{"title":"Restoring a TWSTFT calibration with a GPS bridge - A standard procedure for UTC time transfer","authors":"Z. Jiang, Dirk Piester, K. Liang","doi":"10.1109/EFTF.2010.6533693","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533693","url":null,"abstract":"Two-Way Satellite Time and Frequency Transfer (TW for short) is one of the primary techniques for UTC (Coordinated Universal Time) time transfer. One of its advantages is its ability of accurate calibration, reflected by its low achievable Type B uncertainty, uB(TW). Of the time links included in the calculation of UTC, the best uB(TW) is about 1 ns, as compared to 5 ns for uB(GPS). Moreover, the TW calibration is characterized by long-term stability and reproducibility within the stated calibration uncertainty. However TW calibration is rather expensive and time consuming. It also depends on the complete configuration of the triangle Lab(1)-satellite-Lab(2). Any change in any of the segments necessitates a change in the calibration. Such a situation has occurred several times over the last years, due to exchanges of the used satellites. After changes, a calibration can be restored by means of a bridge based on another, continued, time-transfer technique. In this paper, we discuss the restoration of TW calibrations using GPS PPP and other bridges, and estimate their uncertainties. A standard procedure has been developed for the restoration operation. This procedure was use d to restore TW calibrations following the change in satellite from IS-3R to T-11N in mid-2009, and the results were implemented in the TW links as of September 2009.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"158 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133159803","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Improvement of TWSTFT short-term stability utilizing full time transfer network data","authors":"H. T. Lin, C. Liao, F. Chu, Wen-Hung Tseng","doi":"10.1109/EFTF.2010.6533691","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533691","url":null,"abstract":"In the Asia-Pacific Rim region, the two-way satellite time and frequency transfer (TWSTFT) links between 6 Labs, using multi-channel time transfer modems, have composed a time-transfer network. To fully utilize the data of TWSTFT network and improve the short-term stability of TWSTFT, a feasible method of processing data is proposed. We perform data analysis with practical time transfer data, and the results show that it is an effective method to improve the TWSTFT short-term stability.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132443670","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Measurement of Cs-buffer gas collisional frequency shift using pulsed CPT interrogation","authors":"O. Kozlova, R. Boudot, S. Guérandel, E. de Clercq","doi":"10.1109/EFTF.2010.6533684","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533684","url":null,"abstract":"In this paper we presented separate measurements of the temperature coefficients for clock transition in Cs for N2, Ar and Ne buffer gases. The inversion temperature for Ne has been determined (77°C). For N2 the inversion temperature is estimated at 157 158°C. We have reduced the uncertainties for linear temperature coefficients for Cs clock transition three buffer gases. The quadratic coefficients γ for N2 and Ne have been determined for the first time. For Ar buffer gas, the quadratic coefficient γ is much smaller and we have estimated its upper limit.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"62 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133091794","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
B. Leger, L. Stringhetti, D. Massonnet, C. Delaroche, F. Picard, M. Hess, L. Cacciapuoti, S. Feltham, R. Much, R. Nasca, T. Vudali, C. Salomon, P. Laurent
{"title":"Results of the ACES engineering model system test","authors":"B. Leger, L. Stringhetti, D. Massonnet, C. Delaroche, F. Picard, M. Hess, L. Cacciapuoti, S. Feltham, R. Much, R. Nasca, T. Vudali, C. Salomon, P. Laurent","doi":"10.1109/EFTF.2010.6533731","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533731","url":null,"abstract":"Atomic Clock Ensemble in Space (ACES) is a European Space Agency (ESA) project to be deployed externally to the Columbus Laboratory on the International Space Station (ISS). Two high performance atomic clocks on-board ACES generate a frequency reference with stability and accuracy at the 1×10-16 level. The performance of the ACES clock signal results from the combination of the good short-term stability of an active hydrogen maser (SHM) and the long-term stability and accuracy of a primary standard based on samples of laser cooled Cs atoms (PHARAO). The two clocks are controlled by two servo loops, the first stabilizing the PHARAO local oscillator on SHM clock signal, the second correcting the long-term instabilities of SHM using the error signal generated by the PHARAO Cs resonator. This frequency reference, distributed to the ground by a link in the microwave domain is used to perform comparisons of distant clocks and to test Einstein's theory of general relativity. ACES main instrument and subsystems have now reached a high technology readiness level, demonstrated by the completion and the successful test of their engineering models. In particular, a dedicated test campaign has recently verified the performance of the ACES system, where PHARAO and SHM, locked together via the ACES servo loops, are operated as a unique oscillator to generate the ACES frequency reference. The test campaign conducted at CNES premises in Toulouse between July and November 2009 has concluded the engineering models phase, releasing the manufacturing of the ACES flight models. The setup of the ACES system test campaign, the specific tests performed, and the achieved results will be presented and discussed.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121779550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Droit, J. Friedt, G. Martin, J. Masson, S. Ballandras
{"title":"An algorithm for automating fast and accurate measurements of the resonance frequencies of SAW sensors","authors":"C. Droit, J. Friedt, G. Martin, J. Masson, S. Ballandras","doi":"10.1109/EFTF.2010.6533713","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533713","url":null,"abstract":"Within the context of probing acoustic wave resonators acting as wireless, passive sensors, we present an embedded interrogation unit and the associated algorithms, demonstrating the flexibility of a mostly software defined strategy. An ARM-7 based central processing unit synchronizes the narrow-band probing pulse emission, emission-to-reception switching, data sampling and data processing. Since each emitted pulse is independently defined with respect to its neighbours, flexible strategies are implemented aiming at fast (3 points needed to probe the resonant frequency, with a total duration less than 200 μs) and accurate (≃10 Hz resolution) techniques.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130307525","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dark resonance in wall-coated cell for Rb clocks","authors":"E. Breschi, G. Mileti","doi":"10.1109/EFTF.2010.6533677","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533677","url":null,"abstract":"This work aims at evaluating the potential of anti-spin-relaxation wall-coated cells for the development of an atomic clock based on coherent population trapping effect. We measure stability of 3·10<sup>-12</sup> at 1 s and of about 1·10<sup>-11</sup> at 10<sup>4</sup> s. These values seem limited by the detection noise level and the frequency drift induced by the coating, respectively.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130310791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dual-mode quartz resonators suitable for TCXO and OCXO","authors":"A. Kosykh, I. Khomenko, A. Lepetaev","doi":"10.1109/EFTF.2010.6533670","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533670","url":null,"abstract":"One of the reasons of TCXO and OCXO thermal frequency instability is existence of thermal gradient between resonator and temperature sensor. Piezoelectric crystal plate and thermo sensor companioning is very difficult technical problem because sensor must be placed in resonator area where amplitude of oscillation is maximal. Only in this case we will have properly information about \"own mode\" temperature. Unfortunately placing of any external sensor at this surface area will lead to dramatically Q factor worsening and practically unexercised. Some years ago the \"self temperature sensing\" technology based on dual mode excitation using were proposed. This technology have in mind using of simultaneous excitation of \"B\" and \"C\" modes or 1 st and 3 rd mechanical harmonic in SC cut resonators. The second method have low temperature sensitivity and the first method have great one, but disadvantage because in majority of realization it may be obtained as called \"activity dips\" oscillation decay at specific temperatures. It is shown that the reason of B mode activity dip is acoustic interaction of B mode with C mode inharmonic. The algebraic expression describes this phenomenon are shown. The numerically analytical method of dual mode resonator modeling is described. This method allows obtain modes parameters (motional resistance, modes frequencies, thermal time constants) as a function of plate sizes, electrode sizes and plate curvature.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129652567","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Towards an optical lattice clock based on mercury: Loading of a dipole trap","authors":"S. Mejri, J. McFerran, L. Yi, S. Bize","doi":"10.1109/EFTF.2010.6533642","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533642","url":null,"abstract":"In the pursuit of developing an optical lattice clock with mercury as the quantum absorber, we describe an experiment that produces dipole lattice trapping of neutral mercury atoms. We report on the details of an optical lattice trap with light near the predicted magic wavelength and on the implementation of a low noise detection system.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130800974","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Miletic, C. Affolderbach, E. Breschi, C. Schori, G. Mileti, M. Hasegawa, R. Chutani, P. Dziuban, R. Boudot, V. Giordano, C. Gorecki
{"title":"Fabrication and spectroscopy of Cs vapor cells with buffer gas for miniature atomic clock","authors":"D. Miletic, C. Affolderbach, E. Breschi, C. Schori, G. Mileti, M. Hasegawa, R. Chutani, P. Dziuban, R. Boudot, V. Giordano, C. Gorecki","doi":"10.1109/EFTF.2010.6533678","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533678","url":null,"abstract":"In this communication we discuss the fabrication and spectroscopic characterization of original micro-fabricated Cs cells filled with buffer gas in view of applications in miniature atomic clocks. The influence of several experimental parameters on CPT resonances in such micro cells is studied. We observed a quadratic temperature dependence of the clock frequency in a micro-fabricated cell filled with Cs and pure Ne buffer gas. This results in a low temperature coefficient around the inversion temperature, and relaxes the stability requirements on the cell temperature and should improve the clock's long term stability. The possibility to achieve such low temperature coefficient using a single type of buffer gas can noticeably simplify the technique of the cell production. Indeed, the control of the buffer-gas represents a difficult challenge in micro-fabricated cells production. Finally we report on preliminary short term clock stability measurements. A stability of 5x10-10 τ-1/2 @ 1s is obtained. This value is in good agreement with the signal-tonoise stability prediction but remains to be improved.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122132877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Advances in the development of an Extra Small Atomic Reference (XSAR)","authors":"J. Haesler, J. Bennes, S. Lecomte","doi":"10.1109/EFTF.2010.6533687","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533687","url":null,"abstract":"This paper describes a one year work started at CSEM in 2009. At the end of the project, a system level prototype of an Extra Small Atomic Reference (XSAR) should be realized by teaming up different know-hows available at CSEM. The work followed a top down systematic. A breadboard level coherent population trapping (CPT) atomic clock working on Rubidium-87 atoms confined in a glass cell and controlled by laboratory electronics was built at first. The different building blocks of this breadboard CPT atomic clock were characterized in order to select them for the XSAR prototype. The CPT signal and the corresponding operating parameters were accordingly optimized. The knowledge acquired in the first phase was used to define the goals to be re ached with the first XSAR prototype. Priorities were settled on the miniaturization of the optical assembly unit (laser and optics), the atomic vapor cell unit and finally the RF electronic unit. After one year, the first XSAR prototype showed promising short term frequency stability reaching 1.8·10-11τ-1/2 when fully driven by laboratory RF electronics and 2·10-10τ-1/2 when driven by an integrated RF synthesizer.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116669996","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}