Development of Pseudo 3D Visualization System by Superimposing Ultrasound Images 超声图像叠加伪三维可视化系统的研制
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.29
Y. Iwashita, Shinji Tarumi, R. Kurazume, M. Hashizume
{"title":"Development of Pseudo 3D Visualization System by Superimposing Ultrasound Images","authors":"Y. Iwashita, Shinji Tarumi, R. Kurazume, M. Hashizume","doi":"10.1109/AT-EQUAL.2009.29","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.29","url":null,"abstract":"This paper presents the development of pseudo 3D visualization system of organs using 2D ultrasound images for a new medical instrument. The new instrument consists of an ultrasonic endoscope and an electro-magnetic measurement sensor. The pseudo 3D volume is reconstructed by superimposing ultrasound images captured by the ultrasonic endoscope. So the new instrument shows not only the surface of organs, but also the 3D volume of inside of organs. However, it was reported that the ultrasound probe influenced the accuracy of the sensors, so it is necessary to investigate the influence of the ultrasound endoscope to the sensor. In this paper, we propose a 3D volume reconstruction system using 2D ultrasound images, and show experimental results of accuracy measurement experiments of two kinds of electro-magnetic measurement sensors and 3D visualization with actual ultrasound images.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129518095","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Clinical Simulation - Efficacy and Tendency in Medical Technological Education 临床模拟——医学技术教育的效果与趋势
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.42
E. Toader, Daniela Damir
{"title":"Clinical Simulation - Efficacy and Tendency in Medical Technological Education","authors":"E. Toader, Daniela Damir","doi":"10.1109/AT-EQUAL.2009.42","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.42","url":null,"abstract":"The development of technology and using it on a large scale of medical devices implictes also legal, and social problems. The orientation of practical activities towards clinical simulation is specific to medical training, assuring a greater particularization in the training of the medical staff, contributing in a significant manner to the growth of practical performances and ethical responsibility. By reproduing a realistic medium, simulation does not substitutes clinical experience but completes it, assures the patient a safety and a better preparation for the medical staff.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128597483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Minimally Invasive Plate Osteosynthesis with Systems with Angular Stability in Complex Distal Femoral Fractures. Design, Biomechanics and Clinical Results 具有角度稳定系统的微创钢板内固定治疗复杂股骨远端骨折。设计,生物力学和临床结果
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.45
P. Sîrbu, E. Carata, T. Petreuș, R. Asaftei, P. Botez
{"title":"Minimally Invasive Plate Osteosynthesis with Systems with Angular Stability in Complex Distal Femoral Fractures. Design, Biomechanics and Clinical Results","authors":"P. Sîrbu, E. Carata, T. Petreuș, R. Asaftei, P. Botez","doi":"10.1109/AT-EQUAL.2009.45","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.45","url":null,"abstract":"The Less Invasive Stabilization System-Distal Femur(LISS-DF) and Locked Compression Plate-Distal Femur(LCP-DF) systems are internal fixators which avoid the problems related to the bone-implant interfaces. The purpose of this study is to present the biomechanics of the internal fixators as well as to evaluate the results in treating the complex distal femoral fractures using these systems. The clinical study included 15 fractures (3 type A2, 5 type A3, 4 type C2 and 3 type C3/AO). All fractures healed within a mean time of 12,4 weeks (with no infections, implant breakage or secondary displacement).These plates with angular stability represent the unique answer in difficult fractures with short distal fragment,osteoporotic fractures, fractures above knee arthroplasties and some open fractures.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129277684","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Simulating Human Reasoning in Mine-Like Object Inspection Assignments for a Formation of Unmanned Underwater Vehicles 无人潜航器编队类地雷目标检测任务模拟人类推理
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.39
N. Hallin, B. Johnson, H. Egbo, M. O'Rourke, T. Soule, D. Edwards
{"title":"Simulating Human Reasoning in Mine-Like Object Inspection Assignments for a Formation of Unmanned Underwater Vehicles","authors":"N. Hallin, B. Johnson, H. Egbo, M. O'Rourke, T. Soule, D. Edwards","doi":"10.1109/AT-EQUAL.2009.39","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.39","url":null,"abstract":"The purpose of this paper is to use human reasoning as a model for mine counter measure operations of a fleet of unmanned underwater vehicles. Learning from the complexities involved in information processing in real life scenarios, decision making processes by a fleet of unmanned underwater vehicles can be extensively simplified by the introduction of language-centered intelligence (LCI). LCI uses the logic associated with operating the vehicle, including the logic used for processing language, to evaluate scenarios and make decisions. Implementation of LCI occurred in two steps: first, a centralized inspection planner for a decentralized fleet of unmanned underwater vehicles was implemented, followed by a look-ahead inspections module which uses the inspections planner and portrays the application of LCI in a mine search operation.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131306621","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Signature Enzyme Identification Using Amperometric Biosensor 利用安培生物传感器识别特征酶
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.44
M. Hnatiuc, Mariarita Montereal
{"title":"Signature Enzyme Identification Using Amperometric Biosensor","authors":"M. Hnatiuc, Mariarita Montereal","doi":"10.1109/AT-EQUAL.2009.44","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.44","url":null,"abstract":"The amperometric biosensor has as fundament the enzyme-modified electrode. In this paper is present the k-means method to analyze the different parameter of input for identification the analyte concentration. The biosensor signal are acquired with Potentiostat - Autolab, PGStat10. The aim of this work is create an automatic system for data acquisition and processing. The analyte concentration identification depends of many parameters as the current corresponding to the neutral solution, the current peak of the saturated solution, dimensions of the electrodes, the time periods of saturation or neutralisation. These parameters are used as inputs classification system for a calibration current-time-concentration dependency. Amperometric biosensor has application in medicine, chemistry, physic, environment engineering.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"125 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131077472","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Laser Based Localization Techniques for Indoor Mobile Robots 室内移动机器人激光定位技术
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.43
L. Tamás, G. Lazea, M. Popa, I. Szoke, A. Majdik
{"title":"Laser Based Localization Techniques for Indoor Mobile Robots","authors":"L. Tamás, G. Lazea, M. Popa, I. Szoke, A. Majdik","doi":"10.1109/AT-EQUAL.2009.43","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.43","url":null,"abstract":"The localization problem in indoor environment based on LIDAR measurements is analyzed in this paper. Practical aspects of the localization are discussed including the implementations of the state estimation and registration algorithms. The localization framework developed is sufficient generic to be used in a variety of other autonomous vehicles. The results of the proposed navigation algorithms demonstrate a reliable and accurate position estimation for autonomous vehicles operating in a variety of environments.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121653589","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Daphne System for Neuromotor Control Evaluation: Reconfiguration Concepts 达芙妮神经运动控制评估系统:重新配置概念
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.10
A. Rovetta
{"title":"Daphne System for Neuromotor Control Evaluation: Reconfiguration Concepts","authors":"A. Rovetta","doi":"10.1109/AT-EQUAL.2009.10","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.10","url":null,"abstract":"This paper deals with the design of a new prototype, developed for the quantitative analysis of neuromotor diseases. The system, called Daphne, may measure the reaction of a person evaluating the time response in the motion of one finger of the hand, the velocity of phalanxes, the force exerted from the finger against a button. Daphne performs the more modern aspect connected with concurrent and simultaneous engineering, and utilizes results in design with colors applications. It represents a new step towards the possibility of quantitative analysis of the performances of the human hand both of mechanical phenomenon and electromyographic of neuromotor diseases, which provoke a decrease in upper and lower limbs action. Daphne is characterized by an ergonomic design of reduced dimensions; its hardware and user-friendly software allow an easy and quick use by non expert users as well. Moreover, the system can be used not only in medical field, but also in the daily health and sports. Daphne is a portable device that performs an analysis of multiple parameters, such as: reaction time, speed, tremor, force, and ability of coordination and synchronization of the motion of a finger. The system also satisfies the requirements for medical applications in accordance to European normative for safety and quality. The reconfiguration concepts are used for a larger spread of use of Daphne in many fields of biorobotics and rehabilitation.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124119179","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Quality Improvement of Knee Resurfacing with the Galileo Navigation System 伽利略导航系统对膝关节置换术质量的改善
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.22
W. Friedl, R. Imig
{"title":"Quality Improvement of Knee Resurfacing with the Galileo Navigation System","authors":"W. Friedl, R. Imig","doi":"10.1109/AT-EQUAL.2009.22","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.22","url":null,"abstract":"Clinical Problem: the knee joint has in the femur as well as tibia very long leaver arms. Therefore a misalignment of only 2 degrees of the femur already results with a 2cm distance of the mechanical axis to the centre of the femoral head. This leads to an asymmetric load distribution and so increased wear.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116905429","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Home Monitoring of Sleep Apnea Treatment: Benefits of Intelligent CPAP Devices 睡眠呼吸暂停治疗的家庭监测:智能CPAP设备的益处
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.25
D. Boișteanu, Raluca Vasiluţă, A. Cernomaz, C. Mucenica
{"title":"Home Monitoring of Sleep Apnea Treatment: Benefits of Intelligent CPAP Devices","authors":"D. Boișteanu, Raluca Vasiluţă, A. Cernomaz, C. Mucenica","doi":"10.1109/AT-EQUAL.2009.25","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.25","url":null,"abstract":"Obstructive sleep apneea syndrome is highly prevalent in adult population and increases cardiovascular morbidity and mortality. Nasal continuous positive airway pressure (CPAP) remains the treatment of choice for obstructive sleep apnoea (OSA). Automatic CPAP (APAP) can be use, not only for treatment but also for suggesting the optimum CPAP setting. Ninety-five newly diagnosed patients were included (mean age 51±9.6 years) with moderate and severe obstructive sleep apnea syndrome. The patients were randomly allocated to one of the investigated devices: APAP or fixed pressure CPAP. A lower mean effective pressure seen in AUTO group 7.67cm H2O vs CPAP 8.51 cm H2O (CI 95% 0.08 – 1.6, p=0.03) and CPAP patients presented statistically significant lower residual AHI (mean difference 1.6, CI 95% 0.7 – 2.5, p=0.001). As a conclusion the AUTO approach seems to be similarly effective as CPAP and provide a method for determining a single fixed pressure, suitable for long term treatment with a conventional CPAP device.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122691004","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Issues on Mechatronic Devices Aiming to Test Neuroprothesis 用于神经假体测试的机电设备问题
2009 Advanced Technologies for Enhanced Quality of Life Pub Date : 2009-07-22 DOI: 10.1109/AT-EQUAL.2009.16
M. Poboroniuc, C. Stefan, G. Livint, D. Irimia
{"title":"Issues on Mechatronic Devices Aiming to Test Neuroprothesis","authors":"M. Poboroniuc, C. Stefan, G. Livint, D. Irimia","doi":"10.1109/AT-EQUAL.2009.16","DOIUrl":"https://doi.org/10.1109/AT-EQUAL.2009.16","url":null,"abstract":"This paper presents three robotic structures and the software components aiming to emulate the human body motion. A neuroprosthesis is supposed to provide the control over the muscles of a disabled person during a rehabilitation process. The control method developed under Matlab®&Simulink® implements the mathematical model of the human body, the modeled muscles being electrically stimulated and the resulted motion is shown by controlling a humanoid-like robotic structure. The main feature of the proposed humanoid-like robotic structures is to support the training, development, implementation and testing of user defined control algorithms for a neuroprosthesis.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127933835","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信