A body surface mapping unit for recording during coronary angioplasty

R. Macleod, B. Hoyt, J. Sherwood, P. MacInnis, R. Potter, B. Horáček
{"title":"A body surface mapping unit for recording during coronary angioplasty","authors":"R. Macleod, B. Hoyt, J. Sherwood, P. MacInnis, R. Potter, B. Horáček","doi":"10.1109/IEMBS.1988.94424","DOIUrl":null,"url":null,"abstract":"A low-noise multichannel recording system for simultaneously registering up to 256 ECG (electrocardiogram) signals in digital form is described. The unit's features include: patient isolation and radiolucent electrodes required for use during cardiac catherization and angioplasty procedures; continuous data collection over several minutes; gain and sampling frequency under software control; and flexible, modular design. The mapping system consists of three physically separate units: the bedside unit, the controller and communications interface, and the computer. The method chosen to ensure adequate patient isolation and still maintain sufficient sensitivity and signal/noise characteristics is to isolate the entire input stage of the recording system and power it with rechargeable batteries.<<ETX>>","PeriodicalId":227170,"journal":{"name":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1988.94424","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A low-noise multichannel recording system for simultaneously registering up to 256 ECG (electrocardiogram) signals in digital form is described. The unit's features include: patient isolation and radiolucent electrodes required for use during cardiac catherization and angioplasty procedures; continuous data collection over several minutes; gain and sampling frequency under software control; and flexible, modular design. The mapping system consists of three physically separate units: the bedside unit, the controller and communications interface, and the computer. The method chosen to ensure adequate patient isolation and still maintain sufficient sensitivity and signal/noise characteristics is to isolate the entire input stage of the recording system and power it with rechargeable batteries.<>
冠状动脉成形术中记录的体表测绘装置
描述了一种可同时记录多达256个数字心电图信号的低噪声多通道记录系统。该单元的特点包括:患者隔离和在心导管和血管成形术过程中需要使用的放射电极;在几分钟内连续收集数据;软件控制增益和采样频率;并且灵活、模块化设计。绘图系统由三个物理上独立的单元组成:床边单元、控制器和通信接口以及计算机。为确保足够的患者隔离并保持足够的灵敏度和信号/噪声特性,选择的方法是隔离记录系统的整个输入级,并使用可充电电池为其供电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信