Life estimation of transformer insulation under repeated impulses 重复脉冲作用下变压器绝缘寿命估算
S. Balaji, S. Usa
{"title":"Life estimation of transformer insulation under repeated impulses","authors":"S. Balaji, S. Usa","doi":"10.1109/CATCON.2013.6737522","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737522","url":null,"abstract":"Oil Impregnated Paper (OIP) is commonly used dielectric material in transformer windings. The most of the transformer winding failures are due to breakdown of dielectric material. The breakdown mechanism of composite dielectric undergoes gradual degradation in nature. OIP is subjected to rapid degradation when it is subjected to overvoltages. The severity of the degradation depends on steepness of the waveshape. It is necessary to analyze the characteristics of OIP for varying wavefronts (tf) ranging from lightning to Very Fast Transient Overvoltages (VFTO). V-N characteristic provides detailed information on degradation with respect to repeated overvoltages. The time interval (At) between the successive impulse overvoltages plays a vital role in determining the V-N characteristics. In this paper, an attempt has been made to predict the V-N characteristics for any (tf) and (At) using exponential model and the results are validated with test waveshape of 0.78/50 μs with Δt = 2s. Apart from the V-N characteristics of OIP, the remaining life of the transformer can be estimated from degree of polymerization (DP) using Ekenstam second order equation.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125379498","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Analysis of variations in measured recovery voltage peaks due to presence of moisture in insulation of power transformers 分析由于电力变压器绝缘中存在湿气所测得的恢复电压峰值的变化
S. Mallik, P. Purkait, N. Mohandas, S. V. Kulkarni
{"title":"Analysis of variations in measured recovery voltage peaks due to presence of moisture in insulation of power transformers","authors":"S. Mallik, P. Purkait, N. Mohandas, S. V. Kulkarni","doi":"10.1109/CATCON.2013.6737494","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737494","url":null,"abstract":"The main focus of this article is to investigate the relation between recovery voltage peaks and moisture content in oil-paper insulation system in power transformers. It investigates the causes of non-standard recovery voltage peaks and uses an algorithm to simulate different oil-paper moisture conditions. Two different transformers have been studied and an attempt has been made to correlate the shifting of recovery voltage peaks in the response to variations in oil and paper moisture contents. A brief discussion on the appearance of subdominant peaks has also been given to relate their presence with interfacial polarization processes.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133227691","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Understanding the correlation between dielectric response measurement results and equivalent circuit pole locations of a transformer oil paper insulation system 了解变压器油纸绝缘系统的介电响应测量结果与等效电路极位之间的关系
S. K. Ojha, P. Purkait, D. Mukherjee, Sivaji Chakravorti
{"title":"Understanding the correlation between dielectric response measurement results and equivalent circuit pole locations of a transformer oil paper insulation system","authors":"S. K. Ojha, P. Purkait, D. Mukherjee, Sivaji Chakravorti","doi":"10.1109/CATCON.2013.6737493","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737493","url":null,"abstract":"Lifetime of a transformer is determined by the condition of its oil paper insulation. Presence of moisture in the insulation reduces the dielectric strength and hence the remaining life. During the entire period of operation of transformer, moisture diffusion between oil and paper takes place, this causes the transformer to operate in a state of thermodynamic non equilibrium. Paper insulation of a transformer serves as the prime source of water in transformer. Oil moisture content can be directly measured using Karl Fischer Titration method. But determination of paper moisture will involve the collecting of paper sample from the transformer which will make the test destructive. Hence paper moisture is estimated from the standard equilibrium curves. Recently, pole values determined from the traditional linear model of the insulation structure have been used to serve as a basic guide for assessing the condition of oil paper insulation system of a transformer. Theoretically the RC branches of the linear equivalent model with lower time constant reflects the condition of insulation of oil and higher time constant branch reflects the condition of solid insulation. From this basic idea pole location of different branches are calculated and reported in this article. This present work attempts to assess the condition of insulation by locating position of the poles, and how pole locations vary with paper and oil moisture as well as temperature.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128417225","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Simulation of Bewley's lattice diagram using MATLAB 用MATLAB仿真Bewley晶格图
Brajagopal Datta, S. Chatterjee
{"title":"Simulation of Bewley's lattice diagram using MATLAB","authors":"Brajagopal Datta, S. Chatterjee","doi":"10.1109/CATCON.2013.6737466","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737466","url":null,"abstract":"Bewley's lattice diagram is a graphical method that has been widely used for determining value of a travelling wave (TW) in transient analysis. The method provides a very simple representation for voltage and current surge reflections as it travels along the transmission system. From an extensive literature survey it was concluded that till date use of digital computers by developing a program for the same computation has not been done. This paper aims at an approach for the development of a program for this method using MATLAB. Coding has been done for few specific practical cases of transmission system. Results for all those cases have been presented in this paper. And finally with the achieved results a discussion has been done on the possible future work in this direction.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130464133","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Experience with transformer interaction with low amplitude high oscillatory switching transients in a power utility network 有在电力网络中变压器与低幅高振荡开关瞬态相互作用的经验
Poulomi Mitra, Sreejeet Ghosh, A. De, A. Chakrabarti
{"title":"Experience with transformer interaction with low amplitude high oscillatory switching transients in a power utility network","authors":"Poulomi Mitra, Sreejeet Ghosh, A. De, A. Chakrabarti","doi":"10.1109/CATCON.2013.6737471","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737471","url":null,"abstract":"Resonance in electrical equipment is a major concern regarding the protection of such devices in a grid connected power system. A portion of an integrated steel plant of Steel Authority of India Limited has been simulated to identify high frequency voltage transients across the distribution transformer winding at various switching events using Alternative Transient Program (ATP). The frequencies in voltage oscillation, generated by switching, are distinguished by Short Time Fourier Transform (STFT) using MATLAB and are analyzed by tallying with the natural frequencies of winding using Frequency Response Analysis (FRA) method. This paper emphasizes the winding resonance due to switching which is the cause of transformer failure of Durgapur Steel Plant (DSP). The results have revealed that under certain switching circumstances the voltage level of the winding exceeds the transformer's Basic Insulation Level (BIL) which leads to the failure of transformer.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132064372","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Detection of simultaneous unbalanced under-voltage and broken rotor fault in induction motor 感应电动机欠压不平衡和转子断动同时故障的检测
S. Sridhar, K. Rao
{"title":"Detection of simultaneous unbalanced under-voltage and broken rotor fault in induction motor","authors":"S. Sridhar, K. Rao","doi":"10.1109/CATCON.2013.6737472","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737472","url":null,"abstract":"In recent years voltage unbalance and fault analysis in induction motor independently has been researched by engineers dealing with power quality issues. The exposure of the motor to unbalanced supply, combined with broken rotor bar fault significantly increases the temperature and reduces the efficiency and life of the motor. In this paper the effect of unbalance on broken rotor bar fault of the squirrel cage induction motor is analyzed. The performance of the induction motor is studied using symmetrical component analysis for the extracted stator current. The electromagnetic torque is analyzed, and is found to give sufficient information about the fault and the unbalance condition. The simulation of the proposed methodology is done using MATLAB SIMULINK.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129521918","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Characterization of short circuit faults and incipient insulation degradation between stator winding turns of induction motor 感应电动机定子绕组匝间短路故障及早期绝缘退化的表征
Santanu Das, P. Purkait, S. Chakravorti
{"title":"Characterization of short circuit faults and incipient insulation degradation between stator winding turns of induction motor","authors":"Santanu Das, P. Purkait, S. Chakravorti","doi":"10.1109/CATCON.2013.6737473","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737473","url":null,"abstract":"The aim of this work is to present a method to discriminate between dead short circuit and incipient or partial short circuit in induction motor stator winding when the dead short circuit conditions are introducing unbalance in three phase stator currents similar to the latter case and that too under different loading conditions. Unbalance in motor current may also be introduced by unbalance in supply voltage. Any unbalance in the motor currents caused either by fault or supply voltage unbalance or even inherent asymmetry in motor circuit makes negative sequence current to crop up. This paper presents a scheme to estimate the magnitude of negative sequence current introduced by motor faults only. Negative sequence current analysis employing Power Decomposition Technique (PDT) has been used to derive positive and negative sequence components from three phase current and voltage signals. Three-phase instantaneous current signals and voltages are both sampled simultaneously in time series. Entire analysis presented in this paper is based on experimentally obtained motor current signatures. The obtained results provide a satisfactory level of accuracy in terms of segregating two different types of stator fault cases.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128607931","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Dual zone industrial induction heater using MOSFET based high frequency hybrid resonant converter 基于MOSFET的高频混合谐振变换器的双区工业感应加热器
P. Sadhu, Ananyo Bhattacharya, N. Pal
{"title":"Dual zone industrial induction heater using MOSFET based high frequency hybrid resonant converter","authors":"P. Sadhu, Ananyo Bhattacharya, N. Pal","doi":"10.1109/CATCON.2013.6737523","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737523","url":null,"abstract":"In this paper a converter is described where both series and parallel resonant circuits are used. To minimize the losses, switching instant is chosen at zero current crossover instant. The converter scheme described in this paper consists of four MOSFETs in H-bridge configuration. It is used for industrial induction heating purposes comprising of dual zone heating. The switching frequency lies in the range of 30 kHz to 100 kHz. Maximum efficiency is achieved for operating frequency of 66.66 kHz. Earlier voltage controlled devices like IGBTs, MCTs were tested and found that the system was working perfectly. For above mentioned frequency, IGBT was the better option considering conduction losses. But the cost of power MOSFETs is lower than the same power rating IGBTs and MCTs. So, by considering the overall cost of the dual zone industrial induction heater, slightly greater conduction losses of MOSFETs can be accepted. For the system efficiency optimization, different control strategies are discussed. The two zones have different pipe diameters and output power levels. This paper presents a new approach of dual zone operation depending on the demand of hot fluid flow in the industrial application. It is saving the energy cost when it is operating in under load condition. The circuit is simulated with PSPICE and simulation results are specified at the end.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117000767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Prediction of transformer winding displacement from frequency response characteristics 从频率响应特性预测变压器绕组位移
M. Sathya, Ajith John Thomas, S. Usa
{"title":"Prediction of transformer winding displacement from frequency response characteristics","authors":"M. Sathya, Ajith John Thomas, S. Usa","doi":"10.1109/CATCON.2013.6737517","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737517","url":null,"abstract":"The failures caused by short circuits are one of the causes of transformer outages. The short circuit currents induce excessive forces in the transformer windings which result in winding deformations affecting the mechanical and electrical characteristics of the winding. In the present work, a 722VA transformer winding is considered for the short circuit force and displacement analyses. The winding is subjected to short circuit current and the respective displacement of the winding is simulated and compared with the measurement. By using Finite element analysis, change in equivalent circuit parameters due to displacement is calculated and corresponding change in sweep frequency response is measured using SFRA. An attempt has been made to predict the displacement profile from change in resonant frequency in case of displaced conditions.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121139024","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Partial discharge source classification by support vector machine 基于支持向量机的局部放电源分类
R. Sarathi, I. P. Merin Sheema, R. Abirami
{"title":"Partial discharge source classification by support vector machine","authors":"R. Sarathi, I. P. Merin Sheema, R. Abirami","doi":"10.1109/CATCON.2013.6737508","DOIUrl":"https://doi.org/10.1109/CATCON.2013.6737508","url":null,"abstract":"The interpretation and recognition of partial discharges due to different sources were studied by Support Vector Machine, which is a statistical learning technique. The classification based on the Support Vector Machine technique, requires a preprocessing of the input data for different partial discharge sources, obtained by phase resolved partial discharge analysis. The phase resolved partial discharge data was divided into smaller phase windows and the average magnitude, maximum magnitude and the number count in each phase window is determined. The high dimensionality of the feature data set is reduced by adopting Principle Component Analysis method. This reduced feature data set is given as the input vector to the SVM and the partial discharge sources are classified by adopting, Radial Basis Function kernel.","PeriodicalId":290479,"journal":{"name":"2013 IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121409613","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书