Metrology and Measurement Systems最新文献

筛选
英文 中文
Transition of emotions from the negatively excited state to positive unexcited state: an ERP perspective 情绪从消极兴奋状态到积极未兴奋状态的转变:ERP视角
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2022.140030
M. Singh, Mandeep Singh
{"title":"Transition of emotions from the negatively excited state to positive unexcited state: an ERP perspective","authors":"M. Singh, Mandeep Singh","doi":"10.24425/mms.2022.140030","DOIUrl":"https://doi.org/10.24425/mms.2022.140030","url":null,"abstract":"The cognitive aspects like perception, problem-solving, thinking, task performance, etc., are immensely influenced by emotions making it necessary to study emotions. The best state of emotion is the positive unexcitedstate,alsoknownastheHighValenceLowArousal(HVLA)stateoftheemotion.Thepsychologists endeavourtobringthesubjectsfromanegativelyexcitedstateofemotion(LowValenceHighArousalstate) toapositiveunexcitedstateofemotion(HighValenceLowArousalstate).Inthefirstpartofthisstudy, afour-classsubjectindependentemotionclassifierwasdevelopedwithanSVMpolynomialclassifier usingaverageEventRelatedPotential(ERP)anddifferentialaverageERPattributes.Thevisuallyevoked Electroencephalogram(EEG)signalswereacquiredfrom24subjects.Thefour-classclassificationaccuracy was83%usingaverageERPattributesand77%usingdifferentialaverageERPattributes.Inthesecond partofthestudy,themeditativeinterventionwasappliedto20subjectswhodeclaredthemselvesnegatively excited(inLowValenceHighArousalstateofemotion).TheEEGsignalswereacquiredbeforeandafter themeditativeintervention.Thefour-classsubjectindependentemotionclassifierdevelopedinStudy1 correctlyclassifiedthese20subjectstobeinanegativelyexcitedstateofemotion.Aftertheintervention,16 subjectsself-assessedthemselvestobeinapositiveunexcited(HVLA)stateofemotion(whichshowsthe interventionaccuracyof80%).Testingafour-classsubjectindependentemotionclassifierontheEEGdata acquiredafterthemeditativeinterventionvalidated13of16subjectsinapositiveunexcitedstate,yielding anaccuracyof81.3%.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44856429","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative studies of the optical absorption coefficient spectra in the implanted layers in silicon with the use of nondestructive spectroscopic techniques 利用无损光谱技术对硅注入层的光吸收系数光谱进行比较研究
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2020.132778
K. Dorywalski, Ł. Chrobak, M. Malinski
{"title":"Comparative studies of the optical absorption coefficient spectra in the implanted layers in silicon with the use of nondestructive spectroscopic techniques","authors":"K. Dorywalski, Ł. Chrobak, M. Malinski","doi":"10.24425/mms.2020.132778","DOIUrl":"https://doi.org/10.24425/mms.2020.132778","url":null,"abstract":"Thisworkpresentsresultsofcomparativestudiesoftheopticalabsorptioncoefficientspectraofionimplantedlayersinsilicon.Threenondestructiveandnoncontacttechniqueswereusedforthispurpose:spectroscopicellipsometry(SE),modulatedfreecarriersabsorption(MFCA)andthephotothermalradiometry(PTR).ResultsobtainedwiththeellipsometricmethodaretheproofofcorrectnessoftheresultsobtainedwiththeMFCAandPTRtechniques.Thesetechniquesareusuallyusedforinvestigationsofrecombinationparametersofsemiconductors.Theyarenotusedforinvestigationsoftheopticalparametersofsemiconductors.OpticalabsorptioncoefficientspectraofFe + and Ge + high energy and dose implanted layers in silicon, obtained with the three techniques, are presented and compared.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44907387","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A comparison between profile and areal surface roughness parameters 轮廓和面形表面粗糙度参数的比较
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2021.137133
Baofeng He, Siyuan Ding, Zhaoyao Shi
{"title":"A comparison between profile and areal surface roughness parameters","authors":"Baofeng He, Siyuan Ding, Zhaoyao Shi","doi":"10.24425/mms.2021.137133","DOIUrl":"https://doi.org/10.24425/mms.2021.137133","url":null,"abstract":"Surface roughness has an important influence on the service performance and life of parts. Areal surface roughness has the advantage of accurately and comprehensively characterizing surface microtopography. Understanding the relationship and distinction between profile and areal surface roughness is conducive to deepening the study of areal surface roughness and improving its application. In this paper, the concepts, development, and applications of surface roughness in the profile and the areal are summarized from the aspect of evaluation parameters. The relationships and differences between surface roughness in the profile and the areal are analyzed for each aspect, and future development trends are identified.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45093464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
An evaluation of the accuracy of inverter sync angle during the grid's disturbances 电网扰动时逆变器同步角精度的评估
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/MMS.2020.132780
W. Jarzyna, Dariusz Zieliński, K. Gopakumar
{"title":"An evaluation of the accuracy of inverter sync angle during the grid's disturbances","authors":"W. Jarzyna, Dariusz Zieliński, K. Gopakumar","doi":"10.24425/MMS.2020.132780","DOIUrl":"https://doi.org/10.24425/MMS.2020.132780","url":null,"abstract":"The grid-tied inverter synchronizes with the network on the basis of the instantaneous voltage phase angle. This angle is computed by the so-called synchronization algorithms. During grid disturbances, it is estimated with a certain accuracy, which varies for different disturbances and depends on the choice of algorithm. The tests presented here determine how to make an optimal selection of the synchronization algorithm. The research methods used are modeling, simulation and analysis of the results obtained. One of the most important outcomes is the determination of the root-mean-square sync error and its dynamics denotation. The research conclusions should be of particular interest to designers of distributed energy systems with a large number of inverter energy sources.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43223005","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
An arbitrary waveform synthesis structure with high sampling rate and low spurious 一种具有高采样率和低杂散的任意波形合成结构
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2022.140027
Wenhao Zhao, Shulin Tian, Guangkun Guo, Jiajing You, Qiong Wu, Ke Liu
{"title":"An arbitrary waveform synthesis structure with high sampling rate and low spurious","authors":"Wenhao Zhao, Shulin Tian, Guangkun Guo, Jiajing You, Qiong Wu, Ke Liu","doi":"10.24425/mms.2022.140027","DOIUrl":"https://doi.org/10.24425/mms.2022.140027","url":null,"abstract":"The arbitrary waveform generator is characterised by its flexible signal generation, high frequency resolution and rapid frequency switching speed and is wildly used in fields like communication, radar systems, quantum control, astronautics and biomedicine. With continuous development of technology, higher requirements are placed on to the arbitrary waveform generator. Sampling rate determines the bandwidth of the output signal, spurious-free dynamic range determines the quality of generated signal. Due to above, these two indicators’ improvement is vital. However, the existing waveform generation methods cannot generate signals with quality good enough due to their technical limitations, and in order to realize a high system sampling rate, to accomplish waveform generation process in FPGA, multipath parallel structure is needed. Therefore, we proposed a parallel waveform synthesis structure based on digital resampling, which fixed the problems existing in the current methods effectively and achieved a high sampling rate as well as high quality arbitrary waveform synthesis. We also built up an experimental test bench to validate the proposed structure.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42030031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Rotation and twist measurement using tilted fibre bragg gratings 利用倾斜光纤布拉格光栅测量旋转和扭曲
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/123893
P. Kisała, K. Skorupski, S. Cięszczyk, P. Panas, J. Klimek
{"title":"Rotation and twist measurement using tilted fibre bragg gratings","authors":"P. Kisała, K. Skorupski, S. Cięszczyk, P. Panas, J. Klimek","doi":"10.24425/123893","DOIUrl":"https://doi.org/10.24425/123893","url":null,"abstract":"The paper presents a method of measuring the angle of rotation and twist using a tilted fibre Bragg grating (TFBG) periodic structure with a tilt angle of 6◦, written into a single-mode optical fibre. It has been shown that the rotation of the sensor by 180◦ causes a change in the transmission coefficient from 0.5 to 0.84 at a wavelength of 1541.2 nm. As a result of measurements it was determined that the highest sensitivity can be obtained for angles from 30◦ to 70◦ in relation to the basic orientation. The change in the transmission spectrum occurs for cladding modes that change their intensity with the change in the polarization of light propagating through the grating. The same structure can also be used to measure the twist angle. The possibility of obtaining a TFBG twist by 200◦ over a length of 10 mm has been proved. This makes it possible to monitor both the angle of rotation and the twist of an optical fibre with the fabricated TFBG.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44247087","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Rotary upgrading method and its experimental study of an inertially stabilized platform 惯性稳定平台的旋转提升方法及其实验研究
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/MMS.2019.130566
Rong Guo, Xueyun Wang, Jingjuan Zhang, Tianxiao Song
{"title":"Rotary upgrading method and its experimental study of an inertially stabilized platform","authors":"Rong Guo, Xueyun Wang, Jingjuan Zhang, Tianxiao Song","doi":"10.24425/MMS.2019.130566","DOIUrl":"https://doi.org/10.24425/MMS.2019.130566","url":null,"abstract":"Rotation modulation can significantly improve the navigation accuracies of an inertial navigation system (INS) and a strap-down configuration dominating in this type of INS. However, this style of construction is not a good scheme since it has no servo loop to counteract a vehicle manoeuvre. This paper proposes a rotary upgrading method for a rotational INS based on an inertially stabilized platform. The servo control loop is reconstructed on a four-gimbal platform, and it has the functions of providing both a level stability relative to the navigation frame and an azimuth rotation at a speed of 1.2◦/s. With the platform’s rotation, the observability and the convergence speed of the estimation for the initial alignment can be improved, as well as the biases of the gyroscopes and accelerometers be modulated into zero-mean periodic values. An open-loop initial alignment method is designed, and its detailed algorithms are delivered. The experiment result shows that the newly designed rotational INS has reached an accuracy of 0.38 n mile/h (CEP, circular error probable). The feasibility and engineering applicability of the designed scheme have been validated.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44278607","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Susceptometer in soil magnetic susceptibility studies 土壤磁化率研究中的电纳计
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2022.138550
Sławomir Janas, T. Magiera, T. Szumiata
{"title":"Susceptometer in soil magnetic susceptibility studies","authors":"Sławomir Janas, T. Magiera, T. Szumiata","doi":"10.24425/mms.2022.138550","DOIUrl":"https://doi.org/10.24425/mms.2022.138550","url":null,"abstract":"This work presents a method for measuring the magnetic susceptibility of soil samples based on interactions of magnetic particles contained in a tested sample with a weighed permanent magnet placed in the balance mechanical design. The MYA 2.4Y microbalance manufactured by Radwag Wagi Elektroniczne, Poland, was used to perform mass measurements. The weighing system was adjusted for mass indication using a certified mass standard, and for magnetic susceptibility indication using a certified magnetic susceptibility standard. The volume of each analysed soil sample was 3.93 cm 3 and was similar to the volume and the size of the magnetic susceptibility standard. The research was carried out for 10 soil samples with a magnetic susceptibility range varying from 20 to 1600 × 10 − 8 m 3 kg − 1 . The soil samples contained technogenic magnetic particles and particles of natural magnetite of geogenic origin. The study was performed for a field of 2 mT.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43481169","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Sensitivity analysis of a new approach to photovoltaic parameters extraction based on the total least squares method 基于总最小二乘法的光伏参数提取新方法的灵敏度分析
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2021.137707
Oumaima Mesbahi, M. Tlemçani, F. Janeiro, Abdeloawahed Hajjaji, K. Kandoussi
{"title":"Sensitivity analysis of a new approach to photovoltaic parameters extraction based on the total least squares method","authors":"Oumaima Mesbahi, M. Tlemçani, F. Janeiro, Abdeloawahed Hajjaji, K. Kandoussi","doi":"10.24425/mms.2021.137707","DOIUrl":"https://doi.org/10.24425/mms.2021.137707","url":null,"abstract":"The degradation of photovoltaic modules and their subsequent loss of performance has a serious impact on the total energy generation potential. The lack of real-time information on the output power leads to additional losses since the panels may not be operating at their optimal point. To understand the behaviour, numerically simulate the characteristics and identify the optimal operating point of a photovoltaic cell, the parameters of an equivalent electrical circuit must first be identified. The aim of this work is to develop a total least-squares based algorithm which can identify those parameters from the output voltage and current measurements, taking into consideration the uncertainties on both measured quantities. This work presents a comparative study of the Ordinary Least Squares (OLS) and Total Least Squares (TLS) approaches to the estimation of the parameters of a photovoltaic cell.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43912065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Uncertainty of pressure measurement in a single-bed adsorber 单床吸附器压力测量的不确定度
IF 1 4区 工程技术
Metrology and Measurement Systems Pub Date : 2023-07-20 DOI: 10.24425/mms.2022.138544
M. Neska, T. Opara
{"title":"Uncertainty of pressure measurement in a single-bed adsorber","authors":"M. Neska, T. Opara","doi":"10.24425/mms.2022.138544","DOIUrl":"https://doi.org/10.24425/mms.2022.138544","url":null,"abstract":"An adsorber in which sorption processes occur is one of the key components of an adsorption chiller. Precise real-time monitoring of and supervision over these processes are particularly important to ensure their proper execution. The article describes the experimental stand used for the measurement of the adsorber’s operating parameters and analyses pressure measurement uncertainties, taking into account the impact of the temperature on the test system filled with the adsorbent in the form of silica gel, while concurrently considering the influence of other factors (e.g. the environment, the A/A, and A/D conversion, or data processing) on measurement uncertainties. A complex analysis of uncertainties was carried out, including the results of the statistical analysis of the measurement data obtained from long-term experimental tests of the object and the uncertainties of the pressure measuring chain by the type B method, involving the consideration of interactions between the system components and the temperature impact on the propagation of uncertainties. As part of the analysis, the characteristic stages of the data collection and processing operations related to the sampling rate and measurement intervals were separated. The article presents the prototype test stand and original pressure measurement system for the verification of a single-bed adsorber working below 10 hPa.The novel construction of a single-bed adsorber was used as a test object. Furthermore, in this paper, the developed algorithm of the research method implemented in the system was discussed and positively verified.","PeriodicalId":18394,"journal":{"name":"Metrology and Measurement Systems","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43368550","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信