Electric Machines and Power Systems最新文献

筛选
英文 中文
Comparison Studies of Unified Power Flow Controllers with Static Var Compensators and Phase Shifters 带静态无功补偿器和移相器的统一潮流控制器的比较研究
Electric Machines and Power Systems Pub Date : 1999-02-01 DOI: 10.1080/073135699269271
J. Y. Liu, Y. Song
{"title":"Comparison Studies of Unified Power Flow Controllers with Static Var Compensators and Phase Shifters","authors":"J. Y. Liu, Y. Song","doi":"10.1080/073135699269271","DOIUrl":"https://doi.org/10.1080/073135699269271","url":null,"abstract":"This paper reports on the comparison of ratings and control flexibility of three major FACTS devices. The locations of UPFC installation is determined by 'contingency analysis.' After power flow modelling of SVC, PS, and UPFC is introduced, a new power flow control method for UPFC is described. Four practical indices are used to evaluate the behavior of power systems. The test results on a test network clearly illustrate the effectiveness of the proposed approach.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132565955","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Corrective Schemes for Voltage Stability Using Two Different Indicators 使用两种不同指标的电压稳定性校正方案
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269343
I. Habiballah, C. Belhadj
{"title":"Corrective Schemes for Voltage Stability Using Two Different Indicators","authors":"I. Habiballah, C. Belhadj","doi":"10.1080/073135699269343","DOIUrl":"https://doi.org/10.1080/073135699269343","url":null,"abstract":"This paper discusses the steady state voltage stability analysis of two power systems: Wale and Hale 6-bus system and the IEEE 30-bus system by using four different correction schemes: transmission path, reactive compensation, generation voltage and reactive path, and load shedding. These correction schemes can improve voltage stability with the help of two indicator techniques: L-index value and V-Q sensitivity value. Results of tests carried on the above-mentioned systems are provided and discussed.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"90 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134044468","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Power Network Topology Recognition Using Neural Networks 基于神经网络的电力网络拓扑识别
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269398
Mohamed Abd-El-Aal Abd-El-Reheim
{"title":"Power Network Topology Recognition Using Neural Networks","authors":"Mohamed Abd-El-Aal Abd-El-Reheim","doi":"10.1080/073135699269398","DOIUrl":"https://doi.org/10.1080/073135699269398","url":null,"abstract":"A pattern recognition application, using artificial neural networks (ANN), may be categorized as the largest category that covers the use of a neural networks for classifications. It is proved that ANNs are excellent for the applications of complex pattern recognition such as visual images of objects, speech recognition, printed or handwritten characters, and many other types of pattern recognition. Such wide applications are developed, based on the major advantage of the neural networks of being inherently error tolerant, i.e., it can solve problems adequately with information (data) that is uncertain, incomplete, or noisy. The reliable results of the power system security and economical analysis depend on the supply of real-time data base, results of power system state estimation, programs whose major problem is the determination of the network topology configuration. The determination of the topology suffers from the uncertainty of the collected data related to the circuit breakers status, due to the p...","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"125 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117032496","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
A Fuzzy Logic Based Current Modulator for Torque Ripple Minimization in Switched Reluctance Motors 基于模糊逻辑的开关磁阻电机转矩纹波最小化电流调制器
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269389
N. Sahoo, S. K. Panda, P. Dash
{"title":"A Fuzzy Logic Based Current Modulator for Torque Ripple Minimization in Switched Reluctance Motors","authors":"N. Sahoo, S. K. Panda, P. Dash","doi":"10.1080/073135699269389","DOIUrl":"https://doi.org/10.1080/073135699269389","url":null,"abstract":"This paper addresses a fundamental control issue in switched reluctance motor (SRM) drives-the torque ripples. Conventionally, the amplitude of the rectangular reference current pulse, on-angle, and off-angle for the various phases of the SRM for a given torque demand are obtained from a stored look-up table that makes use of measured torque-current-position characteristics. However, the electromagnetic torque, thus obtained, contains significant ripples. A number of techniques for the generation of reference current profiles that minimize the torque ripples have also been suggested in the past. But due to highly nonlinear characteristics of the SRM, all these schemes are not fully successful. Moreover, their performance depends greatly on the accuracy of the magnetic characteristics measurements of the motor on which most of these algorithms work. Our work is primarily motivated to modulate the reference phase current pattern with the aid of fuzzy logic which is well suited to compensate for the nonlinea...","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124620129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Modelling and Identification of Parameters of Saturated Induction Machine Operating Under Motor and Generator Conditions 饱和感应电机在电机和发电机工况下的建模与参数辨识
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269334
P. Lagonotte, H. Miah, M. Poloujadoff
{"title":"Modelling and Identification of Parameters of Saturated Induction Machine Operating Under Motor and Generator Conditions","authors":"P. Lagonotte, H. Miah, M. Poloujadoff","doi":"10.1080/073135699269334","DOIUrl":"https://doi.org/10.1080/073135699269334","url":null,"abstract":"This work presents modelling and parameters identification of a saturated induction machine. Different algorithms of nonlinear optimization were used in this work. The new model which was elaborated, allows us to carry out a good parameters identification from the measurements obtained from the two modes of operating as motor and as generator. This model has two different saturation reactances. One can be identified from motor and the other from generator operation. An interpretation of the reactance saturation is done.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122012873","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Integrated Direct Methods for Transient Stability Analysis 暂态稳定分析的综合直接方法
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269352
Y. Song, L. Yao, Y. Ni, P. Mao
{"title":"Integrated Direct Methods for Transient Stability Analysis","authors":"Y. Song, L. Yao, Y. Ni, P. Mao","doi":"10.1080/073135699269352","DOIUrl":"https://doi.org/10.1080/073135699269352","url":null,"abstract":"In this paper, three direct methods (i.e., Controlling Unstable Equilibrium Point (CUEP) method, Potential Energy Boundary Surface (PEBS) method, and Extended Equal Area Criterion (EEAC) method) for power system transient stability analysis have been reviewed and compared. Their analysis accuracy and their error sources are investigated. Then, an integrated direct method with much higher accuracy and reliability is proposed. The proposed method has been applied to two Chinese power systems for transient stability analysis of more than two thousand cases under large disturbances of symmetrical and unsymmetrical faults and autoreclosure operating sequence disturbances. Statistical results clearly illustrate the effectiveness of the proposed method.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114397715","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Operational Aspects of Self-Excited Induction Generator Using a New Model 基于新模型的自激感应发电机的运行问题
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269370
K. Sandhu, S. Jain
{"title":"Operational Aspects of Self-Excited Induction Generator Using a New Model","authors":"K. Sandhu, S. Jain","doi":"10.1080/073135699269370","DOIUrl":"https://doi.org/10.1080/073135699269370","url":null,"abstract":"This paper presents a new approach to analyze the operation of a self-excited induction generator operating under steady-state conditions. The proposed approach when applied leads to quadratic equation in slip, which makes the analysis and physical interpretation of performance simple, explicit, and comprehensive. The theoretical results obtained from the proposed model have been verified experimentally under different operating conditions.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128468213","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 43
Large Power Systems Stability Enhancement Using a Delayed Operation Fuzzy Logic Power System Stabilizer 基于延迟运行模糊逻辑电力系统稳定器的大型电力系统稳定性增强
Electric Machines and Power Systems Pub Date : 1999-01-15 DOI: 10.1080/073135699269361
S. Gawish, F. Khalifa, W. Sabry, M. Badr
{"title":"Large Power Systems Stability Enhancement Using a Delayed Operation Fuzzy Logic Power System Stabilizer","authors":"S. Gawish, F. Khalifa, W. Sabry, M. Badr","doi":"10.1080/073135699269361","DOIUrl":"https://doi.org/10.1080/073135699269361","url":null,"abstract":"This paper presents a novel control operation of fuzzy logic power system stabilizer (FLPSS) for stability enhancement of a large-scale power system. The FLPSS is applied for each machine in the system while its operation is delayed for a short period almost equal to the first half cycle of the power system electromechanical oscillations. The application of this controller is successful in damping large-scale power system oscillations. In order to accomplish best damping characteristics, two signals are chosen as inputs to the FLPSS; deviation of power angle (Delta 6) and deviation of speed derivative (Delta) of each omega synchronous machine in the system. These two variables have efficient effects on damping the oscillations of both frequency and terminal voltage signals and hence the system gives better stability. The effectiveness of this delayed operation FLPSS controller is demonstrated by a digital computer simulation of a large-scale power system.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1999-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126483779","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
OPTIMIZATION OF AN ELECTRONICALLY CONTROLLED CAPACITOR FOR A SINGLE-PHASE INDUCTION MOTOR 单相感应电动机电子控制电容器的优化设计
Electric Machines and Power Systems Pub Date : 1998-12-01 DOI: 10.1080/07313569808955878
J. Faiz, A. Servatian, P. Pillay
{"title":"OPTIMIZATION OF AN ELECTRONICALLY CONTROLLED CAPACITOR FOR A SINGLE-PHASE INDUCTION MOTOR","authors":"J. Faiz, A. Servatian, P. Pillay","doi":"10.1080/07313569808955878","DOIUrl":"https://doi.org/10.1080/07313569808955878","url":null,"abstract":"ABSTRACT In this paper the performance of a single-phase induction motor with an electronically controlled capacitor is examined. The capacitor in series with the auxiliary winding is controlled with an electronic circuit and different optimization criteria are applied in order to determine the optimum capacitance of subsequent performance of the motor.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126605773","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
PATTERN RECOGNITION TECHNIQUE FOR TRAVELLING WAVE PROTECTION 行波保护的模式识别技术
Electric Machines and Power Systems Pub Date : 1998-12-01 DOI: 10.1080/07313569808955873
Jie Lang, S. Elangovan, J. Devotta
{"title":"PATTERN RECOGNITION TECHNIQUE FOR TRAVELLING WAVE PROTECTION","authors":"Jie Lang, S. Elangovan, J. Devotta","doi":"10.1080/07313569808955873","DOIUrl":"https://doi.org/10.1080/07313569808955873","url":null,"abstract":"ABSTRACT Most of the travelling wave protection algorithms use correlation function method. For high impedance fault (HIF) and some system configurations, it can not perform well. In this paper, the pattern recognition technique is adopted to collaborate with the correlation function method. The new algorithm has better peak intensity, which improves its discrimination ability significantly. Further simplification is acquired due to its independence of the system configuration and fault types.","PeriodicalId":262115,"journal":{"name":"Electric Machines and Power Systems","volume":"76 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131894404","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书