A. Borsoi, S. Collepardi, L. Coppola, R. Troli, M. Collepardi
{"title":"Sulfate Attack on Blended Portland Cements","authors":"A. Borsoi, S. Collepardi, L. Coppola, R. Troli, M. Collepardi","doi":"10.14359/5763","DOIUrl":"https://doi.org/10.14359/5763","url":null,"abstract":"Paste and mortar specimens were manufactured by using ordinary portland cement (OPC), C3A-free portland cement, slag cement and pozzolan cement. A carbonaceous or siliceous filler (10% by cement weight) was blended with each of the above portland cements. Limestone or quartz sands were used for mortar mixtures. Four different water-cement ratios (w/c) were adopted: 0.55, 0.50, 0.45, and 0.40. After a 28-day wet curing, paste and mortar specimens were immersed in magnesium sulfate aqueous solutions with a sulfate concentration of 350, 750, and 3000 mg/l, corresponding to chemically aggressive exposures 5a, 5b, and 5c respectively, according to the European Norms (ENV 206). The deterioration of cement paste specimens was studied by X-ray diffraction analysis to detect ettringite and/or thaumasite formation in relationship with the visual observation of sulfate attack. The deterioration of mortar specimens was studied by measuring elastic modulus and compressive strength at different periods of aggressive exposure (from 1 month to 5 years). After 5 years of exposure to the sulfate attack, paste and mortar specimens with slag and pozzolan cements were undamaged independent of the sulfate concentration, sand type, and w/c. On the other hand, paste and mortar specimens with blended limestone-portland cements showed surface damage when exposed to the 3000 mg/l of sulfate aqueous solution. However, they did not show loss of either compressive strength or elastic modulus in the 5 years of sulfate exposure. The surface damage was mitigated when OPC was replaced by the C3A-free portland cement and completely eliminated when this cement was blended with a siliceous filler rather than with a limestone case. Thaumasite and ettringite are responsible for the surface attack. The amount of thaumasite was a little higher in the presence of blended limestone portland cement.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"159 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121018996","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effects of Cementitious Slag Content and Aggregate Type on Properties and Durability of Portland Blast-Furnace Slag Cement Concretes","authors":"G. Osborne, M. Connell","doi":"10.14359/5745","DOIUrl":"https://doi.org/10.14359/5745","url":null,"abstract":"A series of nine large concrete blocks (750 mm cube), stored outside on an industrial site at the Appleby Frodingham works at Scunthorpe in N.E. England were assessed at 7-8 months, 30 months and 7 1/2 and 10 1/2 years of age. The concrete contained a nominal total cementitious content of 390 kg/m3 and had different levels of ground granulated blast furnace slag in the range 0, 30, 50 and 70% by weight as replacement material for portland cement. Some of the concretes were prepared using gravel and others with crushed limestone as aggregate. The quality and performance of these concretes were determined at each age by testing drilled cores taken from the side face of the blocks, partly protected from driving rain. The assessment involved early heat release compressive strength. Comparisons were made between the different concretes on the basis of their cementitious slag content and aggregate types. The results showed that concretes containing 100% normal portland cement of 50% slag have hardly carbonated, although carbonation had progressed from 5 to 6 mm at 2 1/2 years where 70% slag was used, but there was little change thereafter. Gas permeability decreased slightly as the slag replacement levels were reduced from 70% to 50%, and the coefficient of oxygen permeability (ko) values for the inner concrete were in the range 0.5 to 9 x (10 to the minus 18 m square) by 2 1/2 years, which indicates that all concretes had low permeability. Impressive compressive strength gains were realized with time for the slag cement concretes which at 7 1/2 years were in the range 82.5 to 105 MPa compared with the plain portland cement concrete at 67.5 MPa, clearly demonstrating the beneficial long-term effect of slag on strength development. Benefits were also derived from the use of water reducing admixtures and from using crushed limestone as aggregate. These are discussed in relation to the longer-term performance of the concretes at 10 1/2 years.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128140525","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Durability of Concrete with Copper Slag Fine Aggregate","authors":"T. Ayano, K. Sakata","doi":"10.14359/5746","DOIUrl":"https://doi.org/10.14359/5746","url":null,"abstract":"The lack of natural fine aggregate in Japan is serious because the commitment to protect the natural environment is increasing. Many concrete engineers are eager to find fine aggregate sources other than the traditional river and sea sand. Copper slag fine aggregate is expected to be one of the alternatives although the location where the copper slag is available is limited. In this paper, some characteristics of concrete with copper slag will be clarified. The carbonated thickness, resistance to freezing and thawing, thermal resistance, shrinkage strain, creep and setting time have been examined. The strength, slump and durability of concrete with copper slag are not inferior to those of normal concrete. However, copper slag sometimes delays the setting time of concrete even if it is produced at the same refinery. The delay of setting time is more than one week in some cases, although the durability in concrete is not affected by it. The main reason will be determined and the solution will be given in this paper.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130061164","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Ordinary and Long-Term Durability of Reinforced Concrete Structures","authors":"M. Collepardi","doi":"10.14359/5738","DOIUrl":"https://doi.org/10.14359/5738","url":null,"abstract":"Durability of reinforced concrete structures (RCS) seems to be poor when compared with those of ancient un-reinforced structures. When ordinary durability (service life of 40-50 years) is needed, the poor behavior of RCS stems from human negligence in adopting the well-consolidated and available experiential knowledge. However, for long-term durability requirements (service life of 100 years and more) the inherent vulnerability of the steel-concrete system must be taken into account. The inherent vulnerability of RCS substantially depends on the following \"weak points\" of concrete: (i) Low tensile strength, (ii) High modulus of elasticity, and (iii) Microcracking caused by restrained thermal and drying shrinkage or service loading. This paper critically examines some possible future scenarios to achieve long-term durability in RCS, including: a) Improvement in the corrosion behavior of the metallic reinforcement through the use of corrosion inhibitors, protection of the reinforcement with a coating, change in the composition of reinforcing bars, or cathodic protection; b) Use of non metallic reinforcement; c) Increase in the tensile strength and/or ductility or concrete mixtures based on rubber-like polymer additions; and d) Surface coatings for concrete protection.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130832925","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of Metakaolin on External Sulfate Attack","authors":"T. Ramlochan, M. Thomas","doi":"10.14359/5752","DOIUrl":"https://doi.org/10.14359/5752","url":null,"abstract":"This paper reports a study on the effect of a high-reactivity metakaolin (HRM) on the sulfate resistance of mortars. Mortar bars containing 0-25% HRM were prepared in accordance with ASTM C 1012-89 with three cements of varying tricalcium aluminate content. After 6 months exposure to a 5% N2SO4 solution, mortar bars incorporating any level of HRM (5-25%) as a partial replacement for a high tricalcium aluminate cement may be considered \"moderate sulfate resistant\". Mortar bars made with HRM and a moderate or low tricalcium aluminate cement may be considered \"high-sulfate resistant\". Beyond 6 months, however, it was found that insufficient levels of HRM may, in fact, reduce the sulfate resistance of some cements, and that 15% HRM or more, may be required for long term sulfate resistance, depending on the tricalcium content of the cement.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"82 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128131340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Strength Development of Concrete Cured under High Temperature Conditions at Early Age","authors":"H. Sugiyama, Y. Masuda, M. Abe","doi":"10.14359/5796","DOIUrl":"https://doi.org/10.14359/5796","url":null,"abstract":"This paper describes a study on long-term strength development of concrete cured under high-temperature conditions at early age. The concrete specimens were made with normal portland cement, high-early-strength portland cement, and low-heat portland cement, and were cured under 26 different temperature conditions. It was clarified that a higher maximum temperature improved the strength of development of concrete at an early age, but inhibited the strength development of concrete at later ages. A shorter initial curing time inhibited the strength development of concrete at later ages. A time dependence of the effect of curing temperature on the strength development of concrete was observed.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132436243","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Grijalvo, M. Blanco-Varela, Francisca Puertas Maroto, A. Sánchez, T. V. Moreno
{"title":"Thaumasite Formation in Hydraulic Mortars and Concretes","authors":"J. Grijalvo, M. Blanco-Varela, Francisca Puertas Maroto, A. Sánchez, T. V. Moreno","doi":"10.14359/5808","DOIUrl":"https://doi.org/10.14359/5808","url":null,"abstract":"This paper details the state-of-the-art on thaumasite formation. Aspects of its formation in mortars and in portland-cement concretes are stressed, as is the effect its formation has on their durability. Methods for material synthesis, mentioned in the the bibliography including a detailed report of the characterization of thaumasite through XRD, IR, DTA/TG, NMR, electron microscopy, and microanalysis, are described.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130755058","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Modeling Chloride Penetration into Concrete with Lightweight Aggregates","authors":"M. Maage, S. Helland, J. Carlsen","doi":"10.14359/5765","DOIUrl":"https://doi.org/10.14359/5765","url":null,"abstract":"A model for predicting the initiation period of reinforcement corrosion for marine concrete structures was presented at the CANMET/ACI International Conference on Durability, Sydney, Australia, 1997. The theory has been refined to be valid also for short time curing and exposure. The objective of the program aimed at giving input data to the model for estimating the initiation period of reinforcement corrosion. Furthermore, the program should document the chloride ingress into various practical concretes made with lightweight aggregates, depending on a number of variables in curing and exposure conditions as well as concrete composition and materials. The most important variables were 1) curing time before exposure, 2) curing temperature, 3) exposure temperature, 4) exposure time, 5) type of exposure, 6) salt concentration in exposure medium and 7) type of binder. The most important conclusion was that the results fitted very well to the earlier presented hypothesis for the prediction of the initiation period independent of type of aggregate. Additionally the following main conclusions shall be mentioned: Surface chloride content is the environmental load, and it increases with the exposure time during the first years, and reduces with increased curing time and the introduction of slag, and is independent of curing and exposure temperature. The achieved diffusion coefficient is independent of curing and exposure temperature, and decreases with an increase of the exposure time and the introduction of slag. The parameter alpha expresses the time dependency of the achieved diffusion coefficient with exposure time. Alpha is independent of curing time, curing and exposure temperature, and it increases somewhat with increased salt concentration in the exposure water and introduction of slag.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125347271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Saricimen, M. Maslehuddin, M. Shameem, A. Al-Ghamdi, M. Barry
{"title":"Effect of Curing and Drying on Strength and Absorption of Concretes Containing Fly Ash and Silica Fume","authors":"H. Saricimen, M. Maslehuddin, M. Shameem, A. Al-Ghamdi, M. Barry","doi":"10.14359/5744","DOIUrl":"https://doi.org/10.14359/5744","url":null,"abstract":"In this study, the effect of curing and drying on the strength and absorption of plain and pozzolanic cement concretes were evaluated. The specimens were cured for 1, 3, 7, 14, 28 and 60 days. At each testing period, specimens were oven dried at 70 degrees Centigrade for 2, 8, 12 and 24 hours. The effect of curing and drying on the absorption capacity of concrete specimens was evaluated by measuring 48-hour absorption and volume of permeable voids. The specimens were also tested for compressive strength and moisture content. The results show an increase in the compressive strength in plain and pozzolanic cement concretes with increased curing and drying time. The absorption of these concretes decreased with time of curing and increased with drying period. The absorption of both fly-ash and silica-fume cement concrete specimens decreased significantly after three to seven days of curing. While the absorption of plain concrete specimens were effected significantly by drying period, no significant change in the absorption of pozzolanic cement concretes due to increasing drying period was observed, especially after seven days of curing. The volume of permeable voids also decreased with curing. The highest reduction in the absorption and volume of voids was observed in the fly-ash cement concrete specimens.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116975982","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Carbonation of Fly Ash Concrete","authors":"M. Thomas, J. D. Matthews","doi":"10.1680/MACR.1992.44.160.217","DOIUrl":"https://doi.org/10.1680/MACR.1992.44.160.217","url":null,"abstract":"The carbonation of fly ash concrete is reported, with particular emphasis on the role of curing. Concretes with nominal strength grades C25, C35 and C45 and a range of fly ash levels (0–50%) were e...","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1992-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116266124","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}