{"title":"Joint real-time computation of Allan deviation, time deviation, and Hadamard deviation","authors":"A. Dobrogowski, M. Kasznia","doi":"10.1109/EFTF.2010.6533709","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533709","url":null,"abstract":"The results of the experimental tests have proved the ability of the real-time computation of Hadamard deviation, Allan deviation, and time deviation performed jointly. The computation of the three parameters can be performed jointly simultaneously for numerous series and wide range of observation intervals as well as rather short sampling interval. Performing jointly the computation of HDEV, ADEV, and TDEV give us additional useful possibilities of timing signal analysis.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"105 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127695279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Interpolation of TW time transfer from measured points onto standard MJD for UTC generation","authors":"Z. Jiang","doi":"10.1109/EFTF.2010.6533722","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533722","url":null,"abstract":"We often need to determine the time transfer result for an epoch at which no direct measurement was made. For example, the time tag used in Circular T is 0 h UTC of the standard MJD, which is not generally a measuring epoch. Usual time transfer practice is to first smooth the raw data to filter out white measurement noise, and then interpolate the smoothed data to determine the time transfer value for the required epoch. However, up until the end of 2009, for two-way (TW) time transfer only simple linear interpolation (but any high-order interpolation method) was used. This was because, when TW was introduced into the computation of UTC in 1998, there were not enough measured points to allow a mathematically rigorous smoothing-interpolation process. Since the end of 2005 the number of measurements has increased to between 12 and 24 per day. To exploit the redundancy of this increased number of data points, in 2005 it was proposed that a higher order smoothing-interpolation method be used. It was concluded that: (1) a high-order smoothing interpolation is better than a simple linear interpolation; and (2) Vondrak smoothing is preferable to other high-order smoothing-interpolation techniques. This paper builds on the previous study, examining the Vondrak smoothing-interpolation method with the benefit of a new powerful tool: the GPS PPP time-transfer solution. This provides an objective measure of the performance of different smoothing-interpolation methods. We conclude that in most cases Vondrak smoothing to the power 105 leads to the best interpolation results.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126601804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Petremand, C. Schori, R. Straessle, G. Mileti, N. D. de Rooij, P. Thomann
{"title":"Low temperature indium-based sealing of microfabricated alkali cells for chip scale atomic clocks","authors":"Y. Petremand, C. Schori, R. Straessle, G. Mileti, N. D. de Rooij, P. Thomann","doi":"10.1109/EFTF.2010.6533683","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533683","url":null,"abstract":"In this paper, the development of a low temperature bonding process focused on indium-based technology for microfabricated alkali cells is presented. The intended application is the use of these cells in chip scale atomic clocks. The existing technology is mainly based on anodic bonding. For some applications, such as where wall coating is used instead of buffer gas, anodic bonding cannot be applied because of the relatively high temperature of the process.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"54 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128002802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"CPT atomic clock based on rubidium 85","authors":"C. Schori, G. Mileti, B. Leuenbeger, P. Rochat","doi":"10.1109/EFTF.2010.6533686","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533686","url":null,"abstract":"We present a compact physics package based on coherent population trapping (CPT) in rubidium 85. The architecture of the package is described along with results obtained using optical- and microwave spectroscopy. We also report the stability of the CPT resonance to variations in operating parameters such as microwave modulation power and vapour cell temperature. With this package we obtain a short term frequency stability σ<sub>y</sub>(τ) = 7·10<sup>-11</sup>·τ<sup>-1/2</sup> (τ <; 100 sec) and σ<sub>y</sub>(τ) ~ 1·10<sup>-11</sup> ( 100 sec <; τ <; 10<sup>4</sup> sec).","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116842482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Results of evaluation of time signals received from NTP servers in Poland","authors":"A. Dobrogowski, M. Jessa, M. Kasznia, K. Lange","doi":"10.1109/EFTF.2010.6533728","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533728","url":null,"abstract":"Summarizing all the series of 24-hours and weekly tests, the authors observed some common tendencies. Neither the server stability nor the speed of generating responses were significantly affected by the fact whether a given test day was a working day or not. It was not confirmed that the server with the shortest time for generating responses is at the same time the most stable one. The influence of the stratum level of the server cannot be noticed, and sometimes a server with better stratum shows worse results. Statistically, the response times of servers are within the range of 100μs.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114308121","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Affolderbach, R. Matthey, F. Gruet, T. Bandi, G. Mileti
{"title":"Realisation of a compact laser-pumped Rubidium frequency standard-12 with < 1×10−12 stability at 1 second","authors":"C. Affolderbach, R. Matthey, F. Gruet, T. Bandi, G. Mileti","doi":"10.1109/EFTF.2010.6533665","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533665","url":null,"abstract":"We have demonstrated a laser-optically pumped Rb clock with a short-term stability of 8×10<sup>-13</sup> τ<sup>-1/2</sup>, using a simple cw pumping scheme. Further improvement towards the shot-noise limit of 2×10<sup>-13</sup> τ<sup>-1/2</sup> is expected from implementation of laser noise cancellation schemes, without need for pulsed operation or cold atoms. The main effects limiting the one-day stability of the clock, such as light shifts and clock cell temperature coefficient, are controlled and contribute <; 5×10<sup>-15</sup> to the clock stability at one day. A compact clock demonstrator Physics Package was realised that contains the full clock physics including the complete laser optical bench within 1.1 litres of volume. Work is in progress to demonstrate the expected long-term stability with this clock demonstrator.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"288 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115213992","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"VLBI time-transfer using CONT08 data","authors":"C. Rieck, R. Haas, K. Jaldehag, J. Johansson","doi":"10.1109/EFTF.2010.6533654","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533654","url":null,"abstract":"One important prerequisite for geodetic Very Long Baseline Interferometry (VLBI) is the use of frequency standards with excellent short term stability, i.e. hydrogen masers. This makes VLBI stations, which are often co-located with Global Navigation Satellite System (GNSS) receiving stations, interesting for studies of time- and frequency-transfer techniques. In this paper we present an assessment of VLBI time-transfer based on the data of the two week long consecutive IVS Cont08 VLBI-campaign by using GPS Carrier Phase (GPSCP). Cont08 was a 15 days long campaign in August 2008 that involved eleven VLBI stations on five continents. For Cont08 we estimated the worst case VLBI time link stability between the station clocks of ONSALA and WETTZELL to about 1.5e-15 at one day. Comparisons with clock differences estimated with GPSCP confirm the VLBI results. The paper also indicates time-transfer related problems of the VLBI technique as used today.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125424169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Stofanik, M. Minárik, I. Balaz, E. Cocherová, S. Kozinka
{"title":"Self-identification of differences between aging rates of two frequencies excited in the dual-mode crystal oscillator","authors":"V. Stofanik, M. Minárik, I. Balaz, E. Cocherová, S. Kozinka","doi":"10.1109/EFTF.2010.6533675","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533675","url":null,"abstract":"In this paper we introduce an extension of the self-temperature-sensing of stress compensated (SC) quartz resonator based on simultaneous excitation of two overtones (3rd and 5th overtone) - the slow thickness-shear modes (i.e. the c modes) in dual-mode crystal oscillator (DMXO). The extension is based on implementation of a self-identification of the differences between aging rates (long-term frequency instabilities) of the two mode's frequencies simultaneously excited in the quartz resonator. Processing of two excited c mode's frequencies enables to predict their shifts due to resonator's temperature variations in a wide range, where the characteristics of the c modes are free from significant anomalies.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"151 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123391561","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Margolis, G. Marra, V. Tsatourian, S. Lea, D. Reid, P. Gill
{"title":"Optical frequency combs and applications at NPL","authors":"H. Margolis, G. Marra, V. Tsatourian, S. Lea, D. Reid, P. Gill","doi":"10.1109/EFTF.2010.6533707","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533707","url":null,"abstract":"The phase noise measured at the “user” end with and without active suppression of the noise introduced in the optical link is shown in Fig. 4. At 1 Hz offset from the carrier the noise is suppressed by more than 10 dB to -101 dBc/Hz. The feedback bandwidth achieved is limited to about 10 Hz by the high voltage amplifier used to drive the fibre stretcher. With improved hardware the feedback bandwidth could be increased towards the theoretical limit of 2 kHz, imposed by the 0.5 ms round-trip travel time of the pulse train.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"183 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115070430","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
I. Procházka, J. Blažej, J. Kodet, U. Schreiber, W. Schafer, L. Cacciapuoti
{"title":"New technologies for laser time transfer and their possible application in the Galileo programme","authors":"I. Procházka, J. Blažej, J. Kodet, U. Schreiber, W. Schafer, L. Cacciapuoti","doi":"10.1109/EFTF.2010.6533727","DOIUrl":"https://doi.org/10.1109/EFTF.2010.6533727","url":null,"abstract":"We are presenting the new instrument, new technology available and new measurement technique proposal for the Galileo programme - optical detector for the laser time transfer. Combining the laser pulse emission times, propagation delays and satellite arrival times the ground to space clock comparison may be accomplished. The timing precision of the order of 1 × 10-12 seconds and a time transfer accuracy of 50 picoseconds is achievable. This precision and accuracy is at least one order of magnitude better in the optical region than in the radio frequency wavelength region. All the components of the proposed instruments are available in Europe, the ground segment of the proposed project is existing, the measurement techniques and data flow and processing procedures are well established. The implementation of new picosecond timing technologies and the laser time transfer into the Galileo programme will improve the precision and accuracy of the satellite on-board time scale and position prediction with unprecedent precision and accuracy. Both these facts will contribute to the Galileo system overall accuracy and performance and simultaneously will enable new experiments in fundamental physics.","PeriodicalId":415481,"journal":{"name":"EFTF-2010 24th European Frequency and Time Forum","volume":"482 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133594954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}