2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)最新文献

筛选
英文 中文
Improvement of the Vehicle's Onboard Diagnostic System by Using the Vibro-Diagnostics Method 用振动诊断方法改进车载诊断系统
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526093
I. Makarova, E. Mukhametdinov, V. Mavrin, K. Shubenkova, R. Garipov
{"title":"Improvement of the Vehicle's Onboard Diagnostic System by Using the Vibro-Diagnostics Method","authors":"I. Makarova, E. Mukhametdinov, V. Mavrin, K. Shubenkova, R. Garipov","doi":"10.1109/DIAGNOSTIKA.2018.8526093","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526093","url":null,"abstract":"The article analyzes ways to increase the operational reliability of trucks by monitoring and diagnosing their technical condition. Preventing sudden vehicles failures is possible with the help of built-in diagnostic systems. The article analyzes existing on-board and stationary diagnostic systems. The types of sensors and their signals used to diagnose the condition of vehicles systems are given. Methods of transformation and processing of signals are determined. The connections of structural and diagnostic parameters of the vehicles are established. The possibility of application of vibration diagnostics methods for assessing the technical condition and predicting the remaining life of the vehicle's clutch under operating conditions is explored. The authors proposed a way to improve the on-board diagnostics system with the help of a set of methods, rules and means necessary for measuring the parameters of the system's operation, converting them into diagnostic parameters to assess the technical state of the system under study. The article gives an example of an integrated system for diagnosing vehicle's clutch with vibration sensors.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"312 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131804553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Spatially-resolved diagnosis of power cables in field environment: challenges and opportunities 野外环境下电力电缆的空间分辨诊断:挑战与机遇
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526087
E. Fischer, C. Weindl
{"title":"Spatially-resolved diagnosis of power cables in field environment: challenges and opportunities","authors":"E. Fischer, C. Weindl","doi":"10.1109/DIAGNOSTIKA.2018.8526087","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526087","url":null,"abstract":"- In this paper, the challenges for building up a prototype system for spatially-resolved diagnosis of power cables will be presented and the measurement method itself will be briefly described. In the case of application in field environment, several optimizations and first field measurements had to be performed with the goal of receiving boundary conditions for the field application, which will be specified in this article. The main part of the paper will be focused on a presentation of field measurement results of medium voltage power cables within challenges of multiple reflections and impedance matching. Furthermore, opportunities and solution approaches for reference simulation and measurements in field environment will be discussed.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"279 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131921451","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Equivalent circuit model for the error analysis of field dielectric loss angle measurement 场介质损耗角测量误差分析的等效电路模型
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526037
Z. Dan, Yang Xian, S. Wenxing, Cai Linglong, Tian Xiaofei, Yu Huizong, Du Lin
{"title":"Equivalent circuit model for the error analysis of field dielectric loss angle measurement","authors":"Z. Dan, Yang Xian, S. Wenxing, Cai Linglong, Tian Xiaofei, Yu Huizong, Du Lin","doi":"10.1109/DIAGNOSTIKA.2018.8526037","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526037","url":null,"abstract":"Dielectric loss angle is a very important parameter to evaluate the insulation condition of capacitive devices, which is the complement angle of voltage and leakage current. The angle value is hard to accurately obtained because of field interferences and other causes. The leakage current is so small which the signal path parameters and other interference contribute a fairly large error. In this paper, an equivalent circuit model of capacitive equipment considering multicomponent parameters is established. By analyzing the influence of electromagnetic field distribution and wiring modes on the leakage current path, an equivalent circuit model considering many influencing factors is proposed. This paper also analyzes the influence of aging, temperature and humidity on the equivalent circuit parameters, explores the causes of the current measurement error, and finally obtains the transfer function of the leakage current and the path component parameters.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130935641","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Experience in using different diagnostics methods for field testing of medium-voltage cables with extruded insulation in Nuclear Power Plants 在核电站挤压绝缘中压电缆现场测试中使用不同诊断方法的经验
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526119
Simon Podkoritnik, Marko Pirc
{"title":"Experience in using different diagnostics methods for field testing of medium-voltage cables with extruded insulation in Nuclear Power Plants","authors":"Simon Podkoritnik, Marko Pirc","doi":"10.1109/DIAGNOSTIKA.2018.8526119","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526119","url":null,"abstract":"Medium-voltage cables represent an important component of the Nuclear Power Plant (NPP) nuclear island as well as of its balance of plant. Therefore, it is reasonable to monitor their aging process and expected reliability. There are, however, many electrical, thermal, mechanical and radiation stresses, which, through time, can influence the occurrence of insulation degradation. Assessment and evaluation of the condition of cable insulation is supposed to be carried out periodically, during the scheduled outages and maintenance activities. Accordingly, it is necessary to carefully select the proper efficient diagnostic methods and different scrutinises, particularly studied and purposeful for determining the aging grade and overall adequacy of the cable insulation. To avoid unplanned failures with loss of critical equipment, the insulation must be properly tested. Therefore electrical and non-electrical diagnostic methods are used to ensure proper assessment of cable insulation deterioration. This paper reports on experience with application of different diagnostic methods boosting tendency to improve monitoring of the condition of the cable insulation in the NPP Krško, The diagnostic testing and measurements on cables recommended to be done in nuclear power plant respecting a good practice of asset maintenance management is discussed.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132892341","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Wide-band Voltage Measement System based on Multi-capacitive Current Sensors 基于多电容电流传感器的宽带电压测量系统
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526125
Lin Du, Disheng Wang, Jiayu Tan, Youyuan Wang
{"title":"Wide-band Voltage Measement System based on Multi-capacitive Current Sensors","authors":"Lin Du, Disheng Wang, Jiayu Tan, Youyuan Wang","doi":"10.1109/DIAGNOSTIKA.2018.8526125","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526125","url":null,"abstract":"A wide-band voltage measurement system is proposed to optimize voltage monitoring on power grid based on capacitive current. Capacitive device leakage current components in frequency bands of 30Hz~3kHz and 3kHz~1MHz are acquired respectively by two inductance coils, whose magnetic permeability are different. Then wide-band voltage of 30Hz $sim$ 1MHz is rebuilt based on two paths of signals. This paper introduces the components of the measurement system, and optimizes component parameters to ensure sensors' amplitude and frequency characteristics. Experiment results verified that the measurement system has good accuracy and linearity in the measurement of power frequency voltage, the switching overvoltage and the lightning overvoltage.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125207569","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Modified Method for Evaluation of Stress in Drawn Wires from Magnetic Measurements in the Rayleigh Region 瑞利地区磁测拉丝应力评定的改进方法
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526030
Artur Wodzynski, M. Suliga, K. Chwastek
{"title":"A Modified Method for Evaluation of Stress in Drawn Wires from Magnetic Measurements in the Rayleigh Region","authors":"Artur Wodzynski, M. Suliga, K. Chwastek","doi":"10.1109/DIAGNOSTIKA.2018.8526030","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526030","url":null,"abstract":"The paper focuses on the estimation of residual stress level present in drawn wires after the production process. The presented method relies on the measurements of magnetic properties of drawn wires. Stress is calculated from a relationship derived from Sablik's theory. The Sablik's extension of the effective field is applied to a description of magnetization curve different from the originally considered.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127906922","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Void and surface partial discharge pattern properties 空穴和表面局部放电模式特性
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526142
D. Gross
{"title":"Void and surface partial discharge pattern properties","authors":"D. Gross","doi":"10.1109/DIAGNOSTIKA.2018.8526142","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526142","url":null,"abstract":"Phase-resolved partial discharge pattern are being used as a diagnostic tool since about 25 years. However, still up to now, often partial discharge pattern interpretation is considered as “black magic”. Many of the properties of such $varphi-q-n$ pattern can be explained when understanding the underlying gas-discharge principles, the charge carrier generation (as well as their decay), the effects of the discharge site geometry, and the shape of the high voltage applied.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116423955","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Market-driven flexibility of grid usage and network-oriented load balancing 市场驱动的网格使用灵活性和面向网络的负载平衡
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526105
T. Blenk, C. Weindl, A. Bauer, I. Mladenovic
{"title":"Market-driven flexibility of grid usage and network-oriented load balancing","authors":"T. Blenk, C. Weindl, A. Bauer, I. Mladenovic","doi":"10.1109/DIAGNOSTIKA.2018.8526105","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526105","url":null,"abstract":"In particular, the integration of renewable energies brings out new challenges for the operation and the design of power networks. Up to the year 2000 a clear vertical distribution structure and the corresponding load-flow was visible. Since that time, due to the increasing number of regenerative production plants in the lower distribution network levels, an additional horizontal utilization takes place at an increasing number of time intervals. As a result, the weaker, lower distribution structures, in which more than 75% of renewable energy systems feed in, are increasingly burdened. In combination with the lack of opportunities, e.g. the willingness of the population to demand side management and the still limited storage possibilities this means, that the network resources in these areas are partially heavily loaded. In the following paper, models and methods will be presented, which will open up opportunities to limit the load flow to the physically required by an intermittent localization of the energy usage.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114953780","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Current trends in the management of diagnostic processes in testing laboratories 测试实验室诊断过程管理的当前趋势
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526136
A. Benešová, M. Hirman, F. Steiner, J. Tupa
{"title":"Current trends in the management of diagnostic processes in testing laboratories","authors":"A. Benešová, M. Hirman, F. Steiner, J. Tupa","doi":"10.1109/DIAGNOSTIKA.2018.8526136","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526136","url":null,"abstract":"This article is focused on management system of diagnostic processes in testing laboratories. Diagnostics is a field of science whose main task is to obtain information about device and its condition. The diagnostic processes are important not only to ensure customer safety, but also as a feedback to improve a product. The main aim was application of the management system requirements to the selected diagnostic process according to ISO 17025:2017. In the first part of this article is the introduction about product life cycle and current trends in the management system of the testing laboratories. In the next part, the selected diagnostic process was described and the risks of this process are analyzed and evaluated by the Semi-quantitative risk assessment matrix.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122829722","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Quantification of Corona Discharges on High Voltage Electrical Equipment in the UV Spectrum using a Corona Camera 用电晕照相机在紫外光谱中定量测定高压电气设备的电晕放电
2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika) Pub Date : 2018-09-01 DOI: 10.1109/DIAGNOSTIKA.2018.8526024
N. Maistry, R. Schutz, E. Cox
{"title":"The Quantification of Corona Discharges on High Voltage Electrical Equipment in the UV Spectrum using a Corona Camera","authors":"N. Maistry, R. Schutz, E. Cox","doi":"10.1109/DIAGNOSTIKA.2018.8526024","DOIUrl":"https://doi.org/10.1109/DIAGNOSTIKA.2018.8526024","url":null,"abstract":"The current power line fault detection equipment can only locate a fault by detecting corona and heat radiated by the faults. This equipment cannot quantify the ultraviolet (UV) radiation of the fault in radiometric dimensions (W/cm2). The CSIR has developed the first radiometric technology camera platform in both the UV and IR spectrums (“QUVIR‘,) in order to quantify power line faults. This paper will provide a brief description on the new UV quantification algorithm.","PeriodicalId":211666,"journal":{"name":"2018 International Conference on Diagnostics in Electrical Engineering (Diagnostika)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116839422","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信