multiple quantitative factors in simulation, including changes in crack location, crack length, and crack distribution range in the lining structure. The axial force and bending moment of the preset cracks in the lining structures were first studied. The maximum safety factor attenuation rate (Dkmax) was proposed to analyze the impact of longitudinal and annular cracks on the safety performance. The axial force at the vault of the lining arch is the most significantly affected by the combined longitudinal cracks at multiple locations. When the length of a longitudinal crack increases from 1 m to 6 m, the axial force value at the crack point decreases by 33.77%, 36.15%, and 11.32%. However, the bending moment value increases by 4.47 times, 2.50 times, and 1.69 times. Under the influence of longitudinal cracks in an “arch crown + arch shoulder”, “arch crown + arch waist”, and “arch crown + arch shoulder + arch waist”, the axial force in the arch vault increased by 21.55%, decreased by 17.52%, and decreased by 13.45%. The distribution pattern of the bending moment under the influence of circumferential cracks shows convexity at the arch shoulder and arch foot, and concavity at the arch waist and side walls. The safety factor scatter curve with longitudinal cracks shows a gradual transition from a “W” shape to a “U” shape. The safety factor curve with circumferential cracks presents an approximately symmetrical wave-shaped distribution.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"57 1","pages":""},"PeriodicalIF":3.8,"publicationDate":"2024-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139452725","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimizing Rural Pavements with SBS-Modified Asphalt Binders and Petroleum Resin 用 SBS 改性沥青胶结料和石油树脂优化农村路面
IF 3.8 3区 工程技术
Buildings Pub Date : 2024-01-02 DOI: 10.3390/buildings14010116
Je-won Kim, Kyungnam Kim, Tri Ho Minh Le
{"title":"Optimizing Rural Pavements with SBS-Modified Asphalt Binders and Petroleum Resin","authors":"Je-won Kim, Kyungnam Kim, Tri Ho Minh Le","doi":"10.3390/buildings14010116","DOIUrl":"https://doi.org/10.3390/buildings14010116","url":null,"abstract":"This study addresses the imperative for enhancing asphalt mixtures tailored for rural pavements, focusing on optimizing RAP mixtures with styrene–butadiene–styrene (SBS)-modified asphalt binders incorporating petroleum resin and oil. Through systematic investigation, the study examines the impact of varying RAP content (25% and 50%) and two SBS-modified asphalt binder types (Type 1 and Type 2) on mechanical properties and sustainability. Laboratory tests reveal that the mix of 25% RAP + 75% Type 1 exhibits exceptional flexibility, evidenced by a high ductility value of 880 mm at 25 °C, enhancing pavement resilience. Conversely, the 50% RAP + 50% Type 2 mixture displays vulnerability to fatigue cracking, while 25% RAP + 75% Type 1 demonstrates superior resistance, with a fatigue vulnerability value of 1524 kPa. The Hamburg Wheel Tracking test highlights the influence of RAP content on rut depth, with the mix of 50% RAP + 50% Type 1 achieving the lowest rutting at 3.9 mm. Overlay test results show the mix of 25% RAP + 75% Type 2’s resilience, with the lowest load reduction at 64.5%, while the mix of 50% RAP + 50% Type 1 exhibits substantial load reduction at 82.1%. Field tests unveil differences in pavement bearing capacities, with the mix of 25% RAP + 75% Type 2 demonstrating a remarkable elastic modulus of 58.5 MPa, indicating heightened bearing capacity. The investigation underscores the significant role of SBS-modified asphalt binders with incorporated petroleum resin and oil in enhancing fatigue resistance for sustainable rural pavements.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"56 1","pages":""},"PeriodicalIF":3.8,"publicationDate":"2024-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139452761","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparison of Local Mean Age of Air between Displacement Ventilation System and Mixing Ventilation System in Office Heating Conditions during Winter 冬季办公室供暖条件下置换式通风系统与混合式通风系统的局部平均风龄比较
IF 3.8 3区 工程技术
Buildings Pub Date : 2024-01-01 DOI: 10.3390/buildings14010115
Ik-Hyun An, Su-Hoon Park, Yong-Ho Lee, Chang-Hoon Lee, Sang-Bum Seo, Sang-Hyun Cho, Hyun-Woo Lee, S. Yook
{"title":"Comparison of Local Mean Age of Air between Displacement Ventilation System and Mixing Ventilation System in Office Heating Conditions during Winter","authors":"Ik-Hyun An, Su-Hoon Park, Yong-Ho Lee, Chang-Hoon Lee, Sang-Bum Seo, Sang-Hyun Cho, Hyun-Woo Lee, S. Yook","doi":"10.3390/buildings14010115","DOIUrl":"https://doi.org/10.3390/buildings14010115","url":null,"abstract":"A novel displacement ventilation system (DVS) was designed using a four-way cassette fan coil unit (FCU) and air purifiers (APs) for supplying clean air. The proposed DVS in this study involved drawing indoor air through the FCU and diffusers installed in the ceiling, controlling air temperature using the FCU, and then discharging it back into the office through the APs placed on the floor. The comparative ventilation system considered was the typical mixing ventilation system (MVS) that intakes and exhausts indoor air using diffusers installed on the ceiling. The local mean age of air was used as an index to compare indoor air quality between DVS and MVS under winter heating conditions. It was found that the DVS was more effective in improving indoor air quality in winter than the MVS. Moreover, compared to the MVS, utilizing the DVS designed in this study resulted in the advantage of a much more uniform air temperature variation in the office space. Therefore, it is anticipated that modifying the structure of an indoor space with an FCU installed in the ceiling and APs on the floor to use the DVS designed in this study would greatly assist in enhancing indoor air quality.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"127 18","pages":""},"PeriodicalIF":3.8,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139128397","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimal Design of a Novel Large-Span Cable-Supported Steel–Concrete Composite Floor System 新型大跨度拉索支撑钢-混凝土复合楼板系统的优化设计
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010113
Meiwen Tan, Yifan Wu, Wenhao Pan, Guoming Liu, Wei Chen
{"title":"Optimal Design of a Novel Large-Span Cable-Supported Steel–Concrete Composite Floor System","authors":"Meiwen Tan, Yifan Wu, Wenhao Pan, Guoming Liu, Wei Chen","doi":"10.3390/buildings14010113","DOIUrl":"https://doi.org/10.3390/buildings14010113","url":null,"abstract":"This paper optimizes the design of a novel large-span cable-supported steel–concrete composite floor system in a simply supported single-span, single-strut configuration, aiming for cost-effective solutions and minimal steel consumption. The optimization considers various cross-sectional dimensions, adhering to building standards and engineering practices, and is based on a non-linear programming (NLP) algorithm. Parameters of live loads ranging from 2 to 10 kN/m2 and spans from 20 to 100 m are considered. The optimization results show that cable-supported composite floors with a single strut exhibit robust economic feasibility for spans of less than 80 m and live loads under 8 kN/m2. Compared to conventional composite floors with welded I-beams, the cable-supported system offers more cost-effective cross-sections and reduces steel consumption. The savings in economically equivalent steel consumption range from 20% to 60%. Discussion on the area ratio of cables to steel beam in the optimal cross-section reveals that the secondary load-bearing system (i.e., bending of the main beam with an effective span length of L/2) may require more steel in cases of ultra-large spans. Therefore, the economical efficiency of cable-supported composite beams with multiple struts and smaller effective span lengths warrants further exploration in future studies.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"105 21","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139133719","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Progressive Collapse Resistance Assessment of a Multi-Column Frame Tube Structure with an Assembled Truss Beam Composite Floor under Different Column Removal Conditions 带装配式桁架梁复合楼板的多柱框架管式结构在不同拆柱条件下的抗渐进式坍塌能力评估
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010111
Rongguo Zhao, Guangfei Chen, Zaihua Zhang, Wei Luo
{"title":"Progressive Collapse Resistance Assessment of a Multi-Column Frame Tube Structure with an Assembled Truss Beam Composite Floor under Different Column Removal Conditions","authors":"Rongguo Zhao, Guangfei Chen, Zaihua Zhang, Wei Luo","doi":"10.3390/buildings14010111","DOIUrl":"https://doi.org/10.3390/buildings14010111","url":null,"abstract":"To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with an assembled truss beam composite floor (ATBCF), pushdown analysis and nonlinear dynamic analysis are conducted for such a structure using the alternate load path (ALP) method. The bearing capacities of the remaining structures under three different work conditions, which are the side middle column removal, the edge middle column removal, and the corner column removal, are individually studied, and the collapse mechanism of the remaining structures is analyzed based on the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient is discussed. The results indicate that the residual bearing capacity of the remaining structure following the bottom corner column removal is higher than that of the one following the side or edge middle column removal, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times the period of the first-order vertical vibration mode of the remaining structure, and it is suitable to set the dynamic amplification coefficient as 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"122 20","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139132773","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Geopolymer Made from Kaolin, Diatomite, and Rice Husk Ash for Ceiling Thermal Insulation 用于天花板隔热的高岭土、硅藻土和稻壳灰土工聚合物
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010112
Cinthya Alvarado, Daniel Martínez-Cerna, Hernán Alvarado-Quintana
{"title":"Geopolymer Made from Kaolin, Diatomite, and Rice Husk Ash for Ceiling Thermal Insulation","authors":"Cinthya Alvarado, Daniel Martínez-Cerna, Hernán Alvarado-Quintana","doi":"10.3390/buildings14010112","DOIUrl":"https://doi.org/10.3390/buildings14010112","url":null,"abstract":"In this study, geopolymers made of metakaolin (MK), diatomite (D), and rice husk ash (RHA) were developed for ceiling thermal insulation in houses to provide protection against cold temperatures. The influence of the constituent mixing ratio and the temperature of curing on the heat conductivity and compressive strength of the geopolymer was investigated. Specimens were formed according to a 10-level mix design with three replicates and subjected to curing at 40 °C and 80 °C. Heat conductivity and compressive strength were determined in accordance with established standards. The simplex lattice method was used to obtain the response surfaces, contour plots, and tracking curves. The geopolymers under study displayed a reduction in heat conductivity and an increase in compressive strength when the curing temperature was raised. The optimal mixing ratio to achieve a balance between the compressive strength and thermal conductivity of the geopolymers investigated was 0.50 MK and 0.50 RHA. Diatomite’s thermal insulation contribution is neutralized when crystals from the geopolymer gel fill the pore volume. The mixture’s optimal results were achieved when cured at 80 °C, demonstrating a thermal conductivity of 0.10 W/m·K and a compressive strength of 5.37 MPa.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"109 44","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139134363","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Exploring the Layout Optimization of Commercial Service Space Affecting Energy Consumption in Communities Using Machine Learning 利用机器学习探索影响社区能耗的商业服务空间布局优化
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010108
Yiwen Liu, Chun-Huei Liu, Xiaolong Wang, Junjie Zhang, Yang Yang, Yi Wang
{"title":"Exploring the Layout Optimization of Commercial Service Space Affecting Energy Consumption in Communities Using Machine Learning","authors":"Yiwen Liu, Chun-Huei Liu, Xiaolong Wang, Junjie Zhang, Yang Yang, Yi Wang","doi":"10.3390/buildings14010108","DOIUrl":"https://doi.org/10.3390/buildings14010108","url":null,"abstract":"The current design of commercial service spaces in many communities faces issues like incoherence, irrational resource allocation, and low utilization rates. These challenges contribute to increased energy consumption in communities, hindering the overall sustainable development of cities. As a representative community space in the urban environment, the commercial space within the campus requires continuous energy input. Its energy-efficient layout aligns with the principles of sustainable development. This paper uses the university campus as a case study to examine energy-efficient commercial space layout and community practices for environmental protection. Various factors influence the layout of inter-community commercial spaces, and the parameters for measuring the layout structure are diverse, considering the large sample size. Employing machine learning and big data processing to quantify development indicators across various industries and optimize their structure, resource allocation, and energy use has emerged as a viable tool for sustainable urban planning practices. This research seeks to utilize machine learning and data-driven optimization techniques to formulate a comprehensive framework for the sustainable allocation and design of business service spaces within communities. Firstly, we conduct a comprehensive investigation, which includes data collected by applying questionnaire surveys and field research, to assess and model the factors influencing the spatial layout of commercial services on university campuses. Secondly, the AEL machine learning model is constructed by combining the analytic hierarchy process to determine subjective weights, the entropy weight method to calculate objective weights, and the Lagrange algorithm to determine comprehensive weights. Thirdly, we assess and improve the layout of commercial service spaces. Then, by training and testing the Neural Network Model, we apply cases to ensure the accuracy of the machine learning calculation results. Qualitative analysis elucidates the varying factors influencing the sustainable layout of different commercial spaces. Quantitative analysis indicates that, within university campuses, the distance between commercial service spaces and residence halls is a crucial factor in fostering a more sustainable layout. Other significant factors include their location along major student routes and proximity to teaching areas. This study makes contributions not only to the specific field of optimizing commercial service space in communities but also to the broader discourse on sustainable urban development. It advances our understanding of the complex dynamics involved in crafting urban environments that are both efficient and environmentally friendly. Beyond theoretical considerations, the study provides practical solutions and recommendations applicable to implementing tangible improvements in resource allocation. These contributions aim to foster urban environments that a","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"103 5","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139133586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Integrating Latent Load into the Cooling Degree Days Concept for Current and Future Weather Projections 将潜热负荷纳入冷却度日概念,用于当前和未来天气预测
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010106
Sajid Mehmood, K. P. Amber, Muhammad Usman, Daniel Friedrich
{"title":"Integrating Latent Load into the Cooling Degree Days Concept for Current and Future Weather Projections","authors":"Sajid Mehmood, K. P. Amber, Muhammad Usman, Daniel Friedrich","doi":"10.3390/buildings14010106","DOIUrl":"https://doi.org/10.3390/buildings14010106","url":null,"abstract":"Rising temperatures, increase in population, and dense urban morphology have resulted in increased cooling energy demands. The conventional degree-days method to calculate cooling energy demand considers only the sensible heat load of air and neglects the latent component. This study aims to estimate the cooling degree days based on the heat index (by considering both the sensible and latent loads) for the current and future years (2050 and 2080). Further, the ventilation load index for each of these cities has been established to unlock the impact of ventilation on the building’s total energy consumption for current and future years. The results show that heat index-based degree days have a stronger relationship with the buildings’ cooling energy consumption and, therefore, can predict the cooling energy demand of buildings with 20% higher accuracy than conventional temperature-based degree days. Analysis shows that cooling degree-days and frequency of temperature above the comfort range continue to increase in Pakistan, highlighting increased degree-days in the range from 11.0 to 41.6% by 2050 and from 28.4 to 126.5% by 2080. Prompt actions are essential to enhance the resilience of Pakistan’s national grid to meet these future cooling energy demands.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"116 42","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139135490","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Overall and Local Wind Loads on Post-Installed Elevator Shaft of Existing Buildings 既有建筑安装后电梯井道的整体和局部风荷载
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010110
Haowen You, Chenxu Si, Xinwen Ma, Jingmiao Shang
{"title":"Overall and Local Wind Loads on Post-Installed Elevator Shaft of Existing Buildings","authors":"Haowen You, Chenxu Si, Xinwen Ma, Jingmiao Shang","doi":"10.3390/buildings14010110","DOIUrl":"https://doi.org/10.3390/buildings14010110","url":null,"abstract":"The glass curtain walls of post-installed elevator shafts in existing buildings can be damaged by local wind loads, and the serviceability of an elevator may be affected by excessive overall wind loads, especially in hurricane-prone areas. The overall and local wind load characteristics of elevator shafts with different arrangements (E-type, H-type, I-type) were studied using wind tunnel tests and computational fluid dynamics (CFD) numerical simulations. Firstly, high-frequency base balance wind tunnel tests of these elevator shafts with three arrangements were carried out to obtain the overall wind loads on the elevator shafts. Secondly, a CFD simulation was performed on the post-installed elevator shafts with three arrangements, obtaining the surface local wind pressure distribution of the elevator shafts under different wind directions. Finally, the wind-induced displacement responses of post-installed elevator shafts were analyzed. The results show that the aerodynamic interference of different elevator arrangements (E-type, H-type, I-type) and wind directions have significant effects on the overall local wind loads and wind-induced responses of the post-installed elevator, while the local wind loads on the area of the elevator door are less influenced by the elevator arrangement type than local wind loads on the surface and the overall wind loads of the elevator shafts. The results and conclusions may be helpful for developing the wind-resistant design of a post-installed elevator shaft.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"113 47","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139133492","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A New Proposal for the Interpretation of the Diagonal Compression Test on Masonry Wallettes: The Identification of Young’s Modulus, Poisson’s Ratio, and Modulus of Rigidity 解释砌石瓦片对角线压缩试验的新建议:杨氏模量、泊松比和刚度模量的鉴定
IF 3.8 3区 工程技术
Buildings Pub Date : 2023-12-31 DOI: 10.3390/buildings14010104
Elena Ferretti
{"title":"A New Proposal for the Interpretation of the Diagonal Compression Test on Masonry Wallettes: The Identification of Young’s Modulus, Poisson’s Ratio, and Modulus of Rigidity","authors":"Elena Ferretti","doi":"10.3390/buildings14010104","DOIUrl":"https://doi.org/10.3390/buildings14010104","url":null,"abstract":"This paper is the continuation of a previous study, which highlighted some inconsistencies in the RILEM guidelines for the interpretation of the diagonal compression test. Although improved compared to the ASTM guidelines, in fact, the RILEM guidelines underestimate the state of hydrostatic stress induced by the diagonal compression test at the center of the wallette. The new interpretation of the diagonal compression test proposed in this article shows that the RILEM guidelines actually underestimate both the hydrostatic and the deviatoric stress states at the center of the wallette. The new formulation complies with the linear elastic theory and allows us to use the diagonal compression test to identify the three elastic coefficients of masonry. In particular, it allows the identification of the Poisson ratio, which instead takes on a conventional value in the RILEM and ASTM guidelines. The difference of one order of magnitude between the conventional and proposed Poisson’s ratio is in agreement with the experimental results on another brittle material, namely concrete. Finally, the new proposal fills the gap between the results provided by the two tests usually performed to identify the shear behavior of masonry: the diagonal compression test and the shear-compression test.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":" 956","pages":""},"PeriodicalIF":3.8,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139136412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信