{"title":"Evaluation of Hexavalent Chromium-Free Passivation Treatment of Galvanized Bars for Reinforced Concrete","authors":"T. Bellezze, L. Coppola, R. Fratesi","doi":"10.14359/5772","DOIUrl":"https://doi.org/10.14359/5772","url":null,"abstract":"The zinc coating of galvanized rebars is often subjected to a passivation surface treatment by immersion in a hexavalent chromium aqueous solution in order to improve the corrosion resistance of the reinforcements when stored in air as well as when embedded in concrete. The chromate ion causes serious health problems to the operators working with the solution. Therefore, a hexavalent chromium-free passivation treatment of galvanized rebars is desirable. Two free-hexavalent chromium surface passivation treatments of galvanized rebars were obtained by immersion either in a trivalent chromium based solution or in a cobalt and titanium salts solution, both harmless to the workers. Conventional (hexavalent chromium based) passivated galvanized steel bars and galvanized rebars passivated with the two above alternative treatments were embedded in very porous concrete specimens manufactured with three different cements. These reinforced concrete specimens were exposed to wetting and drying cycles in a 3% sodium chloride aqueous solution. Free corrosion potential, corrosion rate, and visual observations of galvanized rebars indicated that the two hexavalent chromium free passivation treatments can give comparable or better protection than the conventional chromating treatment, independent of the type of cement used.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125209640","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
C. Famy, K. Scrivener, A. Brough, A. Atkinson, E. Lachowski
{"title":"Characterization of Calcium-Silicate-Hydrate Products in Expansive and Nonexpansive Heat-Cured Mortars-Electron Microscopy Study","authors":"C. Famy, K. Scrivener, A. Brough, A. Atkinson, E. Lachowski","doi":"10.14359/5761","DOIUrl":"https://doi.org/10.14359/5761","url":null,"abstract":"Mortars or concretes that have been cured at high temperature may suffer from expansion during subsequent moist storage at room temperature. This phenomenon is usually referred to as Delayed Ettringite Formation (DEF) because ettringite deposits have been observed in expansive structures. However no correlation has been established between the amount of ettringite detected in expansive heated mortars and the degree of expansion. Ettringite is prevalent in old structures regardless of the occurrence of deterioration. This study is aimed at investigating the expansion mechanism and in particular the role of ettringite relating to expansion. The results indicate that there is no direct cause between the ettringite detected by x-ray diffraction and expansion. Instead, evidence is presented for the possible implication of the calcium-silicate-hydrate (C-S-H) gel in the expansion mechanism. An important compositional difference was found between the outer C-S-H of expansive and non-expansive heated mortars that is the presence of ettringite formed in the outer C-S-H from calcium monosulfoaluminate, present within the outer C-S-H, and released sulfate from the C-S-H. Such ettringite can cause expansion because its formation takes place in situ in the outer C-S-H. The paste expands and detaches from the non-expansive components such as aggregates forming gaps at the paste/aggregate interfaces.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127998706","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of Fly Ash and Slag on Deicer Salt Scaling Resistance of Concrete","authors":"C. Talbot, M. Pigeon, J. Marchand","doi":"10.14359/5776","DOIUrl":"https://doi.org/10.14359/5776","url":null,"abstract":"In recent decades, many lab studies have clearly shown that the use of supplementary cementing materials, and particularly fly ash, can significantly reduce the scaling durability of properly air-entrained concrete. Despite the great deal of research done on the topic, the reasons behind the detrimental influence of fly ash remain unclear. In order to provide more information on the subject, this paper details an investigation conducted to determine the influence of fly ash on the deicer salt scaling resistance of concrete. All test results confirm that the use of fly ash and slag can reduce the salt scaling durability of concrete as determined in the lab. The influence of fly ash and slag does not appear to be linked to their effect on the material pore structure. An explanation linked to its influence on the characteristics of the air-void network is suggested.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125665683","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Freezing and Thawing Hysteresis Effects in Experimental Analysis of Frost Deicing Salt Resistance of Cementitious Materials","authors":"J. Kaufmann","doi":"10.14359/5778","DOIUrl":"https://doi.org/10.14359/5778","url":null,"abstract":"Hysteresis effects are very common in experimental studies of porous building materials. In the case of frost deicing salt resistance, hysteresis effects between freezing and thawing were reported in calorimetric and expansion experiments. They often were explained by a difference in the active pore diameter. However, the author's calorimetric and ultrasonic pulse velocity measurements show much smaller hysteresis effects, which supports another explanation: supercooling. A model based on non-connected pore water which may supercool was developed to explain the experimental differences. This model allows a reinterpretation of experimental expansion data. The moment of damage formation in frost deicing salt resistance tests can then be studied. Analysis of the causes of hysteresis effects therefore leads to improved models of frost deicing salt damage mechanisms.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114717917","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Factors Other Than Chloride Level Influencing Corrosion Rate of Reinforcement","authors":"A. Castel, R. François, G. Arliguie","doi":"10.14359/5775","DOIUrl":"https://doi.org/10.14359/5775","url":null,"abstract":"To evaluate the degree of corrosion, reinforcements of a fourteen-year-old concrete member were completely bared. The 3-meter long beams were stored in 3-point flexion in an aggressive environment made by sequences of drying and wetting by a salt fog (35 g/l). The total chloride content was also measured at the level of all reinforcements. Because of the small concrete cover (10 mm for the stirrups and 16 mm for the longitudinal reinforcement), the chloride content appears to be significantly greater than the threshold usually used to evaluate the initiation of corrosion. Carbonation front was also measured and was only about 4 mm. Nevertheless, the degree of corrosion (mass loss calculation) shows no correlation with chloride content, as some large parts of reinforcement are not affected by corrosion. As a result, corrosion damage seems to be linked to a degradation of the steel-concrete interface. For tensile reinforcement, it corresponds to a mechanical degradation whereas for compression reinforcement it corresponds to the bleeding. This observation leads us to question ourselves about the relevance of a single value for the corrosion threshold. The nature of the interface between the steel and the concrete must be considered.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123616418","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effects of Recycled Aggregate Characteristics on Performance Parameters of Recycled Aggregate Concrete","authors":"S. Nagataki, A. Gokce, T. Saeki","doi":"10.14359/5741","DOIUrl":"https://doi.org/10.14359/5741","url":null,"abstract":"This study points out the close relationship between several quality indicators of recycled aggregate and the performance of recycled aggregate concrete. Regarding the diversity in quality and composition of the recycled concrete products, three laboratory produced air-entrained-concretes with low, medium and high water-cement ratios and a non-air-entrained concrete with medium water/cement were processed for recycling. Recycled aggregate concretes were produced with a water/cement of 0.55, and tested after 28 days of moist curing. Results of the capillary water immersion and permeable porosity tests indicate that structure and amount of adhered mortar as well as the recovery percent of original coarser aggregate, especially the inclusion of recycled fine aggregate into the system, are the main reasons creating important differences in the permeable pore system and absorptivity of recycled aggregate concretes. Relatively low pore content of the non-air-entrained type adhered mortar compared with the air-entrained ones influences the concrete porosity in the same way. The volume of permeable pores in concrete produced with non-air entrained type of recycled aggregate seems to be reduced. Although entrained air pores of the adhered mortar increase the total volume of the permeable voids, they play a role of interrupting the capillaries. The findings of this research indicate that all possible variations in recycled aggregate properties must be taken into account to be able to design durable recycles aggregate concretes.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128347565","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of Sulfate Concentration and Associated Cation Type on Chloride-Induced Reinforcement Corrosion","authors":"H. Dehwah, M. Maslehuddin, S. Austin","doi":"10.14359/5760","DOIUrl":"https://doi.org/10.14359/5760","url":null,"abstract":"This investigation was conducted to evaluate the effect of sulfate concentration and associated cation type on chloride-induced reinforcement corrosion. Reinforced concrete specimens were exposed to chloride-sulfate environments for a period of 600 days and reinforcement corrosion was evaluated by measuring corrosion potentials and corrosion current density. The corrosion current density increased with increasing sulfate concentration and the cation type associated with the sulfate ions significantly influenced chloride-induced reinforcement corrosion. Reinforcement corrosion in the concrete specimens exposed to sodium chloride plus magnesium sulfate solution was more than that in the concrete specimens exposed to sodium chloride plus sodium sulfate solution.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"108 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127055085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Carbonation Degree as Durability Criteria for Autoclaved Aerated Concrete","authors":"F. Matsushita, S. Shibata","doi":"10.14359/5805","DOIUrl":"https://doi.org/10.14359/5805","url":null,"abstract":"This paper deals with the durability and its criteria for Autoclaved Aerated Concrete (AAC) panels. Cracking, panel bending properties, compressive strength, drying shrinkage, and carbonation degree were investigated for field AAC panels aged 4-33 years. When the carbonation degree was >50%, the AAC panels showed cracking and degradation in span-deflection ratio, compressive strength, and drying shrinkage. Therefore, in this paper, the authors propose the durability criteria for AAC as: when the degree of carbonation of an AAC panel exceeds 50% as defined in this work, it may be considered as deteriorated. With this criteria, acrylic-resin-finished AAC panels were 1.5 times more durable than non-finished ones. Also, water-repellent AAC panels had twice the durability as normal ones.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130632690","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Marine Durability of 23-Year-Old Reinforced Concrete Beams","authors":"T. Mohammed, N. Otsuki, M. Hisada, H. Hamada","doi":"10.14359/5802","DOIUrl":"https://doi.org/10.14359/5802","url":null,"abstract":"This paper gives findings of marine durability tests of 23-yr-old reinforced concrete beams exposed to marine tidal and atmospheric environments. The study mainly focused on corrosion of steel bars with respect to orientation in concrete, carbonation and chloride-ion induced corrosion of steel bars, quantitative evaluation of corrosion based on the electrochemical data, and the influence of stirrups on macrocell formation. Experimental work covered electrochemical investigations, chloride ion profile and carbonation depth measurements, microscopic steel concrete interfaces, and visual observation of steel bar corrosion. The study found that chloride-ion induced corrosion is significantly influenced by the orientation of steel bars in concrete. Cracks and interfacial gaps between steel and concrete must be accounted for in order to predict corrosion of steel bars in concrete.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125410825","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effects of Mixture Proportions on Permeability and Pore Structure of High-Fluidity Concretes","authors":"M. Kakizaki, H. Edahiro, K. Fujii, H. Nakase","doi":"10.14359/5783","DOIUrl":"https://doi.org/10.14359/5783","url":null,"abstract":"This paper discusses the influences of water-binder (W/B) ratio, type of admixture, and amount of fly ash on the permeability and pore structure of high-fluidity concretes (HFC). Permeability of HFC decreased with a decrease in W/B ratio regardless of the type of chemical admixture and addition of fly ash used. It also decreased with additions of fly ash and this tendency was noticeable at lower W/B ratio and was affected by factors such as applied pressure, type of concrete, and W/B ratio. Air permeability of all types of concrete decreased with an increase in applied pressure. Total pore volume of HFC decreased with a decrease in W/B ratio and the number of fine pores increased. This tendency was noticeable when fly ash was added to mixtures.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125672014","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}