2006 IEEE Power India Conference最新文献

筛选
英文 中文
Experimental investigation of DVR with sliding mode control DVR滑模控制实验研究
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632533
R. R. Errabelli, Y. Kolhatkar, S.P. Das
{"title":"Experimental investigation of DVR with sliding mode control","authors":"R. R. Errabelli, Y. Kolhatkar, S.P. Das","doi":"10.1109/POWERI.2006.1632533","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632533","url":null,"abstract":"Voltage sags and swells are vital power quality problems and the dynamic voltage restorer (DVR) is known as an effective device to mitigate voltage sags and swells. The paper deals with the sliding mode control of single phase DVR for voltage sag/swell correction. A sliding mode controller is designed and developed for a single phase DVR. Using sliding mode control to the DVR, additional sag/swell detection method is eliminated. This improves the dynamic response of the DVR and also DVR is able to compensate for any variation in source voltage. Usage of sliding mode control to DVR, makes it multifunctional, such as compensation for voltage sag, swell, voltage flicker and voltage harmonics as well. Validity of the proposed control is verified through extensive simulation and experimental results","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127968190","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 29
EMTP RV-based study of solid-state fault current limiter for distribution systems 基于EMTP rv的配电系统固态故障限流器研究
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632505
V. Sood, R. Amin
{"title":"EMTP RV-based study of solid-state fault current limiter for distribution systems","authors":"V. Sood, R. Amin","doi":"10.1109/POWERI.2006.1632505","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632505","url":null,"abstract":"A fault current limiter (FCL) can reduce the fault current in a feeder system to a desired level and permit continuous power to be fed to loads. An EMTP RV based study to limit fault currents in a distribution system using a solid-state fault current limiter (SSFCL) is presented in this paper. For demonstration purposes, two types of distribution systems have been considered: a single-source radial system and a multiple source distribution system with a bus-tie. Simulations have been done for different types of faults to show that the SSFCL is effective for limiting fault currents","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132332890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Ergonomics in control centre design for power system 电力系统控制中心设计中的人机工程学
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632584
Parmod Kumar, V. Chandna, M.S. Thomas
{"title":"Ergonomics in control centre design for power system","authors":"Parmod Kumar, V. Chandna, M.S. Thomas","doi":"10.1109/POWERI.2006.1632584","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632584","url":null,"abstract":"The control centre in a SCADA set up is the place from where the operator/system engineer monitors the health of the power system and issues necessary control instructions. The operator/system engineer at the control centre undergoes a variety of muscular stresses while working for long durations, which degrades the quality of work. The proper design of the control center will ensure ease of functioning for the operator without experiencing stress in vital body parts. Care should be taken to install the different equipment for monitoring and controlling the power system in suitable atmosphere and housing. Hence, the authors in this paper have given emphasis on the various aspects of the ergonomics in designing the control room and housing rooms in the control centre for the power system","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"81 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132722296","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Coordinated maintenance scheduling of Gencos and Transcos in restructured power systems 重组电力系统中发电和输电系统的协调维护计划
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632515
T. Geetha, K. Shanti Swarup
{"title":"Coordinated maintenance scheduling of Gencos and Transcos in restructured power systems","authors":"T. Geetha, K. Shanti Swarup","doi":"10.1109/POWERI.2006.1632515","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632515","url":null,"abstract":"This paper proposes a methodology for the development of automatic scheduling techniques, for preventive maintenance of generating units and lines, in a competitive electric energy environment, with the inclusion of transmission constraints and forced outage rates, over a specified operational period. For generator maintenance the objective of the ISO is to maintain adequate level of reliability throughout the operational period (for which Bender's decomposition technique is used) and the objective of the GENCO is to maximize profit or to minimize loss in profit (for which transmission constrained price based unit commitment, TCPBUC, based on Lagrangian relaxation method is used). For line maintenance minimum cost model bender's technique with adequate level of reliability is used. A coordinating technique using penalty factors is incorporated to converge the conflicting objectives. The transmission constraints are modeled using DC sensitivity factors. Case study with a 6 bus, 3 generator, 11 line system is presented and discussed","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132826208","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Improved power quality AC-DC converter for electric multiple units in electric traction 改进的电力牵引中多电机组交直流变换器的电能质量
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632486
Bhim Singh, G. Bhuvaneswari, V. Garg
{"title":"Improved power quality AC-DC converter for electric multiple units in electric traction","authors":"Bhim Singh, G. Bhuvaneswari, V. Garg","doi":"10.1109/POWERI.2006.1632486","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632486","url":null,"abstract":"This paper presents the performance analysis of an improved power quality AC-DC converter (IPQC) fed vector controlled induction motor drive (VCIMD) for electric multiple units (EMU) application in electric traction of Indian railways. The IPQC enhances the input power factor close to unity and also reduces the total harmonic distortion (THD) of AC mains current. The converter provides bi-directional power flow capability during regenerative braking resulting in energy efficient operation of the drive. It also provides constant DC-link voltage during transient and steady state conditions. Detailed modeling and simulated results of the proposed converter fed induction motor drive are presented to demonstrate the features of improved power quality and energy conservation","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130418646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 35
Direct torque control of induction motor based on state feedback and variable structure fuzzy controllers 基于状态反馈和变结构模糊控制器的异步电动机直接转矩控制
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632576
Y. V. Siva Reddy, M. Vijaya Kumar, T. Brahmananda Reddy, J. Amarnath
{"title":"Direct torque control of induction motor based on state feedback and variable structure fuzzy controllers","authors":"Y. V. Siva Reddy, M. Vijaya Kumar, T. Brahmananda Reddy, J. Amarnath","doi":"10.1109/POWERI.2006.1632576","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632576","url":null,"abstract":"Direct torque control (DTC) is quite different from vector control and has several advantages over vector control. This paper presents intelligent control scheme together with conventional control scheme by fuzzy logic approach, to overcome the problems with uncertainties in the structure encountered with classical model based design. To adjust the speed of the direct torque control of induction motor drive, two control approaches are developed and applied. The first control approach combines the variable structure theory with fuzzy logic concept and in the second approach; a fuzzy state feedback controller is developed based on pole placement technique. Simulation studies have been carried out for different operating conditions of the drive system, the results have been presented and compared with those of the conventional method","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"122 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133879956","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
A novel approach for short-term hydrothermal scheduling using hybrid technique 一种基于混合技术的短期热液调度新方法
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632593
C. Nallasivan, D. Suman, Joseph Henry, S. Ravichandran
{"title":"A novel approach for short-term hydrothermal scheduling using hybrid technique","authors":"C. Nallasivan, D. Suman, Joseph Henry, S. Ravichandran","doi":"10.1109/POWERI.2006.1632593","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632593","url":null,"abstract":"The short-term hydrothermal co-ordination of power system, which is a large scale, combinatorial and nonlinear optimization problem has been extensively studied because of its significant economical impact. In this paper an effective short-term hydrothermal scheduling algorithm based on a hybrid evolutionary and a conventional technique is proposed. In the algorithm the thermal units on the system are represented by an equivalent unit. The power balance constraints, total water discharge constraints, reservoir volume constraints and constraints on operating limits of the equivalent thermal and hydro units are taken into account. The proposed method is developed in such a way that a standard adaptive evolutionary programming method is acting as a base level search and it directs the search towards the optimum region. Thereafter local optimization by direct search and systematic reduction in size of search region method is next employed to do fine tuning. The algorithm is demonstrated through an example of standard test system with a hydro plant and an equivalent thermal plant for a time schedule of six 12-hour intervals. The results are examined to validate the effectiveness of the algorithm","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134145878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 25
Fuzzy FPGA based captive power management 基于模糊FPGA的自备电源管理
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632554
Satvir Singh, J. Saini
{"title":"Fuzzy FPGA based captive power management","authors":"Satvir Singh, J. Saini","doi":"10.1109/POWERI.2006.1632554","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632554","url":null,"abstract":"The use of captive power is on the rise across the globe. In India alone, the estimated capacity of captive power plants is nearly 20,000 MW and most of the practical power plants are run sub-optimally by operators (albeit experienced ones). This calls for low-cost dedicated automatic controllers for the efficient management of captive power. Some studies have been reported in recent literature for the power management of islanded power plants, ad hoc network etc., but most studies are confined to computer simulations only. This paper reports a novel practical implementation of a dedicated real-time fuzzy logic controller on a low cost field programmable gate array chip for the management of 125 kW of captive power available from a medium capacity diesel generator set. A college campus has been chosen as the site for this implementation since it represents requirements typically suited for captive power use","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131893793","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A novel load flow approach for voltage stability index calculation and adjustment of static VAR compensator parameters 一种新的电压稳定指标计算及静态无功补偿器参数调整的潮流方法
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632622
M. Sailaja Kumari, M. Sydulu
{"title":"A novel load flow approach for voltage stability index calculation and adjustment of static VAR compensator parameters","authors":"M. Sailaja Kumari, M. Sydulu","doi":"10.1109/POWERI.2006.1632622","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632622","url":null,"abstract":"The location of SVC (static VAR compensator) and other types of shunt compensating devices for voltage support is an important practical question. This paper presents a new decoupled-quadratic load flow (DQLF) approach for adjustment of parameters of SVC. The DQLF model can calculate effectively the SVC susceptance and resulting firing angle using a simple quadratic equation derived using real and reactive power injections at the SVC bus. The resulting quadratic equation, can easily evaluate system voltage stability margin. The model makes use of conventional fast decoupled load flow (FDLF) algorithm for calculation of voltage phase angle corrections. The proposed approach eliminates the formation and modification of B\" matrix in FDLF models and offers considerable saving in the execution times. It is found to be very reliable for Q-adjusted studies and ill-conditioned cases. The DQLF model offers 50% faster convergence than FDLF model, when applied to large systems, having a large number of generator buses. The validity of the proposed algorithm for SVC parameter adjustment is tested on IEEE 14 bus system. The stability margins are evaluated using the proposed quadratic equation, and compared with traditional Q-V sensitivity model. The final parameters Bsvc and firing angle alpha obtained using DQLF model are compared with those obtained using Newton Raphson (NR) and FDLF models and found to be same","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130042838","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Generators contribution towards loads and line flows-a case study 发电机对负载和线路流的贡献—一个案例研究
2006 IEEE Power India Conference Pub Date : 2006-06-05 DOI: 10.1109/POWERI.2006.1632528
D. Thukaram, H. Khincha, B. Ravikumar, G. Yesuratnam
{"title":"Generators contribution towards loads and line flows-a case study","authors":"D. Thukaram, H. Khincha, B. Ravikumar, G. Yesuratnam","doi":"10.1109/POWERI.2006.1632528","DOIUrl":"https://doi.org/10.1109/POWERI.2006.1632528","url":null,"abstract":"In many parts of the world, the goal of electricity supply industries is always the introduction of competition and a lowering of the average consumer price. Because of this it has become much more important to be able to determine which generators are supplying a particular load, how much use each generator is making of a transmission line and what is generator's contribution to the system losses. In this paper a case study on generator contributions towards loads and transmission flows are illustrated with an equivalent 11-bus system, a part of Indian Southern Grid, based on the concepts of circuit flow directions, for normal and network contingency conditions","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133812615","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×