Improved reliability of impedance cardiography by new signal processing techniques

S. P. Reddy, L. Shyu, J. Nagel, N. Schneiderman
{"title":"Improved reliability of impedance cardiography by new signal processing techniques","authors":"S. P. Reddy, L. Shyu, J. Nagel, N. Schneiderman","doi":"10.1109/IEMBS.1988.94396","DOIUrl":null,"url":null,"abstract":"The authors used the impedance cardiogram (ICG), the phonocardiogram (PCG), and the electrocardiogram (ECG) to determine stroke volume and systolic time intervals. Comparisons between a fully automated PC/AT-based signal processing system and a computer-assisted visual detection processing system revealed comparable means, standard errors, correlations (Spearman r), and reliability (Chronbach's alpha ) coefficients on all relevant parameters. Other analyses confirmed the utility of using Q onset to mark the beginning of ventricular systole, the B point of the ICG to denote the aortic opening, and end diastole as the reference for determining the amplitude of dZ/dt/sub mzx/.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The authors used the impedance cardiogram (ICG), the phonocardiogram (PCG), and the electrocardiogram (ECG) to determine stroke volume and systolic time intervals. Comparisons between a fully automated PC/AT-based signal processing system and a computer-assisted visual detection processing system revealed comparable means, standard errors, correlations (Spearman r), and reliability (Chronbach's alpha ) coefficients on all relevant parameters. Other analyses confirmed the utility of using Q onset to mark the beginning of ventricular systole, the B point of the ICG to denote the aortic opening, and end diastole as the reference for determining the amplitude of dZ/dt/sub mzx/.<>
新的信号处理技术提高了阻抗心动图的可靠性
作者使用阻抗心电图(ICG)、心音图(PCG)和心电图(ECG)来确定搏量和收缩时间间隔。将全自动PC/ at信号处理系统与计算机辅助视觉检测处理系统进行比较,发现所有相关参数的均值、标准误差、相关性(Spearman r)和可靠性(Chronbach’s alpha)系数具有可比性。其他分析证实了用Q起点标记心室收缩开始,ICG B点表示主动脉开口,舒张结束作为确定dZ/dt/sub mzx/.>振幅的参考的效用
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信