Journal of Chromatography B: Biomedical Sciences and Applications最新文献

筛选
英文 中文
Fluorometric determination of dl-fenfluramine, dl-norfenfluramine and phentermine in plasma by achiral and chiral high-performance liquid chromatography 非手性和手性高效液相色谱法测定血浆中dl-芬氟拉明、dl-诺芬氟拉明和芬特明
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00368-1
Amal Kaddoumi, Mihoko N Nakashima, Kenichiro Nakashima
{"title":"Fluorometric determination of dl-fenfluramine, dl-norfenfluramine and phentermine in plasma by achiral and chiral high-performance liquid chromatography","authors":"Amal Kaddoumi,&nbsp;Mihoko N Nakashima,&nbsp;Kenichiro Nakashima","doi":"10.1016/S0378-4347(01)00368-1","DOIUrl":"10.1016/S0378-4347(01)00368-1","url":null,"abstract":"<div><p>High-performance liquid chromatography (HPLC) with fluorescence detection has been developed for the simultaneous determination of sympathomimetic amines including ephedrine, norephedrine, 2-phenylethylamine, 4-bromo-2,5-dimethoxyphenylethylamine, phentermine (Phen) and <span>dl</span>-fenfluramine (Fen) in spiked human plasma. Furthermore, an enantioselective HPLC method for the separation of <span>d</span>-Fen (dexfenfluramine) and <span>l</span>-Fen (levofenfluramine) in addition to their active metabolites <span>d</span>- and <span>l</span>-norfenfluramine (Norf) is described. The detection was achieved at emission wavelength of 430 nm with excitation wavelength of 325 nm for both methods. The analytes were extracted from plasma (100 μl) at pH 10.6 with ethyl acetate using fluoxetine as the internal standard. The extracts were evaporated and derivatized with the fluorescence reagent 4-(4,5-diphenyl-1<em>H</em>-imidazole-2-yl)benzoyl chloride in the presence of carbonate buffer (pH 9.0). A gradient separation was achieved on a C<sub>18</sub> column for the achiral separation or on a Chiralcel OD-R column for the chiral separation. The methods were fully validated, and shown to have excellent linearity, sensitivity and precision. The chiral method has been applied for the determination of <span>d</span>- and <span>l</span>-enantiomers of Fen and Norf, in addition to Phen in rat plasma after an intraperitoneal administration of <span>dl</span>-Fen and Phen, simultaneously.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 79-90"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00368-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82601714","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 25
Determination of mycophenolic acid and its phenol glucuronide metabolite in human plasma and urine by high-performance liquid chromatography 高效液相色谱法测定人血浆和尿液中霉酚酸及其酚葡萄糖醛酸代谢物
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00354-1
Kamonthip Wiwattanawongsa , Erin L Heinzen, Daniel C Kemp, Robert E Dupuis, Philip C Smith
{"title":"Determination of mycophenolic acid and its phenol glucuronide metabolite in human plasma and urine by high-performance liquid chromatography","authors":"Kamonthip Wiwattanawongsa ,&nbsp;Erin L Heinzen,&nbsp;Daniel C Kemp,&nbsp;Robert E Dupuis,&nbsp;Philip C Smith","doi":"10.1016/S0378-4347(01)00354-1","DOIUrl":"10.1016/S0378-4347(01)00354-1","url":null,"abstract":"<div><p>Simultaneous determination of mycophenolic acid (MPA) and mycophenolate phenol glucuronide (MPAG) in plasma and urine was accomplished by isocratic HPLC with UV detection. Plasma was simply deproteinated with acetonitrile and concentrated, whereas urine was diluted prior to analysis. Linearity was observed from 0.2 to 50 μg/ml for both MPA and MPAG in plasma and from 1 to 50 μg/ml of MPA and 5 to 2000 μg/ml MPAG in urine with extraction recovery from plasma greater than 70%. Detection limits using 0.25 ml plasma were 0.080 and 0.20 μg/ml for MPA and MPAG, respectively. The method is more rapid and simple than previous assays for MPA and MPAG in biological fluids from patients.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 35-45"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00354-1","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74062162","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 45
Comparison of the capabilities of liquid isoelectric focusing–one-dimensional nonporous silica reversed-phase liquid chromatography–electrospray ionization time-of-flight mass spectrometry and liquid isoelectric focusing–one-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis mass mapping for the analysis of intact protein molecular masses 液体等电聚焦-一维无孔二氧化硅反相液相色谱-电喷雾电离飞行时间质谱法与液体等电聚焦-一维十二烷基硫酸钠聚丙烯酰胺凝胶电泳质谱图分析完整蛋白质分子质量的能力比较
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00382-6
Daniel B Wall, Stephen J Parus, David M Lubman
{"title":"Comparison of the capabilities of liquid isoelectric focusing–one-dimensional nonporous silica reversed-phase liquid chromatography–electrospray ionization time-of-flight mass spectrometry and liquid isoelectric focusing–one-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis mass mapping for the analysis of intact protein molecular masses","authors":"Daniel B Wall,&nbsp;Stephen J Parus,&nbsp;David M Lubman","doi":"10.1016/S0378-4347(01)00382-6","DOIUrl":"10.1016/S0378-4347(01)00382-6","url":null,"abstract":"<div><p>Nonporous silica reversed-phase HPLC coupled to electrospray ionization with on-line time-of-flight mass spectrometric detection (NPS-RP-HPLC–ESI-TOF-MS) is shown to be an effective liquid phase method for obtaining the molecular masses of proteins from pH fractionated cellular lysates where the method is capable of generating the same banding patterns typically observed using gel phase one-dimensional sodium dodecyl sulfate–polyacrylamide gel electrophoresis. The liquid-phase mass spectrometry-based method provides a mass accuracy of at least 150 ppm, with 4000 mass resolution and provides improved sensitivity as the protein molecular mass (MW) decreases. The liquid and gel phase methods are shown to be complementary in terms of their mass range but the liquid phase method has the advantage over the gel method in that the analysis times are 50 times shorter, the mass accuracy is 70 times better and the resolution is 130 times higher. The liquid phase method is shown to be more effective for detection of proteins below 40 kDa, while the gel phase separation can access many more proteins, including more hydrophobic proteins, at increasing MW.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 139-148"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00382-6","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"84899541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Automated chromatographic system for the simultaneous measurement of plasma pregnenolone and 17-hydroxypregnenolone by radioimmunoassay 用放射免疫法同时测定血浆孕烯醇酮和17-羟基孕烯醇酮的自动色谱系统
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00373-5
F.G Riepe, S Wonka, C.-J Partsch, W.G Sippell
{"title":"Automated chromatographic system for the simultaneous measurement of plasma pregnenolone and 17-hydroxypregnenolone by radioimmunoassay","authors":"F.G Riepe,&nbsp;S Wonka,&nbsp;C.-J Partsch,&nbsp;W.G Sippell","doi":"10.1016/S0378-4347(01)00373-5","DOIUrl":"10.1016/S0378-4347(01)00373-5","url":null,"abstract":"<div><p>A new, simple, rapid and highly practicable automated chromatographic system for the separation, and a sensitive radioimmunoassay system for the subsequent measurement of pregnenolone and 17-hydroxypregnenolone has been developed. Pregnenolone and 17-hydroxypregnenolone were extracted with methylene chloride and separated from cross-reacting steroids by mechanised Sephadex-LH20 multi-column chromatography. Anti-pregnenolone and anti-17-hydroxypregnenolone were obtained by immunising rabbits with pregnenolone-20-oxime-BSA and 17-hydroxypregnenolone-20-oxime-BSA. The lower detection limit of the assay is 0.15 and 0.28 nmol/l for pregnenolone and 17-hydroxypregnenolone, respectively. Normal values for this assay in young male adults, in adult females, and in prepubertal boys and girls were established as a basis for the functional diagnosis of androgen excess syndromes/steroidogenesis defects.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 99-106"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00373-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72873729","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
High-performance liquid chromatographic analysis for the determination of a novel polymer-bound camptothecin derivative (MAG-camptothecin) and free camptothecin in human plasma 高效液相色谱法测定人血浆中新型聚合物结合喜树碱衍生物(mag -喜树碱)和游离喜树碱
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00391-7
Nadja E Schoemaker , Enrico Frigerio , Daniela Fraier , Jan H.M Schellens , Hilde Rosing , Sindy Jansen , Jos H Beijnen
{"title":"High-performance liquid chromatographic analysis for the determination of a novel polymer-bound camptothecin derivative (MAG-camptothecin) and free camptothecin in human plasma","authors":"Nadja E Schoemaker ,&nbsp;Enrico Frigerio ,&nbsp;Daniela Fraier ,&nbsp;Jan H.M Schellens ,&nbsp;Hilde Rosing ,&nbsp;Sindy Jansen ,&nbsp;Jos H Beijnen","doi":"10.1016/S0378-4347(01)00391-7","DOIUrl":"10.1016/S0378-4347(01)00391-7","url":null,"abstract":"<div><p>A selective HPLC assay is described for the determination of free and total (free plus polymer-bound) camptothecin (CPT) in human plasma after administration of the anti-tumor drug MAG-CPT (polymer bound camptothecin). Total CPT levels were determined after hydrolysis and free CPT was extracted from acidified plasma using Oasis solid-phase extraction material. Extracts were analyzed on a Zorbax SB-C<sub>8</sub> analytical column, using a mixture of acetonitrile–25 m<em>M</em> phosphate buffer (pH 4.0) as the eluent. Detection was performed fluorimetrically. Concentrations of polymer-bound CPT were calculated by subtraction of free from total CPT. The lower limits of quantitation of the methods were 100 ng/ml for total and 1.0 ng/ml for free CPT using 50 μl and 250 μl plasma, respectively. Special attention was paid to the stability of the analytes. The presented method was successfully applied in a clinical pharmacokinetic study in our institute.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 173-183"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00391-7","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74766304","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Simultaneous determination of retinol, β-carotene and α-tocopherol in adipose tissue by high-performance liquid chromatography 高效液相色谱法同时测定脂肪组织中视黄醇、β-胡萝卜素和α-生育酚
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00349-8
S Casal, B Macedo, M.B.P.P Oliveira
{"title":"Simultaneous determination of retinol, β-carotene and α-tocopherol in adipose tissue by high-performance liquid chromatography","authors":"S Casal,&nbsp;B Macedo,&nbsp;M.B.P.P Oliveira","doi":"10.1016/S0378-4347(01)00349-8","DOIUrl":"10.1016/S0378-4347(01)00349-8","url":null,"abstract":"<div><p>A method is described for evaluation of fat-soluble vitamin in human adipose tissue with the aim to obtain, accurately and within the shortest analysis time, a time-integrated measure of exposure to vitamins from the diet. Fat tissue was deproteinized with ethanol and extracted with <em>n</em>-hexane. Normal-phase HPLC was performed in a Lichrosorb Si60 column with a gradient of <em>n</em>-hexane–2-propanol at 1 ml/min. Detection was accomplished using a diode-array system (for retinol and β-carotene) in series with a fluorescence detector (α-tocopherol). The method was validated and applied to human adipose tissue in a total of 140 subjects. The mean contents found were 0.43, 0.84, 240.3 μg/g for retinol, β-carotene and α-tocopherol, respectively. The method is sensitive enough for detecting the compounds in 1.6 mg of adipose tissue considering the lowest concentration found.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 1-8"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00349-8","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"78673484","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 37
Determination of cyclosporin A in human and mouse plasma by reversed-phase high-performance liquid chromatography 反相高效液相色谱法测定人和小鼠血浆中环孢素A的含量
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00389-9
Heleen A. Bardelmeijer , Mariët Ouwehand , Jos H. Beijnen , Jan H.M. Schellens , Olaf van Tellingen
{"title":"Determination of cyclosporin A in human and mouse plasma by reversed-phase high-performance liquid chromatography","authors":"Heleen A. Bardelmeijer ,&nbsp;Mariët Ouwehand ,&nbsp;Jos H. Beijnen ,&nbsp;Jan H.M. Schellens ,&nbsp;Olaf van Tellingen","doi":"10.1016/S0378-4347(01)00389-9","DOIUrl":"10.1016/S0378-4347(01)00389-9","url":null,"abstract":"<div><p>An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μ<em>M</em>. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μ<em>M</em> using 500 μl of human plasma and 0.28 μ<em>M</em> using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 201-206"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00389-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81508464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Development of a high-performance liquid chromatographic method for bioanalytical applications with sulpiride 高效液相色谱法在舒必利生物分析中的应用
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00387-5
Ming-Chuan Huang , Hsiu-O Ho , Geng-Cheng Yeh , Wen-Ting Ke , Li-Chin Lin , T.-M Bruce Hsu , Ching-Cheng Kao , Ming-Thau Sheu
{"title":"Development of a high-performance liquid chromatographic method for bioanalytical applications with sulpiride","authors":"Ming-Chuan Huang ,&nbsp;Hsiu-O Ho ,&nbsp;Geng-Cheng Yeh ,&nbsp;Wen-Ting Ke ,&nbsp;Li-Chin Lin ,&nbsp;T.-M Bruce Hsu ,&nbsp;Ching-Cheng Kao ,&nbsp;Ming-Thau Sheu","doi":"10.1016/S0378-4347(01)00387-5","DOIUrl":"10.1016/S0378-4347(01)00387-5","url":null,"abstract":"<div><p>An improved HPLC method using a silica gel column with fluorescence detection (excitation at 300 nm and emission at 365 nm) was developed for the determination of sulpiride concentrations in plasma. Analysis of sulpiride in plasma samples was simplified by a one-step liquid–liquid extraction after alkaline treatment of only 1 ml of plasma. The low limit of quantitation was 20 ng/ml with a coefficient of variation of less than 20%. A linear range was found from 20 to 1500 ng/ml. This HPLC method was validated with the precision for inter-day and intra-day runs being 0.36–8.01% and 0.29–5.25%, respectively, and the accuracy (standard deviation of mean, SD) for inter-day and intra-day runs being −1.58 to 5.02% and −2.14 to 5.21%, respectively. Bioequivalence of the two products was evaluated in 12 normal healthy male volunteers in a single-dose, two-period, two-sequence, two-treatment cross-over study. Sulpiride plasma concentrations were analyzed with this validated HPLC method. Results demonstrated that the two tablet formulations of sulpiride appear to be bioequivalent.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 157-163"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00387-5","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81797279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 34
Sensitive liquid chromatographic assay for the basic DNA intercalator (N,N-dimethylaminoethyl)-9-amino-5-methylacridine-4-carboxamide and its nitroarylmethyl quaternary prodrugs in biological samples 生物样品中碱性DNA插入剂(N,N-二甲氨基乙基)-9-氨基-5-甲基吖啶-4-羧酰胺及其硝基甲基季前药的灵敏液相色谱分析
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00381-4
Dianne M Ferry, Pierre L van Zijl, William R Wilson
{"title":"Sensitive liquid chromatographic assay for the basic DNA intercalator (N,N-dimethylaminoethyl)-9-amino-5-methylacridine-4-carboxamide and its nitroarylmethyl quaternary prodrugs in biological samples","authors":"Dianne M Ferry,&nbsp;Pierre L van Zijl,&nbsp;William R Wilson","doi":"10.1016/S0378-4347(01)00381-4","DOIUrl":"10.1016/S0378-4347(01)00381-4","url":null,"abstract":"<div><p>Nitroarylmethyl quaternary (NMQ) ammonium salts of the basic DNA intercalator AMAC (<em>N</em>,<em>N</em>-dimethylaminoethyl-9-amino-5-methylacridine-4-carboxamide) are of interest as anticancer prodrugs. A sensitive HPLC assay has been developed for quantitation of AMAC and its NMQ prodrugs in cultured cells, plasma and tissue. Recovery of the prodrugs, without conversion to AMAC, was achieved using extraction in alkaline acetonitrile followed by immediate reneutralisation. Reversed-phase HPLC with fluorescence detection gave a detection limit of 3 fmol for AMAC, with linearity to 20 nmol (using diode array absorbance at high concentrations). This assay was used to measure cellular uptake, and hypoxic metabolism to AMAC, of three NMQ-AMAC prodrugs.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 149-156"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00381-4","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88871880","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Identification of phase I and phase II metabolites of ketobemidone in patient urine using liquid chromatography–electrospray tandem mass spectrometry 用液相色谱-电喷雾串联质谱法鉴定患者尿液中酮贝酮的I期和II期代谢物
Journal of Chromatography B: Biomedical Sciences and Applications Pub Date : 2001-11-05 DOI: 10.1016/S0378-4347(01)00375-9
Ingela Sundström , Ulf Bondesson , Mikael Hedeland
{"title":"Identification of phase I and phase II metabolites of ketobemidone in patient urine using liquid chromatography–electrospray tandem mass spectrometry","authors":"Ingela Sundström ,&nbsp;Ulf Bondesson ,&nbsp;Mikael Hedeland","doi":"10.1016/S0378-4347(01)00375-9","DOIUrl":"10.1016/S0378-4347(01)00375-9","url":null,"abstract":"<div><p>Ketobemidone and five of its phase I metabolites were identified in the urine of four patients post intravenous administration of Ketogan Novum<sup>®</sup>. Furthermore, indications of the presence of the glucuronide conjugates of ketobemidone and norketobemidone is presented. Both hydrolyzed (β-glucuronidase) and unhydrolyzed human urine was extracted on a mixed-mode slightly polar cation-exchange SPEC cartridge prior to analysis with LC–ESI-MS–MS. The phase I metabolites were identified by comparison of their daughter spectra with those of synthesized standards. The glucuronides were identified by their molecular mass and interpretation of the daughter spectra, as no standards were available for these compounds.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 121-131"},"PeriodicalIF":0.0,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00375-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90654482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信