Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society最新文献

筛选
英文 中文
Determination of three-dimensional torso, heart and electrode geometries from magnetic resonance images 从磁共振图像中测定三维躯干、心脏和电极几何形状
P. Ershler, R. Lux, L. Green, G. Caputo, D. Parker
{"title":"Determination of three-dimensional torso, heart and electrode geometries from magnetic resonance images","authors":"P. Ershler, R. Lux, L. Green, G. Caputo, D. Parker","doi":"10.1109/IEMBS.1988.94436","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94436","url":null,"abstract":"ECG (electrocardiogram) inverse solutions require accurate determination of three-dimensional torso, heart, and electrode geometries. Magnetic resonance imaging (MRI) provides a noninvasive method for obtaining this information. Subjects initially undergo body surface potential mapping using a 195-channel data recording system. Limitations imposed by the intense magnetic field of the imaging system require that the metallic recording electrodes be replaced with nonmetallic oil-filled phantom electrodes. These are easily delineated in the MRI images. Transverse MRI sections of the subject are imaged at 10-mm intervals. Digital data representing the resulting images are transferred to a Macintosh II computer for definition of surface boundaries. This is a practical technique for obtaining geometrical data for ECG inverse solutions.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130244452","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A body surface mapping unit for recording during coronary angioplasty 冠状动脉成形术中记录的体表测绘装置
R. Macleod, B. Hoyt, J. Sherwood, P. MacInnis, R. Potter, B. Horáček
{"title":"A body surface mapping unit for recording during coronary angioplasty","authors":"R. Macleod, B. Hoyt, J. Sherwood, P. MacInnis, R. Potter, B. Horáček","doi":"10.1109/IEMBS.1988.94424","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94424","url":null,"abstract":"A low-noise multichannel recording system for simultaneously registering up to 256 ECG (electrocardiogram) signals in digital form is described. The unit's features include: patient isolation and radiolucent electrodes required for use during cardiac catherization and angioplasty procedures; continuous data collection over several minutes; gain and sampling frequency under software control; and flexible, modular design. The mapping system consists of three physically separate units: the bedside unit, the controller and communications interface, and the computer. The method chosen to ensure adequate patient isolation and still maintain sufficient sensitivity and signal/noise characteristics is to isolate the entire input stage of the recording system and power it with rechargeable batteries.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124175772","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Electrophysiologic depression in myocardium by defibrillation-level shocks 除颤水平电击引起的心肌电生理抑制
L. Fogelson, L. Tung, N. Thakor
{"title":"Electrophysiologic depression in myocardium by defibrillation-level shocks","authors":"L. Fogelson, L. Tung, N. Thakor","doi":"10.1109/IEMBS.1988.95283","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95283","url":null,"abstract":"The authors investigated the electrophysiological consequences of high currents on isolated strips of cardiac muscle. The objective was to measure the graded changes in intracellular action potentials-amplitude, duration, excitability, conduction velocity-resulting from the various levels of electrical shock typically used in defibrillation, cardioversion, and ablation. Following the shock, reversible injury is observed, whose severity is graded in proportion to shock strength. Smaller shocks (below 500 ma/cm/sup 2/, 10 ms) caused depression in action potential amplitude, duration, and propagation velocity. The degree of depression and the time course for complete recovery (0-50-s duration), followed by an action potential recovery phase similar to that observed for the smaller shocks. These graded effects can in conjunction with the whole heart description, of the current densities during defibrillation, permit an estimation of the total volume of tissue subject to inexcitability, reduced propagation velocity, shortened duration, and depressed action potentials.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125231152","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Computer aided segmentation of high frequency echocardiographic images 高频超声心动图图像的计算机辅助分割
J. M. Bauer, N. A. Alvarez, D. McPherson, R. A. Stein
{"title":"Computer aided segmentation of high frequency echocardiographic images","authors":"J. M. Bauer, N. A. Alvarez, D. McPherson, R. A. Stein","doi":"10.1109/IEMBS.1988.94604","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94604","url":null,"abstract":"Segmentation of coronary arterial lumen and wall boundaries in high-frequency echocardiographic (HFE) images has been hampered by operator bias and prolonged time required for manual segmentation methods. To overcome these problems, a two-part computer algorithm has been developed to aid HFE image segmentation. This algorithm is accurate when compared to manual methods and histologic data.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130912677","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Metabolic system identification using simulation and fast Fourier transformation 利用模拟和快速傅立叶变换进行代谢系统辨识
T. Daloze, G. Fink, H. Brunengraber, M.J. Corinthios
{"title":"Metabolic system identification using simulation and fast Fourier transformation","authors":"T. Daloze, G. Fink, H. Brunengraber, M.J. Corinthios","doi":"10.1109/IEMBS.1988.94630","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94630","url":null,"abstract":"A biological model of ketone body metabolism in the rat heart highlights pseudoketogenesis caused by reversible activation of acetoacetate. A mathematical system based on differential equations of isotopic fluxes is solved numerically. Different sets of unknown kinetic constants cannot be discriminated because of concentration patterns, but these patterns can be further analyzed. System poles are located by a fast Z-transform algorithm. The Z plane is scanned along constant damping contours, using an efficient fast Fourier transform algorithm. This simulation and Z-domain scanning approach reduce the need for subjective analysis of experimental data.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133651902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Improved reliability of impedance cardiography by new signal processing techniques 新的信号处理技术提高了阻抗心动图的可靠性
S. P. Reddy, L. Shyu, J. Nagel, N. Schneiderman
{"title":"Improved reliability of impedance cardiography by new signal processing techniques","authors":"S. P. Reddy, L. Shyu, J. Nagel, N. Schneiderman","doi":"10.1109/IEMBS.1988.94396","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94396","url":null,"abstract":"The authors used the impedance cardiogram (ICG), the phonocardiogram (PCG), and the electrocardiogram (ECG) to determine stroke volume and systolic time intervals. Comparisons between a fully automated PC/AT-based signal processing system and a computer-assisted visual detection processing system revealed comparable means, standard errors, correlations (Spearman r), and reliability (Chronbach's alpha ) coefficients on all relevant parameters. Other analyses confirmed the utility of using Q onset to mark the beginning of ventricular systole, the B point of the ICG to denote the aortic opening, and end diastole as the reference for determining the amplitude of dZ/dt/sub mzx/.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131966151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Blood gas analysis: a knowledge-based adviser for the interpretation of results 血气分析:以知识为基础的顾问解释结果
J. Chelsom, Tim Ellis, Ewart R. Carson, D. Cramp
{"title":"Blood gas analysis: a knowledge-based adviser for the interpretation of results","authors":"J. Chelsom, Tim Ellis, Ewart R. Carson, D. Cramp","doi":"10.1109/IEMBS.1988.95168","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.95168","url":null,"abstract":"An intelligent knowledge-based system is being developed to assist clinicians with the interpretation of the results of blood-gas analysis in an intensive care unit. The system links directly to an automated blood-gas analyzer for data transfer, thus reducing the time-consuming interaction between computer and clinician. Knowledge held in frames is manipulated by a blackboard system to produce rapid diagnosis of acid-base disorders and underlying diseases. Deeper knowledge of the domain, held in a semantic network, is used to provide detailed explanation of the system's conclusions and to answer general queries about acid-base physiology.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134015193","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
On-line spectral analysis of electrogastrographical signals 胃电信号的在线频谱分析
J. Chen, J. Vandewalle, W. Sansen, G. Vantrappen, J. Janssens
{"title":"On-line spectral analysis of electrogastrographical signals","authors":"J. Chen, J. Vandewalle, W. Sansen, G. Vantrappen, J. Janssens","doi":"10.1109/IEMBS.1988.94863","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94863","url":null,"abstract":"The recording of human gastric myoelectrical activity by means of cutaneous electrodes attached on the abdominal skin, called electrogastrography (EGG), provides a noninvasive method of studying the electrogastric behavior. The normal frequency of the gastric signal is about 0.05 Hz. However, sudden changes of its frequency have been observed and are generally considered to be related to the gastric motility disorder. This suggests that spectral analysis could serve as a valuable tool for practical purposes. An autoregressive moving-average spectral method is presented. It is based on the adaptive IIR filter and therefore provides both time and frequency information of the signal. The method has been applied to the running spectral analysis of the cutaneous EGG signals. The spectral analysis of the postprandial EGGs is presented.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115511426","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Silicon based microstructures suitable for intracortical electrical stimulation (visual prosthesis application) 适用于皮质内电刺激的硅基微结构(视觉假体应用)
R. Normann, P. K. Campbell, Wai Ping Li
{"title":"Silicon based microstructures suitable for intracortical electrical stimulation (visual prosthesis application)","authors":"R. Normann, P. K. Campbell, Wai Ping Li","doi":"10.1109/IEMBS.1988.94953","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94953","url":null,"abstract":"The authors have produced a 0.4-mm*0.4-mm*1.6-mm, three-dimensional, silicon-based microstructure which can be used for stimulation of cortical neurons. The structure consists of 100 pyramidal-shaped needles, each 1.5 mm long with a base about 0.06 mm on a side. The entire structure is passivated with silicon nitride except for the tips of the needles, which are coated with platinum. The mechanical properties of these structures and the tissue reaction to them were studied in cat cortex. Impact insertion of the arrays produces good implantation with minimal tissue insult. Preliminary histological studies suggest that cortical tissues are not adversely affected by these microstructures.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123349563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Analysis of locomotion in the horse using computer aided engineering software 用计算机辅助工程软件对马的运动进行分析
A. J. van den Bogert, A. Sauren, H. Schamhardt
{"title":"Analysis of locomotion in the horse using computer aided engineering software","authors":"A. J. van den Bogert, A. Sauren, H. Schamhardt","doi":"10.1109/IEMBS.1988.94853","DOIUrl":"https://doi.org/10.1109/IEMBS.1988.94853","url":null,"abstract":"An application of the DADS rigid-body package for analysis of locomotion in the horse is described. An important subject of study in equine locomotion research is the magnitude and distribution of forces inside the body, as it is generally assumed that overloading of joints, ligaments, and tendons is one of the main causes of acute and chronic injuries in equestrian sports. A biomechanical model of the horse has been developed to simulate the behavior of the musculoskeletal system under varying circumstances. The simulation software described was implemented on an Apollo DN4000 workstation using the DADS software package (version 5.0). Normal walking was simulated, using kinematic data for the proximal joints and tendon strain recordings from a normal walking pony as driving input for the model. Both movements and forces resemble observations in live animals. During the development of this model, much insight into the functioning of the locomotor system was gained. In particular, the role of polyarticular muscles and ligaments in the equine limbs was better understood.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128268792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信