{"title":"三相四线隔离配电系统DSTATCOM的分析、仿真与控制","authors":"B. Singh, A. Adya, A. Mittal, J. Gupta","doi":"10.1109/POWERI.2006.1632556","DOIUrl":null,"url":null,"abstract":"This paper deals with the performance of distribution static synchronous compensator (DSTATCOM) connected to an alternator of 42.5 kVA rating feeding four-wire linear loads. Simulation of DSTATCOM connected such weak system is carried out using standard MATLAB environment and power system toolbox. Results are simulated for linear resistive-inductive lagging power-factor loads for power factor correction, voltage regulation and load balancing for improving the power quality of the system isolated from the power grid","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Analysis, simulation and control of DSTATCOM in three-phase, four-wire isolated distribution systems\",\"authors\":\"B. Singh, A. Adya, A. Mittal, J. Gupta\",\"doi\":\"10.1109/POWERI.2006.1632556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the performance of distribution static synchronous compensator (DSTATCOM) connected to an alternator of 42.5 kVA rating feeding four-wire linear loads. Simulation of DSTATCOM connected such weak system is carried out using standard MATLAB environment and power system toolbox. Results are simulated for linear resistive-inductive lagging power-factor loads for power factor correction, voltage regulation and load balancing for improving the power quality of the system isolated from the power grid\",\"PeriodicalId\":191301,\"journal\":{\"name\":\"2006 IEEE Power India Conference\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power India Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERI.2006.1632556\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2006.1632556","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis, simulation and control of DSTATCOM in three-phase, four-wire isolated distribution systems
This paper deals with the performance of distribution static synchronous compensator (DSTATCOM) connected to an alternator of 42.5 kVA rating feeding four-wire linear loads. Simulation of DSTATCOM connected such weak system is carried out using standard MATLAB environment and power system toolbox. Results are simulated for linear resistive-inductive lagging power-factor loads for power factor correction, voltage regulation and load balancing for improving the power quality of the system isolated from the power grid