{"title":"Research on object color measurement system with aim function and multi-field angle","authors":"W. Meiying, Yao Jun","doi":"10.1109/ICEMI.2011.6037872","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037872","url":null,"abstract":"CCD spectrometer has commonly used to measure light color, but the survey in object color is not making much progress. This paper introduces an objects color measurement system composed by CCD spectrometer with illumination and observation in the condition of d/0. The system adopts light source to incidence the integrating sphere, after diffuse fully, the light illuminate the object. The object is imaged by objective lens in vertical direction on a reflector with holes, the light pass through the hole into a miniature integrating sphere, the mixed light enter CCD spectrometer. This color measurement system has advantages with point aim function, multi-field angle, viewable, etc.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121362954","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Air current field temperature control system based on predictive functional control","authors":"Li Jinyang, Meng Xiaofeng, Dong Dengfeng","doi":"10.1109/ICEMI.2011.6037824","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037824","url":null,"abstract":"In this paper, a structure of Air current field temperature control system (ACFTCS) is introduced and the dynamic model is developed from the point of view of total power balance (i.e., absorbed power is equal to dissipated power). Considering that dynamic model of ACFTCS is a high-order form, in order to analysis conveniently, a first order plus dead-time model of system is acquired by model reducing method. A predictive functional control (PFC) technique is applied to the temperature control of the ACFTCS on the basis of presentation of predictive functional control (PFC) algorithm for first order plus dead-time system. To verify the validity and effectiveness of the developed model and PFC control strategy, simulations and experiments are carried out. Experiment results shown that absolute and relative error are from 0.01to 0.24°C as well as 0.04% to 1.8%respectively when setpoint temperature varying from 5 to 65°C. Simulation results shown that the control strategy is effective and a good control performance is obtained in regard of setpoint tracking, robustness properties, and disturbance rejection.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122310759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Optical measuring technologies for scientific and industrial applications","authors":"Y. Chugui","doi":"10.1109/ICEMI.2011.6037754","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037754","url":null,"abstract":"Modern industry and science take novel optical measuring technologies for solving actual tasks, including safety problems for atomic, railway and oil industries. The novel TDI SIE's results in these trends are presented.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124395385","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Temperature control method for AC resistance standard","authors":"Qu Zhengwei, Wang Yunjing","doi":"10.1109/ICEMI.2011.6037797","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037797","url":null,"abstract":"Double Helix Resistor (DHR), a kind of calculable AC/DC resistor that can be traced to quantum standard, is being developed as AC resistance standard in National Institute of Metrology (NIM). In order to improve the value stability of DHR, this paper presents a practical temperature auto-feedback control method based on four-arm electric bridge. The bridge uses one thermistor to detect temperature variation and one adjustable resistor to regulate bridge ratio. The temperature inside the specially designed resistance box can be changed and well maintained through dynamically regulating and balancing the bridge. Measurement results show that the relative stability of DHR is greatly enhanced by using the presented method.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127887767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Studyon flow/pressure simulation subsystem for aircraft hydraulic energy system based on Fuzzy-PID control","authors":"Pei Runsen, Yu Zhaohui, Jiang Huijun","doi":"10.1109/ICEMI.2011.6037792","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037792","url":null,"abstract":"As conventional PID controller has the problem with the contradictions between rapidity and accuracy, this paper presents an algorithm about flow/pressure simulation subsystem of an aircraft using Fuzzy-PID controller. The paper at first discusses the technical difficulties of the system, then constructs the mathematical modeling of the proportion throttle valve which plays an important role in the subsystem, and designs a Fuzzy-PID controller, at last compares the proposed method with conventional PID algorithm through simulations and experiments . Its results show that the fuzzy PID control algorithm can achieve good static and dynamic performance, and its rapidity and control accuracy are better than conventional algorithms having met the practical requirements of simulation test of the indicators.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127440010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Guo-bin Feng, Z. Jianmin, Feng Gang, P. Yang, Wang Zhenbao, An Yuying
{"title":"Time-resolved beam profiler for far-field high repetition rate pulsed laser","authors":"Guo-bin Feng, Z. Jianmin, Feng Gang, P. Yang, Wang Zhenbao, An Yuying","doi":"10.1109/ICEMI.2011.6037672","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037672","url":null,"abstract":"Measuring far-field laser beam profile is an effective way to study the atmospheric transmission effects of high power laser and analyze the laser transmission efficiency in a long distance. A laser beam profiler based on detector array is developed to measure the far-field beam absolute intensity and temporal-spatial distribution of the high repetition rate pulsed laser beam. In the experiment, the pulse width of laser is about 100ns, the repetition rate is adjustable between 1 kHz and 20 kHz, and the diameter of the far-field beam is about 20cm. The detector array is composed of 297 Si-PIN photodiode detectors with the spatial resolution of 1cm in the central region. The image of the far-field beam profile is reconstructed with the bilinear interpolation method. The beam profiler is capable for measuring far-field beam profile of high repetition rate pulsed laser, with response wavelength between 400nm and 1100nm, minimal detectable pulse width of about 10ns, and dynamic range of energy density of 0.02–100µJ/cm2.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129071636","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Wu Jianping, Yu-tang Ye, Liu Lin, Huang Bingquan, Guo Tao
{"title":"High-speed FPGA-based SOPC application for currency sorting system","authors":"Wu Jianping, Yu-tang Ye, Liu Lin, Huang Bingquan, Guo Tao","doi":"10.1109/ICEMI.2011.6037771","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037771","url":null,"abstract":"A high-speed real-time currency sorting system based on SOPC of FPGA is designed against the existing problems in our country, such as the high complexity, the lower stability, the low real-time performance of complex algorithms for high-speed digital image signal and that the system is difficult to upgrade in real time, etc. The methods of software simulation, real-time debugging online are applied; the real-time processing of complex image algorithms has been achieved successfully and the system complexity has been reduced; the integration and stability of the system have been greatly improved. Furthermore the operation of FPGA could be performed in parallel and the responsive time of its hardware could be accurate to nanosecond (ns) level. So the real-time processing properties of the system have more advantages against other processing platforms. Because of the system programmable performance, the real-time updates of the system without changing the hardware circuit have also been implemented.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114933079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Hu Zhiqi, He Yujun, Hu Lizhang, Zhang Miao, Wang Zishuo
{"title":"Optical Fiber Bragg Grating center of wavelength detection filter algorithm","authors":"Hu Zhiqi, He Yujun, Hu Lizhang, Zhang Miao, Wang Zishuo","doi":"10.1109/ICEMI.2011.6037954","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037954","url":null,"abstract":"There are various optical noises in Fiber Bragg Grating (FBG) sensing system inevitably, these noises severely limit the accuracy of detection wavelength, and also bring many difficulties to wavelength detection. In practical applications, fiber grating systems are often connected to multiple FBG sensors; there are many reflection points, which make the noise situation more complex. In order to reduce these noises, we can use hardware to reduce the noise impact, but it will raise the costs or bring inconvenience. This paper presents a selection method, which can effectively reduce the noise impact of digital signal processing techniques, such as filtering and other methods. The proposed method is not only cost saving, easy to implement changes, but also has strong versatility.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"69 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116646690","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on the detection method based on human body quasi-electrostatic field","authors":"C. Xi, Zheng Wei, Cui Zhanzhong, L. Pengfei","doi":"10.1109/ICEMI.2011.6037834","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037834","url":null,"abstract":"When using conventional methods to detect human body face, there will always be several problems, such as high false alarm rate, the existence of blind corners and complex design. In this paper, an effective non-contact electrostatic detection method is proposed. The experiment results show that the electrostatic signals are mainly generated by the friction between the sole and the surface of floor when human body is moving. Meanwhile, estimating the speed of human body movement by electrostatic signal is feasible, which lay the foundation for the further research and application of electrostatic signals in human body detection.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116798909","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Automatic measurement of the equivalent static capacitance of ultrasonic transducers for dynamic matching","authors":"Qiang Luying, Liu Jilin, F. Xin","doi":"10.1109/ICEMI.2011.6037798","DOIUrl":"https://doi.org/10.1109/ICEMI.2011.6037798","url":null,"abstract":"The ultrasonic piezoelectric transducers have been widely applied in industrial fields, and they should be well matched to ensure its power transfer efficiency or measure accuracy. However, the electric characteristics of the transducers vary greatly with temperature, which will cause the deficiency of static matching. The existing tuning method or dynamic matching method may compensate for the variations, but they both have some limitations in applications. In this paper, a method based on the Wien bridge oscillation circuit is proposed to dynamically measure the equivalent static capacitor of ultrasonic piezoelectric transducer. It can overcome the limitations facing the conventional dynamic matching and help to realize self-adjusting of the matching inductors. This method is adaptable for a variety of ultrasonic instruments and devices, especially for the ultrasonic flow meters.","PeriodicalId":321964,"journal":{"name":"IEEE 2011 10th International Conference on Electronic Measurement & Instruments","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131088211","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}