EFTF-2010 24th European Frequency and Time Forum最新文献

筛选
英文 中文
Ongoing improvements of the time and frequency references at LNE-syrte 正在进行的时间和频率参考的改进
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533661
M. Abgrall, P. Ullrich, D. Valat
{"title":"Ongoing improvements of the time and frequency references at LNE-syrte","authors":"M. Abgrall, P. Ullrich, D. Valat","doi":"10.1109/EFTF.2010.6533661","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533661","url":null,"abstract":"We present the current developments performed at LNE-SYRTE, to produce a new time reference, called UTC(OP)_Maser. This time reference aims at taking benefits of our clock ensemble: the short term stability of a hydrogen maser, the mid term stability of our ensemble of industrial cesium clocks, and the accuracy of our three cold atom fountains. This paper describes an algorithm that produces a timescale optimised in terms of stability over averaging periods of 1-2 months, with a weighted average of the cesium clocks data. We also present the steering processes, involving the fountain calibrations, to drive the timescale towards UTC, and to control the hydrogen maser. The simulations, based on past data, show an improvement of a factor of 5, in terms of time accuracy, compared to the current UTC(OP). The first experimental results demonstrate a gain of more than one order of magnitude on the short term stability.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122390543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Development of the Space active Hydrogen Maser for the ACES Mission ACES任务中空间活性氢脉泽的研制
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533730
D. Goujon, P. Rochat, P. Mosset, D. Boving, A. Perri, J. Rochat, N. Ramanan, D. Simonet, X. Vernez, S. Froidevaux, G. Perruchoud
{"title":"Development of the Space active Hydrogen Maser for the ACES Mission","authors":"D. Goujon, P. Rochat, P. Mosset, D. Boving, A. Perri, J. Rochat, N. Ramanan, D. Simonet, X. Vernez, S. Froidevaux, G. Perruchoud","doi":"10.1109/EFTF.2010.6533730","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533730","url":null,"abstract":"The Atomic Clock Ensemble in Space (ACES) is composed of two atomic clocks: one cold Caesium clock (PHARAO) and one active Space Hydrogen Maser (SHM). PHARAO is necessary to ensure outstanding long-term frequency stability (τ ≥ 3000 s) and accuracy, while SHM is mandatory for its ultimate frequency stability in the mid-term range (3 s ≤ τ ≤ 3000 s). The combination of the two clocks via a double servo loop (short-term and long-term), will ensure an ultimate frequency stability. This configuration takes advantage of the best frequency stability for each integration time (PHARAO frequency locked to SHM for the short and mid-term, and SHM frequency steered to PHARAO for the long-term).","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123305454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
Demonstration of a cryocooled 10 GHz oscillator with 10−15 frequency stability 具有10 - 15频率稳定性的冷冻10ghz振荡器的演示
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533698
S. Grop, P. Bourgeois, N. Bazin, Y. Kersalé, E. Rubiola, C. Langham, M. Oxborrow, D. Clapton, S. Walker, J. De Vicente, V. Giordano
{"title":"Demonstration of a cryocooled 10 GHz oscillator with 10−15 frequency stability","authors":"S. Grop, P. Bourgeois, N. Bazin, Y. Kersalé, E. Rubiola, C. Langham, M. Oxborrow, D. Clapton, S. Walker, J. De Vicente, V. Giordano","doi":"10.1109/EFTF.2010.6533698","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533698","url":null,"abstract":"This paper reports the breadboarding and the validation of a 10 GHz ultra-stable Cryogenic Sapphire Oscillator (CSO) operated in an autonomous cryocooler. This CSO presents a frequency stability better than 3 × 10-15 between 1 s and 1,000 s and a phase noise lower than -100 dBc/Hz at 1 Hz.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125480828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of passive hydrogen maser in Shanghai Astronomical Observatory 上海天文台被动氢脉泽的研制
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533679
Xie Yonghui, Dai Jiayua, Chen Wenxing, Liu Tiexin, Zhang Yong, Pen Jixing, Lin Chuanfu
{"title":"Development of passive hydrogen maser in Shanghai Astronomical Observatory","authors":"Xie Yonghui, Dai Jiayua, Chen Wenxing, Liu Tiexin, Zhang Yong, Pen Jixing, Lin Chuanfu","doi":"10.1109/EFTF.2010.6533679","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533679","url":null,"abstract":"Study of passive hydrogen maser in Shanghai Astronomical Observatory is introduced. New type of passive hydrogen maser with high performance has been developed. It has unique features such as novel kind of electrode cavity with high Q factor (loaded-cavity Q factor up to 10000) and new frequency control scheme of electronics package, with the help of novel cavity-bulb assembly, quadrupole state selector, nickel purifier, new dissociator and four layer magnetic shield, the atomic signal gain of physics package is up to 3dB at -80dBm microwave signal input. Several passive hydrogen maser prototypes have been developed. Preliminary performance test yields the frequency stability better than 1×10-12τ-1/2(1s≤τ≤10000s) and 1×10-14 @1day.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"450 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125806386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Pulsed optically pumped Rb clock with optical detection: First results 具有光学检测的脉冲光泵浦Rb时钟:第一个结果
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533681
S. Micalizio, A. Godone, F. Levi, C. Calosso, F. Gruet, M. Pellaton, T. Bandi, C. Affolderbach, G. Mileti
{"title":"Pulsed optically pumped Rb clock with optical detection: First results","authors":"S. Micalizio, A. Godone, F. Levi, C. Calosso, F. Gruet, M. Pellaton, T. Bandi, C. Affolderbach, G. Mileti","doi":"10.1109/EFTF.2010.6533681","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533681","url":null,"abstract":"In this work we present the first results related to a prototype of Rb clock working in pulsed regime, developed in the frame of an ESA contract (“Next generation compact atomic clocks”, 21504/08/NL/GLC). The contract is a joint participation between Istituto Nazionale di Ricerca Metrologica, Optics Division (INRIM, Italy) and Université de Neuchatel, Laboratoire Temps - Frequence (LTF, Switzerland).","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"254 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132120833","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Fabrication of a 3 GHz oscillator based on nano-carbon-diamond-film-based guided wave resonators 基于纳米碳-金刚石膜导波谐振器的3ghz振荡器的制备
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533657
R. Salut, C. Gesset, G. Martin, S. Saada, B. Assouar, P. Bergonzo, R. Boudot, F. Bénédic, O. Elmazria, F. Omnes, D. Remiens, S. Ballandras
{"title":"Fabrication of a 3 GHz oscillator based on nano-carbon-diamond-film-based guided wave resonators","authors":"R. Salut, C. Gesset, G. Martin, S. Saada, B. Assouar, P. Bergonzo, R. Boudot, F. Bénédic, O. Elmazria, F. Omnes, D. Remiens, S. Ballandras","doi":"10.1109/EFTF.2010.6533657","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533657","url":null,"abstract":"In this work, we have developed high frequency resonators for frequency source applications. These resonators were built using E-beam lithography on ZnO/NCD/Si substrate, exploiting the nucleation side of the NCD to allow for a reliable and reproducible lithography step. NCD films and substrates have also been used to minimize the acoustic losses due to large grain overlays favoring acoustic diffusion along the surface propagation. Single and double port resonators have been built in the 3-6 GHz frequency range. Double port resonators have revealed compatible with the oscillator application, yielding a first oscillator demonstration near 3 GHz. Considering the operation condition of this oscillator, one should improve the corresponding stability characteristics without too much efforts, simply developing an adapted packaging of the resonator and a robust low noise amplifier loop.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132121135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Multi-channel real-time computation of ADEV and TDEV 多通道实时计算ADEV和TDEV
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533708
M. Kasznia
{"title":"Multi-channel real-time computation of ADEV and TDEV","authors":"M. Kasznia","doi":"10.1109/EFTF.2010.6533708","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533708","url":null,"abstract":"In this paper the methods of multi-channel real-time computation of ADEV and TDEV are proposed. These methods are developed for a multi-channel measuring system, where the time error counter and the computer controlling the measurement are two separate units. In order to calculate the parameters simultaneously for several channels and several observation intervals in the real time, all necessary operations should be performed in the time period between two sampling instants. Multichannel real-time computation requires the same rearrangement of estimators' formulae, as for single-channel real-time computation. However, multichannel computation requires a special organization of the process because of multiple data streams received from several time error meters (measurement channels). In the paper the results of experimental tests of the methods proposed for different conditions are presented. The calculations were performed for the time error samples taken with sampling interval τ0=1/30 s, which is often used in the telecommunication applications. Different numbers, lengths, and ranges of the observation intervals simultaneously analyzed were considered. The results of calculation performed for data obtained from up to 4 channels using different computers are presented and compared. Two data organization methods, with separate data structures (one for each channel) and joint data structure, were considered and compared.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114387432","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Progress on passive H-maser for Compass system 罗盘系统被动h脉泽研制进展
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533685
Ren-fu Yang, Jing Li, Hai-bo Chen, Jihong Zhang, Lian-shan Gao
{"title":"Progress on passive H-maser for Compass system","authors":"Ren-fu Yang, Jing Li, Hai-bo Chen, Jihong Zhang, Lian-shan Gao","doi":"10.1109/EFTF.2010.6533685","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533685","url":null,"abstract":"The Rubidium atomic frequency standard is at present the basic clock technology for the Chinese Compass Navigation payload. What's more, hydrogen atomic clock will become another critical satellite equipment for the navigation system. In this work, the authors report the latest progress in a space borne passive hydrogen maser for Chinese Compass satellites. The preliminary measurement result of long-term frequency stability in our passive H-maser on ground is 2E-14 over averaging time of ten thousand seconds.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115319120","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Precise determination of the refractive index of air in Fabry-Perot cavity by means of the optical frequency comb 用光学频率梳精确测定法布里-珀罗腔内空气的折射率
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533721
R. Smíd, O. Cíp, B. Mikel, Z. Buchta, M. Čížek, J. Lazar
{"title":"Precise determination of the refractive index of air in Fabry-Perot cavity by means of the optical frequency comb","authors":"R. Smíd, O. Cíp, B. Mikel, Z. Buchta, M. Čížek, J. Lazar","doi":"10.1109/EFTF.2010.6533721","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533721","url":null,"abstract":"We experimentally demonstrated a method for monitoring of cavity length changes based on femtosecond laser comb. Our pilot experiment based on separation of frequency comb lines by fiber Bragg grating produces an unlimited variety of Fabry-Perot cavity lengths to be locked on. We experimentally demonstrated that the Fabry-Perot cavity length could be locked to one chosen femtosecond frequency comb line. Tracking the optical path distance of FPC to optical component of frequency comb can be directly measured by means of counter of repetition frequency.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122252829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
New investigations on the LGT crystal intended for time and frequency applications 用于时频应用的LGT晶体的新研究
EFTF-2010 24th European Frequency and Time Forum Pub Date : 2010-04-13 DOI: 10.1109/EFTF.2010.6533636
J. Boy, N. Nguyen Thi Kim, S. Devautour-Vinot, J. Frayret
{"title":"New investigations on the LGT crystal intended for time and frequency applications","authors":"J. Boy, N. Nguyen Thi Kim, S. Devautour-Vinot, J. Frayret","doi":"10.1109/EFTF.2010.6533636","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533636","url":null,"abstract":"Materials of the langasite family are of current interest for both Bulk Acoustic Wave and Surface Acoustic Wave devices. In particular, they could be promising solutions to Frequency and Time applications due to their g/product, two to three times higher than for the quartz crystal . We have shown that this encouraging result is strongly linked to the crystal quality and to the post thermal treatment which has been submitted the device. Among the numerous crystals belonging to the LGS family, LGT seems more interesting because of the best combination of quality of growth and material parameters. To qualify the LGT crystal, We have investigated different samples by means Of the infrared spectrometry (IR), the dielectric relaxation spectroscopy (DRS) and the inductively coupled plasma-mass spectrometry (ICP-MS), this last one dealing with the nature and the amount of the chemical impurities. Furthermore, we have investigated the inhomogeneity of our samples coming from different suppliers by measuring their optical rotary power and theIr coefficients Of gyration α at different wavelength.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"55 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123806462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书