Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts最新文献

筛选
英文 中文
Some Factors That Influence Film Growth on Sealed Relay Contacts 影响密封继电器触点膜生长的一些因素
Z. Chunyan, H. Jun-jia, Li Jin, Zhang Hanming, Liu Chengyan, W. Lizhong
{"title":"Some Factors That Influence Film Growth on Sealed Relay Contacts","authors":"Z. Chunyan, H. Jun-jia, Li Jin, Zhang Hanming, Liu Chengyan, W. Lizhong","doi":"10.1109/HOLM.2006.284081","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284081","url":null,"abstract":"In order to examine the surface film growth on the contacts of sealed relay, we designed a set of experiments to simulate the film growth and also did some verification. Analysis of average contact resistance values of normally closed contact and normally open contacts in certain environments was conducted for the contact samples with or without aging or burnish operations. Some discussions were made to determine the influence of these operations on film growth. Combined with checking the environments of some sealed relay samples, several conclusions were reached and also some advices for improving the production technology of sealed relay were given.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125480246","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Bending Test of Contact Materials 接触材料的弯曲试验
J. Song, C. Helmig, J. Feye-Hohmann, A. Schulz
{"title":"Bending Test of Contact Materials","authors":"J. Song, C. Helmig, J. Feye-Hohmann, A. Schulz","doi":"10.1109/HOLM.2006.284088","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284088","url":null,"abstract":"Bend formability is an important material property which affects the design and quality of the stamping process of connectors. Depending on the test methods the results of bend tests could be very different and even the results of a certain test method show a big statistical spread. We are developing a bend test with automatic crack detection. The main results are, comparing with the test with manual visual crack detection, the much higher repeatability and reproducibility of the test. Both material suppliers and connector makers would benefit from the improvement of the reliability of bend test.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129465595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Mass material transfer of Ag-SnO2 contact material in DC level Ag-SnO2接触材料在直流级的传质
F. Meng, Jianguo Lu, Ningyi Lu, Yongqing Zhu, Zhichao Chen, Qiutao Huang
{"title":"Mass material transfer of Ag-SnO2 contact material in DC level","authors":"F. Meng, Jianguo Lu, Ningyi Lu, Yongqing Zhu, Zhichao Chen, Qiutao Huang","doi":"10.1109/HOLM.2006.284057","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284057","url":null,"abstract":"A composite contact materials Ag-SnO2 have been used in low current switching devices for its good anti-welding properties and resistance to arc erosion. But the mass material transfer occurred at large surge current in DC switching now and then. Mass material transfer have an increased probability of early failures because the effective contact gap reduces or two contacts lock together. In this research, the shape and distribution of crystals at the contact surfaces were observed to analyse the reason of mass transfer. It was found that the shape and distribution of the crystals are like sunflower at the contact surfaces. The equal axes crystals distributed over the surfaces center, and the radial club-shaped crystals distributed around the center. One test showed that the melting phenomena at the interface of crystals had precedence over that in other sections at large surge current for the composite contact materials Ag-SnO2, it result in individual crystal transfer or several crystals transfer together.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133223452","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Theoretical and experimental determination of erosion rate due to arcing in electrical contacts 电触点电弧侵蚀率的理论和实验测定
M. Abbaoui, A. Lefort, D. Sallais, N. Ben Jemaa
{"title":"Theoretical and experimental determination of erosion rate due to arcing in electrical contacts","authors":"M. Abbaoui, A. Lefort, D. Sallais, N. Ben Jemaa","doi":"10.1109/HOLM.2006.284072","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284072","url":null,"abstract":"Erosion rate of electrical contacts is a very important parameter to understanding and evaluating the performances of contact materials and switching devices such as the life time. The most common measurement of arc erosion is the mass change of the contacts, determined by the weighing of the anode and the cathode, before and after the electrical tests. The erosion is well known to be a transfer from the anode to the cathode then from the cathode to the anode and finally a bilateral loss takes place. In this work, and to avoid the transfer phenomena, the mass of electrode after a large number of breaking operations is performed in the domain of bilateral erosion of the anode and cathode. Calculation of the evaporated mass by finite element simulation of thermal input and heat transfer to the electrode from the arc is made. It is found that the evaporated amount per unit of duration arc is in agreement for silver materials but for metal oxide it needs the knowledge of material properties and namely data of physical heat conduction.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130326441","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Research on the Failure Diagnostics Parameters and the Reliability Prediction Model of the Electrical Contacts 电触点故障诊断参数及可靠性预测模型研究
Fang Yao, Jianguo Lu, Jianrong Zheng, Zhang-wu Huang
{"title":"Research on the Failure Diagnostics Parameters and the Reliability Prediction Model of the Electrical Contacts","authors":"Fang Yao, Jianguo Lu, Jianrong Zheng, Zhang-wu Huang","doi":"10.1109/HOLM.2006.284067","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284067","url":null,"abstract":"The dynamic contact voltage of electromagnetic relays are measured in the paper. Both its statistics characteristic and its time sequence characteristic are studied in detail. Based on these characteristics, the failure diagnostics parameters are determined in the light of principle factor method and the failure prediction model of the electrical contact and are set up in accordance with the time sequence prediction and fuzzy method. By the model, the characteristic parameters of the contact failure can be predicted as can the contact reliability of the relay.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116163532","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Electrical Behavior of Flexible Cables With Intermittent Faults 间歇性故障柔性电缆的电气特性
K. H. Ip, C.P. Tang
{"title":"Electrical Behavior of Flexible Cables With Intermittent Faults","authors":"K. H. Ip, C.P. Tang","doi":"10.1109/HOLM.2006.284066","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284066","url":null,"abstract":"This paper presents a study on the effects of flexing on the electrical behavior of motor cables in application to automation and robotic systems. Focus is given to their resistance change from the pristine to the intermittent state. The samples were PVC-insulated 22 AWG wires with bare copper conductor strands. It was found that, under continual flexing, the cable resistance remained small and stable until the intermittent stage, where all the conductor strands were broken. The resistance then increased abruptly by over 40 times and became unstable. Yet, current managed to pass through the cable via the lapped strands. The phenomenon is closely related to electrical contacts under low forces and large displacements. Interestingly, with injected currents as for motor driving, an intermittent cable is \"healed\" with its resistance reduces drastically. Hence, the cable is still usable. Apart from resistance measurement, scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy (EDX) were applied to examine the broken strands. Traces of arcing were observed signifying (1) the passage of currents across the contacting strands, as well as (2) welding at their contact interfaces.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"203 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132832632","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Bouncing of a Reed Switch due to Coulomb's Electrostatic Force 库仑静电力作用下簧片开关的弹跳
N. Wakatsuki, A. Yamamoto
{"title":"Bouncing of a Reed Switch due to Coulomb's Electrostatic Force","authors":"N. Wakatsuki, A. Yamamoto","doi":"10.1109/HOLM.2006.284082","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284082","url":null,"abstract":"We proposed a method for suppressing arc ignition in mechanical contact devices using a transient current switch and a capacitor. However, a movable electrode in a conventional electromechanical contact device would often show bounce during a making and breaking operation against the opposite electrode. The frequent bounces would be troublesome. We studied phenomena with conventional reed switches using very slow make/break operation. Judging from measured data and FEM analysis, Coulomb's electrostatic force should not be neglected in order to suppress bounces. For the electric circuit analysis of breaking operation, we clarified the capacitance of the contacts just after the rupture of the metal bridge using FEM analysis. With the capacitance, we can estimate the contacting force due to the Coulomb's electrostatic force.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123493897","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrical Switching Life of Vacuum Circuit Breaker Interrupters 真空断路器的电气开关寿命
P. Slade, R.K. Smith
{"title":"Electrical Switching Life of Vacuum Circuit Breaker Interrupters","authors":"P. Slade, R.K. Smith","doi":"10.1109/HOLM.2006.284061","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284061","url":null,"abstract":"Experiments were performed to determine the electrical life of a vacuum interrupter as a function of current. The test currents ranged from the normal load currents of 630 A (rms) to 3150 A (rms) to higher currents of 20% to 100% of the rated short-circuit current. The two vacuum interrupter contact styles were evaluated: the transverse magnetic field (TMF) contact and the axial magnetic field structure (AMF). For the short-circuit current switching the AMF contact shows a longer electrical life, but the erosion may not be the only limitation on the life of the vacuum interrupter. The results will be discussed in terms of the expected performance of the two contact designs and on the operating life of a vacuum interrupter.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122670984","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
A Study of Metal Fiber Brush Operation on Slip Rings and Commutators 金属纤维刷在滑环和换向器上的应用研究
L. Brown, D. Kuhlmann-wilsdorf, W. Jesser
{"title":"A Study of Metal Fiber Brush Operation on Slip Rings and Commutators","authors":"L. Brown, D. Kuhlmann-wilsdorf, W. Jesser","doi":"10.1109/HOLM.2006.284093","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284093","url":null,"abstract":"The results of an investigation to determine the wear mechanism of metal fiber brushes on commutators and slip rings are presented. Metal fiber brushes were operated, while conducting direct current, on gold-plated copper rotors with and without unfilled gaps to simulate slip rings and commutators. Wear rates on unfilled-groove commutators were found to be only modestly higher than on slip ring rotors. Three possible causes for enhanced metal fiber brush wear on commutators were considered: i) accelerated \"adhesive\" wear controlled by contact spots, ii) fatigue induced wear and iii) \"fiber chopping\". All observations on wear debris and brush fibers are consistent with \"adhesive\" fiber brush wear on commutators as well as on slip rings; due to interlocking contact spots. Little to no evidence was found to support the other two hypotheses of fatigue induced wear and fiber chopping. The same conclusion also follows from comparing commutator wear rates with that on slip rings. A geometrical factor to account for the local elevation of brush pressure due to commutator grooves not supporting brush fiber tips was determined. This factor, of approximately 1.2, brought the wear data for commutators and slip rings into coincidence.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123231117","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Electrical contact behaviour of power connector during fretting vibration 微动振动时电源连接器的电接触特性
N. Jemaa, E. Carvou
{"title":"Electrical contact behaviour of power connector during fretting vibration","authors":"N. Jemaa, E. Carvou","doi":"10.1109/HOLM.2006.284097","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284097","url":null,"abstract":"It is well known that vibration of contact interfaces is the main cause of contact degradation by the so called fretting corrosion phenomena. In fact the process of generated particles by mechanical wear produce the increase of contact voltage frequently assimilated as high contact resistance in low power and signal connector. In high power connector, this degradation is expected to be accentuated by thermal effect generate by increasing contact voltage to melting and arcing voltage. The main objective of this work is to examine conjointly the wear amount and electrical behaviour of connector terminal under vibration and higher current stress. The spring lamellas of an automotive connector are submitted to high number of vibrations (10 to 10 ) whereas the pin is firmly attached to a fixed support. High frequency oscillation (100 Hz) with amplitude of 50 mum is used. The contact is made with copper alloy and coated with 2 mum of tin. The contact is inserted in resistive circuit supplied by 20 V and 3 A. The contact voltage is measured with fast sampling oscilloscope and the voltage histogram is built in real time. So, the removed mass in the track are evaluated by micro weight (1 mug). The main results show that at low level of wear observed during the earlier stage of fretting corresponds to pure constriction voltage <20 mV. However after this initiation period as the wear is increased, the contact voltage is increased and reaches few hundred millivolts (melting and fritting voltage). Finally in later stage of degradation, arcing voltage due to bounce phenomena is detected close 12 V. This short arc, observed for the first time in fretting area under power could accentuate the wear and the degradation process by erosion and mass transfer.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126511628","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书