{"title":"Accelerated Corrosion Testing Results for Specimens Containing Uncoated Reinforcing Steel and Corrosion Inhibitors","authors":"I. Kondratova, P. Montes, T. Bremner","doi":"10.14359/5785","DOIUrl":"https://doi.org/10.14359/5785","url":null,"abstract":"Concrete slabs containing uncoated reinforcing bars were cast with a concrete cover of 20 mm. The w/c was either 0.25, 0.40, or 0.60. A simulated crack 0.4-mm wide was formed transverse to the axis of the reinforcing bar. Three types of commercial corrosion inhibitors were added to concrete mixtures for corrosion protection. Slabs were placed in an accelerated exposure cabinet with 4 cycles of wetting/drying per day in simulated seawater. Corrosion rates were measured using the linear polarization technique. Some of the concrete slabs were broken open at the end of the exposure period and corrosion damage was evaluated. Water soluble chloride content analysis in the rebar trace was performed at the end of the exposure period for all the examined specimens. The various types of corrosion inhibitors showed a wide variation in performance and their effectiveness was also found to be particularly sensitive to addition rate. In general, all had a greater effectiveness in reducing corrosion rate in a higher w/c ratio concrete than in a lower w/c ratio concrete.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124631365","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Utilization of Natural Zeolite in Portland Pozzolan Cement of Increased Sulfate Resistance","authors":"I. Janotka, L. Krajči","doi":"10.14359/5751","DOIUrl":"https://doi.org/10.14359/5751","url":null,"abstract":"The objective of this paper is to characterize sulfate resistance of the mortars (cement to sand = 1:3 by weight, W/C = 0.6) made from blended portland pozzolan cement with 15 wt.% of zeolite, and to compare it to that of mortars made from normal portland cement and sulfate resistance portland cement. The improved sulfate resistance of mortars with portland pozzolan cement is caused by: 1. decreased tricalcium aluminate in the blended cement in comparison with that in normal portland cement; 2. decreased content of calcium hydroxide capable of reacting with a sulfate solution due to pozzolanic reaction of zeolite with the cement relative to that in normal portland cement; 3. ion-exchange capacity of zeolite to Ca 2+ ions; 4. negligible change in pore structure of portland pozzolan cement mortars compared to portland cement mortar which is characterized by significant conversion of capillary pores to gel pores, as a result of formation of voluminous reaction products of the sulfate attack. The results show that sulfate resistance of portland pozzolan cement was similar to that of the sulfate resistant portland cement.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114261708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Coppola, S. Monosi, C. Pistolesi, R. Troli, P. Zaffaroni
{"title":"Four-Year Behavior of Polymer-Cement Coatings for Concrete Protection","authors":"L. Coppola, S. Monosi, C. Pistolesi, R. Troli, P. Zaffaroni","doi":"10.14359/5810","DOIUrl":"https://doi.org/10.14359/5810","url":null,"abstract":"An aqueous emulsion of an acrylic polymer was mixed with cement and fine aggregate and was studied as a rubber-like coating to protect reinforced concrete (RC) beam specimens. Three acrylic polymer-cement coatings were produced by changing the type of the cementitious component. The coatings were applied to a porous concrete substrate with a water-cement ratio of 0.80. Coated beam specimens were kept for 4 years in 3 different environments to examine the influence of aging on the bond strength as well as the flexibility and therefore the ability of the acrylic coatings to bridge the crack of the concrete substrate. The latter was determined by measuring the crack width of the concrete substrate beam when the coating started to break under flexural stress. Bond strength of the coatings was substantially unchanged up to 4 yrs in lab conditions, whereas there was a small flexibility loss of the coating in humid environments, especially in permanent underwater exposure. However, even when in these less than favorable conditions, the crack-bridging ability of the 3 coatings was still satisfactory after 4 yrs.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114497947","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Efficiency Factors (k-Values) for Supplementary Cementing Materials Regarding Carbonation and Chloride Penetration","authors":"V. Papadakis","doi":"10.14359/5748","DOIUrl":"https://doi.org/10.14359/5748","url":null,"abstract":"For comparing the relative performance of supplementary cementing materials (SCM) with regard to concrete durability, the concept of efficiency factor may be used. The efficiency factor (k-value) is defined as the part of the SCM in an SCM-concrete which can be considered as equivalent to portland cement. In this work, three typical SCM were studied: a silica fume, a low-calcium fly ash and a high-calcium fly ash. Accelerated carbonation and chloride penetration tests were performed. With regard to 28 day compressive strengths, k-values of 3, 0.5 and 1 for silica fume, low-calcium fly ash, and high-calcium fly ash, respectively, were estimated. Mathematical models describing the carbonation propagation and chloride intrusion were applied to estimate the durability k-values. Higher k-values with respect to chloride penetration were found, indicating that SCM reduce the chloride permeability more effectively than they improve the compressive strength. On the contrary, with respect to carbonation depth, k-values of 0.3, 0.5 and 0.7 for silica fume, low-calcium fly ash and high-calcium fly ash, respectively, were estimated. A theoretical explanation of these results is also given.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114601685","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Beeldens, D. Gemert, C. Caestecker, M. V. Messem, E. D. Winne
{"title":"Influence of Polymer Modification on Durability of Porous Concrete","authors":"A. Beeldens, D. Gemert, C. Caestecker, M. V. Messem, E. D. Winne","doi":"10.14359/5784","DOIUrl":"https://doi.org/10.14359/5784","url":null,"abstract":"Porous concrete is used as a top layer on highways and is characterized by a very open structure due to use of gap-graded aggregates, providing good drainage capabilities and noise reducing properties. A preliminary program tested the durability of porous concrete. To improve concrete strength and durability, a polymer emulsion was added to the concrete mixture; 3 different types were used. The resistance against freeze-thaw cycles, deicing salts, temperature variation, and wetting/drying cycles were studied on samples with a polymer-cement ratio of 0.10. Minimum film forming temperature, strength, and elasticity of the polymer emulsion, and of the hardened polymer film, were also determined. This paper examines results of the durability tests and examines the relation between the properties of the polymer emulsion and behavior of the polymer modified porous concrete. The role of the polymer film concerning structure formation and durability behavior in the hardened concrete are discussed.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"35 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121823855","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. A. Al-Juraifani, Saleh H. Al-Idi, M. Maslehuddin, M. Al-Zahrani, S. Al-Dulaijan
{"title":"Performance Evaluation of Repair Materials under Hot and Arid Conditions","authors":"E. A. Al-Juraifani, Saleh H. Al-Idi, M. Maslehuddin, M. Al-Zahrani, S. Al-Dulaijan","doi":"10.14359/5795","DOIUrl":"https://doi.org/10.14359/5795","url":null,"abstract":"This study evaluates the performance of cement- and polymer-based repair materials under hot weather conditions. Strength and durability characteristics of these repair materials were tested under elevated temperature and low humidity. It was noted that the combined effect of high temperature and low humidity conditions, though not harmful to strength characteristics of the repair materials, severely accelerates their shrinkage. Based on the data developed herein, performance criteria for evaluation of repair materials for hot and arid conditions are suggested.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123220573","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Concrete Cover Cracking with Localized Corrosion of Reinforcing Steel","authors":"A. Torres‐Acosta, A. Sagüés","doi":"10.14359/5773","DOIUrl":"https://doi.org/10.14359/5773","url":null,"abstract":"The work estimated experimentally the critical amount of steel corrosion needed for concrete cover cracking of a reinforced concrete element where only a fraction of the steel bar length is corroding. The amount of corrosion needed to crack the concrete cover was ~ 49 micrometers to ~ 137 micrometers in specimens with localized corrosion, in comparison to ~ 15 micrometers to 75 micrometers for uniform corrosion reported for the other investigations in comparable systems. An empirical equation is proposed for the critical amount of steel corrosion as a function of specimen dimensions (concrete clear cover, C; rebar diameter, theta; and anodic length, L). In this equation the critical amount of steel corrosion is proportional to the first power of C/theta and to a higher power of [C/L+1]. Quantitative determinations of the development and magnitude of stresses produced by corroding steel in concrete have been obtained. Estimated pressures at the steel/concrete interface for C/theta >= 3 reached values comparable to the concrete compressive strength. The potential use of a fracture-energy-based model to predict the critical amount of steel corrosion needed for concrete cover cracking of a reinforced concrete element was supported by indications of approximate agreement between estimates of the work of corrosion expansion and the energy required to crack the concrete.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123279713","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Mechanism of Deterioration of Cement Composites Due to Leaching of Calcium","authors":"Kenzo Watanabe, K. Yokozeki, N. Otsuki, M. Daimon","doi":"10.14359/5807","DOIUrl":"https://doi.org/10.14359/5807","url":null,"abstract":"This paper describes the degradation mechanism of cement composites derived from accelerated testing. Investigations were conducted using 3 different accelerated test methods (immersion, dissolution, and permeation cell test methods). Main findings of the study include: 1) 30-50% of calcium in cement composites was leached out in several months in the accelerated tests; 2) in all tests, calcium leaching from Ca(OH)2 and C-S-H was observed, and the change in porosity and physical properties corresponding to the leaching degree was found; and 3) a possibility to predict the long-term degradation behavior of structures by using numerical analysis was demonstrated.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122498632","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Corrosion Measurements in Three Types of Reinforced Concrete Slabs Exposed to Chloride Solution","authors":"O. Kayali, B. Zhu","doi":"10.14359/5768","DOIUrl":"https://doi.org/10.14359/5768","url":null,"abstract":"Reinforced-concrete slabs were cast and tested for durability for a period of fifteen months. The slabs were partially immersed in a 2.0% chloride ion solution. Three types of concrete were tested. These were normal-weight medium strength (NWMS), lightweight high-strength (LWHS), and normal-weight high strength (NWHS) concrete. The main tests consisted of measurement of corrosion potential, corrosion current and chloride ion penetration. It has been found that the values of corrosion potential and current were substantially different in the three different types tested. Extremely low values of corrosion current were detected in high strength concrete slabs whether made of lightweight or normal-weight concrete. Large amount of cementitious materials and very low ratio of water to cementitious materials are believed to strongly contribute to produce very low corrosion current. However, LWHS slabs exhibited very high values of corrosion potential while corrosion current values for these slabs were extremely low. The paper presents the results and discusses likely explanation of these observations.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116551788","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Study on Construction Method and Durability of Carbon Fiber-Reinforced Plastic Sheet for Retrofitting Reinforced Concrete Structures","authors":"Y. Masuda, K. Motohashi, T. Kage, T. Ina","doi":"10.14359/5792","DOIUrl":"https://doi.org/10.14359/5792","url":null,"abstract":"This paper describes experimental work and analysis conducted to study the influences of lap length on carbon fiber reinforced plastic (CFRP) sheet layer to tensile stress, the influences of time interval on lapping to lap-joint tensile strength, and strengthening method of CFRP sheet having an opening. The effects of finishing materials on durability using this method and durability of finish itself were tested. Results indicate that the tensile strength of the lap joint using epoxy resin and the influences of time interval when lapping is performed are clarified. The effect of strengthening method of CFRP sheet on an opening part is stated. Adhesive strength between the concrete surface and CFRP sheet did not change during the period of this experiment. The mortar finish bonded on the surface of the CFRP sheet with adhesive and sand has a risk to peel off.","PeriodicalId":137341,"journal":{"name":"SP-192: 2000 Canmet/ACI Conference on Durability of Concrete","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125814929","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}