2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering最新文献

筛选
英文 中文
Study and design framework for e-Dengue teleconsultation system e-登革热远程会诊系统框架的研究与设计
A. Setyono, M. J. Alam, Beatrice Ann Maria Soosai
{"title":"Study and design framework for e-Dengue teleconsultation system","authors":"A. Setyono, M. J. Alam, Beatrice Ann Maria Soosai","doi":"10.1109/ICICI-BME.2011.6108626","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108626","url":null,"abstract":"Information and Communication Technology (ICT) in medical world has been widely used. The telemedicine system will be growing rapidly in accordance with the growth of the ICT. The use of technology can provide an easiness to patient to connect the doctor or nurse for getting medical treatment without visiting the hospital. In this paper, we propose a framework for developing e-Dengue teleconsultation system. It is built to allow the user (patient) to get early concern about the disease and performing teleconsultation via Internet or mobile phone. The developed system is expected to monitor dengue fever outbreak for reducing the number of dengue patient. The proposed framework can be used to develop practical telemedicine systems in future.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117136181","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
State of the art and future developments in electro mobility 电动汽车的技术现状和未来发展
H. Liess
{"title":"State of the art and future developments in electro mobility","authors":"H. Liess","doi":"10.1109/ICICI-BME.2011.6108589","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108589","url":null,"abstract":"This survey summarizes the present developments in the area of electro mobility. It compares the present achievements with the state of the art of the currently still dominating technology, which is mainly based on combustion engines and stresses the envisaged future implications.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115503162","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Role of pressure and wall shear stress in initiation and development of cerebral aneurysms 压力和壁面剪切应力在脑动脉瘤发生和发展中的作用
Nedya Utami, H. Zakaria, T. Mengko, O. Santoso
{"title":"Role of pressure and wall shear stress in initiation and development of cerebral aneurysms","authors":"Nedya Utami, H. Zakaria, T. Mengko, O. Santoso","doi":"10.1109/ICICI-BME.2011.6108629","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108629","url":null,"abstract":"Cerebral aneurysm is a cerebrovascular disorder in which weakness in the wall of a cerebral artery or vein causes a localized dilation or ballooning of the blood vessel. Other studies demonstrated that hemodynamic plays important role in the initiation and development of cerebral aneurysm. Wall shear stress and pressure are among the hemodynamic factors that contribute to the initiation and development of the cerebral aneurysm. In this study, the distribution of wall shear stress and pressure around cerebral aneurysms and its pre-aneurysms state were analyzed using the method of computational fluid dynamics.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132083828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Static output feedback control synthesis for nonlinear polynomial fuzzy systems using a sum of squares approach 基于平方和方法的非线性多项式模糊系统的静态输出反馈控制综合
B. W. Sanjaya, B. Trilaksono, A. Syaichu-Rohman
{"title":"Static output feedback control synthesis for nonlinear polynomial fuzzy systems using a sum of squares approach","authors":"B. W. Sanjaya, B. Trilaksono, A. Syaichu-Rohman","doi":"10.1109/ICICI-BME.2011.6108643","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108643","url":null,"abstract":"This paper addresses the static output feedback control synthesis problem for nonlinear polynomial fuzzy systems using a sum of squares (SOS) approach. The open-loop nonlinear systems is represented in the polynomial fuzzy model. By considering the closed-loop system in the output feedback control scheme and the polynomial Lyapunov functions that contain quadratic Lyapunov functions as special cases, sufficient conditions for a solution to the problems of stability analysis and control design can be derived in the representation form of the SOS. It can be numerically solved via the SOSTOOLS.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131199575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
GPS water vapor monitoring and TroWav updated for ENSO studies GPS水汽监测和TroWav更新ENSO研究
W. Suparta, Mandeep Jit Singh, M. A. Mohd. Ali, B. Yatim, Ahmad Norazhar Mohd Yatim
{"title":"GPS water vapor monitoring and TroWav updated for ENSO studies","authors":"W. Suparta, Mandeep Jit Singh, M. A. Mohd. Ali, B. Yatim, Ahmad Norazhar Mohd Yatim","doi":"10.1109/ICICI-BME.2011.6108591","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108591","url":null,"abstract":"The GPS receiver and the meteorology sensors have been installed at Universiti Malaysia Sabah (UMS), Kota Kinabalu (UMSK: 6.03°N, 116.12°E and 63.49 m) for study a climate condition that has associated with El Niño Southern Oscillation (ENSO). The atmospheric precipitable water vapor (PWV) derived from GPS technique was used as an indicator of ENSO detection. In the processing, the Niell Mapping Function (NMF) used to map the atmospheric delay from zenith to the line-of-site was updated using the Vienna Mapping Function (VMF). With GPS antenna co-located with meteorological sensors, the comparison of GPS PWV with time-dependent surface pressure and sea surface temperature (SST) during the first ten weeks observation found that surface pressure is opposed to the PWV changes.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123068768","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Color Image processing for measuring length deformation in compression test 压缩试验中长度变形测量的彩色图像处理
Riska Ekawita, Eko Widiatmoko, S. Suprijadi, H. Nawir, Endra Susila, K. Khairurrijal
{"title":"Color Image processing for measuring length deformation in compression test","authors":"Riska Ekawita, Eko Widiatmoko, S. Suprijadi, H. Nawir, Endra Susila, K. Khairurrijal","doi":"10.1109/ICICI-BME.2011.6108647","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108647","url":null,"abstract":"An image processing method was used to measure sample deformation during a compression test. The images were first calibrated from pixels to millimeters using a ruler which was included in the scene. Analyzing is done by discriminating objects by their colors. The results showed a good agreement with the actual values measured by a compression test instrument with errors up to 0.058 cm.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"69 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121024938","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Synthesis and characterization of Gd and Er co-doped ceria as solid electrolyte for IT-SOFC via solid state method Gd和Er共掺杂氧化铈作为IT-SOFC固体电解质的固态法合成及表征
A. Hardian, I. Ismunandar
{"title":"Synthesis and characterization of Gd and Er co-doped ceria as solid electrolyte for IT-SOFC via solid state method","authors":"A. Hardian, I. Ismunandar","doi":"10.1109/ICICI-BME.2011.6108651","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108651","url":null,"abstract":"Ceria has higher conductivity than the conventional SOFC electrolyte, yttria-stabilized zirconia (YZS) but has the drawback of measurable electronic conductivity, particularly at high temperatures. The aims of this work research are to synthesize several Gd and Er co-doped ceria materials as solid electrolyte for Intermediate Temperature Solid Oxide Fuel Cell (IT-SOFC) and to obtain the correlation between the average ionic radius of dopants and the value of their conductivity. Three set material have been choosen as target of this research. They are Ce<inf>1−x−y</inf>Gd<inf>x</inf>Er<inf>y</inf>O<inf>2−z</inf> (CeGdEr); Ce<inf>1−x−y</inf>Gd<inf>x</inf>Dy<inf>y</inf>O<inf>2−z</inf> (CeGdDy); and Ce<inf>1−x−y</inf>Gd<inf>x</inf>Nd<inf>y</inf>O<inf>2−z</inf> (CeGdNd). In this paper, one set material of CeGdEr have been synthesized, they are Ce90Gd5Er5, Ce85Gd5Er10, Ce85Gd10Er5, and Ce80Gd10Er10. Their structures have been investigated using X-Ray Diffraction (XRD) and refined it using Le Bail method. All material have the similar structure that is cubic structure with space group Fm3m, but only a little differences at their lattice parameter. The lattice parameter for Ce90Gd5Er5, Ce85Gd5Er10, Ce85Gd10Er5, and Ce80Gd10Er10 are 5,406(9) Å; 5,434(1) Å; 5,434(1) Å; and 5,430(2) Å, respectively. Moreover, Ce90Gd5rEr5 morphology have been investigated using Scanning Electron Microscope (SEM). The result is Ce90G5Er5 still has pore probably due to the low temperature of sintering. The result of EDS characterization show that there is no impurity in Ce90Gd5Er5 material.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132025053","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The effect of sericin application over hydroxyapatite surface on osteoblast cells proliferation 羟基磷灰石表面丝胶对成骨细胞增殖的影响
S. Sunarintyas, W. Siswomihardjo
{"title":"The effect of sericin application over hydroxyapatite surface on osteoblast cells proliferation","authors":"S. Sunarintyas, W. Siswomihardjo","doi":"10.1109/ICICI-BME.2011.6108613","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108613","url":null,"abstract":"Hydroxyapatite (HA) has been used clinically to treat bone defect. Modification of HA surface with respect to bone integration has been developed using treatments which have the potential to improve cells proliferation. Bombyx mori's sericin, a polymer protein that has polar side groups, have been known to accelerate cells attachment and proliferation. The aim of this study was to investigate the effect of sericin application over HA surface on osteoblast cells proliferation. HA discs (10 mm in diameter, 3 mm thick) were sintered. Three concentration of sericin (0.01, 0.5, and 0.1%) were applied on HA surface. Water contact angle was measured to evaluate the hydrophilicity of the disc surface. The discs were then seeded with MC3T3E1 osteoblast cells for proliferation test. The data were analyzed by Anova and LSD. Contact angle measurement showed significant increases of the hydrophilicity on sericin-modified HA surface. The amount of cells proliferation on HA discs (1.40±0.26) was significantly difference (p&#60;0.05) with HA+sericin 0.01% (2.23±0.20), HA+sericin 0.5% (2.33±0.24), HA+sericin 0.1% (2.37±0.20). Variation of sericin concentrations applied over HA did not influence any significant difference on cells proliferation (p>0.05). The conclusion was sericin application over HA surface increased the amount of osteoblast cells proliferation. Concentration of sericin application over HA (0.01, 0.05, 0.1%) did not influence cells proliferation.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132766440","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Vessel enhancement algorithm in digital retinal fundus microaneurysms filter for nonproliferative diabetic retinopathy classification 数字视网膜眼底微动脉瘤滤光器血管增强算法用于非增殖性糖尿病视网膜病变分类
R. Vidyasari, I. Sovani, T. Mengko, H. Zakaria
{"title":"Vessel enhancement algorithm in digital retinal fundus microaneurysms filter for nonproliferative diabetic retinopathy classification","authors":"R. Vidyasari, I. Sovani, T. Mengko, H. Zakaria","doi":"10.1109/ICICI-BME.2011.6108623","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108623","url":null,"abstract":"Diabetic Retinopathy is one of a complication of diabetes which can cause blindness. There are two levels of diabetic retinopathy which are nonproliferative diabetic retinopathy (NPDR) and proliferative diabetic retinopathy (PDR). The presence of microaneurysms in the eye is one of the early signs of diabetic retinopathy. Automated detection of microaneurysms in digital color fundus photographs is developed to help opthalmologist to detect the emergence of its early symptoms and determine the next action step for the patient. In this study we developed microaneurysms filter algorithm with the concept of vessel enhancement in order to extract the structure of microaneurysms in medical imagery, especially in the retinal image. Microaneurysms filter algorithm has been able to extract part of microaneurysms in the retinal image and detect pretty well. In addition, microaneurysms filters can also be developed to detect the next symptoms of diabetic retinopathy-hemorraghes (bleeding) that has features in common with microaneurysms which are larger and have irregular shape. Furthermore, the nonproliferative diabetic retinopathy (NPDR) classification system was developed based on the microaneurysms and hemorraghes detection. The system was tested against the patient data. Microanuerisyms detection results on DiaRetDB data has sensitivity value by 57,4% to ophthalmlogist 1, 35,37% for opthalmologist 2 and 62,68% for opthalmologist 3.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130797010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Consensus-based controllers for spacecraft attitude alignment: Simulation results 基于共识的航天器姿态对准控制器:仿真结果
H. Septanto, Bambang Riyanto-Trilaksono, A. Syaichu-Rohman, Ridanto Eko-Poetro
{"title":"Consensus-based controllers for spacecraft attitude alignment: Simulation results","authors":"H. Septanto, Bambang Riyanto-Trilaksono, A. Syaichu-Rohman, Ridanto Eko-Poetro","doi":"10.1109/ICICI-BME.2011.6108593","DOIUrl":"https://doi.org/10.1109/ICICI-BME.2011.6108593","url":null,"abstract":"Spacecraft formation flying control using consensus algorithm means each spacecraft or satellite in a team updates its state based on the information states of its local neighbours in such a way that the final information state of each agent converges to a common value. This paper discusses spacecraft formation within scope of rotational motions i.e. attitude alignment. Two attitude alignment controllers based on consensus algorithm proposed here.Simulations that run as preliminary proof a concept are presented. Simulations run indicate the proposed control laws might solve the attitude alignment problem i.e. consensus is achieved.","PeriodicalId":395673,"journal":{"name":"2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering","volume":"53 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114032212","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信