Journal of Research of the National Institute of Standards and Technology最新文献

筛选
英文 中文
Atomic Model Structure of the NIST Monoclonal Antibody (NISTmAb) Reference Material. NIST单克隆抗体(NISTmAb)标准物质的原子模型结构。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2021-01-01 DOI: 10.6028/jres.126.012
Christina Bergonzo, D Travis Gallagher
{"title":"Atomic Model Structure of the NIST Monoclonal Antibody (NISTmAb) Reference Material.","authors":"Christina Bergonzo, D Travis Gallagher","doi":"10.6028/jres.126.012","DOIUrl":"https://doi.org/10.6028/jres.126.012","url":null,"abstract":"As monoclonal antibodies have become a vital resource in medicine, knowledge of\u0000 their complex molecular structures has increased in importance. Thousands of antibody\u0000 components (Fab and Fc fragments) are described in the Protein Data Bank. Whole\u0000 antibodies have been imaged by electron microscopy methods and in a few cases,\u0000 crystallized. The central hinge lacks a unique stable conformation and its dynamic\u0000 properties are important to antibody function. Monte Carlo and molecular dynamics\u0000 simulations and small-angle scattering methods have been used to analyze the wide range\u0000 of configurations that are accessible to antibodies in solution. In order to support the\u0000 development of antibody-based medicines, the National Institute of Standards and\u0000 Technology (NIST) has released an extensively characterized IgG1κ monoclonal antibody\u0000 (mAb), called the NISTmAb Reference Material 8671. To facilitate modeling of whole\u0000 antibodies we now report the construction of an all-atom 3-D model of the NISTmAb.","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9681211/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10431081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
The NMR Spectral Measurement Database: A System for Organizing and Accessing NMR Spectra of Therapeutic Proteins. 核磁共振光谱测量数据库:组织和获取治疗蛋白核磁共振光谱的系统。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2021-01-01 DOI: 10.6028/jres.126.035
Niksa Blonder, Frank Delaglio
{"title":"The NMR Spectral Measurement Database: A System for Organizing and Accessing NMR Spectra of Therapeutic Proteins.","authors":"Niksa Blonder, Frank Delaglio","doi":"10.6028/jres.126.035","DOIUrl":"https://doi.org/10.6028/jres.126.035","url":null,"abstract":"The Nuclear Magnetic Resonance Spectral Measurement Database (NMR-SMDB) was\u0000 developed for the purpose of organizing and searching NMR spectral data of protein\u0000 therapeutics, linking spectra to corresponding sample information and enabling quick\u0000 access to full datasets and entire studies. In addition to supporting internal research\u0000 at the National Institute of Standards and Technology (NIST), the system could\u0000 facilitate data access to stakeholders outside of NIST, and future versions of the\u0000 database software itself could be installed by others for their own data storage and\u0000 retrieval.","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9683039/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10431078","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the FcγRIa (CD64) Receptor. IgG1糖型及其与FcγRIa (CD64)受体相互作用的研究
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2021-01-01 DOI: 10.6028/jres.126.010
Kyle W Anderson, Kerry Scott, Ioannis L Karageorgos, Elyssia S Gallagher, Venkata S Tayi, Michael Butler, Jeffrey W Hudgens
{"title":"Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the FcγRIa (CD64) Receptor.","authors":"Kyle W Anderson, Kerry Scott, Ioannis L Karageorgos, Elyssia S Gallagher, Venkata S Tayi, Michael Butler, Jeffrey W Hudgens","doi":"10.6028/jres.126.010","DOIUrl":"https://doi.org/10.6028/jres.126.010","url":null,"abstract":"This document presents hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, FcγRIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9681196/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10368123","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Development of the Advanced Encryption Standard. 高级加密标准的发展。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2021-01-01 DOI: 10.6028/jres.126.024
Miles E Smid
{"title":"Development of the Advanced Encryption Standard.","authors":"Miles E Smid","doi":"10.6028/jres.126.024","DOIUrl":"https://doi.org/10.6028/jres.126.024","url":null,"abstract":"<p><p>Strong cryptographic algorithms are essential for the protection of stored and transmitted data throughout the world. This publication discusses the development of Federal Information Processing Standards Publication (FIPS) 197, which specifies a cryptographic algorithm known as the Advanced Encryption Standard (AES). The AES was the result of a cooperative multiyear effort involving the U.S. government, industry, and the academic community. Several difficult problems that had to be resolved during the standard's development are discussed, and the eventual solutions are presented. The author writes from his viewpoint as former leader of the Security Technology Group and later as acting director of the Computer Security Division at the National Institute of Standards and Technology, where he was responsible for the AES development.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9682931/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10431079","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Erratum: Improved First-Principles Calculation of the Third Virial Coeffcient of Helium. 订正:氦的第三维里系数的改进第一性原理计算。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2020-01-01 DOI: 10.6028/jres.125.019
Giovanni Garberoglio, Michael R Moldover, Allan H Harvey
{"title":"Erratum: Improved First-Principles Calculation of the Third Virial Coeffcient of Helium.","authors":"Giovanni Garberoglio,&nbsp;Michael R Moldover,&nbsp;Allan H Harvey","doi":"10.6028/jres.125.019","DOIUrl":"https://doi.org/10.6028/jres.125.019","url":null,"abstract":"<p><p>[This corrects the article on p. 729 in vol. 116.].</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.6028/jres.125.019","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10374117","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Shock Measurements Based on Pendulum Excitation and Laser Doppler Velocimetry: Primary Calibration by SI-Traceable Distance Measurements. 基于钟摆激励和激光多普勒测速的冲击测量:si可追溯距离测量的初步校准。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2020-01-01 DOI: 10.6028/jres.125.011
Muhammad Y Afridi, Jon Geist, Michael Gaitan
{"title":"Shock Measurements Based on Pendulum Excitation and Laser Doppler Velocimetry: Primary Calibration by SI-Traceable Distance Measurements.","authors":"Muhammad Y Afridi,&nbsp;Jon Geist,&nbsp;Michael Gaitan","doi":"10.6028/jres.125.011","DOIUrl":"https://doi.org/10.6028/jres.125.011","url":null,"abstract":"<p><p>A new method is described to provide a primary calibration of shock measurements produced by a shock measurement system consisting of pendulum excitation and laser Doppler velocimetry. The method uses the laser Doppler velocimeter to determine the total distance traveled by a rigid block that slides along a Teflon (fluorocarbon) channel after being struck by a pendulum head, and the resulting distance is compared to the distance measured by an SI-traceable length measurement. The instantaneous velocity of the block is measured by the velocimeter and is used to calculate the displacement of the block by integrating the velocity data. The result is compared to the displacement measured using calibrated rulers and calipers. The method was applied to an independently calibrated commercial velocimeter for impact accelerations ranging from 2000 to 30,000 m/s2. The results of the independent mechanical displacement measurements agreed with those from the commercial velocimeter to within ±0.3 %, with better agreement above accelerations of order 10,000 m/s2 to within ±0.1 %. A conservative, upper-bound, uncertainty analysis included the effects of noise and other random errors, as well as type B estimates for systematic errors from occasional momentary demodulation failures (dropouts), use of a different number of rulers before and after shock distance measurement, and the relative frequency response of the velocimeter.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.6028/jres.125.011","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10619324","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Design Considerations to Improve Charpy Instrumented Strikers. 改进Charpy仪表打击器的设计考虑。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2020-01-01 DOI: 10.6028/jres.125.010
Nicholas Vlajic, Ako Chijioke, Enrico Lucon
{"title":"Design Considerations to Improve Charpy Instrumented Strikers.","authors":"Nicholas Vlajic,&nbsp;Ako Chijioke,&nbsp;Enrico Lucon","doi":"10.6028/jres.125.010","DOIUrl":"https://doi.org/10.6028/jres.125.010","url":null,"abstract":"<p><p>Instrumented impact testing allows the applicability of conventional Charpy tests to be extended toward assessing mechanical properties such as dynamic fracture toughness and dynamic tensile properties. In this work, we present design considerations for engineering instrumented strikers for Charpy V-notch impact testing. Specific attention is given to the mechanical and geometric features, as well as the placement of strain gauges and corresponding bridge circuits for instrumentation. These design considerations are intended to make the sensitivity invariant to the location and distribution of impact forces. The concepts presented in this work were applied to an actual instrumented striker, which was then statically calibrated. Data from this calibration indicate that the device has good repeatability, shows a linear response, and is relatively insensitive to impact location.</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704991/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10370314","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Immersion Coefficient for the Marine Optical Buoy (MOBY) Radiance Collectors. 海洋光学浮标(MOBY)辐射收集器的浸没系数。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2017-01-01 Epub Date: 2017-06-28 DOI: 10.6028/jres.122.031
Michael Feinholz, B Carol Johnson, Kenneth Voss, Mark Yarbrough, Stephanie Flora
{"title":"Immersion Coefficient for the Marine Optical Buoy (MOBY) Radiance Collectors.","authors":"Michael Feinholz,&nbsp;B Carol Johnson,&nbsp;Kenneth Voss,&nbsp;Mark Yarbrough,&nbsp;Stephanie Flora","doi":"10.6028/jres.122.031","DOIUrl":"https://doi.org/10.6028/jres.122.031","url":null,"abstract":"<p><p>The immersion coefficient accounts for the difference in responsivity for a radiometer placed in the air versus water or another medium. In this study, the immersion coefficients for the radiance collectors on the Marine Optical Buoy (MOBY) were modeled and measured. The experiment showed that the immersion coefficient for the MOBY radiance collectors agreed with a simple model using only the index of refraction for water and fused silica. With the results of this experiment, we estimate that the uncertainty in the current value of the immersion coefficient used in the MOBY project is 0.05 % (<i>k</i> = 1).</p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.6028/jres.122.031","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"35315729","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
The Importance of Dosimetry Standardization in Radiobiology. 放射生物学中剂量学标准化的重要性。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2013-12-30 eCollection Date: 2013-01-01 DOI: 10.6028/jres.118.021
Marc Desrosiers, Larry DeWerd, James Deye, Patricia Lindsay, Mark K Murphy, Michael Mitch, Francesca Macchiarini, Strahinja Stojadinovic, Helen Stone
{"title":"The Importance of Dosimetry Standardization in Radiobiology.","authors":"Marc Desrosiers,&nbsp;Larry DeWerd,&nbsp;James Deye,&nbsp;Patricia Lindsay,&nbsp;Mark K Murphy,&nbsp;Michael Mitch,&nbsp;Francesca Macchiarini,&nbsp;Strahinja Stojadinovic,&nbsp;Helen Stone","doi":"10.6028/jres.118.021","DOIUrl":"https://doi.org/10.6028/jres.118.021","url":null,"abstract":"<p><p>Radiation dose is central to much of radiobiological research. Precision and accuracy of dose measurements and reporting of the measurement details should be sufficient to allow the work to be interpreted and repeated and to allow valid comparisons to be made, both in the same laboratory and by other laboratories. Despite this, a careful reading of published manuscripts suggests that measurement and reporting of radiation dosimetry and setup for radiobiology research is frequently inadequate, thus undermining the reliability and reproducibility of the findings. To address these problems and propose a course of action, the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Diseases (NIAID), and the National Institute of Standards and Technology (NIST) brought together representatives of the radiobiology and radiation physics communities in a workshop in September, 2011. The workshop participants arrived at a number of specific recommendations as enumerated in this paper and they expressed the desirability of creating dosimetry standard operating procedures (SOPs) for cell culture and for small and large animal experiments. It was also felt that these SOPs would be most useful if they are made widely available through mechanism(s) such as the web, where they can provide guidance to both radiobiologists and radiation physicists, be cited in publications, and be updated as the field and needs evolve. Other broad areas covered were the need for continuing education through tutorials at national conferences, and for journals to establish standards for reporting dosimetry. This workshop did not address issues of dosimetry for studies involving radiation focused at the sub-cellular level, internally-administered radionuclides, biodosimetry based on biological markers of radiation exposure, or dose reconstruction for epidemiological studies. </p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2013-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.6028/jres.118.021","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34201815","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 92
Precise Measurement of Lunar Spectral Irradiance at Visible Wavelengths. 可见光波长下月球光谱辐照度的精确测量。
IF 1.5 4区 工程技术
Journal of Research of the National Institute of Standards and Technology Pub Date : 2013-10-29 eCollection Date: 2013-01-01 DOI: 10.6028/jres.118.020
C E Cramer, K R Lykke, J T Woodward, A W Smith
{"title":"Precise Measurement of Lunar Spectral Irradiance at Visible Wavelengths.","authors":"C E Cramer, K R Lykke, J T Woodward, A W Smith","doi":"10.6028/jres.118.020","DOIUrl":"10.6028/jres.118.020","url":null,"abstract":"<p><p>We report a measurement of lunar spectral irradiance with an uncertainty below 1 % from 420 nm to 1000 nm. This measurement uncertainty meets the stability requirement for many climate data records derived from satellite images, including those for vegetation, aerosols, and snow and ice albedo. It therefore opens the possibility of using the Moon as a calibration standard to bridge gaps in satellite coverage and validate atmospheric retrieval algorithms. Our measurement technique also yields detailed information about the atmosphere at the measurement site, suggesting that lunar observations are a possible solution for aerosol monitoring during the polar winter and can provide nighttime measurements to complement aerosol data collected with sun photometers. Our measurement, made with a novel apparatus, is an order of magnitude more accurate than the previous state-of-the-art and has continuous spectral coverage, removing the need to interpolate between filter passbands. </p>","PeriodicalId":17039,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.5,"publicationDate":"2013-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4487308/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"34200338","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信