Jingying Zhao, Jianguo Lu, Haitao Wang, Guojin Liu
{"title":"Study on Reliability Test Method of Over-load Relay","authors":"Jingying Zhao, Jianguo Lu, Haitao Wang, Guojin Liu","doi":"10.1109/HOLM.2006.284065","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284065","url":null,"abstract":"Over-load relay is widely used for electrical motor protection. Its reliability is becoming more and more important. This paper studies the reliability test method of over-load relay. According to the operation and failure modes of over-load relay, the protective success ratio is adopted as a reliability characteristic value. Based on the reliability estimation method and the sampling theory, the time or failure curtailed test plan is chosen and the sampling and checking plan is designed. By use of the test theory and method and taking the factual application of over-load relay into account, the reliability test process of overload relay is determined. In addition, using the reliability tester developed by ourselves, the reliability test for typical products is carried out.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128315961","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modelling the insulation displacement process-Results of a Finite-Element Model study-","authors":"S. Jorgens, H. Taschke","doi":"10.1109/HOLM.2006.284090","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284090","url":null,"abstract":"When considering the atmosphere of continuously growing pressure on time and costs in all areas of industry, it is clear that numerical simulations will increasingly dominate the development phase. In the final analysis, numerical methods will increase product and development quality and reduce the time and costs associated with testing. This trend has also become established in the field of connector design - and in this field in particular. The classic problems with regard to mechanical and thermal stability of contact carriers, the electrical and thermal stability of contact elements as well as their mutual coupling (multiphysics) are successfully processed with the help of the finite element method (FEM). This method has also lately been used to influence both the insulation displacement process as well as the design of the cutting elements (for the corresponding connectors). Within the context of this contribution to the conference, we will first offer a short overview of insulation displacement technology before we will discuss methods to predict the properties of IDT- connections during the development and the pre-production phase. The work presented here was focussed on the application of reasonable simulation approaches. The simulation results gained will be summarised and discussed comprehensively, including the general problems arising, in order to better understand the insulation displacement process and to deduce improved modelling approaches, which will be necessary to simulate IDT-connections both qualitatively and quantitatively in a correct manner. The simulation results will be compared with the metrologically determined values in order to describe the possibilities as well as the limits that the various model approaches have to offer. Furthermore first approaches for stranded wires and an example of use will be presented.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128981235","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Influence of the Bonding Area of welded Contact Tips on Contact Erosion","authors":"D. Spath, V. Behrens, M. Finkbeiner, O. Lutz","doi":"10.1109/HOLM.2006.284084","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284084","url":null,"abstract":"The influence of both the size and location of the bonding area of resistance-welded contact tips made of Ag/SnO2 86/14 on contact erosion was examined on an 11-kW AC contactor. AC4 utilization category at 110 A was used to perform the service life tests. It could be shown that the medium erosion rate was only slightly increased with bonding areas of down to 30%. The 90% erosion rate value, however, significantly rose with the decrease of the bonding area. Bonding areas of 30 and 40% resulted in partial early failure by the detachment of the contact tip. No remarkable influence of the bonding area to erosion values related to the arc moving direction could be determined. It was proven that the overtemperature value was evidently no function of the bonding area under the conditions specified in these tests.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"36 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116617341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Thermal analysis of hermetically sealed electromagnetic relay in high and low temperature condition","authors":"Ren Wanbin, Liang Huimin, Zhai Guofu","doi":"10.1109/HOLM.2006.284073","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284073","url":null,"abstract":"Hermetically sealed structure is the optimal style to protect electromagnetic relay (EMR) from formidable working environment. Each product shall be subjected to thermal environment shock in accordance with MIL-STD-202 from -65degC to +125degC temperature, so it is of great importance for thermal analysis of EMR to increase the thermal stability and reliability requirement. In this paper, special finite element analysis (FEM) software ANSYS, was used for the accurate simulation of the internal relay structure. The elevated temperature characteristic of relay is investigated considering comprehensive thermal conductivity and convection effect. Internal complex heat transfer paths of EMR are determined and the influence of different temperature condition of inert gas on thermal performance is also researched. The results of the analysis can be useful for reliability thermal design of hermetically sealed EMR.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"124 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121955316","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electrical Contacts Condition Diagnostics Based on Wireless Temperature Monitoring of Energized Equipment","authors":"B. Chudnovsky","doi":"10.1109/HOLM.2006.284068","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284068","url":null,"abstract":"Continuous exposure of electrical contact to elevated temperatures contributes to the downgrading of contact quality. Gradual degradation of contact surfaces induces developing conduction problems resulting in local temperature rise. The paper presents industrial case studies of continuous temperature monitoring of electrical contacts in energized equipment using wireless system with miniature temperature sensors. Wireless technology for on-line condition monitoring is applicable both as standalone system and with an interface with power quality monitoring system. Continuous on-line temperature monitoring combined with detail analysis of thermal contact behavior in correlation with the load current provides the means to evaluate physical condition of electrical contacts and detect abnormality. Practical applications of wireless temperature monitoring technique demonstrate its importance for properly and timely performed condition-based maintenance preventing possible disruption of electrical service. Observational data collected for several years of continuous contact temperature monitoring may be used for development of diagnostic and prognostic algorithms applicable for maintenance scheduling and better assets management.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129661993","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Applications and Properties of Nanomaterials in Electrical Contacts; Holm Conference Panel Discussion","authors":"R. Malucci, B. Rickett","doi":"10.1109/HOLM.2006.284095","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284095","url":null,"abstract":"This panel discussion covers the subject of nano-structures and their potential application in electrical contacts. It consists of a series of four short talks provided by experts in the field of nanotechnology. The talks briefly cover the areas of Electrical Contacts at Nano-Scales, Tribological Behavior of Nano-Structures, Electrical and Thermal Behavior of Nano-scale Materials and Chemical Properties of Nanoscale Layers. Each talk will be followed by a short question period to give the audience a chance to clarify details that were covered in the talk. Subsequently, a 20-minute open discussion will follow the talks to debate the benefit of using nano-scale structures in electrical contacts.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130415443","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Comparison of Contact Erosion for Opening Velocity Variations for 13 Volt Circuits","authors":"Z. Chen, G. Witter","doi":"10.1109/HOLM.2006.284058","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284058","url":null,"abstract":"Contact erosion and material transfer of several types of silver metal oxides have been studied by using a new model relay under different opening velocities and gaps. The test was conducted with 13 volt automotive inductive loads with break only operation. The opening speed of testing was adjusted to represent the different commercial relays. Contact material transfer was measured with digital balance. The results indicate that the material transfer is not only determined by metal oxide content but is also affected by opening speed and gap. Also the materials made by the internal oxidation method demonstrated stronger anti-erosion than materials made by the powder metallurgical method. The opening speed has a great influence on material transfer and opening gap affects the net material loss. A balance for transfer of contact material can be reached by adjusting the velocity of opening to a contact material.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129978201","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Factors Influencing the Fretting Corrosion of Tin Plated Contacts","authors":"Tetsuya Ito, M. Matsushima, K. Takata, Y. Hattori","doi":"10.1093/ietele/e90-c.7.1412","DOIUrl":"https://doi.org/10.1093/ietele/e90-c.7.1412","url":null,"abstract":"In recent years, there have been ever-increasing demands to miniaturize automotive connectors. However, because the contact force decreases as connectors are miniaturized further, fretting corrosion, which is a typical problem occurring with low-force electric contacts, is expected to become a more serious problem in the future. This time we developed a new experimental device capable of controlling the contact load, fretting amplitude, fretting frequency, contact part temperature and humidity. In this report, we used the design of experiments, and quantitatively evaluated the extent of the influence of the expected factor (in terms of load, amplitude, and plating thickness, etc.) on the fretting phenomenon, which occurs in the tin plating of the connector terminal. Moreover, based on SEM examination, we analyzed the surface and cross section of the contact parts when degradation occurs, and considered the mechanism of the degradation.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122635898","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Haitao Wang, Jingqin Wang, M. Wen, Jingying Zhao, Guojin Liu
{"title":"Preparation of Ag/SnO2+La203+Bi2O3 Contact Material","authors":"Haitao Wang, Jingqin Wang, M. Wen, Jingying Zhao, Guojin Liu","doi":"10.1109/HOLM.2006.284076","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284076","url":null,"abstract":"A super-fine compound powder, Ag/SnO<sub>2</sub>-La<sub>2</sub>O<sub>3</sub>-Bi<sub>2</sub>O<sub>3</sub> has been obtained using the chemical co-precipitation method. The contact material has been made by this compound power through forming, sintering, re-pressing and annealing to improve its conductivity, density and hardness. The sample material has been achieved by the following preparation process parameters: forming at a pressure of 30 tons, sintering at 920degC for 8h, re-pressing at a pressure of 40 tons and annealing at 150degC for 0.5h. The electrical testing results show that the new Ag/SnO<sub>2</sub>-La<sub>2</sub>O<sub>3</sub>-Bi<sub>2</sub>O<sub>3</sub> contact material has better electrical behavior compared with traditional Ag/CdO.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129930064","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Su Xiuping, Lu Jianguo, Gao Bingjun, L. Guojin, L. Wenhua
{"title":"Determination of the Best Closing Phase Angle for AC Contactor Based on Game Theory","authors":"Su Xiuping, Lu Jianguo, Gao Bingjun, L. Guojin, L. Wenhua","doi":"10.1109/HOLM.2006.284085","DOIUrl":"https://doi.org/10.1109/HOLM.2006.284085","url":null,"abstract":"Any contactor bounce is undesirable since this causes arcing which shortens the life of the contacts when contacts close. The rebounds and the closing speeds are different with the closing phase angle of the electromagnetic coil voltage switching on when contactors close. This paper discussed the determination of the best closing phase angle of the electromagnetic coil voltage switching on. Taking closing phase angle as optimization variable, the closing velocities of three phase contacts and armature as objectives, and taking moving velocities lower than their worst values as restrictions, the optimization model was established. Game theory was introduced and adopted to solve the multi-objectives optimization problem. Taking CJ20 AC contactor as an example, the best closing phase angle was determined by combing the calculating and testing results.","PeriodicalId":304571,"journal":{"name":"Electrical Contacts - 2006. Proceedings of the 52nd IEEE Holm Conference on Electrical Contacts","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115151543","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}