{"title":"Glowing Contact Physics","authors":"J. Shea","doi":"10.1109/HOLM.2006.284064","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284064","url":null,"abstract":"There has been very little published research on glowing connections, especially their mechanisms and properties. In this study, oxide conductivity, surface X-ray maps, temperature measurements, and electrical waveforms were used to identify the structure and composition of glowing connections. It is shown that a glowing connection consists of a glowing molten liquid filament, which produced the orange glow that meanders on the surface of a solid copper oxide bridge that forms between two wires. Temperature and video measurements indicate that the glowing filament is in a liquid state. With the addition of oxide bridge resistivity measurements, the saw-tooth voltage pattern, typically seen in currents below 5Arms, has been explained. Also, when the glowing connection was slowly cooled, an impression of the glowing filament remained on the solid oxide. Subsequent SEM and X-ray mappings of this glow track revealed a track rich in copper, oxygen, and sulfur. This glow track explains the occasional low resistance path across the wires that can occur when the solid oxide bridge remains intact after cooling. Measurements in vacuum showed that oxygen was necessary to sustain the glowing filament even if there was a preexisting CuO oxide bridge present. Physical parameters affecting glow characteristics will be discussed; especially the semi-conducting nature of the copper oxide, and a model of the glowing contact, based on this data, that show some of the significant factors controlling the glow.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123101462","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Nomura, Y. Saitoh, K. Furukawa, Y. Minami, K. Horiuchi, Y. Hattori
{"title":"Press-fit Connector for Automobile ECUs","authors":"Y. Nomura, Y. Saitoh, K. Furukawa, Y. Minami, K. Horiuchi, Y. Hattori","doi":"10.1109/HOLM.2006.284089","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284089","url":null,"abstract":"A press-fit connector for automobile airbag electronic control units (ECUs) was developed and transferred to the mass- production phase by Sumitomo Wiring Systems, Ltd. and AutoNetworks Technologies, Ltd. in 2005. A press-fit connection is a solderless electrical connection technology, which utilizes the mechanical contact force generated between through-holes on a printed circuit board (PCB) and terminals with a width slightly larger than the through-hole diameter.This technology has been widely noted recently as a measure against the \"Lead Free Requirement\" of materials comprising electric/electronic devices. For the application of this technology to automobile connectors, we have to take into account the more severe environmental conditions required. Consequently, a press-fit connector for automobile airbag ECUs has been successfully developed and mass-produced from 2005. Furthermore, the authors have also developed a new type of hard tin plating on terminals, thus preventing the scraping-off of tin during the insertion process, that could result in a short-circuit on the PCB.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130355762","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New Algorithm for Electronic Short-Circuit Detection","authors":"T. Mutzel, F. Berger, M. Anheuser","doi":"10.1109/HOLM.2006.284063","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284063","url":null,"abstract":"New technologies and algorithms for an electronic short-circuit detection in low-voltage switchgears aiming for improvements in current limitation will be presented. For early short-circuit detection, the new \"Cubical-Criterion\" has been invented. The criterion uses the instantaneous values of current, current rise and current's 2nd derivatives with respect to time as a combined criterion. Combined network and switchgear simulation results will be presented. These simulations show achievable detection times and rates of current-limitation using the new criterion. The implementation of such algorithms in switchgear along with fast actuators can lead to additional current-limitation and therefore to improvements in power system and load protection.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"36 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133833760","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Rating Power Connectors Using End-of-Life Voltage Drop","authors":"R. Malucci, F. Ruffino","doi":"10.1109/HOLM.2006.284091","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284091","url":null,"abstract":"It was proposed in earlier work that change in voltage drop after aging be used to rate the performance of power contacts. In that paper it was shown that end-of-life failure criteria could be empirically modeled as a function of current for a given set of accelerated tests. This was established using a statistical model for the end-of-life change in voltage drop. The present paper expands on the previous work by extending the database to include samples with and without aging. In addition, the aged samples are exposed to accelerated-tests that go beyond the previous work. Consequently, in addition to modeling the end-of-life criterion, the progression of degradation is modeled to complete the picture. With both the failure criteria and voltage change modeled as functions of current and thermal aging respectively, a statistical method of rating power contacts in terms of current level and expected field life is developed. The database is obtained empirically by conducting high current cycling tests after accelerated aging of tin plated power contacts. This approach enabled the development of change in voltage drop failure criteria and mean change in voltage drop as functions of current level and accelerated aging respectively. The results are analyzed using basic contact theory in conjunction with an exponential statistical model. Moreover, it is shown that current density and the associated localized power dissipation are basic physical parameters that link aging to failure criteria. The end result is the development of a method using voltage drop to quantify the current level at which power contacts reliably work under a given set of field conditions.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117147931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Mechanism of ultra low force probing on Al electrodes","authors":"K. Kataoka, T. Itoh, T. Suga","doi":"10.1109/HOLM.2006.284059","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284059","url":null,"abstract":"We report on the breakdown of thin native oxide film formed on aluminum electrodes contacting metal probes at the contact force smaller than 0.1 mN when the surface aluminum oxide is difficult to break mechanically. The contact method with low contact force on aluminum electrodes is required for test probing of LSI for the next generation. A gold wire was used as a contact probe on aluminum electrode formed on Si wafer. To investigate the initial stage of the breakdown, the current flow is limited to the value below 1 muA using a large resistance inserted to the current circuit. It was found that ohmic contacts with resistance of about 10-100 Omega were obtained after the breakdown at 2-10 V. The contact resistance was found to be affected by the breakdown voltage, not by the current. Adhesion forces between the probe and the wafer were found to be 40-80 muN. A small current was observed before breakdown and may have influences on the breakdown voltage.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123300890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Noel, N. Lecaude, S. Correia, P. Gendre, A. Grosjean
{"title":"Electrical and tribological properties of tin plated copper alloy for electrical contacts in relation to intermetallic growth","authors":"S. Noel, N. Lecaude, S. Correia, P. Gendre, A. Grosjean","doi":"10.1109/HOLM.2006.284056","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284056","url":null,"abstract":"Many studies have been performed on reliability and accelerated testing of tinned contacts. The major contact resistance failure mechanism has been assigned to fretting by many authors. From a material point of view, one way to postpone or minimize the phenomenon is to select a coating presenting the best properties for the application. It is well known that the performances of an electroplated coating are determined by a broad variety of variables: metal or alloy, underlayer, layer finish, thickness and deposition process. The work undertaken here concerns tin electroplating processes. It is part of a large program aimed at determining an improved coating for connector type electrical contacts. The electrical and tribological properties of various coatings are analyzed and their behavior is correlated to physico-chemical and morphological characteristics of the layers. The thickness of the tin electroplate and the influence of an underlayer are examined for two tinning processes. Intermetallic formation is found to strongly influence the results.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127281114","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Mechanical Analysis of the Crimping Connection","authors":"S. Ogihara, K. Takata, Y. Hattori, K. Yoshida","doi":"10.1109/HOLM.2006.284070","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284070","url":null,"abstract":"In recent years, the demands for higher contact reliability of automotive connectors has increased as a result of the growth of electric components. Furthermore, we must reduce the time necessary to test the reliability of the crimp connection. This paper reports the FEM analysis and experimental examination of a crimp mechanical deformation. The calculated equivalent plastic strain by FEM was compared with the hardness distribution on the cross section of the crimped terminal with good correlation. We propose a new technique for determining the contact pressure with strain gauges. The results show an agreement with the material stress relaxation characteristic.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"96 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126026270","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Wave Propagation and High Frequency Signal Transmission across Contact Interfaces","authors":"R. Malucci, A. Panella","doi":"10.1109/HOLM.2006.284087","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284087","url":null,"abstract":"The resistance and capacitance of typical multi-point contact interfaces have been used to assess the impact on high frequency signal integrity. Previous work has reported that the impedance of degraded contact interfaces can affect high frequency signals. Previous work has also related how a contact interface can be treated as a circuit element consisting of a contact resistance in parallel with an effective contact capacitance. It was also stated that further refinement of this technique would help quantify high frequency effects from the multi-point contact impedance. This paper further extends the response of the contact interface to higher frequencies. Specifically, the paper includes research into the relationship of wave propagation relative to contact interface physics. Both transmission line parameters and field effects are used to study the impact of contact geometry and degradation on wave propagation. These effects are quantified and reported in this paper. Moreover, time domain data integrity analysis is used to further qualify the results. It is believed that this study helps provide a basis for further work relating the significance of contact degradation to effective transfer of high-speed packet data.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116346512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Developments in Fretting Studies applied to Electrical Contacts","authors":"J. McBride","doi":"10.1109/HOLM.2006.284083","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284083","url":null,"abstract":"A review of recent developments in fretting studies in electrical contacts is presented, focusing on developments in instrumentation methods, intermittency studies, wear assessment, and the application of new materials. The aim of the review is to look at the future directions of this important topic. The application areas discussed includes automotive connectors, in-body (in- vitro) electronic connection systems, and photo-voltaic connection systems all of which provide extreme operating environments for connector surfaces. Recent developments in the application of conducting polymers are also discussed. The review leads to a number of recommendations for further studies into the physics of contacts with micro-movement.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"73 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127396660","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An experimental study on minimum arc current of relay contacts and possible re-interpretation of the meaning thereof","authors":"M. Hasegawa, Y. Tamaki, Y. Kamada","doi":"10.1109/HOLM.2006.284080","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284080","url":null,"abstract":"A minimum arc current value for each contact material is one of the very important factors in consideration and comparison of arc discharge characteristics for proper selection of contact materials. In this paper, Ag and Ag alloy contacts were operated to break various DC load currents in the range of up to 1.5 A with 10-30 V, and occurrence rates of break arcs were investigated at each condition. As a result, it is confirmed that at the conventional minimum arc current level, break arcs on the order of several tens of mus occur at occurrence rate close to 100% when sufficient energy is supplied to contacts upon opening. Thus, careful attention should be paid to when using the term \"minimum arc current\" in order to avoid misinterpretation.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127459564","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}