M. Stumpf, S. Pekarek, A. Oehler, T. Sudmeyer, J. Dudley, S. Schilt, G. Di Domenico, P. Thomann, U. Keller
{"title":"First fully stabilized frequency comb from a SESAM-modelocked 1.5-µm solid-state oscillator","authors":"M. Stumpf, S. Pekarek, A. Oehler, T. Sudmeyer, J. Dudley, S. Schilt, G. Di Domenico, P. Thomann, U. Keller","doi":"10.1109/EFTF.2010.6533705","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533705","url":null,"abstract":"In conclusion, we have demonstrated the first fully stabilized frequency comb generated by an ultrafast Er:Vb:glass laser. The SESAM-modelocked, diode-pumped laser uses a high-Q cavity which results in low-noise operation. A coherent, octave-spanning SC is generated by nonlinear spectral broadening in a polarization maintaining highlynonlinear fiber. We observe a more than 10-times improvement in the free-running CEO frequency linewidth compared to free-running femtosecond fiber laser systems operating in this spectral region. The CEO frequency and the repetition rate are stabilized to the same 10-MHz external reference over hours. The Allan deviation of the 20-MHz CEO reaches 10-8 at 1-s with an H-maser as an external reference and a stable locked operation of more than 11 hours was achieved in a preliminary long-term evaluation. A CEO-beat signal can still be observed at a large reduction of the pump power, resulting in a reduced intracavity pulse energy and in an increased pulse duration up to 260 fs. We expect that this result will have a significant impact for the future development of more compact stable frequency combs as the relatively long pulse duration relaxes the requirements on the modelocked laser. This will become even more important for gigahertz pulse repetition rates.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133234001","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Requirements on GNSS receivers from the perspective of timing applications","authors":"P. Defraigne, G. Petit, P. Uhrich, W. Aerts","doi":"10.1109/EFTF.2010.6533724","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533724","url":null,"abstract":"This paper reviews the requirements on GNSS receiver setups for precise time and frequency transfer; these concern the receiver itself, the GNSS measurements, the antenna and cables used in the full setup. Concerning the receiver, we show that for a high level scientific use of a GNSS receiver within the frame of timing applications, it is essential that certain time delay related parameters be described in detail by the manufacturer.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115124783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Cross correlation residual phase noise measurements using two HP3048A systems and a PC based dual channel FFT spectrum analyser","authors":"S. Bale, D. Adamson, B. Wakley, J. Everard","doi":"10.1109/EFTF.2010.6533700","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533700","url":null,"abstract":"This paper describes a cross correlation residual phase noise measurement system based on two HP3048A systems and a dual channel FFT spectrum analyser consisting of a PC card containing two 16bit (125MS/Sec) A to D converters. A measurement system noise floor of -200 dBc/Hz is achieved for 100,000 correlations. Residual phase noise measurements are also performed on low noise L-Band microwave amplifiers, developed at York. The key features of the cross correlation technique and the different window functions required during measurement are discussed.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121047224","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Absolute calibration and evaluation of geodetic receivers","authors":"A. Proia, G. Cibiel, L. Yaigre","doi":"10.1109/EFTF.2010.6533667","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533667","url":null,"abstract":"The artificial reception method which uses a GNSS signal simulator is now a proofed method. It lets to determine the electrical delay of the most of geodetic receivers used in time laboratories: Ashtech Z12 T, Septentrio PolaRx2 and Dicom GTR50 with an uncertainty of about 0.4 ns.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126939005","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Topology dependence of mass sensitivities in mode-localized sensors","authors":"P. Thiruvenkatanathan, J. Yan, A. Seshia","doi":"10.1109/EFTF.2010.6533646","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533646","url":null,"abstract":"Vibration mode localization has been employed as an ultrasensitive approach for mass detection and identification in recent years. Sensitivity enhancements of nearly three orders of magnitude relative to the more conventional resonant frequency shift approach have been experimentally demonstrated using this sensing paradigm, by either exploiting the critical dependence of the parametric sensitivity on the strength of internal coupling or by increasing the number of degrees of freedom by arraying multiple resonators with weak coupling springs. We propose here, for the first time, an additional approach to sensitivity enhancement in such mode-localized mass sensors by utilizing the sensitivity dependence on the operating frequency and the stiffness of the resonator topology. We experimentally demonstrate the sensitivity dependence on the topology, by comparing and contrasting the vibration behaviour of three pairs of electrically coupled microelectromechanical (MEM) resonators of different structural configurations and operating frequencies. The shifts in the eigenstates for the same relative mass additions are experimentally demonstrated to be over three orders of magnitude greater than corresponding resonant frequency shifts. They are also shown to increase proportionally with the square of the resonant frequencies of the coupled resonator platforms (with the stiffer configurations of higher operating frequencies yielding a further one order of magnitude improvement over the more compliant topologies of nearly equal resonator masses). This topology dependence while providing a systematic approach to the design of mode-localized mass sensors within a given design space, also suggests an alternate route to improving the mass sensitivity by designing stiffer topologies with weak coupling instead of the more conventional route of scaling down system dimensions in traditional resonant mass sensors.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116221679","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Salzenstein, A. Kuna, L. Sojdr, B. Cemusova, N. Cholley, F. Lefebvre
{"title":"Resonator frequency stability contribution to the performance of ultrastable oscillators before and after integration","authors":"P. Salzenstein, A. Kuna, L. Sojdr, B. Cemusova, N. Cholley, F. Lefebvre","doi":"10.1109/EFTF.2010.6533673","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533673","url":null,"abstract":"The aim of this article is to present the performances of the instruments developed for the measurement of 5 MHz ultra-stable resonators, before and after being integrated in an oscillator. The chosen resonator has an estimated stability of several 10-14. Intrinsic noise floor of these benches are about 7 to 9.5×10-15.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"236 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124600744","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Gerginov, N. Nemitz, D. Griebsch, M. Kazda, R. Li, K. Gibble, R. Wynands, S. Weyers
{"title":"Recent improvements and current uncertainty budget of PTB fountain clock CSF2","authors":"V. Gerginov, N. Nemitz, D. Griebsch, M. Kazda, R. Li, K. Gibble, R. Wynands, S. Weyers","doi":"10.1109/EFTF.2010.6533639","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533639","url":null,"abstract":"A new source of slow atoms was recently installed on the caesium fountain CSF2 at PTB. This source allows the short-term instability σy(1s) of CSF2 to be reduced from 2.5×10-13 to 1.7×10-13. Because of the reduced atom loading time and the higher number of atoms, the collisional shift uncertainty is no longer the largest term in the uncertainty budget. The uncertainty is now dominated by the uncertainty contribution due to the observed microwave power dependence of the output frequency. Measurements with the CSF1 fountain suggest that the longitudinal cavity phase gradients produce the observed frequency shifts at elevated power. For normal operation related shifts in CSF1 are expected to be much less than 1×10-16. Due to the larger cloud size associated with the optical molasses used for cooling in CSF2, the effects of longitudinal phase gradients will be even further suppressed in CSF2.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127780576","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Salzenstein, K. Volyanskiy, H. Tavernier, M. Pogumerskiy, L. Larger, E. Rubiola
{"title":"Investigation in compact optoelectronic oscillator with mini-disk resonator","authors":"P. Salzenstein, K. Volyanskiy, H. Tavernier, M. Pogumerskiy, L. Larger, E. Rubiola","doi":"10.1109/EFTF.2010.6533638","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533638","url":null,"abstract":"This study deals with a design, fabrication and characterization of compact optoelectronic oscillators (OEO). The resonator - a disk measuring a few millimeters in diameter with rounded edges - behaves as a sphere because the energy is trapped in whispering-gallery modes in the equatorial region. For this purpose, Fused silica and MgF2 are suitable, due to their mechanical characteristics and their low attenuation at 1.55 μm wavelength. In fact, the hardness of 6-7 degrees Mohs of these materials allows us to obtain a quite easy precision processing and surface polishing. Our prototype owns a quality factor of approximately 3×108, which is certainly limited by the available technology. The resonator is coupled to an tapered optical fiber with a few nm position resolution system. The microwave carrier is generated by locking the optical phase modulation to a free spectral range resonator, which occurs in the 10 GHz region. Moreover, this carrier is detected by a standard low-noise InGaAs p-i-n telecom photodiode. The oscillator prototype is assembled on a 0.12 m2 optical breadboard. In principle, this surface can be reduced to those of the oscillator main parts (resonator, laser, photodiode, amplifier and optical modulator). The oscillator phase noise measured by a dual-delay-line instrument, which has been developed in Besancon, corresponds to -90 dBrad2/Hz at 10 kHz off carrier. According to this result, the oscillator suffers from severe noise limitations due to several reasons: the thermal coefficient of the resonator, the low power that the resonator can accept, and the small volume of the energy-confinement region in the resonator (≈2×1014 m3). But our oscillator could be packaged in a small volume, contrarily to a classic OEO based on an optical fiber of a few km.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131934301","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Correction of elastic, piezoelectric and dielectric constants of NdCa40(B03)3 crystal using measured SAW parameters","authors":"E. Brzozowski, W. Soluch","doi":"10.1109/EFTF.2010.6533676","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533676","url":null,"abstract":"For dielectric constants, only ε13 was significantly changed during correction prosess. This is because ε13 is small and have low influence on to capacitance. Mostly changed elastic constants are s12 and s23. Such a big change is due to low accuracy for these constants in resonance-antiresonance method. A mean for other constants change is about 6 %. Mostly changed piezoelectric constants are d31 and d32. Differences between measured and calculated SAW parameters are lower for corrected material constants.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130800421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simulation of the effect of improved ground clocks on GPS timing performance","authors":"M. Suess, D. Matsakis","doi":"10.1109/EFTF.2010.6533703","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533703","url":null,"abstract":"The GPS system is simulated in three scenarios, so as to estimate how its performance would be improved by more stable ground clocks. One scenario is an approximation to the current system. The second replaces the cesium frequency standards at the monitor sites with masers. The third replaces the masers at the two USNO-controlled monitor sites with atomic fountains. The simplifications exaggerate the differences between the scenarios, and the results suggest that the three scenarios are similar in the timing information as delivered to the user for positioning, but that GPS Time could be more stable with improved clocks. Results are tentative, pending more realistic simulations.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131135940","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}