{"title":"The Effect of Water Coolant and Bur Type on Pulp Temperature When Removing Tooth Structure and Restorative Dental Materials.","authors":"C Mafrici, M Kingston, R Grice, P V Abbott","doi":"10.2341/23-033-L","DOIUrl":"10.2341/23-033-L","url":null,"abstract":"<p><strong>Objective: </strong>The aim was to compare intrapulp temperature (IPT) changes when flat-fissure diamond burs and pear-shaped tungsten carbide burs were used to cut tooth structure, amalgam, and composite resin with and without water coolant.</p><p><strong>Methods: </strong>Thermocouples were inserted into the pulp chamber of extracted intact mandibular molars. The thermocouples were connected to an electronic thermometer that detects temperature every second to an accuracy of 0.1°C. IPT changes were recorded while using a high-speed handpiece during MOD cavity preparations (n=40), composite resin removal (n=40), and amalgam removal (n=40). A two-way ANOVA was used for each procedure to test for the effect of bur (pear-shaped tungsten carbide vs flat-fissured diamond) and water coolant (on vs off), with significant main effects (α=0.05) further analyzed using Tukey's multiple comparison test.</p><p><strong>Results: </strong>During MOD cavity preparation, water coolant reduced changes in IPT (0.03±0.27°C) compared to no water coolant (1.27±0.29°C) when tungsten carbide burs were used (p<0.05) but not when diamond burs were used. During composite resin removal, tungsten carbide burs had less changes in IPT (0.55±0.18°C) compared to diamond burs (1.66±0.50°C) with no water coolant (p<0.05). Water coolant also reduced changes in IPT (0.09±0.14°C) compared to no water coolant (1.66±0.50°C) when diamond burs were used (p<0.01). Water coolant did not significantly affect IPT when tungsten carbide burs were used. During amalgam removal, tungsten carbide burs had lower changes in IPT (0.56±0.15°C) compared to diamond burs (1.88±0.43°C) with no water coolant (p<0.05). Water coolant also significantly reduced changes in IPT (0.71±0.2°C) compared to no water coolant (1.88±0.43°C) when diamond burs were used (p<0.05) but not when tungsten carbide burs were used.</p><p><strong>Conclusions: </strong>Water coolant reduced IPT changes when drilling tooth structure with tungsten carbide burs, but not when removing amalgam or composite. Conversely, water coolant reduced IPT changes when drilling with flat fissure diamond burs to remove amalgam and composite, but not when removing tooth structure. When amalgam and composite were removed without water coolant, the tungsten carbide burs resulted in lower IPT changes than when flat fissure diamond burs were used in the same way.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"91-97"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P Ntovas, N Gogolas, G Gogolas, E Mougiou, E Papazoglou
{"title":"Tooth Splinting: Implementing a 3D-printed Guide with Pre-defined Composite Resin Reservoirs: A Digital Workflow.","authors":"P Ntovas, N Gogolas, G Gogolas, E Mougiou, E Papazoglou","doi":"10.2341/23-069-T","DOIUrl":"10.2341/23-069-T","url":null,"abstract":"<p><p>The integration of digital technologies in dentistry has led to the development of various techniques to facilitate tooth splinting. In the present digital workflow, the advantages of the virtual treatment plan were combined with the versatility of the commercially available tooth splinting materials. An intraoral scanner was utilized to digitize both arches along with the patient's occlusion, eliminating the need for models from physical impressions. A template based on the virtual design of the splint was 3D-printed and served as a guide to individualize a twisted wire. The bent wire was transferred and bonded, using a 3D-printed template with pre-defined reservoirs for the composite resin. Digital technology has been implemented for tooth splinting, by fabricating a splint after its virtual design. However, the digital fabrication of the metal splints is available for limited splinting materials and the service is only provided by specific centers around the world.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"5-10"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499084","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Post-cure Heat Treatments Influence the Mechanical and Optical Properties of Acrylic and Bis-acryl Composite Resins.","authors":"L B Morgado, M S Pedrosa, I S Medeiros","doi":"10.2341/23-011-L","DOIUrl":"10.2341/23-011-L","url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil).</p><p><strong>Methods and materials: </strong>Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05).</p><p><strong>Results: </strong>The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05).</p><p><strong>Conclusion: </strong>Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"76-83"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138451997","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C A Jurado, D Lee, P Ramirez, D A Cortes-Treviño, A Tsujimoto
{"title":"Fracture Resistance of Chairside CAD/CAM Lithium Disilicate-reinforced Ceramic Occlusal Veneers With and Without Margin and Full Coverage Crowns.","authors":"C A Jurado, D Lee, P Ramirez, D A Cortes-Treviño, A Tsujimoto","doi":"10.2341/23-043-L","DOIUrl":"10.2341/23-043-L","url":null,"abstract":"<p><strong>Objective: </strong>The aim of this investigation was to compare the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate-reinforced ceramic occlusal veneers with and without margin and traditional full coverage premolar crowns.</p><p><strong>Methods and materials: </strong>A total of 60 chairside CAD/CAM lithium disilicate-reinforced ceramic (Amber Mill, Hass Bio) restorations were designed and fabricated with a chairside CAD/CAM system (CEREC Dentsply Sirona). The restorations were divided into three groups (n=20): 1) occlusal veneer with 1.0-mm uniform occlusal thickness and with chamfer margin; 2) occlusal veneer with 1.0-mm uniform occlusal thickness and without margin; and 3) full coverage crown with uniform occlusal thickness and gingival margin. Occlusal veneers and crowns were cemented with dual cured resin luting cement (Multilink, Ivoclar Vivadent) to printed resin dies, load cycled (5 million load cycles at 1 Hz with 275 N force), and then loaded until fracture. Load at break (LB) and peak load (PL) until fracture were recorded. Scanning electron microscope images of the tested restorations on the abutments were obtained.</p><p><strong>Results: </strong>Fracture strengths were different depending on the design of the restoration. There was no significant difference in fracture strength between the two types of occlusal veneer (LB: 1132.45 N; PL: 1143.30 N for veneers with margin; LB: 1149.25 N; PL: 1219.05 N for veneers without margin). Full coverage crowns showed the lowest fracture resistance (LB: 936.26 N, PL: 976.42 N), which was significantly lower than both designs of occlusal veneer.</p><p><strong>Conclusions: </strong>The fracture resistance of the CAD/CAM lithium disilicate-reinforced ceramic restorations was influenced by the design. Occlusal veneers with and without margin displayed higher fracture resistance than traditional crowns.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"84-90"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
R K Nakagawa, H H Araújo de Oliveira, L G Abreu, de Castro Albuquerque R, Dos Santos Alves Morgan Lf, Nogueira Moreira A
{"title":"Pulpal Temperature Variances During Step-by-step Adhesive Restorative Procedure Using Three Different High-irradiance Light-curing Units.","authors":"R K Nakagawa, H H Araújo de Oliveira, L G Abreu, de Castro Albuquerque R, Dos Santos Alves Morgan Lf, Nogueira Moreira A","doi":"10.2341/22-045-L","DOIUrl":"10.2341/22-045-L","url":null,"abstract":"<p><p>The rise in temperature in pulp tissues is related not only to heat transfer by high-irradiance light-curing units (LCUs), but also to restorative procedures. This research aimed to compare the rise in pulp temperature (PT) induced by three LCUs at each restorative step while considering the influence of resin composite shade and thickness. To accomplish this, the investigators used a proposed experimental model replicating pulp fluid circulation with a controlled, simulated intraoral temperature in bovine incisors. The recorded external and internal PT ranged from 36.7°C to 37.1°C and 32.7°C to 33.0°C, respectively. A significant decrease of internal temperature was recorded during class V preparation, followed by a progressive and representative rise of temperature in the subsequent restorative steps. The temperature was significantly higher during light curing of the adhesive system using Valo compared to light curing using Elipar and Radii Cal. However, none of the analyzed devices produced a temperature that exceeded the pulp tolerance limit (a temperature increase over 5.5°C). The paired test showed no significant difference in pulp temperature associated with the thickness of the increment of resin composite. However, shade was found to have more influence on the amount of energy absorbed by pulp tissue-A1 samples showed significantly higher temperature variation compared to samples using the A4 shade of resin composite. To conclude, the microcirculation and the performance of procedures under constant air-water flux dissipate the heat absorbed by the pulp. Additionally, the data suggest that all three LCUs analyzed can be safely used in clinical procedures, and that the resin composite shade may influence the amount of irradiance delivered to the tooth surface and represents a significant factor in pulp temperature variance.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"43-51"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139098383","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E B Sanfelice, Ab da Silva Heck, H R Bittencourt, Jbb Weber, L H Burnett, A M Spohr
{"title":"Short-term Results of the Masking Effect of an Infiltrant Resin on Mild Molar Incisor Hypomineralization Lesions in Anterior Teeth.","authors":"E B Sanfelice, Ab da Silva Heck, H R Bittencourt, Jbb Weber, L H Burnett, A M Spohr","doi":"10.2341/23-029-C","DOIUrl":"10.2341/23-029-C","url":null,"abstract":"<p><p>This non-controlled clinical study evaluated the masking effect of an infiltrant resin on mild molar incisor hypomineralization (MIH) lesions. Thirty MIH-affected anterior teeth with creamy/ white opacities from 12 children aged 6-15 years received the application of an infiltrant resin (Icon- DMG). Standard photographs were taken before (T1), immediately after (T2), and 1 week after (T3) resin infiltration. Two calibrated examiners qualitatively analyzed the color match using the Fédération Dentaire Internationale (FDI) scale. The binomial distribution test analyzed the scores of the color match at T1 with T2 and T3, and McNemar's test analyzed the scores of the color match between T2 and T3 (α=0.05). There was a significant increase in color match between T1 and T2 (p=0.0005), between T1 and T3 (p=0.0005), and between T2 and T3 (p=0.0019). It was concluded that infiltrant resin was effective in improving the esthetic appearance of creamy/white opacities on MIH-affected anterior teeth.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"34-42"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139098384","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A O Miranda, M W Favoreto, T P Matos, A S Castro, Pvm Kunz, J L Souza, P Carvalho, A Reis, A D Loguercio
{"title":"Color Match of a Universal-shade Composite Resin for Restoration of Non-carious Cervical Lesions: An Equivalence Randomized Clinical Trial.","authors":"A O Miranda, M W Favoreto, T P Matos, A S Castro, Pvm Kunz, J L Souza, P Carvalho, A Reis, A D Loguercio","doi":"10.2341/23-021-C","DOIUrl":"10.2341/23-021-C","url":null,"abstract":"<p><strong>Purpose: </strong>The objective of this double-blind, split-mouth, randomized clinical trial was to evaluate the color match of a single-shade composite resin Admira Fusion X-tra in comparison with a multi-shade composite resin Admira Fusion in non-carious cervical lesion restorations (NCCLs).</p><p><strong>Methods and materials: </strong>One hundred and twenty restorations were performed on NCCLs with two restorative materials (n=60). After prophylaxis, the teeth were isolated with a rubber dam, and one universal adhesive was applied in the selective enamel etching strategy. For both groups, the restorations were inserted incrementally and light-cured. The values of the coordinates L*, a*, and b* in the cervical third before vs after the restorations and cervical vs middle third after the restorations were evaluated using a digital spectrophotometer after the coordinate values were used to calculate the CIEDE (ΔE00). The restorations were evaluated at baseline and after 7 days of clinical performance according to the FDI criteria. Statistical analysis was performed using the Chi-square test for all parameters. Color change was analyzed by Student t-test for paired samples (α=0.05).</p><p><strong>Results: </strong>All restorations were evaluated after 7 days. Regarding the color measurement, no significant difference was observed when Admira Fusion was compared to Admira Fusion X-tra for any of the comparisons performed (p>0.05). However, the values of ΔE00 in the cervical third before vs after the restorations were higher when compared with ΔE00 observed when the cervical vs middle third after restorations were compared. All restorations received the score \"clinically very good\" after 7 days for all outcomes, including the subjective color match, when evaluated for FDI criterion.</p><p><strong>Conclusions: </strong>The single-shade composite resin used achieves the same color match when compared to a multi-shade composite resin after 7 days in NCCLs.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"20-33"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499080","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}