TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference最新文献

筛选
英文 中文
The Influence of Physical Cell Parameters on Projection Cytometer Measurements 物理细胞参数对投影细胞仪测量结果的影响
S. Kostner, M. Vellekoop
{"title":"The Influence of Physical Cell Parameters on Projection Cytometer Measurements","authors":"S. Kostner, M. Vellekoop","doi":"10.1109/SENSOR.2007.4300512","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300512","url":null,"abstract":"In this paper the influence of optical absorption on projection cytometer measurements is discussed. Projection cytometry is an optical method for measuring physical parameters of biological cells in the optical near field. For reliable results, it is crucial to keep the projection distance constant for consecutive measurements which is achieved by applying a non-coaxial sheath flow. Simulations have been performed to predict the sensor signal for different absorption coefficients inside a cell. The interesting result is that with changing absorption coefficient only a part of the signal shape changes which indicates the ability to extract this parameter from the shape of the signal.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"25 1","pages":"1833-1836"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91531585","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reinforced Pressure Sensor for Marine Environment 海洋环境用加强型压力传感器
S. Aravamudhan, S. Bhansali
{"title":"Reinforced Pressure Sensor for Marine Environment","authors":"S. Aravamudhan, S. Bhansali","doi":"10.1109/SENSOR.2007.4300615","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300615","url":null,"abstract":"Pressure measurements in marine environment are of utmost importance to better understand the ocean processes, for maritime security and even for tsunami wave detection. In this work, a MEMS reinforced piezoresistive pressure sensor with packaging and protective coatings was tested to achieve both higher sensitivity and larger full scale span compared to conventional single diaphragm. By eliminating large deflections and non-linearities, the reinforced design showed about 15% higher sensitivity and twice the operating range. Further, reliability of protective coatings was evaluated in real ocean conditions.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"9 1","pages":"2243-2246"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90132940","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Photosensitive Poly(Dimethylsiloxane) (Photopdms) for Rapid and Simple Polymer Fabrication 用于快速和简单聚合物制备的光敏聚二甲基硅氧烷(Photopdms)
A. Bhagat, P. Jothimuthu, I. Papautsky
{"title":"Photosensitive Poly(Dimethylsiloxane) (Photopdms) for Rapid and Simple Polymer Fabrication","authors":"A. Bhagat, P. Jothimuthu, I. Papautsky","doi":"10.1109/SENSOR.2007.4300186","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300186","url":null,"abstract":"In this paper, we report a new and simple method of patterning polydimethylsiloxane (PDMS) directly under normal ambient light for rapid prototyping of disposable microfluidic lab-on-a-chips (LOCs). The photodefinable PDMS (photoPDMS) is positive-acting and only sensitive to light below 365 nm, which permits processing outside a gold room. A parametric study was conducted to optimize this novel fabrication technique. Features as small as 100 mum were successfully fabricated using photoPDMS. To further demonstrate the potential of this novel technique, thin (< 30 mum) free-standing patterned PDMS films. Successful demonstration of this novel process presents a feasibly simpler alternative approach for rapid prototyping of disposable microfluidic biochips for lab-on-a-chip applications.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"66 1","pages":"537-540"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80705556","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A Low-Loss Single-Pole-Double-Throw (SPDT) Switch Circuit 一种低损耗单极双掷开关电路
M. Tang, A. Liu, A. Agarwal
{"title":"A Low-Loss Single-Pole-Double-Throw (SPDT) Switch Circuit","authors":"M. Tang, A. Liu, A. Agarwal","doi":"10.1109/SENSOR.2007.4300221","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300221","url":null,"abstract":"A low-loss single-pole-double-throw (SPDT) switch circuit using lateral RF MEMS switches has been developed on glass to operate from DC to 20 GHz. High compactness and low loss can be obtained by use of the lateral switches and coplanar waveguide (CPW) configuration. The circuit provides > 24-dB isolation and < 0.9-dB insertion loss up to 20 GHz. The pull-in voltage of the switch is only 12.4 V, with a switching-on time of 35 mus and a switching-off time of 36 mus. A single-mask silicon-on-glass (SiOG) fabrication process has been developed to fabricate the SPDT switch circuit on glass, which has the advantages of low loss and high yield. The whole circuit has a size of 1.64 mm times 1.3 mm.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"42 1","pages":"679-682"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"80737176","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A Microfluidic Oxygenator for Biological Cell Culture 生物细胞培养用微流控充氧器
R. Lam, Min-Cheol Kim, T. Thorsen
{"title":"A Microfluidic Oxygenator for Biological Cell Culture","authors":"R. Lam, Min-Cheol Kim, T. Thorsen","doi":"10.1109/SENSOR.2007.4300676","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300676","url":null,"abstract":"In this paper, we report on the development of a microfluidic platform in which dissolved oxygen (DO) concentrations can be dynamically adjusted for cell culture applications. The DO concentration in culture media flowing through enclosed microchannels is regulated by the diffusion through an elastromeric interface from an overhead gas channel, using an oxygen-sensitive dye embedded in the fluid channel as a sensor. Using a microchannel network functioning as an oxygen/nitrogen mixer, the growth characteristics of murine fibroblast cells (3T3) were analyzed as a function of eight discrete DO concentrations in culture media within a single device, ranging from anaerobic (0 ppm) to fully saturated (42 ppm).","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"52 4 1","pages":"2489-2492"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79716811","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Effect of Electrode Configuration on the Frequency and Quality Factor Repeatability of RF Micromechanical Disk Resonators 电极结构对射频微机械圆盘谐振器频率和质量因数重复性的影响
Yang Lin, Jing Wang, S. Pietrangelo, Z. Ren, Clark T.-C. Nguyen
{"title":"Effect of Electrode Configuration on the Frequency and Quality Factor Repeatability of RF Micromechanical Disk Resonators","authors":"Yang Lin, Jing Wang, S. Pietrangelo, Z. Ren, Clark T.-C. Nguyen","doi":"10.1109/SENSOR.2007.4300669","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300669","url":null,"abstract":"A statistical evaluation of the standard deviations of the resonance frequencies and quality factors of polysilicon surface-micromachined micromechanical disk resonators with fully-surrounding and split electrode configurations has been conducted by fabricating and measuring a large quantity (>400) of devices. Through this analysis, respective single-wafer resonance frequency standard deviations as low as 642 ppm for fully-surrounding electrode devices; and 984 ppm for two-port split electrode devices; have been measured. Respective average quality factor standard deviations for fully surrounding electrode devices of 5.6% in vacuum; and 3.9% in air; have also been obtained. The standard deviations for both frequency and Q of each resonator type are well within values needed to achieve the -3% percent bandwidth requirements for filters presently used in the RF front-ends of wireless communication devices without trimming.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"25 1","pages":"2461-2464"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83382902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Performances of a Newly High Sensitive Trilayer F/CU/F GMI Sensor 一种新型高灵敏度三层F/CU/F GMI传感器的性能
F. Alves, B. Kaviraj, L. A. Rached, J. Moutoussamy, C. Coillot
{"title":"Performances of a Newly High Sensitive Trilayer F/CU/F GMI Sensor","authors":"F. Alves, B. Kaviraj, L. A. Rached, J. Moutoussamy, C. Coillot","doi":"10.1109/SENSOR.2007.4300699","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300699","url":null,"abstract":"We have selected stress-annealed nanocrystalline Fe-based ribbons for magnetic/copper/magnetic sensors exhibiting high magneto-impedance ratio. Longitudinal magneto-impedance DeltaZ/Zsat reaches 400% at 60 kHz and longitudinal magneto-resistance DeltaR/Rsat increases up to 1100% around 300 kHz.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"29 1","pages":"2581-2584"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88552311","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Micro-Ablation of Skin by Arc-Discharge Jet Ejection for Transdermal Drug Delivery 经皮给药用电弧喷射微消融皮肤
P. Gadiraju, Jung-Hwan Park, Jeong Woo Lee, M. Prausnitz, M. Allen
{"title":"Micro-Ablation of Skin by Arc-Discharge Jet Ejection for Transdermal Drug Delivery","authors":"P. Gadiraju, Jung-Hwan Park, Jeong Woo Lee, M. Prausnitz, M. Allen","doi":"10.1109/SENSOR.2007.4300541","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300541","url":null,"abstract":"This paper presents the design, fabrication and characterization of a jet ejection device that operates on the actuation principle of arc discharge for the purpose of generating micron-scale pores in skin. This thermo-mechanical micro-ablation technique increases skin permeability to drugs, while expected to maintain the patient friendliness of conventional transdermal patches. Laser micromachining and lamination techniques were utilized in fabricating these arc-discharge jet ejection devices. The released jet from the device is characterized in terms of its force, velocity and temperature and is used in skin ablation experiments. The skin is exposed to the jet and the permeability effects are characterized. Skin permeability was increased by approximately three orders of magnitude after jet exposure when compared to non-exposed controls, which is a significant advance for transdermal drug delivery.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"41 1","pages":"1947-1950"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88728081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Temperature and Trapping Characterization of an Acoustic Lateral Trap for μ TAS μ TAS声学侧阱的温度和俘获特性
L. Johansson, M. Evander, T. Lilliehorn, M. Almqvist, J. Nilsson, T. Laurell, S. Johansson
{"title":"Temperature and Trapping Characterization of an Acoustic Lateral Trap for μ TAS","authors":"L. Johansson, M. Evander, T. Lilliehorn, M. Almqvist, J. Nilsson, T. Laurell, S. Johansson","doi":"10.1109/SENSOR.2007.4300236","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300236","url":null,"abstract":"An acoustic lateral trap for application in non-contact trapping of cells or particles in a microfluidic channel in a μTAS (micro total analysis system) is characterized by temperature and trapping efficiency measurements. Temperature is measured by fluorescent response of Rhodamine B in the microchannel. Trapping efficiency is measured as the projected area of a trapped particle cluster counter-balanced by hydrodynamic force. One of the main objectives is to obtain quantitative values of the temperature in the fluidic channel to ensure safe handling of cells and proteins. Other objectives are to evaluate optimal drive parameters. The optimal frequency, when temperature and trapping is considered, was found to be the parallel resonance frequency.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"37 1","pages":"739-742"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87266355","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
6-Stage Cascade Mode Magnetophoretic Microseparator for Human Blood Cells 6级级联式人血细胞磁泳微分离器
Youngdo Jung, Yoonsu Choi, Ki-Ho Han, A. B. Frazier
{"title":"6-Stage Cascade Mode Magnetophoretic Microseparator for Human Blood Cells","authors":"Youngdo Jung, Yoonsu Choi, Ki-Ho Han, A. B. Frazier","doi":"10.1109/SENSOR.2007.4300542","DOIUrl":"https://doi.org/10.1109/SENSOR.2007.4300542","url":null,"abstract":"This paper is focused on the development of a 6-stage cascade paramagnetic mode magnetophoretic separation (PMMS) system. The design and fabrication of a 6-stage cascade mode magnetophoretic microseparator are presented along with the experimental characterization of the separation system using human whole blood as the case study. In this example, the PMMS system is used to separate blood cells from human whole blood based on their native magnetic properties using the magnetic force produced from a high magnetic field gradient. The most significant advancement of the PMMS system over our previously reported microseparators is the ability to obtain similar blood cell separation efficiencies while significantly increasing the volumetric flow rate through the separator. Experimental results show a separation efficiency of 89.5plusmn0.20 % for red blood cells at a volumetric flow rate of 28.8 muL / hr, resulting in a separation time of 10.4 minutes for a 5.0 muL blood sample.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"7 1","pages":"1951-1954"},"PeriodicalIF":0.0,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87352055","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信