Dong Wang, Li Zhang, Chong Wang, Shengchao Liu, Qi Liu
{"title":"A Harmonic Detection Strategy Based on FBD Power Theory","authors":"Dong Wang, Li Zhang, Chong Wang, Shengchao Liu, Qi Liu","doi":"10.1109/APPEEC45492.2019.8994402","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994402","url":null,"abstract":"The stability, safety and economic operation of the power system are threated by harmonic pollution. Moreover, a series of harmonic currents and unbalanced load currents are affecting the power quality seriously. The active power filter is mainly used to compensate the harmonic current. However, the compensation effect is affected by the dynamic response speed of harmonic current detection. In this paper, the FBD(Fryze-Buchholz-Dpenbrock) theory and its derived harmonic detection method, and the deficiency in dynamic response of the low-pass filter and the Moving Average Filter (MAF) are introduced and analysied, respectivly. Then, an improved Generalized Moving Average Filter (GMAF) is proposed to improve the dynamic response speed of harmonic detection. Finally, based on FBD power theory, a single-phase and three-phase simulation model is built in MATLAB/Simulink, and the simulation results of two methods under steady state and load current mutation are given, and the characteristics of GMAF’s dynamic response speed are verified.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"136 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124240786","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Wentao Liu, Li Li, Jianguo Zhou, Yinliang Xu, Zhongkai Yi
{"title":"Robust Distributed Optimal Energy Management for Multi-Energy Networked Microgrids","authors":"Wentao Liu, Li Li, Jianguo Zhou, Yinliang Xu, Zhongkai Yi","doi":"10.1109/APPEEC45492.2019.8994325","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994325","url":null,"abstract":"This paper investigates the day-ahead optimal energy management issue of networked microgrids with the consideration of multi-energy within each microgrid. Uncertainty, a ubiquitous and challenging problem in the high penetrated renewable energy system, is considered in the microgrid system. Also, the security constraints of the energy transmission between microgrids are introduced. The objective of the networked microgrids is to maximize the day-ahead social welfare by cooperating with each other. To this end, the problem is formulated as a class of robust distributed coupled optimization problem. Following, an affinely adjustable-based robust distributed optimization method with event-triggered communication is proposed to address this issue. With the effort, each microgrid can determine its owing optimal operations through only local communication and computation, resulting in enhanced system reliability, scalability, and privacy, and as well as reduced communication. Simulations are provided to verify the effectiveness of the proposed method.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123467410","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Control Strategy to Smooth Wind Power Fluctuations of PMSG Wind Turbine based on the Secondary Exponential Moving Average Method","authors":"Yang Zhou, Lihui Yang","doi":"10.1109/APPEEC45492.2019.8994429","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994429","url":null,"abstract":"In this paper, a novel power smoothing control strategy for permanent magnet synchronous generator (PMSG) wind turbine (WT) based on the secondary exponential moving average method is proposed by the rotor kinetic energy control and the pitch angle control. The method is proposed considering its advantage of reducing the hysteresis between the calculated value and the actual value, which can consequently reduce the power loss when smoothing the power fluctuation. The simulations have been carried out in Matlab/Simulink environment for PMSG WT system to verify the effectiveness of the proposed method. Compared with the first exponential moving average method, the performance of the proposed method exhibits that the power smoothing control can be achieved and the wind energy harvesting is enhanced as well.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"49 9-10","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120894231","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Discussion about Recent Applications of Power Big Data in Smart Grid","authors":"Jia Zhen, Ning Qiang, Li Liu, Qiling Hou","doi":"10.1109/APPEEC45492.2019.8994522","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994522","url":null,"abstract":"Smart grid is one of the most important application situations for big data. The application of cloud computing technology as the core of large data technology has become an inevitable choice for the development of current and future power enterprises. Based on the data acquisition architecture of smart grid, this paper enumerates the application cases of big data technology in the process of smart grid construction, such as transmission line disaster prevention and early warning, equipment operation status assessment, active service of key customers, cracking down on breach of contract stealing and visualization display, etc. This paper has summarized the key technologies of big data and research ideas and discussed the problem of big data technology in smart grid. At the end of the paper, a rational prospect for the development of big data technology in smart grid has been explored.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121216030","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Graef, M. Menge, V. Platonov, Moritz Kölling, Tamara Meinl, Hochschule für Technik, Wirtschaft Berlin
{"title":"Application of Fiber Optic Sensor Systems for Acoustic And Optical Monitoring Of Transmission Systems And Switchgear","authors":"T. Graef, M. Menge, V. Platonov, Moritz Kölling, Tamara Meinl, Hochschule für Technik, Wirtschaft Berlin","doi":"10.1109/APPEEC45492.2019.8994764","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994764","url":null,"abstract":"The ongoing energy transition away from conventional energy generation to renewable energies demands for long distance connections with transmission lines and high energy cables. To reduce the risk of failures and outages the use of modern sensor and monitoring systems forces the implementation of fiber optic sensor systems. Fiber optic sensor systems are presented for the detection of acoustic partial discharges at cable connectors, switchgear and high energy transmission systems. Similar technology is used to assess the condition of circuit breaker. An additional application for photonic detection of partial discharges is shown too by the use of a photon sensitive fiber. Signal processing is applied for automated identification of defined patterns to separate partial discharges from noise for online monitoring as well as condition monitoring of circuit breaker based on acoustical analysis. All these modern techniques are presented for the use at energy transmission and distribution equipment.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114205722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An Adaptive Ramp-Rate Control for Photovoltaic System to Mitigate Output Fluctuation","authors":"Qixiang Xu, H. Wen, Yinxiao Zhu, Xingshuo Li","doi":"10.1109/APPEEC45492.2019.8994617","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994617","url":null,"abstract":"With high penetration level of grid-connected photovoltaic (PV) system, the stability of power grid is easily affected by the variable irradiation which furthers the power fluctuations with high ramp-rate. Hence, in order to extent the proportion of solar energy in power grid, a method for controlling ramp-rate is necessary to be installed in PV system. Normally, energy storage system (ESS) is employed without a direct control and controllable ramp-rate in prior-arts. Meanwhile, the state of charge (SoC) of ESS could also influence the fluctuation mitigation performance. In this paper, an adaptive ramp-rate control is proposed with integrated ESS for fluctuation mitigation. This control blends a direct ramp-rate control to reduce the fluctuation caused by PV side irradiation change to a desired level and a SoC control with variable ramp-rate to improve the performance in unexceptional SoC. The proposed control is verified by the simulations based on a typical PV micro-grid with ESS.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114794070","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Frequency Vulnerability Analysis of Power Systems Considering UAV Striking","authors":"Wenjun Bi, Kaifeng Zhang, Ying Wang, Zhetong Ding","doi":"10.1109/APPEEC45492.2019.8994667","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994667","url":null,"abstract":"A novel Unmanned Aerial Vehicle (UAV) striking method on system frequency of power systems is discussed in this paper. Typical characteristics of UAV attack on power grids are analyzed and summarized in five aspects: difficult to be detected, hard to be foiled, nonsensitive, clustered and precise. To illustrate the feasibility of UAV attack, UAV short-circuit attack mode is proposed as an effective way to attack against the grid. We analyze the feasibility of UAV short-circuit attack mode by establishing a mathematical model, and verify the feasibility based on various short-circuit materials. UAV frequency attack strategies are discussed to show the severe damage inflicted by UAV attack. Among them, Multipoint Multistage Attack (MMA) strategy can result in rapid collapse of the frequency by implementing a series of attacks precisely. Compared to Multipoint Simultaneous Attack (MSA) strategy, the MMA strategy can utilize both the characteristics of UAVs and vulnerability of system frequency. The proposed strategies are evaluated by a dynamic frequency simulation model. Simulation results show the effectiveness and advantages of the UAV frequency attack strategy.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128061633","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ming Yan, Zheren Zhang, Zheng Xu, Ling-Yun Chen, G. Cheng, Qiongfang Wang
{"title":"Comparative study on DC line fault transient characteristics of four typical MMC-HVDC configurations","authors":"Ming Yan, Zheren Zhang, Zheng Xu, Ling-Yun Chen, G. Cheng, Qiongfang Wang","doi":"10.1109/APPEEC45492.2019.8994581","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994581","url":null,"abstract":"DC faults can cause serious problems such as power outage or even damaging the electrical equipment. The aim of this paper is to compare four DC fault clearance schemes in modular multilevel converter based high voltage direct current (MMC-HVDC) systems. Firstly, this paper summarizes four typical DC fault handling configurations including the DC circuit breaker (DCCB), the hybrid MMC with full bridge submodules and half bridge submodules (FHMMC), the LCC-MMC hybrid configuration with diode groups installed in the DC line close to the converters (LCCD-MMC) and the hybrid topology with an LCC and an MMC in series-connection. Then the basic structures and DC fault clearance schemes of the four configurations are discussed. Finally, a three-terminal simulation system is established to compare the DC line fault transient characteristics of the four MMC-HVDC configurations. The simulation result shows that the DCCBs perform the best DC fault clearance characteristics. Considering the cost efficiency and operation flexibility, the LCC-MMC hybrid topology has certain value of practical application in engineering.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128116548","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Research on Uninterrupted Phase-Separation Passing Device Based on Three-Phase MMC","authors":"Zhou Ni, Feiran Xiao, Jiaxin Yuan, Yanming Ke","doi":"10.1109/APPEEC45492.2019.8994653","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994653","url":null,"abstract":"When the high-speed train passes through the neutral section, it will lose power supply and rely on inertia taxiing to pass, resulting in greatly reduced speed and serious energy loss. A three-phase MMC-based continuous-current phase-separation passing topology is presented in this paper, which can be directly connected to 27.5 traction power supply system without using transformers. The three lead-out terminals of three-phase MMC are connected to the traction power supply arms on both sides and the neutral section respectively, which can effectively ensure that the locomotive obtains the energy of linear change from the traction power supply arms on both sides during the process of passing through the neutral section, and ensure that the locomotive’s load changes linearly without sudden change while passing through the neutral section Uninterruptedly, thus avoiding the reduction of locomotive’s speed. Finally, the effectiveness of the device is verified by the simulation of MATLAB.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125655953","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Man Chen, Dinglin Li, Shu Zhu, Xingzheng Feng, Kaipei Liu
{"title":"Influence of Parameters Non-uniformity on Inverters Dynamic Equivalent Error","authors":"Man Chen, Dinglin Li, Shu Zhu, Xingzheng Feng, Kaipei Liu","doi":"10.1109/APPEEC45492.2019.8994712","DOIUrl":"https://doi.org/10.1109/APPEEC45492.2019.8994712","url":null,"abstract":"The influence of parameters non-uniformity including various controller, power levels and network parameters on multiple grid-connected inverters dynamic equivalent error are investigated. The error is divided into two parts. One part is caused by the inconsistent recovery time of inverters at different power levels during low voltage ride-through (LVRT), and the other is attributed to the different dominant dynamics of the inverters. According to these two sources of error, a two-step clustering method is proposed and implemented in a 36-inverter system. The simulation results show that this method has higher precision in different scenarios, but it is accompanied with the sacrifice of simulation speed. Then, the simulations of a 6-bus system show that the error of the single inverter equivalence become large when crowbar acts, and the impact of the first type of error is significantly greater than the second one.","PeriodicalId":241317,"journal":{"name":"2019 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121957143","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}