International Conference on Advanced Optical Materials and Devices最新文献

筛选
英文 中文
TiO2-PHT interface influence to charge carrier photo generation and recombination TiO2-PHT界面对载流子光生成和复合的影响
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-12-02 DOI: 10.1117/12.815634
G. Sliaužys, G. Juška, K. Genevičius, J. Smått, M. Lindén, R. Österbacka
{"title":"TiO2-PHT interface influence to charge carrier photo generation and recombination","authors":"G. Sliaužys, G. Juška, K. Genevičius, J. Smått, M. Lindén, R. Österbacka","doi":"10.1117/12.815634","DOIUrl":"https://doi.org/10.1117/12.815634","url":null,"abstract":"In this paper the influence of TiO2/polymer (RR-P3HT) interface to photo generated charge carriers separation and recombination have been studied. The quantum efficiency and charge carrier recombination were studied in heterojunctions of TiO2 (prepared with porous or flat interface) and spin coated RR-P3HT polymer film using time of flight (TOF) and double injection (DoI) transient methods. From the shape of the TOF transients it was determined that the charge carrier generation is taking place in the vicinity of the TiO2/P3HT interface. Samples with porous TiO2 films show better charge carrier separation, but the deep trapping of charge carriers at the interface appear. The charge carrier recombination is trimolecular (Auger type recombination) with the similar values of recombination coefficients in both types of samples.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115093040","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
GaAs/AlGaAs heterojunction as a fast detector of infrared laser pulses GaAs/AlGaAs异质结作为红外激光脉冲的快速探测器
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815954
S. Ašmontas, J. Gradauskas, V. Kazlauskaitė, A. Sužiedėlis, E. Sirmulis, M. Vingelis
{"title":"GaAs/AlGaAs heterojunction as a fast detector of infrared laser pulses","authors":"S. Ašmontas, J. Gradauskas, V. Kazlauskaitė, A. Sužiedėlis, E. Sirmulis, M. Vingelis","doi":"10.1117/12.815954","DOIUrl":"https://doi.org/10.1117/12.815954","url":null,"abstract":"We present experimental study of photoresponse in small area GaAs/AlGaAs heterojunction planar detector induced by nanosecond CO2 laser pulses. This device revealed itself as a fast IR sensor operating at room temperature. Hot carrier effects are proposed to be responsible for the photoresponse formation.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126489386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye 弱视眼和离焦眼对等亮度彩色刺激的感知
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815794
G. Krumina, M. Ozolinsh, G. Ikaunieks
{"title":"The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye","authors":"G. Krumina, M. Ozolinsh, G. Ikaunieks","doi":"10.1117/12.815794","DOIUrl":"https://doi.org/10.1117/12.815794","url":null,"abstract":"In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminant coloured stimuli (white symbols on a yellow background, grey symbols on blue, green or red background). Thus isoluminant tests had colour contrast only but had no luminance contrast. Visual acuity evaluated with the standard method and colour tests were studied for subjects with good visual acuity, if necessary using the best vision correction. The same was performed for subjects with defocused eye and with true amblyopia. Defocus was realized with optical lenses placed in front of the normal eye. The obtained results applying the isoluminant colour charts revealed worsening of the visual acuity comparing with the visual acuity estimated with a standard high contrast method (black symbols on a white background).","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134443920","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Gas in scattering media absorption spectroscopy - GASMAS 气体在散射介质中的吸收光谱
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.816469
S. Svanberg
{"title":"Gas in scattering media absorption spectroscopy - GASMAS","authors":"S. Svanberg","doi":"10.1117/12.816469","DOIUrl":"https://doi.org/10.1117/12.816469","url":null,"abstract":"An overview of the new field of Gas in Scattering Media Absorption Spectroscopy (GASMAS) is presented. GASMAS combines narrow-band diode-laser spectroscopy with diffuse media optical propagation. While solids and liquids have broad absorption features, free gas in pores and cavities in the material is characterized by sharp spectral signatures, typically 10,000 times sharper than those of the host material. Many applications in materials science, food packaging, pharmaceutics and medicine have been demonstrated. So far molecular oxygen and water vapour have been studied around 760 and 935 nm, respectively. Liquid water, an important constituent in many natural materials, such as tissue, has a low absorption at such wavelengths, allowing propagation. Polystyrene foam, wood, fruits, food-stuffs, pharmaceutical tablets, and human sinus cavities have been studied. Transport of gas in porous media can readily be studied by first immersing the material in, e.g., pure nitrogen, and then observing the rate at which normal air, containing oxygen, reinvades the material. The conductance of the sinus connective passages can be measured in this way by flushing the nasal cavity with nitrogen. Also other dynamic processes such as drying of materials can be studied. The techniques have also been extended to remote-sensing applications (LIDAR-GASMAS).","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131096347","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Formation of deep acceptor centers in AlGaN alloys AlGaN合金中深层受体中心的形成
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.816864
L. Dimitrocenko, J. Grube, P. Kulis, A. Sarakovskis, M. Spriņģis, I. Tale
{"title":"Formation of deep acceptor centers in AlGaN alloys","authors":"L. Dimitrocenko, J. Grube, P. Kulis, A. Sarakovskis, M. Spriņģis, I. Tale","doi":"10.1117/12.816864","DOIUrl":"https://doi.org/10.1117/12.816864","url":null,"abstract":"AlGaN alloy thin film materials are of high interest for light emitting diodes (LED of the ultraviolet (UV) spectral region. Origin of the deep intrinsic and impurity Si states in the AlxGa1-xN (0 < x < 0.35) epilayer structures grown by metalorganic chemical vapor deposition (MOCVD) technique have been considered. Effects of the lattice mismatch and Si-doping in the heterostructures of epilayers with different alloy composition are investigated using time resolved photoluminescence (PL) of donor - deep acceptor (DA) pairs. It is shown that the undoped AlGaN alloys, grown on a GaN buffer layer, due to the lattice mismatch contain the increased concentration of cation vacancy (Vcation) defects acting as a deep acceptor centers and responsible for PL. Si-doping results in both the additional increase of Vcation concentration and the formation in cation sub lattice of new (VcationSication) deep acceptor complexes. It is shown that by increase of the Al content in the AlGaN alloy the composition disorder of both deep acceptor centers Vcation and (VcationSication) complex appears. The corresponding broad PL bands are resolved in number of subbands. It is stated that deposition of Si-doped AlGaN alloy on undoped GaN results in formation of Si-doped GaN interlayer.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115077019","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Formation of SiC - like layers on Si surface in contact with C6H5CH3 solution by UV laser irradiation 紫外激光辐照与C6H5CH3溶液接触的Si表面形成类SiC层
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815452
M. Yusupov, L. Fedorenko, O. Lytvyn, V. Yukhimchuk
{"title":"Formation of SiC - like layers on Si surface in contact with C6H5CH3 solution by UV laser irradiation","authors":"M. Yusupov, L. Fedorenko, O. Lytvyn, V. Yukhimchuk","doi":"10.1117/12.815452","DOIUrl":"https://doi.org/10.1117/12.815452","url":null,"abstract":"The review of results of submicron surface layers formation is presented under ultraviolet (UV) N2 - laser (λ = 0.337 μm, tp = 5 ns) ablation of silicon target in liquid environment C6H5CH3. The morphological and deformation state of a near-surface Si layer was investigated by polarization modulation spectroscopy (PMS), atom force microscopy (AFM) and Raman spectra methods before and after irradiation. After irradiation AFM data shows the formation of submicron structures with hexagonal-like type of regularity on Si surface, PMS spectra indicates the increasing of refractive index, Raman spectroscopy reveals the broad band in the range 740-800 cm-1. All that facts allow us to assume the possibility of SiC-like layer formation on silicon monocrystal surface by laser stimulated diffusion of carbon atoms from liquid media. The surface morphology and composition of the irradiated surface varies considerable with the number of laser shots.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117023566","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Characterizing semiconductor materials with terahertz radiation pulses 用太赫兹辐射脉冲表征半导体材料
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.816869
A. Krotkus, R. Adomavičius, V. Pačebutas
{"title":"Characterizing semiconductor materials with terahertz radiation pulses","authors":"A. Krotkus, R. Adomavičius, V. Pačebutas","doi":"10.1117/12.816869","DOIUrl":"https://doi.org/10.1117/12.816869","url":null,"abstract":"Experimental techniques that exploit pulses of the electromagnetic radiation with characteristic spectra covering the frequency range between few hundreds GHz and few THz and their applications in the characterization of various semiconductor materials are reviewed. The list of material parameters that can be determined by using pulsed THz techniques includes, among other, carrier lifetimes, their energy and momentum relaxation times, inter-valley separation in the conduction band, and nonlinear optical susceptibilities of the material.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116486268","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Factors affecting intraocular light scattering from different color straylight sources 不同颜色杂散光源影响眼内光散射的因素
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815622
G. Ikaunieks, M. Ozolinsh
{"title":"Factors affecting intraocular light scattering from different color straylight sources","authors":"G. Ikaunieks, M. Ozolinsh","doi":"10.1117/12.815622","DOIUrl":"https://doi.org/10.1117/12.815622","url":null,"abstract":"Important optical parameter of the eye is intraocular light scattering. Straylight can reduce visual acuity, contrast sensitivity. It is one of the main factors for glare, especially for drivers at night, when there is light source some distance away from the fixation point. There are many factors, which can affect amount of light scattering in the eye. To assess the effect of the color of the straylight source on retinal image quality at different light scattering levels, retinal straylight was measured with and without light scattering occluder. Red, green and blue colors were choosed for straylight source. Psychophysical and electrophysiological methods were used to evaluate light scattering effect on perception on different color stimuli. Results show that straylight values are the greatest for blue color with and without light scattering occluder. In measurements without light scattering occluder ratio of straylight values for red and green color are different between subjects. Using light scattering occluder straylight values for green color are greater than for red color. Optical and anatomical factors which can induce these spectral variations are discussed. Psychophysical and electrophysiological methods showed the similar changes in results with straylight values when light scattering were increased.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129190908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Fiber-optic biosensor based on self-mixing interferometry 基于自混合干涉测量的光纤生物传感器
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815269
Miia Määttälä, J. Lauri, M. Kinnunen, J. Hast, R. Myllylä
{"title":"Fiber-optic biosensor based on self-mixing interferometry","authors":"Miia Määttälä, J. Lauri, M. Kinnunen, J. Hast, R. Myllylä","doi":"10.1117/12.815269","DOIUrl":"https://doi.org/10.1117/12.815269","url":null,"abstract":"Self-mixing interferometry is a promising technique for a variety of measurement applications. Using a laser diode with an external cavity as interferometer, the technique offers several advantages over traditional interferometric configurations. This research used a self-mixing interferometer built in our own laboratory. It is based on a blue emitting GaN laser diode with a wavelength of 405 nm. Light is directed through an optical fiber from which a 1-cm section of cladding has been removed, and a cuvette for holding the sample is fixed around this part. Interference patterns, created in the laser cavity, are acquired with a computer-based data acquisition system and later processed using Matlab software. Since samples with different refractive indices create interference patterns with different phases, even small changes in sample concentrations can be measured. However, coupling light into a single-mode optical fiber is a very challenging task, and the setup is very sensitive to external interference like airflows or vibrations. Experiments with the device showed that, in stability measurements, the standard deviation of the recorded fringe pattern shifts was only 1.7 nm. In sample measurements, the refractive index change in the sample chamber varied from 1.0029 to 1.33, corresponding to a fringe pattern shift of 297±4 nm.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"102 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121697221","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Pulsed photoacoustic measurements of suspensions: in case study of mitochnodrial NADH and its phantom 悬浮液的脉冲光声测量:在线粒体NADH及其幻影的案例研究中
International Conference on Advanced Optical Materials and Devices Pub Date : 2008-09-10 DOI: 10.1117/12.815279
Zuomin Zhao, J. Hast, R. Myllylä, M. Känsäkoski
{"title":"Pulsed photoacoustic measurements of suspensions: in case study of mitochnodrial NADH and its phantom","authors":"Zuomin Zhao, J. Hast, R. Myllylä, M. Känsäkoski","doi":"10.1117/12.815279","DOIUrl":"https://doi.org/10.1117/12.815279","url":null,"abstract":"The laser photoacoustic spectroscopy (LPAS) can be applied analytically to determine the concentration of an analyte in samples and its absorption variation as a function of time. The LPAS has advantages of higher detection sensitivity, pure absorption measurement and much less interference by background scattering in comparison with traditional optical spectroscopy. On the other hand, the apparatus is simpler and more generally useful than that of fluorescent spectroscopy. In this study, we built a photoacoustic setup of a Q-switched Nd:YAG laser excited at the third harmonic wavelength and a wideband piezoelectric transducer clamped to the side of a cuvette. The samples included NADH solutions, mitochondrial suspensions and Intralipid-ink mixtures. The experiment results show that the lowest detectable absorption of the setup is in the order of 10-5 cm-1; the detectable concentration of NADH in a buffer is as low as 1.67 μM. When monitoring mitochondrial suspensions, the minimal concentration that can be detected is lower than 0.1 mg/mL and the absorption variation caused by full reduction of NAD+ to NADH in mitochondria can be detected.","PeriodicalId":273853,"journal":{"name":"International Conference on Advanced Optical Materials and Devices","volume":"133 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122490783","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信