Civil and Environmental Engineering最新文献

筛选
英文 中文
Behavior and Load Capacity of Concrete Slab Reinforced by CFRP Bar and Strengthening by CFRP Laminates 碳纤维布加固混凝土板的受力性能
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0007
M. Medhlom, Entidhar Abed
{"title":"Behavior and Load Capacity of Concrete Slab Reinforced by CFRP Bar and Strengthening by CFRP Laminates","authors":"M. Medhlom, Entidhar Abed","doi":"10.2478/cee-2023-0007","DOIUrl":"https://doi.org/10.2478/cee-2023-0007","url":null,"abstract":"Abstract The most common FRP materials used are carbon fiber reinforced polymers (CFRPs), and glass fiber reinforced polymers (GFRPs). The use of CFRPs has grown rapidly in the construction industry, specifically in structural retrofitting, due to their strengthening property of CFRP. CFRPs are moreover high strength, lightweight, noncorrosive, and easy-to-install materials. In the present study, six reinforced concrete slab specimens included two control specimens reinforced by traditional steel reinforcements and the other reinforced by carbon fiber reinforced polymer CFRP bars without strengthening by laminated CFRP strips. The remaining four specimens are interiorly reinforced by CFRP bars and strengthened by CFRP laminates strips with different scheme layouts named Type 1 and Type 2. The specimens were tested under a uniformly distributed load applied at the top surface area of each specimen up to failure. The parameters considered in the present study are the amount of CFRP bars and CFRP laminates layout. Test results indicated that the strength carrying capacity and failure mode of tested specimens differ based on the steel reinforcement type and the presence of CFRP laminates layout.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"72 - 85"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48363967","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Retaining Wall - Parametric Study of the Method of Reinforcement 挡土墙加固方法的参数研究
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0034
Matúš Koleňák, I. Slávik
{"title":"Retaining Wall - Parametric Study of the Method of Reinforcement","authors":"Matúš Koleňák, I. Slávik","doi":"10.2478/cee-2023-0034","DOIUrl":"https://doi.org/10.2478/cee-2023-0034","url":null,"abstract":"Abstract The highway section on the D3 highway Hričovské Podhradie – Žilina – Strážov was carried out on the left branch of the highway body on the overpass and on the right branch on the embankment body. The stability of the embankment body was ensured by a geosynthetics reinforced retaining wall. The retaining wall was assembled from reinforced concrete prefabs, on which the uniaxial geogrids were attached. The article presents a numerical analysis of the deformations of this reinforced structure in the profile monitored by geotechnical monitoring. The results of the numerical analysis of the deformations of the retaining wall were confronted with geotechnical monitoring measurements. Geotechnical monitoring measurements confirmed the reality of the numerical model of the retaining wall. Verification of the reality of the numerical model of the retaining wall made it possible to use this model for a parametric study of the influence of the reinforcement method on the deformation of the face of the reinforced retaining wall. In the parametric study, the effects of the change in the horizontal length and vertical spacing of the reinforcement elements, as well as their interaction with the backfill soil on the deformation values of the face of the retaining wall are analyzed.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"380 - 390"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49660217","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigation of Wastes Plastic and Glass to Enhance Physical - Mechanical Properties of Fired Clay Brick 废塑料和玻璃提高烧结粘土砖物理力学性能的研究
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0022
Rasool Dakhil Mohsin, Hayder Al-khazraji, Sajid Kamil Zemam, Tiba Hameed Majeed, Al-zahraa Hayder Abbood
{"title":"Investigation of Wastes Plastic and Glass to Enhance Physical - Mechanical Properties of Fired Clay Brick","authors":"Rasool Dakhil Mohsin, Hayder Al-khazraji, Sajid Kamil Zemam, Tiba Hameed Majeed, Al-zahraa Hayder Abbood","doi":"10.2478/cee-2023-0022","DOIUrl":"https://doi.org/10.2478/cee-2023-0022","url":null,"abstract":"Abstract Around the world, large amounts of plastic and glass waste have been collected. This work is given as a way to reduce this material. This paper aims to investigate how fired clay bricks' physical and mechanical properties are affected by plastic/glass (P/G) powder. It is used as a replacement for clay, varying the plastic/glass content 00/20, 05/15, 10/10, 15/05, and 20/00 weight %. The ratio of soil to water remains constant 0.3. The maximum temperature is presented after three fire phases. The temperatures are 300 °C for the first, 600 °C for the second, and 900 °C for the third. Results for the physical properties showed an increase in the water absorption of clay brick specimens as the plastic content increased; in addition, efflorescence was increased with plastic powder. However, the density and firing shrinkage decrease with plastic quantity. Also, the experimental results showed a decrease in water absorption and efflorescence when the glass powder was increased. While the density is higher when glass powder is 20 %. According to the findings on mechanical properties, clay brick samples with higher plastic powder content 20 % displayed a decrease in compressive strength and flexural bending strength, i. e. the mechanical properties (compressive and flexural strengths) are increased with the increased","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"248 - 259"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45182697","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Urban Constructed Wetlands in Arid and Semiarid Zones 干旱半干旱区城市人工湿地研究
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0033
Maryam Lachinani Kordesofla, Parisa Abna
{"title":"Urban Constructed Wetlands in Arid and Semiarid Zones","authors":"Maryam Lachinani Kordesofla, Parisa Abna","doi":"10.2478/cee-2023-0033","DOIUrl":"https://doi.org/10.2478/cee-2023-0033","url":null,"abstract":"Abstract The development of societies and the increasing growth of recent constructions, especially in cities, have caused environmental issues, destruction, and reduction of natural resources and the environment, especially green and green-blue spaces. According to studies, in the past years, many parts of natural and even pristine surfaces and spaces in big cities have been turned into artificial, and impermeable spaces, which has aggravated environmental and ecological problems and also it has aggravated the aesthetic characteristics of the urban landscape, particularly in arid and semiarid areas. In this case, the studies show that identifying and applying natural ecosystems such as wetlands and their artificial types due to their multifunctional aspects and benefits, especially in urban areas, can be the basis for reducing many issues mentioned. Therefore, it is necessary to pay attention to this critical issue and do more research to know different types of constructed wetland ecosystems along with their services and values. The primary aim of this research is to identify the values and services of this ecosystem and to examine the diverse patterns of constructed wetlands in order to extract and design simple patterns of construcred wetlands. We want to know their role and position in landscape architecture and urban planning and design process. Also, this study aims to examine the potencial and possibillity of building constructed wetlands in urban areas particularly in arid areas and Mediterranean regions, according to Koppen climate classiffication. In this regard, the theoretical framework is provided based on the study of specialized texts and the study of similar foreign case studies and diverse patterns of urban wetlands with their different functions. These reviews have been done in a specific format consisting of some main aspects, such as the function and supply sources of wetlands. The final result and extractted simplified patterns, according to case studies, can be considered as a framework for designing and planning urban constructed wetlands and a guide for planning and designing a landscape consisting of this element, especially in areas with arid, semiarid, and Mediterranean climates with hot and dry summers.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"364 - 379"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42309429","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Structural Behaviour of Voided Flat Slab With Various Void Ratios Under Vertical Loading 不同孔隙比的空心平板在竖向荷载作用下的结构性能
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0027
L. Lakshmi Kanth, P. Poluraju
{"title":"Structural Behaviour of Voided Flat Slab With Various Void Ratios Under Vertical Loading","authors":"L. Lakshmi Kanth, P. Poluraju","doi":"10.2478/cee-2023-0027","DOIUrl":"https://doi.org/10.2478/cee-2023-0027","url":null,"abstract":"Abstract In recent modern buildings, voided slabs have been implemented because of the high reduction of their weight up to 35 %. Also, CO2 emission takes place which was developed from mass concrete. Due to percentage reduction of concrete, it leads to help the pollution free environment, eco-friendly and also more sustainable. On voided flat slabs, a minimal study has been recorded. In this current study, an approach has been made to study the effect of the position of voids in the voided flat slabs. Two groups of seven specimens each, one slab in each group was a controlled flat slab specimen with zero number of voids kept as a reference specimen, while the others were voided slabs. In each group, the number of voids were used based on the positions. The designation of the specimens is made depending on the number of voids placed and the diameter of the rebar used in the specimens. Group-A was reinforced with 8 mm diameter rebars, and Group-B was reinforced with 6 mm diameter rebars. The parameters of the study are the void positions and the rebar diameter. The specimens were subjected to a gradually concentrated load through the short column up to failure. The load carrying capacity of both voided and controlled flat slabs tested have almost same. It indicates that, the inactive concrete below the neutral axis where high density polyethylene (HDPE) recycled hollow spheres have been provided in the flat slab has shown no impact on load carrying capacity of the test specimens. However, the presence of the punching shear can be seen in the specimens where the voids are positioned near the columns and supports. Besides, ABAQUS program (A finite element based software) was used to perform the finite element analysis for profoundly illustrating the experimental findings and performing a parametric study. It is concluded that the concrete has no role at below the neutral axis of structural voided flat slab cross-section for all specimens including controlled specimens (0VS6, 0VS8). Also, it is noticed that the finite element analysis obtained results have shown more or less same as experimental results. From the present study, it is evident that behaviour of voided flat slabs are different from simply supported voided flat slabs.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"301 - 317"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44871828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analytical Study of Buckling Restrained Braced Frames in Different Seismic Zone Using ETABS 基于ETABS的不同震区约束支撑框架屈曲分析研究
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0038
Aparna Shiny Gottem, N. Lingeshwaran, Y. Himath Kumar, Ch. Mallika Chowdary, S. Pratheba, K. Perumal
{"title":"Analytical Study of Buckling Restrained Braced Frames in Different Seismic Zone Using ETABS","authors":"Aparna Shiny Gottem, N. Lingeshwaran, Y. Himath Kumar, Ch. Mallika Chowdary, S. Pratheba, K. Perumal","doi":"10.2478/cee-2023-0038","DOIUrl":"https://doi.org/10.2478/cee-2023-0038","url":null,"abstract":"Abstract Tall buildings have unique seismic challenges, particularly the P-delta effect. This can cause an increase in loads on certain parts of the structure, leading to potential instability or collapse. The solution is to use buckling restrained bracing (BRB) systems, which improve the lateral strength of the structure and control the P-delta effect. The present study aimed to determine the effectiveness of various brace configurations in reducing the seismic response of a 50-story reinforced concrete structure, with a focus on P-delta effects. To achieve this, linear dynamic analysis (response spectrum analysis) was conducted using E-TAB software. The selection of bracing configuration, however, depends upon the seismic zone. For this reason, five distinct configurations (X-pattern, inverted V, forward inclined, zig-zag, and bare frame) are considered for the analysis of buildings in different seismic zones. A building model was employed to study the behaviour of a structure with and without BRB to compare the parameters of storey drift, story displacement, diaphragm drift, story shear, story stiffness, and story acceleration using E-TAB software. Results showed that both Type-4 and Type-2 braces perform similarly in several aspects in seismic zones III and V. However, Type-2 braces perform slightly better in terms of storey stiffness-Y, with a lower difference of 39-40 % compared to Type-4 braces with a difference of 49 %.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"426 - 443"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47950906","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Beginning of Participatory Urbanism and the Sustainable City: Case of Rabat, Morocco 参与式城市主义的开端与可持续城市——以摩洛哥拉巴特为例
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0021
Soraya Elhamdouni, E. Cherkaoui, A. Nounah, M. Khamar
{"title":"Beginning of Participatory Urbanism and the Sustainable City: Case of Rabat, Morocco","authors":"Soraya Elhamdouni, E. Cherkaoui, A. Nounah, M. Khamar","doi":"10.2478/cee-2023-0021","DOIUrl":"https://doi.org/10.2478/cee-2023-0021","url":null,"abstract":"Abstract Since its independence, Morocco suffered from many economic, social, environmental, and urban challenges. To deal with the existing dysfunctions, the State will look towards creating structuring projects, laws, national programs, etc. Except that all, the measures taken to remedy this do not integrate the population. The objective of this study is the participatory approach concretization in the process of sustainable development through a questionnaire targeting the resident population and the daily citizens in Rabat. As a result, various dysfunctions affecting mobility, pollution, and the living environment in general in Rabat were highlighted. These results will be the subject of a roadmap for an integrated and inclusive sustainable development project in a safe environment.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"234 - 247"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47315923","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Shear and Flexural Behavior of Lightweight Concrete Beams Containing Hybrid Fibers 混杂纤维轻量混凝土梁的抗剪和抗弯性能
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0018
Noora H. A. Al-Khafaji, Ibrahim S. I. Harba
{"title":"Shear and Flexural Behavior of Lightweight Concrete Beams Containing Hybrid Fibers","authors":"Noora H. A. Al-Khafaji, Ibrahim S. I. Harba","doi":"10.2478/cee-2023-0018","DOIUrl":"https://doi.org/10.2478/cee-2023-0018","url":null,"abstract":"Abstract Due to the low density of lightweight concrete, work has been done in this research to develop it by adding fibers of more than one type to improve its properties. Basic tests were conducted to determine the properties of concrete before and after the addition of fibers. The variables of the models were beams in two groups (shear and flexural). The variables of these two groups included the type of fibers (steel and polypropylene) and the size of the added fibers 0 %, 0.05 %, 0.1 % for polypropylene fibers 0 %, 0.75 %, 1 % for steel fibers. This study presented an examination of 18 beam specimens and discussed the results, which included mechanical properties (air dry density, slump test, compressive strength, modulus of elasticity, flexural strength, and splitting tensile strength). The results showed that the addition of fibers had an effective effect on the compressive strength, and this led to an increase in the resistance to shear forces and flexural forces, as the highest load capacity was shown by adding polypropylene fibers at a rate of 0.1 % in both groups, and the fibers played an important role in reducing the width of cracks and controlling their spread due to modulus of elasticity of the fiber.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"206 - 217"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45973582","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analysis of Road Traffic Accidents Among Iraqi Governorates 伊拉克各省道路交通事故分析
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0012
Roaa Hamed Latief, Rana Ismael Khaleel Zaki, Amjad Hamad Albayati
{"title":"Analysis of Road Traffic Accidents Among Iraqi Governorates","authors":"Roaa Hamed Latief, Rana Ismael Khaleel Zaki, Amjad Hamad Albayati","doi":"10.2478/cee-2023-0012","DOIUrl":"https://doi.org/10.2478/cee-2023-0012","url":null,"abstract":"Abstract Road accidents have been identified as one of the main causes of death and have a significant effect on public health challenges, economic growth and development. The Iraqi transport infrastructure has suffered from the effects of war, carelessness, and lack of investment. As a result, road traffic accidents have increased, and the current efforts to address road safety are minimal in comparison to the growing level of citizen suffering. The objective of this study was to provincially analyze traffic accidents in Iraq using data from 2010 to 2020 to shed light on the current situation. Three key conclusions were made from the results: first, people aged 35 years and under was the age group recorded in the most traffic accidents; second, Al-Najaf province recorded the highest rate of traffic accidents; and third, COVID-19 lockdown in Iraq caused a 28.5 % decline in traffic accidents while fatality and injury rates fell by 28 % and 18.4 % respectively, when comparing with the data of the same period in 2019.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"134 - 148"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48611670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Effect of Rotation Rate Parameter on Two Circular Cylinders in Steady and Unsteady Regimes at Different Reynolds Numbers 转速参数对两圆柱在不同雷诺数下定常和非定常状态的影响
IF 1.2
Civil and Environmental Engineering Pub Date : 2023-05-12 DOI: 10.2478/cee-2023-0035
M. Essahraoui, R. El Bouayadi, A. Saad
{"title":"The Effect of Rotation Rate Parameter on Two Circular Cylinders in Steady and Unsteady Regimes at Different Reynolds Numbers","authors":"M. Essahraoui, R. El Bouayadi, A. Saad","doi":"10.2478/cee-2023-0035","DOIUrl":"https://doi.org/10.2478/cee-2023-0035","url":null,"abstract":"Abstract The effect of rotation rate parameter, cylinder diameter, and the variation of Reynolds number on the circular cylinder was the main object of this 2D numerical study. Rotating and stationary circular cylinder in steady and unsteady incompressible flow has been analysed. For each value of Reynolds number, we have varied the rotation rate parameter clockwise and anti-clockwise to visualize their effect on the drag, lift, and coefficients. All cases have carried out steady laminar, unsteady laminar, and turbulent regimes. A realizable K-epsilon model has been used to solve the Navier Stokes equations for the turbulent regime. Results were in good agreement with the recent findings.","PeriodicalId":42034,"journal":{"name":"Civil and Environmental Engineering","volume":"19 1","pages":"391 - 405"},"PeriodicalIF":1.2,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48269046","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信