{"title":"Development of Pseudo 3D Visualization System by Superimposing Ultrasound Images","authors":"Y. Iwashita, Shinji Tarumi, R. Kurazume, M. Hashizume","doi":"10.1109/AT-EQUAL.2009.29","DOIUrl":null,"url":null,"abstract":"This paper presents the development of pseudo 3D visualization system of organs using 2D ultrasound images for a new medical instrument. The new instrument consists of an ultrasonic endoscope and an electro-magnetic measurement sensor. The pseudo 3D volume is reconstructed by superimposing ultrasound images captured by the ultrasonic endoscope. So the new instrument shows not only the surface of organs, but also the 3D volume of inside of organs. However, it was reported that the ultrasound probe influenced the accuracy of the sensors, so it is necessary to investigate the influence of the ultrasound endoscope to the sensor. In this paper, we propose a 3D volume reconstruction system using 2D ultrasound images, and show experimental results of accuracy measurement experiments of two kinds of electro-magnetic measurement sensors and 3D visualization with actual ultrasound images.","PeriodicalId":407640,"journal":{"name":"2009 Advanced Technologies for Enhanced Quality of Life","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Advanced Technologies for Enhanced Quality of Life","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AT-EQUAL.2009.29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the development of pseudo 3D visualization system of organs using 2D ultrasound images for a new medical instrument. The new instrument consists of an ultrasonic endoscope and an electro-magnetic measurement sensor. The pseudo 3D volume is reconstructed by superimposing ultrasound images captured by the ultrasonic endoscope. So the new instrument shows not only the surface of organs, but also the 3D volume of inside of organs. However, it was reported that the ultrasound probe influenced the accuracy of the sensors, so it is necessary to investigate the influence of the ultrasound endoscope to the sensor. In this paper, we propose a 3D volume reconstruction system using 2D ultrasound images, and show experimental results of accuracy measurement experiments of two kinds of electro-magnetic measurement sensors and 3D visualization with actual ultrasound images.
超声图像叠加伪三维可视化系统的研制
本文介绍了一种新型医疗器械利用二维超声图像进行器官伪三维可视化系统的研制。新仪器由超声内窥镜和电磁测量传感器组成。通过叠加超声内窥镜捕获的超声图像重建伪三维体。因此,新仪器不仅能显示器官的表面,还能显示器官内部的三维体积。然而,有报道称超声探头会影响传感器的精度,因此有必要研究超声内窥镜对传感器的影响。本文提出了一种基于二维超声图像的三维体重建系统,并展示了两种电磁测量传感器的精度测量实验结果和实际超声图像的三维可视化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信