Y Yang, G Inoue, K Hosaka, A Tichy, M Ikeda, J Tagami, Y Shimada
{"title":"The Effect of a Deproteinizing Pretreatment on the Bonding Performance and Acid Resistance of a Two-step Self-etch Adhesive on Eroded Dentin.","authors":"Y Yang, G Inoue, K Hosaka, A Tichy, M Ikeda, J Tagami, Y Shimada","doi":"10.2341/23-005-L","DOIUrl":"10.2341/23-005-L","url":null,"abstract":"<p><strong>Objectives: </strong>This study evaluated how deproteinization using sodium hypochlorite (6% NaOCl) or hypochlorous acid (50 ppm HOCl) with or without the subsequent use of an arylsulfinate salt-containing agent (Clearfil DC Activator; DCA; Kuraray Noritake Dental) affects the micro-tensile bond strength (μTBS) and formation of an acid-base resistant zone (ABRZ) of a two-step self-etch adhesive on eroded dentin.</p><p><strong>Methods: </strong>Coronal dentin surfaces of sound human molars were exposed to 48 cycles of demineralization (1% citric acid; 5 minutes) and remineralization (buffer solution with pH=6.4; 3.5 hours). They were then assigned to experimental groups according to the pretreatment used: none (negative control), NaOCl, NaOCl+DCA, HOCl, and HOCl+DCA. Sound dentin surfaces with no pretreatment were used as a positive control. The dentin surfaces were bonded with Clearfil SE Bond 2 (Kuraray Noritake Dental), and μTBS was measured either after 24 hours or 20,000 thermal cycles (TC). The μTBS data were statistically analyzed using a mixed-model analysis of variance (ANOVA) and t-tests with Bonferroni correction. Failure mode was determined with scanning electron microscopy (SEM), which was also used for the observation of ABRZ.</p><p><strong>Results: </strong>Among experimental groups, there was no significant difference between the negative control, HOCl, and HOCl+DCA after 24 hours, but the HOCl-pretreated groups exhibited significantly higher μTBS than the negative control after TC (p<0.01). Pretreatment with NaOCl and NaOCl+DCA resulted in significantly higher μTBS (p<0.001), but the highest μTBS was measured on sound dentin (p<0.001). TC decreased μTBS significantly in all groups (p<0.001) except for sound dentin and NaOCl+DCA (p>0.05). Adhesive failures prevailed in eroded groups, whereas cohesive failures were predominant on sound dentin. ABRZ was recognized in all groups but marked morphological differences were observed.</p><p><strong>Conclusions: </strong>The combined use of 6% NaOCl and the arylsulfinate salt-containing agent partially reversed the compromised bonding performance on eroded dentin, while the effect of 50 ppm HOCl was negligible.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"65-75"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138451998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Evaluation of Shade Reproducibility and Mechanical Properties of Preshaded and Manually Shaded Monolithic Zirconia.","authors":"I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari","doi":"10.2341/23-016-L","DOIUrl":"10.2341/23-016-L","url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.</p><p><strong>Methods and materials: </strong>Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).</p><p><strong>Results: </strong>Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).</p><p><strong>Conclusions: </strong>White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"110-116"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139098379","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A Semprum-Clavier, A Rodriguez, D Salazar, F Afshari, A Manzotti, L Saleh-Hassan, M Viana, A Bedran-Russo
{"title":"Clinical Comparison of Three Indirect Pulp Capping Restorative Protocols: A Randomized Controlled Prospective Study.","authors":"A Semprum-Clavier, A Rodriguez, D Salazar, F Afshari, A Manzotti, L Saleh-Hassan, M Viana, A Bedran-Russo","doi":"10.2341/22-094-C","DOIUrl":"10.2341/22-094-C","url":null,"abstract":"<p><strong>Objectives: </strong>The objective of this prospective double-blind clinical trial was to compare clinical outcomes of indirect pulp capping restorative protocols on permanent teeth over a 12-month period.</p><p><strong>Methods and materials: </strong>Deep carious lesions in permanent teeth (90) were randomly assigned to three indirect pulp capping protocols (n=30: TheraCal LC, Dycal, and no liner). All teeth were restored with resin composite. The outcome measures were pain (VAS scale) and success rate (pulp vitality based on percussion, palpation, cold test, and radiographic findings), collected at screening, intervention, and 24-hour, 7-day, 3-month, 6-month, and 12-month follow-up visits.</p><p><strong>Results: </strong>There was no statistically significant difference in tooth sensitivity among the three indirect pulp capping protocols nor in success rates among the restorative protocols after 1 year of follow-up (p>0.1).The respective success rates, as defined by the tooth remaining vital, after 1 year were: 96.2% for TheraCal LC, 100% for Dycal, and 100% for no liner.</p><p><strong>Conclusions: </strong>After 12-month evaluation, the success rate of indirect pulp capping therapy on permanent teeth was not affected by the pulp capping restorative protocol.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"11-19"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139098377","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Effect of Water Coolant and Bur Type on Pulp Temperature When Removing Tooth Structure and Restorative Dental Materials.","authors":"C Mafrici, M Kingston, R Grice, P V Abbott","doi":"10.2341/23-033-L","DOIUrl":"10.2341/23-033-L","url":null,"abstract":"<p><strong>Objective: </strong>The aim was to compare intrapulp temperature (IPT) changes when flat-fissure diamond burs and pear-shaped tungsten carbide burs were used to cut tooth structure, amalgam, and composite resin with and without water coolant.</p><p><strong>Methods: </strong>Thermocouples were inserted into the pulp chamber of extracted intact mandibular molars. The thermocouples were connected to an electronic thermometer that detects temperature every second to an accuracy of 0.1°C. IPT changes were recorded while using a high-speed handpiece during MOD cavity preparations (n=40), composite resin removal (n=40), and amalgam removal (n=40). A two-way ANOVA was used for each procedure to test for the effect of bur (pear-shaped tungsten carbide vs flat-fissured diamond) and water coolant (on vs off), with significant main effects (α=0.05) further analyzed using Tukey's multiple comparison test.</p><p><strong>Results: </strong>During MOD cavity preparation, water coolant reduced changes in IPT (0.03±0.27°C) compared to no water coolant (1.27±0.29°C) when tungsten carbide burs were used (p<0.05) but not when diamond burs were used. During composite resin removal, tungsten carbide burs had less changes in IPT (0.55±0.18°C) compared to diamond burs (1.66±0.50°C) with no water coolant (p<0.05). Water coolant also reduced changes in IPT (0.09±0.14°C) compared to no water coolant (1.66±0.50°C) when diamond burs were used (p<0.01). Water coolant did not significantly affect IPT when tungsten carbide burs were used. During amalgam removal, tungsten carbide burs had lower changes in IPT (0.56±0.15°C) compared to diamond burs (1.88±0.43°C) with no water coolant (p<0.05). Water coolant also significantly reduced changes in IPT (0.71±0.2°C) compared to no water coolant (1.88±0.43°C) when diamond burs were used (p<0.05) but not when tungsten carbide burs were used.</p><p><strong>Conclusions: </strong>Water coolant reduced IPT changes when drilling tooth structure with tungsten carbide burs, but not when removing amalgam or composite. Conversely, water coolant reduced IPT changes when drilling with flat fissure diamond burs to remove amalgam and composite, but not when removing tooth structure. When amalgam and composite were removed without water coolant, the tungsten carbide burs resulted in lower IPT changes than when flat fissure diamond burs were used in the same way.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"91-97"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499083","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P Ntovas, N Gogolas, G Gogolas, E Mougiou, E Papazoglou
{"title":"Tooth Splinting: Implementing a 3D-printed Guide with Pre-defined Composite Resin Reservoirs: A Digital Workflow.","authors":"P Ntovas, N Gogolas, G Gogolas, E Mougiou, E Papazoglou","doi":"10.2341/23-069-T","DOIUrl":"10.2341/23-069-T","url":null,"abstract":"<p><p>The integration of digital technologies in dentistry has led to the development of various techniques to facilitate tooth splinting. In the present digital workflow, the advantages of the virtual treatment plan were combined with the versatility of the commercially available tooth splinting materials. An intraoral scanner was utilized to digitize both arches along with the patient's occlusion, eliminating the need for models from physical impressions. A template based on the virtual design of the splint was 3D-printed and served as a guide to individualize a twisted wire. The bent wire was transferred and bonded, using a 3D-printed template with pre-defined reservoirs for the composite resin. Digital technology has been implemented for tooth splinting, by fabricating a splint after its virtual design. However, the digital fabrication of the metal splints is available for limited splinting materials and the service is only provided by specific centers around the world.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"5-10"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499084","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Post-cure Heat Treatments Influence the Mechanical and Optical Properties of Acrylic and Bis-acryl Composite Resins.","authors":"L B Morgado, M S Pedrosa, I S Medeiros","doi":"10.2341/23-011-L","DOIUrl":"10.2341/23-011-L","url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil).</p><p><strong>Methods and materials: </strong>Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05).</p><p><strong>Results: </strong>The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05).</p><p><strong>Conclusion: </strong>Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"76-83"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138451997","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C A Jurado, D Lee, P Ramirez, D A Cortes-Treviño, A Tsujimoto
{"title":"Fracture Resistance of Chairside CAD/CAM Lithium Disilicate-reinforced Ceramic Occlusal Veneers With and Without Margin and Full Coverage Crowns.","authors":"C A Jurado, D Lee, P Ramirez, D A Cortes-Treviño, A Tsujimoto","doi":"10.2341/23-043-L","DOIUrl":"10.2341/23-043-L","url":null,"abstract":"<p><strong>Objective: </strong>The aim of this investigation was to compare the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate-reinforced ceramic occlusal veneers with and without margin and traditional full coverage premolar crowns.</p><p><strong>Methods and materials: </strong>A total of 60 chairside CAD/CAM lithium disilicate-reinforced ceramic (Amber Mill, Hass Bio) restorations were designed and fabricated with a chairside CAD/CAM system (CEREC Dentsply Sirona). The restorations were divided into three groups (n=20): 1) occlusal veneer with 1.0-mm uniform occlusal thickness and with chamfer margin; 2) occlusal veneer with 1.0-mm uniform occlusal thickness and without margin; and 3) full coverage crown with uniform occlusal thickness and gingival margin. Occlusal veneers and crowns were cemented with dual cured resin luting cement (Multilink, Ivoclar Vivadent) to printed resin dies, load cycled (5 million load cycles at 1 Hz with 275 N force), and then loaded until fracture. Load at break (LB) and peak load (PL) until fracture were recorded. Scanning electron microscope images of the tested restorations on the abutments were obtained.</p><p><strong>Results: </strong>Fracture strengths were different depending on the design of the restoration. There was no significant difference in fracture strength between the two types of occlusal veneer (LB: 1132.45 N; PL: 1143.30 N for veneers with margin; LB: 1149.25 N; PL: 1219.05 N for veneers without margin). Full coverage crowns showed the lowest fracture resistance (LB: 936.26 N, PL: 976.42 N), which was significantly lower than both designs of occlusal veneer.</p><p><strong>Conclusions: </strong>The fracture resistance of the CAD/CAM lithium disilicate-reinforced ceramic restorations was influenced by the design. Occlusal veneers with and without margin displayed higher fracture resistance than traditional crowns.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"84-90"},"PeriodicalIF":2.2,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"138499081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}