2006 IEEE Power India Conference最新文献

筛选
英文 中文
Loadability margin estimation of power system using model trees 基于模型树的电力系统负荷裕度估计
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632534
N. P. Patidar, J. Sharma
{"title":"Loadability margin estimation of power system using model trees","authors":"N. P. Patidar, J. Sharma","doi":"10.1109/POWERI.2006.1632534","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632534","url":null,"abstract":"This paper presents a model tree (MT) method for estimation of loadability margins of power system under single line outage contingency and varying loading conditions. Maximum loadability margin is used as an index for voltage security assessment. In this paper model trees estimate the loadability margins in terms of continuous values. Learning states for MT are generated by computer simulation using continuation power flow and limits on reactive generation are considered while calculating loadability margins. Once the model tree is built it acquires the knowledge on the basis of which it estimates post-contingent maximum loadability margins efficiently and within the desired accuracy. The computation speed of this method is very high (ultra-fast), hence it can be more useful for real time applications. The effectiveness of this approach is tested on IEEE 30-bus test system, using unknown test patterns","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"61 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124949614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
A new filtering technique to eliminate decaying DC and harmonics for power system phasor estimation 一种新的滤波技术来消除电力系统相量估计中的衰减直流和谐波
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632494
V. Balamourougan, T. Sidhu
{"title":"A new filtering technique to eliminate decaying DC and harmonics for power system phasor estimation","authors":"V. Balamourougan, T. Sidhu","doi":"10.1109/POWERI.2006.1632494","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632494","url":null,"abstract":"During faults, the voltage and current signals available to the relay are affected by the decaying DC component and harmonics. To make proper decisions, most of the relaying algorithms require the fundamental frequency phasor information immune to decaying DC effect and harmonics. Conventional Fourier and LES phasor estimation algorithms are affected by the presence of decaying-exponential transient in the fault signal. This paper presents modified Fourier algorithm, which effectively eliminates the decaying DC component and the harmonics present in the fault signal. The decaying DC parameters are estimated by means of an out-of-band filtering technique. The decaying DC offset and harmonics are removed by means of a simple computational procedure which involves designing of two sets of orthogonal digital DFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying DC component. The proposed technique is compared with the conventional mimic plus full cycle DFT algorithm. The results show that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus DFT algorithms over a wide range of decay rates. In all the cases the convergence to the desired value is achieved within one cycle of the power system frequency","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"129 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123318478","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
Analysis, simulation and control of DSTATCOM in three-phase, four-wire isolated distribution systems 三相四线隔离配电系统DSTATCOM的分析、仿真与控制
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632556
B. Singh, A. Adya, A. Mittal, J. Gupta
{"title":"Analysis, simulation and control of DSTATCOM in three-phase, four-wire isolated distribution systems","authors":"B. Singh, A. Adya, A. Mittal, J. Gupta","doi":"10.1109/POWERI.2006.1632556","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632556","url":null,"abstract":"This paper deals with the performance of distribution static synchronous compensator (DSTATCOM) connected to an alternator of 42.5 kVA rating feeding four-wire linear loads. Simulation of DSTATCOM connected such weak system is carried out using standard MATLAB environment and power system toolbox. Results are simulated for linear resistive-inductive lagging power-factor loads for power factor correction, voltage regulation and load balancing for improving the power quality of the system isolated from the power grid","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125439556","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
A linearised small signal model of an HVDC link 高压直流输电线路的线性化小信号模型
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632523
S. Seifossadat, A. Shoulaie
{"title":"A linearised small signal model of an HVDC link","authors":"S. Seifossadat, A. Shoulaie","doi":"10.1109/POWERI.2006.1632523","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632523","url":null,"abstract":"In this paper a new method is presented for calculating the harmonic components of DC voltage and positive and negative sequence AC currents of both rectifier and inverter sides of AC HVDC link. The HVDC converters are represented by linearised small signal model and the calculations are based on the Fourier series calculations presented in our last work. To validate the method, a comparison is made with the PSCAD/EMTDC time domain simulation program","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124663068","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A novel approach for maintenance scheduling of generating units in a competitive environment 竞争环境下发电机组维修调度的一种新方法
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632614
R. Eshraghnia, M. Shanechi, H. R. Mashhadi, A. Karsaz
{"title":"A novel approach for maintenance scheduling of generating units in a competitive environment","authors":"R. Eshraghnia, M. Shanechi, H. R. Mashhadi, A. Karsaz","doi":"10.1109/POWERI.2006.1632614","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632614","url":null,"abstract":"In this paper, a new approach for maintenance scheduling of generating units of GENCOs in competitive environment is presented. In this environment, management of GENCOs and grid is separated, each maximizing its own benefit. The objective function for the GENCO is to sell electricity as much as possible, at proper time according to the market clearing price forecast. Various technical constraints such as generation capacity, duration of maintenances and maintenance continuity are being taken into account. The objective function of ISO is to maximize the reliability throughout the year; provided the energy purchase cost should be smaller than a predetermined amount when the units of GENCOs are out for maintenance. Therefore there are two objective functions for finding an optimum maintenance schedule in restructured power systems. In this paper we apply genetic algorithm methodology for finding the optimum preventive maintenance schedule of generating units","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124877524","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
A novel instantaneous power factor measurement method based on wavelet transform 一种基于小波变换的功率因数瞬时测量方法
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632635
A. Sarkar, S. Sengupta
{"title":"A novel instantaneous power factor measurement method based on wavelet transform","authors":"A. Sarkar, S. Sengupta","doi":"10.1109/POWERI.2006.1632635","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632635","url":null,"abstract":"Power factor monitoring is an important challenge in deregulated environment to maintain quality in delivered power as well as tariff assessment. In this paper, a unique power factor measurement method has been proposed that can measure the instantaneous power factor of a non-sinusoidal single-phase system accurately at every sample instant. The wavelet transform (WT) has been utilized for multiresolution analysis (MRA) of current waveform. The scheme has been implemented in real time with a Texas Instruments (TI) TMS320VC5416 digital signal processor (DSP) along with data acquisition system card PCI-02. The result has been found to be satisfactory","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122602447","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
The development of artificial neural network space vector PWM and diagnostic controller for voltage source inverter 电压源逆变器人工神经网络空间矢量PWM及诊断控制器的研制
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632564
P. Q. Dzung, L. M. Phương, P. Q. Vinh, N. Nhờ, Dao Minh Hien
{"title":"The development of artificial neural network space vector PWM and diagnostic controller for voltage source inverter","authors":"P. Q. Dzung, L. M. Phương, P. Q. Vinh, N. Nhờ, Dao Minh Hien","doi":"10.1109/POWERI.2006.1632564","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632564","url":null,"abstract":"This paper presents the development of neural-network-based controller of space vector modulation (ANN-SVPWM) for voltage-source inverters (VSI). This ANN-SVPWM controller completely covers the undermodulation and overmodulation modes with operation extended linearly and smoothly up to square wave (six-step) by using theory of modulation between the limit trajectories. The ANN controller has the advantage of the very fast implementation of an SVM algorithm that can increase the switching frequency of power switches of the static converter. Furthermore, a ANN diagnosis method for real-time fault detection of power switches is proposed in this paper. The ANN controller uses the individual training strategy with the fixed weight and supervised models. The complete ANN-SVPWM and diagnostic controller can be used in power applications such as APF, STATCOM, UPFC and motor drives. A computer simulation program is developed using Matlab/Simulink together with the neural network toolbox for training the ANN-controller","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"106 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128087973","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Effect of optimally located FACTS devices on active and reactive power price in deregulated electricity markets 放松管制的电力市场中FACTS设备优化配置对有功和无功电价的影响
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632530
S. Chanana, A. Kumar
{"title":"Effect of optimally located FACTS devices on active and reactive power price in deregulated electricity markets","authors":"S. Chanana, A. Kumar","doi":"10.1109/POWERI.2006.1632530","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632530","url":null,"abstract":"Effect of optimally located FACTS devices on active and reactive power price in deregulated electricity markets. In a deregulated power industry, the real time pricing of real and reactive power has emerged as an important issue to create fair open access in the electricity markets. These prices have a great impact on efficient and economic operation of electricity markets. Their accurate determination can send the signal for secure operation of the system. In this paper, the effect of optimally located FACTS devices: static VAr compensator (SVC), thyristor controlled series capacitor (TCSC) and thyristor controlled phase angle regulator (TCPAR) on real time prices has been studied. A mixed integer nonlinear programming (MINLP) based model is proposed for optimal placement of FACTS devices along with calculating active and reactive power marginal prices for an IEEE 14 bus system. The impact of placing FACTS devices on marginal prices and social welfare is observed. The cost of FACTS devices has also been considered for the study","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128494170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 27
Transient security assessment of the China Southern Power Grid considering induction motor loads 考虑感应电机负荷的南方电网暂态安全评估
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632610
J.S. Zhang, Y. Zhang, X. Zong, Z. Wu
{"title":"Transient security assessment of the China Southern Power Grid considering induction motor loads","authors":"J.S. Zhang, Y. Zhang, X. Zong, Z. Wu","doi":"10.1109/POWERI.2006.1632610","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632610","url":null,"abstract":"The impacts of induction motor load models, mechanical load characteristics, motor load percentages and motor undervoltage tripping and reconnection relay on the transient security assessment (TSA) of the China Southern Power Grid after large disturbances are examined using a transient security assessment tool in this paper. The results show that the first order mechanical model gives more optimistic TSA than the third order electro-mechanical model under the specified simulation conditions. Motor mechanical load characteristics have different impacts on the TSA, which depends on network and disturbance characteristics. Transient voltage instability occurs firstly and then generator angle instability occurs after a critical motor load percentage under specified simulation conditions. The motor undervoltage tripping and reconnection relay may be propitious to transient voltage stability but not to transient angle stability after a large disturbance. Induction motor loads should be included in the composite load models if reliable results are obtained","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130456171","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Design and simulation of an adaptive load shedding algorithm using a real network 基于实际网络的自适应减载算法设计与仿真
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632550
H. Seyedi, M. Sanaye-Pasand, M. Dadashzadeh
{"title":"Design and simulation of an adaptive load shedding algorithm using a real network","authors":"H. Seyedi, M. Sanaye-Pasand, M. Dadashzadeh","doi":"10.1109/POWERI.2006.1632550","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632550","url":null,"abstract":"In this paper a new adaptive under frequency load shedding algorithm is designed. The purpose of this method is to enhance the adaptability of under frequency relays and increase the security of power system during large disturbances. A suitable method to design the proposed adaptive under frequency load shedding scheme is described in detail. After completing the design, it is tested on a real power system by modeling the network in a power system studies software. Simulation results indicate that the proposed method has an improved performance for large disturbances while its response is similar to the conventional scheme for small disturbances","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"93 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124433655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 26
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×